MAURY USCG vessel records Sign in
← All vessels

CHAMPION VENTURA

CHAMPION VENTURA is a 1981 tank ship. The Coast Guard has recorded 38 inspections since 1985, most recently in April 2006, along with 48 deficiencies — 3 with no resolution recorded —.

Records from 1985 to 2006. Most recent: inspection, 28 April 2006.

Built
1981
Last inspected
28 April 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7920493 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227999
Flag
NORWAY
—
Maury page id
psix-227999

Inspections, by type

…with no type recorded22
…past their stated due date3
Years with a record 16 calendar years (1985–2006)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it25117 - Convention (Subpart B), Gross Ton
45574 - Dead Weight, Metric Ton
55974 - Displacement, Metric Ton
14003 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 38

28 April 2006 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2635911
17 October 2005 ISPS II Exam · COC-CHEM Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2514385
26 July 2004 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2146077
12 May 2004 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2066012
7 May 2004 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2061759
3 May 2004 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2058111
18 May 2002 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1618450
24 March 2002 Certificate of Compliance · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1597241
21 April 1998 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 415570
21 February 1998 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 413058
24 June 1997 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 404834
24 June 1997 Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1111669
19 November 1996 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 397680
25 June 1996 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 393725
25 June 1996 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1084284
24 June 1996 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 392706
24 June 1996 Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1402267
24 January 1994 Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1163147
29 December 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 517939
5 September 1992 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 934628
3 December 1991 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 347620
19 July 1991 Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1308469
31 December 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 340973
31 December 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 920864
25 June 1990 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 468783
5 June 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 332244
8 April 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 329594
8 April 1989 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 888762
9 January 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 455607
12 July 1988 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 457037
16 January 1988 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 320722
16 January 1988 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1015407
6 January 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 313689
6 January 1987 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1003780
20 May 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 309007
26 November 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 305635
12 May 1985 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 302185
4 March 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 301349

Deficiency record · 48

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 28 April 2006 Resolved
SOLAS 74 AMD REG I-11: PROVIDE CLASS REPORT OF REPAIRS TO THE CARGO PIPING CROSSOVER LINE, HYDRAULIC ACTIVATED LINE # 81 IN THE CARGO PUMP ROOM PRIOR TO NEXT US PORT AFTER SAILING FOREIGN.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 June 2010
Resolved 29 June 2010
Deck/Cargo › Ballast › Piping
Issued 28 April 2006 Resolved
SOLAS 74 AMD I-11: PROVIDE CLASS REPORT ATTESTING TO THE REPAIR OF BALLAST WATER PIPING IN THE CARGO PUMP ROMM PRIOR TO NEXT US PORT AFTER SAILING FOREIGN.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 June 2010
Resolved 29 June 2010
Engineering › Steering Gear System › Power Unit
Issued 17 October 2005 Resolved
Audible alarm for steering on the bridge is inoperable
Condition: Improper/Lack of Maintenance
Due 17 October 2005
Resolved 18 October 2005
Resolution: Steering alarm on bridge tested, found satisfactory
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 17 October 2005 Resolved
Vsl does not have on the bridge U.S. and International Navigation Rules
Condition: Improper/Lack of Maintenance
Due 17 October 2005
Resolved 18 October 2005
Resolution: Navigation rules International- Inland on board vsl
Engineering › Steering Gear System › Power Unit
Issued 17 October 2005 No resolution recorded
The audiible alarm indicator for the autopilot off-course steering alarm is found defective.
Condition: Improper/Lack of Maintenance
Due 17 October 2005 — due date passed with no resolution recorded
Operations/Management › Drills/Instruction › Not Conducted
Issued 17 October 2005 No resolution recorded
Vsl crew attendance list is missing for drills and exercises completed.
Condition: Improper/Lack of Maintenance
Due 17 October 2005 — due date passed with no resolution recorded
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 17 October 2005 Resolved
Vsl emergency generator will not start automatically
Condition: Improper/Lack of Maintenance
Due 17 October 2005
Resolved 18 October 2005
Resolution: Emergency generator cleared by class and COTP
Electrical › Electric Generation Source (service) › Panelboard
Issued 17 October 2005 Resolved
Vsl stbd ship service generator will not take load or parallel with port generator.
Condition: Improper/Lack of Maintenance
Due 17 October 2005
Resolved 18 October 2005
Resolution: Stbd ship service cleared by class and COTP
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 17 October 2005 No resolution recorded
Vsl's inert gas system, low flow scrubber shutdown was found inoperable.
Condition: Improper/Lack of Maintenance
Due 17 October 2005 — due date passed with no resolution recorded
Navigation › Piloting/Steering
Issued 12 May 2004 Resolved
VESSEL GYROCOMPASS INOPERABLE. TECHNICIANS ON VESSEL TO REPLACE. LEGACY COMPONENT DESC: Gyro Compass
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2004
Resolution: RECEIVED TECHNICIAN''S REPORT ATTESTING TO THE PROPER OPERATION OF THE GYROCOMPASS
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 3 May 2004 Resolved
Prove emergency shutdown of electric cargo pump. Pump is not to be used for cargo discharge operations until shutdown test has been completed by Safety Construction Certificate issuing authority. LEGACY COMPONENT DESC: Cargo Pump
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 May 2004
Resolved 7 May 2004
Resolution: RECEIVED CLASS REPORT ATTESTING TO THE EMERGENCY SHUTDOWN BEING TESTED AND FOUND SATISFACTORY
Communications › Audible Communications
Issued 3 May 2004 Resolved
Prove proper operation of phone system capability between bridge & steering gear space. To satisfaction of Safety Construction Certificate issuing authority. SOLAS 74/78 II-1/29.10. LEGACY COMPONENT DESC: SPD (Other)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 May 2004
Resolved 7 May 2004
Resolution: RECEIVED CLASS REPORT ATTESTING TO THE PHONE SYSTEM BETWEEN THE BRIDGE AND STEERING GEAR SPACE BEING TESTED AND FOUND SATISFACTORY
Deck/Cargo › Vapor Control Systems
Issued 3 May 2004 Resolved
Label "VAPOR" in 2-inch letters on VCS pipeline. 46 CFR 39. LEGACY COMPONENT DESC: Piping/Hoses
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 May 2004
Resolved 7 May 2004
Resolution: RECEIVED CLASS REPORT ATTESTING TO THE PROPER MARKING "VAPOR" ON THE VCS PIPELINE
Deck/Cargo › Vapor Control Systems
Issued 3 May 2004 Resolved
Provide stud through flange at 12 o'clock position for VCS line at manifold. 46 CFR 39. LEGACY COMPONENT DESC: Piping/Hoses
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 May 2004
Resolved 7 May 2004
Resolution: RECEIVED CLASS REPORT ATTESTING THAT A STUD THROUGH THE FLANGE IS NOW PROVIDED AT THE 12 O''CLOCK POSITION
Engineering › Shafting/Propeller Arrangements
Issued 3 May 2004 Resolved
Class society to address oil leak at shaft seal gravity tank serving propeller shaft. SOLAS 74/78 II-1/25-9. LEGACY COMPONENT DESC: Stern Tube Lubrication/Sealing
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 May 2004
Resolved 7 May 2004
Resolution: RECEIVED CLASS REPORT ATTESTING TO THE OIL LEAK AT THE SHAFT SEAL GRAVITY TANK HAS BEEN REPAIRED AND FOUND SATISFACTORY
Engineering › Steam System (auxiliary) › Piping
Issued 24 March 2002 Resolved
Sludge tank heating steam supply line holed, wasted and leaking. SOLAS 74A II-1/26
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2002
Resolved 27 March 2002
Resolution: Received class report satisfying requirement.
Pollution Prevention/Response › Prevention Equipment
Issued 24 March 2002 Resolved
Cargo pump emergency shut down at manifold and in cargo pumproom are inoperative. SOLAS 74A I/11 LEGACY COMPONENT DESC: Cargo Monitor/Control System
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2002
Resolved 27 March 2002
Resolution: Received class report satisfying requirement.
Pollution Prevention/Response › Prevention Equipment
Issued 24 March 2002 Resolved
Deck scuppers are wasted near accomodation ladder on port side and are unable to be plugged effectively. LEGACY COMPONENT DESC: Drains/Scuppers (means of closure)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2002
Resolved 27 March 2002
Resolution: Received class report satisfying requirement.
Pollution Prevention/Response › Prevention Equipment
Issued 24 March 2002 Resolved
Vessel's deck coaming is wasted near accomodation ladder port side and has a large 3" hole. 33 CFR 155.310 LEGACY COMPONENT DESC: Coamings
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2002
Resolved 27 March 2002
Resolution: Received class report approving temporary repair. Permanent repairs to be made on next voyage.
Electrical › Electric Generation Source (emergency)
Issued 24 March 2002 Resolved
Emergency generator is missing RPM tachometer. SOLAS 74A I/11 LEGACY COMPONENT DESC: Panelboard
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 April 2002
Resolved 27 March 2002
Resolution: Received class report satisfying requirement.
Engineering › Steering Gear System
Issued 24 March 2002 Resolved
No. 1 steering gear pump shaft seal has minor leak. Solas 74A I/11 LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2002
Resolved 27 March 2002
Resolution: Received class report satisfying requirement.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 24 March 2002 Resolved
Crankshaft seal on No. 1 and No. 2 generators have minor oil leaks. Solas 74A II-2/2 LEGACY COMPONENT DESC: Crankshaft
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2002
Resolved 27 March 2002
Resolution: Received class report satisfying requirement.
Pollution Prevention/Response › Prevention Equipment
Issued 24 March 2002 Resolved
Vessel's cargo is above the level at which the overfill alarms are set at. Vessel was loaded with Vacuum Gas Oil. 33 CFR 155.775 LEGACY COMPONENT DESC: Overfill Devices
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 March 2002
Resolved 27 March 2002
Resolution: Received class report satisfying requirement.
Pollution Prevention/Response › Prevention Equipment
Issued 24 March 2002 Resolved
Vessel could not demonstrate proper operation of overfill alarms because of the current level of cargo tanks. Prior to any cargo operation in U.S. waters, the vessel must demonstrate proper operation of overfill alarms. LEGACY COMPONENT DESC: Overfill Devices
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 March 2002
Resolved 18 May 2002
Resolution: Inspected vsl and conducted satisfactory test of overfill alarms.
Deck/Cargo
Issued 21 April 1998 Resolved
STEAM DRUM LOCATED BENEATH FORWARD MOORING WINCH IS CRACKED. VESSEL IS REQUIRED TO CORRECT THIS NON-ADHERENCE TO SOLAS 74 UNAMEMDED I/11 PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 21 May 1998
Resolved 25 March 2002
Resolution: All sat.
Lifesaving
Issued 21 February 1998 Resolved
Excessive water was in the port and starboard lifeboats thereby creating risk of sinking of said craft during deployment.
Condition: Unknown
Due 21 February 1998
Resolved 1 March 1998
Electrical
Issued 21 February 1998 Resolved
The light fixture in the Fitter's state room was not operable. ILO 147 requires adequate lighting in crew state rooms.
Condition: Unknown
Due 21 March 1998
Resolved 25 March 2002
Resolution: CG inspector observed all light fixtures on vessel. All sat.
Documentation
Issued 21 February 1998 Resolved
The line diagram for bunkering was not available in the control room oil transfer procedures. 33 CFR 155.720 and 155.750 requires this line diagramto be included in the vessel's oil transfer procedures. _x001C_ _x001C_
Condition: Unknown
Due 27 February 1998
Resolved 25 March 2002
Resolution: CG inspector observed line diagram of bunkering in cargo control room and in the transfer procedures.
Accommodation/Occupational Safety
Issued 24 June 1996 Resolved
Provide and utilize treatment chemicals for type II existing Marine Sanitation Device (MSD II) prior to next U.S. Port.
Condition: Unknown
Due 24 June 1996
Resolved 24 June 1996
Engineering
Issued 24 June 1996 Resolved
Replace flame screens on fore peak fuel vents prior to next U.S. Port.
Condition: Unknown
Due 24 June 1996
Resolved 24 June 1996
Deck/Cargo
Issued 24 June 1996 Resolved
Provide mechanical means of closure for cargo area (deck) containment. Existing plugs are not acceptable. Replace prior to next U.S Port.
Condition: Unknown
Due 24 June 1996
Resolved 24 June 1996
Navigation
Issued 31 December 1990 Resolved
VESSLE DID NOT HAVE USCG LIGHT LIST.
Condition: Unknown
Due 1 January 1991
Resolved 31 December 1990
Navigation
Issued 31 December 1990 Resolved
VESSLE DID NOT HAVE U.S. COAST PILOT.
Condition: Unknown
Due 1 January 1991
Resolved 31 December 1990
Navigation
Issued 31 December 1990 Resolved
VESSLE DID NOT HAVE BOSTON HARBOR OR BOSTON INNER HARBOR CHARTS.
Condition: Unknown
Due 1 January 1991
Resolved 31 December 1990
Navigation
Issued 8 April 1989 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 5 June 1989
Resolved 8 April 1989
Deck/Cargo
Issued 8 April 1989 Resolved
AS PER 46 CFR 153.216 LABEL EACH SHOWER/EYE WASH STATION.
Condition: Unknown
Due 8 April 1989
Resolved 8 April 1989
Deck/Cargo
Issued 8 April 1989 Resolved
MAKE EACH EYE WASH STATION AS PER 46 CFR 153.216.
Condition: Unknown
Due 8 April 1989
Resolved 8 April 1989
Navigation
Issued 16 January 1988 Resolved
VESSEL DID NOT HAVE A CURRENT (1988) EDITION OF THE TIDAL CURRENT TABLE ON BOARD.
Condition: Unknown
Due 16 January 1988
Resolved 16 January 1988
Navigation
Issued 16 January 1988 Resolved
VESSEL'S PRIMARY AND SECONDARY RADAR SYSTEMS WERE INOPERATIVE.
Condition: Unknown
Due 16 January 1988
Resolved 16 January 1988
Navigation
Issued 16 January 1988 Resolved
PRIOR TO DEPARTING PIER AT GATX, CARTERET, NJ, ONE RADAR MUST BE OPERATIONAL.
Condition: Unknown
Due 16 January 1988
Resolved 16 January 1988
Navigation
Issued 16 January 1988 Resolved
PRIOR TO DEPARTING THE PORT OF NEW YORK, BOTH RADAR UNITS MUST BE OPERATIONAL.
Condition: Unknown
Due 16 January 1988
Resolved 16 January 1988
Navigation
Issued 16 January 1988 Resolved
PRIOR TO DEPARTING THE PORT OF NEW YORK, A CURRENT TIDAL CURRENT TABLES BOOK MUST BE ON BOARD THE VESSEL.
Condition: Unknown
Due 16 January 1988
Resolved 16 January 1988
Navigation
Issued 6 January 1987 Resolved
CHART 12334 (86 EDITION) NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 6 January 1987
Resolved 6 January 1987
Deck/Cargo
Issued 6 January 1987 Resolved
VESSEL DID NOT HAVE A RECORD OF HYDROSTATICALLY TESTING CARGO PIPING TO ONEAND ONE HALF TIMES THE MAXIMUM ALLOWABLE WORKING PRESSURE.
Condition: Unknown
Due 6 January 1987
Resolved 6 January 1987
Deck/Cargo
Issued 6 January 1987 Resolved
TEST EMERGENCY SHUTDOWN SYSTEM PRIOR TO CARGO TRANSFER AT NEXT U.S. PORT.
Condition: Unknown
Due 6 January 1987
Resolved 6 January 1987
Documentation
Issued 26 November 1985 Resolved
MUST PROVIDE ONBOARD DUPLICATE SET OF FIRE CONTROL PLANS. PRIOR TO ENTRY NEXT U.S. PORT. (SOLAS REGULATION 20.2-CHAPTER II-2 1981 AMMEND.)
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Navigation
Issued 4 March 1985 Resolved
NO REQUIRED TESTS CONDUCTED PRIOR TO ENTERING U.S. WATERS. A VIOLATION OF 33 CFR 164.25 / 33 USC 1232
Condition: Unknown
Due 4 March 1985
Resolved 4 March 1985
Navigation
Issued 4 March 1985 Resolved
NO TIDAL CURRENT TABLES. 33 CFR 164.33(A)(3)(II) / 33 USC 1232
Condition: Unknown
Due 12 May 1985
Resolved 4 March 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.