MAURY USCG vessel records Sign in
← All vessels

AGIOS DIMITRIOS

AGIOS DIMITRIOS is a 1980 freight ship. The Coast Guard has recorded 14 inspections since 1985, most recently in January 2002, along with 57 deficiencies and 3 operational controls.

Records from 1985 to 2002. Most recent: inspection, 23 January 2002.

Built
1980
Last inspected
23 January 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7919822 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227991
Flag
VANUATU
—
Maury page id
psix-227991

Inspections, by type

…with no type recorded13
Years with a record 9 calendar years (1985–2002)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it23566 - Regulatory (Subpart C or D), Gross Ton
38101 - Dead Weight, Ton
13884 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 14

23 January 2002 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1480879
27 September 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 765946
26 September 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 189373
26 September 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 282454
24 September 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 159317
8 June 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 278543
6 March 1998 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 413298
10 April 1997 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 402417
23 August 1996 Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 537306
8 March 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 388074
13 August 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 648015
19 September 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 332679
9 September 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 311299
8 March 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 300819

Deficiency record · 57

Accommodation/Occupational Safety
Issued 26 September 2000 Resolved
Make the lights in the engine room escape trunk operable. SOLAS 60 I/II._x001C_ _x001C_ _x001C_ Correct item to the satisfaction of class prior to departure.
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Accommodation/Occupational Safety
Issued 26 September 2000 Resolved
Investigate source of water flooding deck in stbd pipe tunnel. SOLAS 60 I/II. _x001C_ _x001C_ Correct item to the satisfaction of classs prior to departure.
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Documentation
Issued 26 September 2000 Resolved
Update oil transfer procedures prior to any petroleum transfer both internal and external. _x001C_ _x001C_ Item corrected 28 Sep 00._x001C_
Condition: Unknown
Due 28 September 2000
Resolved 2 October 2000
Engineering
Issued 26 September 2000 Resolved
Install mechanical plugs in containment drains. 33 CFR 156.120._x001C_ _x001C_ _x001C_ Correct prior to next U.S. port after sailing foreign.
Condition: Unknown
Due 27 September 2000
Resolved 23 January 2002
Resolution: MECHANICAL PLUGS INSTALLED.
Engineering
Issued 26 September 2000 Resolved
Prove proper operation of aux. boiler. SOLAS 60 I/II._x001C_ _x001C_ _x001C_ Correct item to the satisfaction fo class prior to departure.
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Fire Fighting
Issued 26 September 2000 Resolved
Provide instructions for fixed foam fire extinguishers stbd side above aux boiler, and provide date of last service. SOLAS 60 II/57._x001C_ _x001C_ Correct item to the satisfaction of class prior to departure.
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Electrical
Issued 26 September 2000 Resolved
Make emergency air compressor operable. SOLAS 60 I/II. _x001C_ _x001C_ _x001C_ Correct item to the satisfaction of class prior to departure.
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Fire Fighting
Issued 26 September 2000 Resolved
Re-install key box at emergency box to pump controlers stbd main deck near engine room entrance. SOLAS 74amd II-2/21._x001C_ _x001C_ Correct item to the satisfaction of class prior to departure.
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Navigation
Issued 26 September 2000 Resolved
Install split key or double nut on linkage arms at steering gear. SOLAS 60 I/II._x001C_ _x001C_ Correct item to the satisfaction of class prior to departure.
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Accommodation/Occupational Safety
Issued 26 September 2000 Resolved
Prove proper operation of fresh water generator and repair as original where patched. SOLAS 60 I/II._x001C_ _x001C_ Correct item to the satisfaction of class prior to departure.
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Construction/Loadline
Issued 26 September 2000 Resolved
Repack #2 ballast pump. SOLAS 60 I/II._x001C_ _x001C_ _x001C_ Correct item to the satisfaction of class prior to departure.
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Engineering
Issued 26 September 2000 Resolved
Renew switch at controller to #1 s/w cooling pump at lower engine room, stbd near aft of main engine. SOLAS 60 II/26._x001C_ _x001C_ Correct item to the satisfaction of class prior to departure.
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Engineering
Issued 26 September 2000 Resolved
Remove or blank off all unused pipes in engine room. (Inboard of fresh water generator and aft of fresh water generator). SOLAS 60 I/II._x001C_ _x001C_ Correct item to the satisfaction of class prior to departure.
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Engineering
Issued 26 September 2000 Resolved
Renew valve handle to m/e l/o cooler. SOLAS 60 I/II._x001C_ _x001C_ _x001C_ Correct item to the satisfaction of class prior to departure.
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Electrical
Issued 26 September 2000 Resolved
Repack #2 generator cooling pump. SOLAS 60 I/II._x001C_ _x001C_ _x001C_ Correct item to the satisfaction of class prior to departure.
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Electrical
Issued 26 September 2000 Resolved
Repair fuel return tube where fractured on #1 generator. SOLAS 60 I/II._x001C_ _x001C_ _x001C_ Complete item to the satisfaction of class prior to departure.
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Fire Fighting
Issued 26 September 2000 Resolved
Renew pipe where soft patched at stbd side of engine room, generator level,aft of main engine. SOLAS 60 I/II._x001C_ _x001C_ Correct item to the satisfaction of class prior to departure.
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Lifesaving
Issued 26 September 2000 Resolved
Renew all life jacket light batteries where expired. SOLAS 74and III/27.2._x001C__x001C_ _x001C_ Correct item to the satisfaction of class prior to departure.
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Lifesaving
Issued 26 September 2000 Resolved
Place life jackets in engine room for watchstanders. SOLAS 74amd III/7._x001C_ _x001C_ _x001C_ Correct item to the satisfaction of class prior to departure.
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Engineering
Issued 26 September 2000 Resolved
Repair ram at main engine fuel control system where leaking oil. SOLAS 60 I/II._x001C_ _x001C_ Correct item to the satisfaction of class prior to departure.
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Engineering
Issued 26 September 2000 Resolved
Install split keys as original at all linkage points on main engine fuel control arms. SOLAS 60 I/II._x001C_ _x001C_ Correct item to the satisfaction of class prior to departure.
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Accommodation/Occupational Safety
Issued 8 June 2000 Resolved
Repair/ Renew as original leaking sanitary pump. SOLAS 74 I/11
Condition: Unknown
Due 26 September 2000
Resolved 2 October 2000
Engineering
Issued 8 June 2000 Resolved
Repair/ Renew as original cutoff valve from fresh water feed pump to boiler. SOLAS 74 I/11
Condition: Unknown
Due 26 September 2000
Resolved 2 October 2000
Lifesaving
Issued 8 June 2000 Resolved
Provide operational plugs for port lifeboat. SOLAS (Amended) CH. III.26
Condition: Unknown
Due 26 September 2000
Resolved 2 October 2000
Accommodation/Occupational Safety
Issued 8 June 2000 Resolved
Ensure toilet located on bridge is operational. ILO 147
Condition: Unknown
Due 26 September 2000
Resolved 2 October 2000
Electrical
Issued 8 June 2000 Resolved
Repair/ Renew as original leak which is causing water to drip on to light fixture in bread making area. SOLAS 74 II-1/27
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Fire Fighting
Issued 8 June 2000 Resolved
Repair/ Renew as original overboard valve for #2 fire pump outlet. SOLAS 74(Amended) II-2/21
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Navigation
Issued 8 June 2000 Resolved
Calibrate Gyro-Compass in steering gear room to match Gyro-Compass on bridge. SOLAS 74 (Amended) V
Condition: Unknown
Due 26 September 2000
Resolved 2 October 2000
Construction/Loadline
Issued 8 June 2000 Resolved
Repair/ Renew as original overboard valve for ballast pipe located in engine room, lower level, starboard side, forward. SOLAS 74 I/11
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Accommodation/Occupational Safety
Issued 8 June 2000 Resolved
Repair/ Renew as original overboard valve from fresh water generator. SOLAS74 I/11
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Engineering
Issued 8 June 2000 Resolved
Repair/ Renew as original boiler blowdown drain pipe overboard valve SOLAS 74 I/11
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Electrical
Issued 8 June 2000 Resolved
Repair/ Renew as original seal in #1 generator salt water pump. SOLAS 74 I/11
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Engineering
Issued 8 June 2000 Resolved
Repair/ Renew as original #1 generator cooling pipe between lube oil coolerand fresh water cooler. SOLAS 74 I/11
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Engineering
Issued 8 June 2000 Resolved
Repair/ Renew as original #3 generator fresh water cooling cylinder. SOLAS 74 I/11
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Construction/Loadline
Issued 8 March 1996 Resolved
Provide necessary maintenance to the watertight door from weatherdeck to accomodation spaces, port side to achieve complete closure._x001C_ _x001C_ ILLC Ch II, Reg 12
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Navigation
Issued 8 March 1996 Resolved
Correct the hydraulic leaks at various pipe connections on the steering system; also remove the excessive oil in the containment._x001C_ _x001C_ Solas Ch II-1, Reg 26
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Lifesaving
Issued 8 March 1996 Resolved
Remove the rubber hose from the M/E lube oil "scavenge box" to the sump pump. _x001C_ _x001C_ Solas Ch II-2, Reg 23
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Fire Fighting
Issued 8 March 1996 Resolved
Remove the hose in the steering gear compartment connected to the deep wellpump for the F/W tank. It runs throught the fire doorway and prevents closure of the fire door._x001C_ Solas Ch II-2, Reg 23
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Electrical
Issued 8 March 1996 Resolved
Provide proper wiring to replace the spliced cable connecting the deep wellpump in the steering gear space to the junction box in the cable room. Thewiring runs through the fire doorway and prevents closure of the door._x001C_ Solas Ch II-2, Reg 27
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Lifesaving
Issued 8 March 1996 Resolved
Repair and prove proper operation of the port and starboard lifeboat limit switches._x001C_ _x001C_ Solas Ch III, Reg 36
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Electrical
Issued 8 March 1996 Resolved
Remove the heat lamps for the windlass motor in the forecastle or provide permanent installation to replace the improper uninsulated wires currently in use._x001C_ Solas Ch III, Reg 27
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Electrical
Issued 8 March 1996 Resolved
Properly wire the shaft RPM meter which is currently wired from the bulkeadto the meter across the walkway next to the shaft (it also creates a tripping hazard as it hangs several inches above the deck), prior to the next U.S. port call. Solas Ch II-1, Reg 27
Condition: Unknown
Due 26 August 1996
Resolved 26 August 1996
Electrical
Issued 8 March 1996 Resolved
Provide a battery for the the daylight signalling lamp currently connected to wire running from the battery room through the engine room to the bridge, prior to the next U.S. port call._x001C_ Solas Ch V, Reg 11
Condition: Unknown
Due 26 August 1996
Resolved 26 August 1996
Lifesaving
Issued 8 March 1996 Resolved
Make permanent repairs to the missing and rotten floorboards in the port lifeboat, prior to the next U.S. port call._x001C_ _x001C_ Solas Ch III, Reg 5
Condition: Unknown
Due 26 August 1996
Resolved 26 August 1996
Deck/Cargo
Issued 8 March 1996 Resolved
Correct the leaking cargo hatch rams/connections located at cargo hatch #7 aft, #6 aft, #6 fwd, #3 aft, #3 fwd, #2 fwd, #1 aft and #1 fwd._x001C_ _x001C_ 33 CFR 151.10
Condition: Unknown
Due 26 August 1996
Resolved 26 August 1996
Deck/Cargo
Issued 8 March 1996 Resolved
Correct the hydraulic leaks in the hatch cover controls located at the #2 cargo hold, port side, #3 port side, and #7 port side._x001C_ _x001C_ 33 CFR 151.10
Condition: Unknown
Due 26 August 1996
Resolved 26 August 1996
Accommodation/Occupational Safety
Issued 8 March 1996 Resolved
Make permanent repairs to the soft patched S/W outlet line from the sewage tank at the T-connection to the discharge line outboard of the isolation valve from the tank prior to the next U.S. port call. _x001C_ Solas Ch II-2, Reg 26
Condition: Unknown
Due 26 August 1996
Resolved 26 August 1996
Electrical
Issued 8 March 1996 Resolved
Remove or secure the light fixture with the exposed wires in the second (stbd) paint locker._x001C_ _x001C_ Solas Ch II-1, Reg 27
Condition: Unknown
Due 26 August 1996
Resolved 26 August 1996
Documentation
Issued 9 September 1986 Resolved
VESSEL OIL RECORD BOOK DID NOT HAVE THE POSITION OF START AND FINISH OF DISCHARGE.
Condition: Unknown
Due 19 September 1989
Resolved 9 September 1986
Navigation
Issued 9 September 1986 Resolved
VESSEL HAD A LIGHT LIST VOL.III (1984 ED) WITH NO CORRECTIONS.
Condition: Unknown
Due 9 September 1986
Resolved 9 September 1986
Navigation
Issued 9 September 1986 Resolved
VESSEL'S MANEUVERING INFORMATION HAD ONLY INFORMATION FOR FULL SPEED.
Condition: Unknown
Due 19 September 1989
Resolved 9 September 1986
Navigation
Issued 9 September 1986 Resolved
VESSEL DID NOT HAVE SIMPLE OPERATING INSTRUCTIONS & BLOCK DIAGRAM SHOWING CHANGE OVER PROCEDURES.
Condition: Unknown
Due 19 September 1989
Resolved 9 September 1986
Navigation
Issued 9 September 1986 Resolved
VESSEL DID NOT HAVE A COPY OF THE INLAND NAVIGATION RULES.
Condition: Unknown
Due 9 September 1986
Resolved 9 September 1986
Documentation
Issued 9 September 1986 Resolved
VESSEL OIL TRANSFER PROCEDURES HAD ONLY A LINE DIGRAM & DUTIES BY TITLE.
Condition: Unknown
Due 19 September 1989
Resolved 9 September 1986
Documentation
Issued 9 September 1986 Resolved
VESSEL DID NOT HAVE OIL DISCHARGE PROHIBITED PLACARD.
Condition: Unknown
Due 9 September 1986
Resolved 9 September 1986
Navigation
Issued 9 September 1986 Resolved
VESSEL CHARTS OF THE AREA WERE CURRENT EDITIONS WITH NO CORRECTIONS. ALL CHARTS WERE 1985 EDITION.
Condition: Unknown
Due 9 September 1986
Resolved 9 September 1986
Navigation
Issued 9 September 1986 Resolved
VESSEL COAST PILOT VOL.7 (1984 ED) HAD NO CORRECTIONS.
Condition: Unknown
Due 9 September 1986
Resolved 9 September 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.