← All vessels
VENTURER
Freight Ship · Bulk Carrier class · Built 1980s · USCG East District (CGD-E) · Other hulls named VENTURER
VENTURER is a 1980 freight ship. The Coast Guard has recorded 20 inspections since 1986, most recently in December 2008, along with 14 deficiencies and 5 operational controls.
Records from 1986 to 2008. Most recent: inspection, 6 December 2008.
- Built
- 1980
- Last inspected
- 6 December 2008
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 14 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7917850 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ICJT
227982
Flag
ITALY
—
Maury page id
psix-227982
Inspections, by type
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it68619 - Regulatory (Subpart C or D), Gross Ton
42948 - Regulatory (Subpart C or D), Net Ton
127907 - Dead Weight, Ton
127907 - Displacement, Ton
42948 - Regulatory (Subpart C or D), Net Ton
127907 - Dead Weight, Ton
127907 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 20
6 December 2008
PI Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3374745
3 December 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3373702
16 September 2008
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3325855
7 August 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3291933
24 May 2008
ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3215085
19 February 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3150037
19 February 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3150271
17 February 2008
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3148838
23 October 2004
Deficiency Check · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2226653
17 October 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2222841
26 January 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 273739
5 April 1998
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 414654
1 November 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 396758
7 September 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 54405
8 August 1994
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 369191
4 June 1992
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 351105
30 August 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 339025
6 November 1987
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 319471
27 January 1987
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 470023
3 April 1986
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 307854
Deficiency record · 14
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 September 2008
Resolved
OWS not functioning properly. PSC Team witnessed two unsuccessful attempts to operate the Oily Water Separator. Each time unit showed inconsistent readings on oil content meter, would not open three way valve and discharged water from the top of the coalescer filter housing.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 16 September 2008
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 February 2008
Resolved
Oily Water Separator (OWS) not operational. Vessel is currently retaining all product on board and discharging ashore. Condition of Class (COC) received from RINA giving the vessel approval to sail to next port (France). Vessel is capable of retaining all oily mixtures on board. OWS will be replaced in France. Documentation of OWS replacement is onboard the vessel and copies were obtained.
Engineering
Issued 26 January 2000
Resolved
PERMANENT REAPIR NEEDED TO L/O RISER LINE AT FLANGE FOR MAIN ENGINE TURBO.
Unknown
Issued 26 January 2000
Resolved
REMOVE FUEL FROM BILGE UNDER GENERATORS, CLEAN AREA UNDER F/O PURIFIERS ANDREMOVE F/O AT AND AROUND F/O HEATERS.
Engineering
Issued 26 January 2000
Resolved
FUEL LEAKING ON NUMBER 1, 3, AND 6 CYLINDER PUMPS ON STARBOARD GENERATOR.
Construction/Loadline
Issued 5 April 1998
Resolved
MAKE PERMANENT REPAIRS TO FRACTURE IN WAY OF #6 CARGO HOLD, FORWARD STARBOARD SUPPORT GUSSET. ICLL 66 ANNEX I R 14.
Construction/Loadline
Issued 5 April 1998
Resolved
PERFORM PREVENTATIVE MAINTENANCE ON MAIN WEATHER DECK WATERTIGHT DOORS. ICLL 66 R.12
Fire Fighting
Issued 5 April 1998
Resolved
FIRE CONTROL PLANS NEED TO BE UPDATED TO ENSURE POSTED PLAN AND EXTERIOR PLANS ARE BOTH ACCURATE. SOLAS 74 REG 11-2/20.1
Deck/Cargo
Issued 5 April 1998
Resolved
MAKE PERMANENT REPAIRS TO HYDRALIC LEAKS IN WAY OF #5 CARGO HOLD AFT JACK AND PORT ISDE CRANE CONTROLS ON LIFE BOAT DECK.
Engineering
Issued 5 April 1998
Resolved
RENEW FRAYED ARMORED OIL LINE HOSE ON STARBOARD SIDE MAIN ENGINE. SOLAS 74UNAMENDED CHAPII-2/33
Engineering
Issued 5 April 1998
Resolved
RENEW FRACTURED FUEL OIL RETURN LINE IN WAY OF #2 CYLINDER GALLERY ON #1 SHIP SERVICE GENERATOR.
Engineering
Issued 5 April 1998
Resolved
CLEAN AND REPAIR ALL FUEL OIL VENT FLAME SCREENS.
Engineering
Issued 5 April 1998
Resolved
REMOVE FIBERGLASS SOFT PATCH ON FUEL OIL VENT AND MAKE PERMANENT REPAIRS INWAY OF STARBOARD #5 UWT VENT.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.