MAURY USCG vessel records Sign in
← All vessels

CHAMPION VINCITA

CHAMPION VINCITA is a 1982 tank ship. The Coast Guard has recorded 30 inspections since 1984, most recently in December 2005, along with 46 deficiencies — 16 with no resolution recorded — and 2 operational controls.

Records from 1984 to 2005. Most recent: inspection, 5 December 2005.

Built
1982
Last inspected
5 December 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7920510 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228001
Flag
NORWAY
—
Maury page id
psix-228001

Inspections, by type

…with no type recorded17
…past their stated due date4
Years with a record 14 calendar years (1984–2005)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it25117 - Convention (Subpart B), Gross Ton
45574 - Dead Weight, Ton
50778 - Displacement, Ton
14003 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 30

5 December 2005 ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · COC-CHEM Annual · MARPOL Annex V Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2541276
4 November 2005 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2541194
5 December 2004 NPV Safety Exam · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2253471
24 November 2004 NPV Safety Exam · Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2247422
28 April 2003 Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1781992
18 December 2002 Certificate of Compliance · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1720812
22 June 1998 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 417611
22 June 1998 Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1131235
14 March 1997 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 401888
14 March 1997 Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1104301
28 August 1996 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 394981
11 March 1996 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 388937
11 March 1996 Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 884795
27 July 1994 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 141517
6 March 1994 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 498054
28 September 1993 Certificate of Compliance
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1132444
27 November 1990 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 340532
27 November 1990 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1211891
16 March 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 910840
6 November 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 333550
28 October 1988 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 326490
28 October 1988 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 891360
28 October 1988 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 891361
15 July 1988 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 324498
15 July 1988 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1032204
26 November 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 529672
8 June 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 316608
12 January 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 313703
12 January 1987 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1315293
25 October 1984 Type not recorded
No type recorded · COTP NEW HAVEN · USCG Northeast District (CGD-NE) · Activity 449267

Deficiency record · 46

Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 5 December 2005 Resolved
Vapor control marking on manifold Port and Starboard need to be painted.
Action required: 705 - Other - as specified
Due 5 January 2006
Resolved 14 November 2006
Resolution: Rcvd class report attesting to completetion of corrective action.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 5 December 2005 Resolved
Have class attest to the condition of the deck seal prior to use.
Action required: 705 - Other - as specified
Due 5 January 2006
Resolved 14 November 2006
Resolution: Rcvd class report attesting to completetion of corrective action.
Deck/Cargo › Crude Oil Washing Systems › Stripping System, Pressure/Vacuum Gauge
Issued 5 December 2005 Resolved
Have class attest to the condition of the PV Breaker prior to use.
Action required: 705 - Other - as specified
Due 5 January 2006
Resolved 14 November 2006
Resolution: Rcvd class report attesting to completetion of corrective action.
Construction/Loadline › Structures › Ventilators
Issued 5 December 2005 Resolved
Replace or repair flame screen on starboard side waste oil vent.
Action required: 705 - Other - as specified
Due 5 January 2006
Resolved 14 November 2006
Resolution: Rcvd class report attesting to completetion of corrective action.
Construction/Loadline › Structures › Ventilators
Issued 5 December 2005 Resolved
Replace or repair flame screen on service tank vent starboard side.
Action required: 705 - Other - as specified
Due 5 January 2006
Resolved 14 November 2006
Resolution: Rcvd class report attesting to completetion of corrective action.
Documentation › Logs/Records › Cargo Record Book (NLS)
Issued 5 December 2004 Resolved
Vessel's cargo record book not being completed on a tank to tank basis or during discharge into sea and during ballasting cargo tanks. Cite: Marpol Annex Reg. 9.2 viii.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 December 2004
Resolved 6 December 2004
Resolution: Received properly completed cargo record book pages via fax.
Documentation › Logs/Records › Cargo Record Book (NLS)
Issued 5 December 2004 Resolved
Each page of cargo record book not signed by master. Cite: Marpol Annex II Reg.5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 December 2004
Resolved 6 December 2004
Resolution: Recieved properly signed pages from master via fax.
Construction/Loadline › Markings › Load Line Mark
Issued 26 November 2004 No resolution recorded
PERMANENTLY AFFIX LOAD LINE MARKINGS ON BOTH SIDES OF THE HULL. ILLC 66 ANNEX 1/8
Action required: 705 - Other - as specified
Due 26 December 2004 — due date passed with no resolution recorded
Resolution: according to the sureyor loadline marks are carved in to the side of the vessel''s hull.
Construction/Loadline › Penetrations › Pipe Flange
Issued 26 November 2004 Resolved
MAKE PERMANENT REPAIRS TO LEAKING ANCHOR WASH PIPING ON PORT AND STARBOARD SIDE IN FORE PEAK. SOLAS II-I REG. 26
Action required: 705 - Other - as specified
Due 26 December 2004
Resolved 14 November 2006
Resolution: Rcvd class report attesting to completetion of corrective action.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 26 November 2004 No resolution recorded
AFFIX FIREMAN'S OUTFIT (FE) IMO SYMBOL ON FIRELOCKER WATERTIGHT DOOR LOCATED ON STBD SIDE POOPDECK. SOLAS II-2 REG. 24
Action required: 705 - Other - as specified
Due 26 December 2004 — due date passed with no resolution recorded
Resolution: Symbols have been permanetly affixed to the fire locker doors
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 26 November 2004 Resolved
UPDATE BALLAST WATER MANAGEMENT PLAN AND CERTIFICATE TO REFLECT CURRENT ADMINISTRATIVE INFORMATION. 33 CFR 151.2035 (a) (7)
Action required: 705 - Other - as specified
Due 26 December 2004
Resolved 14 November 2006
Resolution: Rcvd class report attesting to completetion of corrective action.
Lifesaving › Lifeboat › Hull
Issued 26 November 2004 Resolved
MAKE PERMANENT REPAIR TO #1 LIFEBOAT TEMPORARY FIBERGLASS REPAIR MADE OF PORT SIDE IWO GUNWALE. SOLAS III REG. 20
Action required: 705 - Other - as specified
Due 26 December 2004
Resolved 14 November 2006
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 26 November 2004 Resolved
OBTAIN AN INTERNATIONAL SHORE CONNECTION THAT MEETS THE SPECIFIC DIMENSIONS REQUIRED IN SOLAS II-2 REG. 19.3. SOLAS II-2 REG. 19.3
Action required: 705 - Other - as specified
Due 26 December 2004
Resolved 14 November 2006
Resolution: Rcvd class report attesting to completetion of corrective action.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 26 November 2004 No resolution recorded
PROVIDE A TECHNICIANS REPORT ATTESTING TO THE PROPER OPERATION OF THE ECHO DEPTH SOUNDER. 33 CFR 164/ SOLAS V/19.2.3.1
Action required: 17 - Rectify deficiencies prior to departure
Resolution: Transducer has been replaced and is in good working order.
Construction/Loadline › Hull › Hull Plating
Issued 26 November 2004 No resolution recorded
VERIFY WATERTIGHT INTEGRITY OF THE AFT PORTSIDE ACCESS HATCH, HATCH HAS EXCESSIVE CORRISION. ILLC 66 ANNEX 1/1
Action required: 17 - Rectify deficiencies prior to departure
Resolution: Water tight integrity of discussed garbage door satisfactory. Bottom of garbage locker cropped and inserted.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 26 November 2004 No resolution recorded
PROVIDE VAPOR CONTROL SYSTEM MANUAL IAW 46 CFR 39, 33 CFR 155.750 (d)
Action required: 705 - Other - as specified
Due 26 December 2004 — due date passed with no resolution recorded
Resolution: Existing vapor emission control manual sighted on board.
Engineering › Steering Gear System › Trunnion Block
Issued 26 November 2004 No resolution recorded
CONDUCT REPAIRS TO STEERING GEAR TRUNNION BEARINGS TOP AND BOTTOM DUE TO EXCESSIVE MOVEMENT. SOLAS II-1 REG. 29
Action required: 17 - Rectify deficiencies prior to departure
Resolution: Four new trunion bearing side block assemblies ordered. Conditions of class imposed for 3 months. Steering considered to remain efficient meanwhile.
Engineering › Steering Gear System › Pump
Issued 26 November 2004 No resolution recorded
CONDUCT REPAIRS TO #1 STEERING GEAR PUMP SYSTEM TO CORRECT RUDDER DRIFT TO STBD. SOLAS II-1 REG. 29
Action required: 17 - Rectify deficiencies prior to departure
Resolution: Replacement parts for stbd steering system to be ordered as recommended by manufacture. Condition of class imposed for 3 months. Steering system considered to remain efficient meanwhile.
Engineering › Steam System (main) › Piping
Issued 26 November 2004 No resolution recorded
CONDUCT REPAIRS TO STEAMLINE PORT SIDE MAIN DIESEL ENGINE LOCATED ON MAIN ENGINE FLAT. SOLAS II-1 REG. 26
Action required: 705 - Other - as specified
Resolution: Steam track pipe renewed as necessary.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 November 2004 No resolution recorded
REPAIR HANDRAILING LOCATED ON STBD SIDE AFT OF MAIN PROPELLER SHAFT. SOLAS II-1 REG. 26
Action required: 705 - Other - as specified
Due 26 December 2004 — due date passed with no resolution recorded
Resolution: Handrail rewelded.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 26 November 2004 No resolution recorded
CONDUCT REPAIR OF IGG DECK WATER SEAL UPPER WATER PIPE PORTSIDE AT FLANGE. SOLAS II-2 REG. 59.2, AND REG. 62
Action required: 17 - Rectify deficiencies prior to departure
Resolution: Steam line to deck water seal rewelded.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 26 November 2004 No resolution recorded
PROVE PROPER OPERATION OF ODME. SOLAS II-2 REG. 59
Action required: 17 - Rectify deficiencies prior to departure
Resolution: Operation of ODME verified by simulation procedure in operation manual
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 26 November 2004 No resolution recorded
PROVIDE ONBOARD SUFFICIENT DRAGER PUMPS. SOLAS II-2 REG. 59
Action required: 17 - Rectify deficiencies prior to departure
Resolution: To drager pumps found onboard in working condition.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 26 November 2004 No resolution recorded
CONDUCT FULL FUNCTION TEST OF INERT GAS GENERTOR SYSTEM. SOLAS II-2 REG. 59 AND 62
Action required: 17 - Rectify deficiencies prior to departure
Resolution: Functional test of inert gas generator system satisfactory.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 26 November 2004 No resolution recorded
CONDUCT REPAIRS TO THE #2 CARGO PUMP EMERGENCY SHUT DOWNS LOCATED AT THE CARGO MANIFOLD PORT AND STBD SIDES AND AT THE CARGO MONITOR CONTROL ROOM. SOLAS II-2 REG.63
Action required: 17 - Rectify deficiencies prior to departure
Resolution: All engineering stops for No. 2 cargo pump operational.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 26 November 2004 No resolution recorded
CONDUCT REPAIRS TO #2 CARGO PUMP CONTROL PANEL. SOLAS II-2 REG. 63
Action required: 17 - Rectify deficiencies prior to departure
Resolution: No. 2 cargo pump control panel pressure guage renewed.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 26 November 2004 No resolution recorded
CONDUCT FULL FUNCTION TEST OF CARGO TANKS HIGH AND HIGH HIGH LEVEL ALARMS. SOLAS II-2 REG. 59.1.6
Action required: 17 - Rectify deficiencies prior to departure
Resolution: Cargo tank high and high high level alarms tested satisfactorily.
Electrical › Electrical Distribution System (service)
Issued 18 December 2002 Resolved
The starboard steering gear controller is missing the main power switch knob. LEGACY COMPONENT DESC: Steering Gear Controller
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 January 2003
Resolved 28 April 2003
Resolution: Received proper documentation satisfying requirement.
Navigation
Issued 22 June 1998 Resolved
No evidence exists that the vessels maneuvering performance capability has been verified by flag administration or classification society. Provide evidence as per 33CFR157.445/IMO Resolution A.751(18).
Condition: Unknown
Due 6 December 2000
Resolved 6 December 2000
Deck/Cargo
Issued 22 June 1998 Resolved
The cargo tanks were not inerted as required 46CFR32.53-5._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Construction/Loadline
Issued 22 June 1998 Resolved
Ballast tanks and pump room not available for inspection, make tanks and pump room available for inspection at first U.S. port outside of Micronesia, as per SOLAS 74 (amended) I/19.
Condition: Unknown
Due 23 July 1998
Resolved 6 July 1998
Documentation
Issued 22 June 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 December 2000
Resolved 6 December 2000
Fire Fighting
Issued 22 June 1998 Resolved
Stairwell self closing fire doors do not properly close, repair as per SOLAS 74 II-2/57.
Condition: Unknown
Due 6 December 2000
Resolved 6 December 2000
Electrical
Issued 22 June 1998 Resolved
The electrical communication speaker, with warning in German at the main deck oil transfer station, is not used in accordance with suggested manufactures instructions/warnings. Provide evidence that the speaker is being used in accordance with label, as required by SOLAS 74 II-1/27.
Condition: Unknown
Due 6 December 2000
Resolved 6 December 2000
Documentation
Issued 22 June 1998 Resolved
No documentary evidence exists to confirm that the vessel has completeted asatisfactory enhanced survey during last dry dock in June 1998, provide evidence as required by 33CFR157.430/IMO Res. A.744.18
Condition: Unknown
Due 6 December 2000
Resolved 6 December 2000
Navigation
Issued 22 June 1998 Resolved
There is no audible and visual alarm on the bridge that will activate if the helm is manually moved while the autopilot is engaged, correct as per 33CFR157.440.
Condition: Unknown
Due 6 December 2000
Resolved 6 December 2000
Deck/Cargo
Issued 16 March 1990 Resolved
PROVE PROPER OPERATIONS OF INERT GAS GENERATING SYSTEM PRIOR TO CARGO OPERATIONS IN U.S WATERS.
Condition: Unknown
Due 16 March 1990
Resolved 16 March 1990
Deck/Cargo
Issued 16 March 1990 Resolved
PROVE PROPER OPERATIONS OF EMERGENCY SHUTDOWNS PRIOR TO CARGO OPERATIONS INU.S. WATERS.
Condition: Unknown
Due 16 March 1990
Resolved 16 March 1990
Fire Fighting
Issued 28 October 1988 Resolved
PROVIDE EVIDENCE THAT THE PRESENT NON-STEEL CORED FIREFIGHTING LIFELINE IS EQUAL TO OR GREATER THAN THE STEEL CORED LIFELINE REFERRED TO IN THE BCH CODE REGULATION 3.16.5(C).
Condition: Unknown
Due 28 October 1988
Resolved 28 October 1988
Navigation
Issued 15 July 1988 Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITHOUT HAVING HAD CHART 12326 ON BOARD
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Navigation
Issued 15 July 1988 Resolved
CHART 12331 (ED.23) WAS NOT CORRRRECTED UP TO DATE THROUGH THE LATEST NOTICE TO MARINERS.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Navigation
Issued 15 July 1988 Resolved
VESSEL HAD UNACCEPTABLE GERMAN ADMIRALTY LIGHT LIST, COAST PILOT AND TIDE TABLES ON BOARD.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Navigation
Issued 15 July 1988 Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITH NO TIDAL CURRENT TABLES ON BOARD.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Documentation
Issued 12 January 1987 Resolved
VESSEL COULD NOT PRODUCE A RECORD OF A HYDROSTATIC PRESSURE TEST OF CARGO PIPING CONDUCTED WITHIN THE LAST YEAR.
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Navigation
Issued 12 January 1987 Resolved
VESSEL'S SECONDARY RADAR SYSTEM INOPERATIVE.
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Deck/Cargo
Issued 12 January 1987 Resolved
REPAIR INOPERATIVE OIL DISCHARGE BALLAST MONITOR AT UPCOMING DRYDOCKING PERIOD (FEBRARY/MARCH 1987). UNTIL REPAIRED ALL TANK WASHINGS MUST BE DISCHARGED TO A RECEPTION FACILITY ASHORE WHEN OPERATING.
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.