Records from 1984 to 2008. Most recent: operational control imposed, 10 April 2008.
Inspection history · 56
9 April 2008
Ballast Water Examination · Deficiency Check · PII Safety Exam · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3180397
9 April 2008
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3181093
13 February 2005
ISPS II Exam · Ballast Water Examination · NPV Safety Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2291430
15 April 2004
Administrative Inspection
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2044808
16 April 2003
Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1773335
20 April 2002
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1605414
3 January 2001
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 285727
21 July 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 279826
22 October 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 434414
16 August 1999
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 87650
3 August 1999
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 431384
27 May 1999
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 429098
1 April 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 426918
30 November 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 423092
24 November 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 423147
22 October 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 421703
22 October 1998
Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 801346
9 September 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 407356
10 February 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 487001
21 May 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 391823
18 May 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 392169
6 October 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 383622
9 August 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 381499
21 May 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 133863
16 May 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 378443
21 January 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 374514
11 October 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 521936
18 February 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 364472
7 December 1993
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 848493
21 April 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 357614
2 March 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 356546
14 November 1992
Certificate of Compliance
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1133403
19 February 1992
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1261030
8 December 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 347493
8 December 1991
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1453967
1 October 1991
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 346543
5 December 1990
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1223680
30 November 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 903421
26 November 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 340511
26 November 1990
Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 914945
14 July 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 485021
31 October 1989
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1032849
7 May 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1205704
24 January 1989
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1209886
7 December 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 457911
5 December 1988
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 898025
14 July 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 324483
5 April 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 322421
27 November 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 462671
27 November 1987
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1031644
5 April 1987
Type not recorded
No type recorded · COTP NEW HAVEN · USCG Northeast District (CGD-NE) · Activity 501601
11 February 1987
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 538835
9 July 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1298864
8 July 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 310423
14 May 1985
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 476082
20 September 1984
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 462766
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 22 April 2008
Resolved
74SOLAS(amended) I/11 ILLC 66 Annex I/14 During def. check found hydraulic fluid leaks in numerous areas. This failure prevents the hydraulic system from proper operation and presents a pollution hazard. Class is to attest to proper repairs, system operation and clean up of spilled hydraulic fluid, and satisfaction of the U.S. Coast guard. (see scanned form b for further details)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2008
Resolution: CG inspectors attended vessel, and were able to prove proper operation an clean up of hydraulic system. Def. Cleared.
Deck/Cargo › Ballast › Valves
Issued 22 April 2008
Resolved
ILLC 66 Annex I/1 Drains for top wing tanks numbered 3 and 4, starboard side continue to leak ballast water past the valves, unable to properly seat valves in closed position. Class to attest to proper function proving watertight integrity, of these valves. To the satisfaction of Class/RO/RSO
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2008
Resolution: Class issued a condition of class clearing deficiency.
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 9 April 2008
Resolved
ILLC 66 Annex I/1 Top side tank #1 starboard is leaking into cargo hold #1 at the cargo hold boundary causing water to accumulate in the cargo hold. Make repairs and prove integrity of Top side tand#1 to the satisfaction of class prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2008
Resolution: Holed welded and pressure tested. Received class report.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 9 April 2008
Resolved
74SOLAS (Amended) I/1 The main inlet pipe to the MSD Type II has ruptured resulting in wide spread release of raw sewage on the starboard side of engine room second deck, cascading to the generator flat presenting a significant hazard in way of unsanitary conditions. Make repairs and clean spill to the satisfaction of class and USCG, Prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2008
Resolution: Approx. 30 cm x 30 cm dia piping cropped and renewed, received class report. All found sat.
Engineering › Bilge Water Management System › Interface Detector
Issued 9 April 2008
Resolved
74SOLAS(2004 Cons.) XII/12.1.3 (all ships) The water ingress detection system appears to be inoperative. The floats in the lower bosun stores were tested with negative results. Prove proper operation prior to departure. To the satisfaction of class RO/RSO.
Action required: 705 - Other - as specified
Resolved 13 April 2008
Resolution: Received class report and tested to satisfaction of attending USCG PSCO.
Construction/Loadline › Penetrations › Pipe Flange
Issued 9 April 2008
Resolved
ILLC 66 Annex I/18 The threads for the on deck top side tank sounding opening caps are wasted, inoperative, and no longer weather tight. Make repairs and prove proper operation to class prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2008
Resolution: 16 caps renewed. Received class report.
Operations/Management › Drills/Instruction › Fire
Issued 9 April 2008
Resolved
74SOLAS (2004 Cons) XI 1/4 (all ships) 74SOLAS (2004 Cons)74SOLAS (2004 Cons) IX/3.1 (all ships) ISM Code 1.4.5 Vessel's crew failed to properly demonstrate the tactics required to control and extinguish a fire while performing a drill in the paint locker in the presence of USCG PSCOs. Vessel is to perform fire drill to the satisfaction of the R.O. and USCG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2008
Resolution: Completed satisfactory fire drill.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 9 April 2008
Resolved
ILLC 66 Annex I/14 74 SOLAS (Amended) I/11 Significant damage in hatch covers #6 port and starboard present a significant risk of water accumulation in cargo hold #6. #6 starboard has approx. 4-5 ft in dent with through cracking and #6 port has an approx. 1/2 X1ft through hole. Vessel is to make repairs and prove integrity of the hatch to Class and RSO.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2008
Resolution: Class attested to damage in hatch covers #6 port and starboard. Def. Cleared.
Lifesaving › Lifeboat › Canopy
Issued 9 April 2008
Resolved
74SOLAS(2004 Cons.) III/20.2 The lifeboat's remote lowering wires have been removed from the inside of both totally enclosed lifeboats. Plugs are frozen in place requiring an alternate means of operation. make repairs and prove operational readiness of remote lowering wires to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2008
Resolution: Wires put in place. Received class report.
Engineering › Steam Turbine (auxiliary) › Steam Chest
Issued 9 April 2008
Resolved
74OSOLAS(Amended) I/1 Vessel's steam turbine generator has a steam leak. operational status of turbine in question. Class to attest to proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2008
Resolution: Steam turbine found sat. Class report received.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 9 April 2008
Resolved
74SOLAS(Amended)I/1 ILLC 66 Annex I/14 Class to attest to the suitability of all on deck hydraulic lines and equipment required for the operation and securing of hatch covers. Leaking presents a pollution risk and suggests an unsuitability of the hatch covers to provide weather tight integrity of cargo hold. Prior to departure. Conditions of Class set for 6/12 and 10/22
Action required: 705 - Other - as specified
Due 12 June 2008
Resolved 22 April 2008
Resolution: Class attested to the suitability of all deck hydraulic lines. Def. cleared.
Deck/Cargo › Ballast › Valves
Issued 9 April 2008
Resolved
ILLC 66 Annex I/1 The drains for top wing tanks #3 and #4 starboard are leaking water (ballast) from the valves. the crew has been unsuccessful in their attempts to properly seat these valves(closed). Make repairs and prove watertight integrity to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2008
Resolution: Valves repaired. Received class report.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 9 April 2008
Resolved
ILLC 66 Annex I/1 Cracks found in cargo hatch coaming supports; hatch #5 port side aft (4-5 inch), #5 port side forward, and #3 portside forward. Class to attest to the integrity of cargo hold coaming supports .
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2008
Resolution: Cracks gouged and welded. Class report received.
Lifesaving › Lifeboat › Hull
Issued 9 April 2008
Resolved
74SOLAS(Amended) I/1 Patches and temporary repairs found in the port life boat canopy aft in way of the locking hook for the after fall. Class to attest to suitability of lifeboat repair prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2008
Resolution: Repairs made. Class report received.
Lifesaving › Lifeboat Equipment › Binnacle/Compass
Issued 9 April 2008
Resolved
74SOLAS(amended) III/11(a)(vii) The magnetic compass in the starboard side lifeboat is approx. 50 degrees off of actual heading. Class to attest to proper operation of compass in the STBD side lifeboat prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2008
Resolution: Magnetic compass found operating sat. Class report received.
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 9 April 2008
Resolved
74SOLAS(2004 Cons.) I/12(a)(iii) The vessel's record of equipment for the cargo ship safety equipment certificate (form E). Has been amended to reflect the total # of persons for which life-saving appliances are provided. The life boats are marked 35 persons. Class to attest to the total # of persons accommodated by the life boats on the form E.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2008
Resolution: Received class report, certificate has been amended to reflect 35 persons.
Electrical › Electric Generation Source (service) › Generator
Issued 9 April 2008
Resolved
74SOLAS(2004 Amended)I/11 Accumulation of oil under the starboard side ship service diesel generator (SSDG) creating a possible hazard. Class to attest to removal of excess oil from SSDG.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 April 2008
Resolution: Leaks rectified and cleaned. Class report received.
Deck/Cargo › Holds/Tanks › Scuttle
Issued 9 April 2008
Resolved
74SOLAS (amended) I/11 The ladders and stairways leading to the cargo hold bottoms are wasted and warped creating an unsafe condition/ Make repairs to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 April 2008
Resolution: Class attested to the repairs of cargo hold bottoms. Def. cleared.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 9 April 2008
Resolved
74SOLAS (amended) I/11 wood plugs found in "cargo" piping on deck port side in way of manifold. Crew reports that this piping is obsolete but cannot provide documentary proof nor accurate description of piping's purpose. Class to attest to proper repair or report on purpose and status of piping in question.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 April 2008
Resolution: Wooden plug removed and welded. Received class report.
Engineering › Steam System (auxiliary) › Lagging/Insulation
Issued 9 April 2008
Resolved
74SOLAS (amended)I/11 Oil soaked lagging found in way of boiler (port side) overhead. Class to attest to renewal of and proper replacement of oil soaked lagging.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 April 2008
Resolution: Lagging renewed. Class report received.
Construction/Loadline › Markings › Load Line Mark
Issued 9 April 2008
Resolved
ILLC66 Annex I/8 The rings. lines, and letters associated with the starboard side load line marks are not clearly visible. The lines and marks are to be permanently affixed and painted white or yellow on a dark ground to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 April 2008
Resolution: LL markings made. Class report received.
Lifesaving › Lifefloat › Lifeline
Issued 9 April 2008
Resolved
74SOLAS (2004 Cons) III/31.1.1.1.2 LSA Code 4.2.6.3.7&.8 the port side life raft containers (2) are not marked with the length of the painter nor the maximum permitted eight of stowage above the waterline. Mark to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 April 2008
Resolution: Markings made. Class report Received.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 9 April 2008
Resolved
74SOLAS (2004Cons.) XI-2(all ships) ISPS Code part A 9.8.1 Vessel presented USCG PSCOs with confidential portions of the SSP. The provisions of the plan relating to these subsections (9.4.7 & 9.4.18) are considered confidential information. RSO is to attest to the proper training of crew in respect to protecting the confidential portions of the SSP.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 April 2008
Resolution: RSO attested to proper training of crew. Def. cleared.
Lifesaving › Inflatable Liferafts › Container Construction
Issued 9 April 2008
Resolved
74SOLAS (2004 Cons;) II/31.1.1.2 LSA Code 4.2&4.1.6 The life raft on the starboard side aft was found stowed in a non-float free arrangement as the painter was secured to the life raft bracket and not to the weak link. Make repair to the float free arrangement and demonstrate operation readiness prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2008
Resolution: U.S.C.G witnessed proper repair to the float free arrangement and demonstrated operational readiness.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 9 April 2008
Resolved
74SOLAS(2004 Cons.) II-2/14.2.1.1.1 (all ships) the self closing fire door is the engine control room (ECR) was found inoperative as it would not latch properly. Make repairs and prove proper operation prior to departure.
Action required: 705 - Other - as specified
Resolved 10 April 2008
Resolution: Vessel proved proper operation of the self closing fire door, to the attending CG marine inspectors.
Deck/Cargo
Issued 22 October 1999
Resolved
Prove proper operation of high level & overfill audible alarms prior to loading liquid cargoes and provide documentation from certificate issuing authority to U. S. Coast Guard IAW 33CFR155.480(d).
Condition: Unknown
Due 21 July 2000
Resolved 21 July 2000
Deck/Cargo
Issued 24 November 1998
Resolved
VESSEL TO SHOW PROOF OF PERMANENT REPAIRS TO ALL CARGO TANKS INWAY OF THE REMOVAL OF THE OLD CARGO LEVEL DEVICE AND CLOSURE OF HOLE.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Navigation
Issued 22 October 1998
Resolved
MANEUVERING FACT SHEET IS INCOMPLETE. 33CFR157.450
Condition: Unknown
Due 8 December 1999
Resolved 8 December 1999
Accommodation/Occupational Safety
Issued 22 October 1998
Resolved
VENTILATION IN PUMP ROOM RUSTED AND NOT CONNECTED IN SECTIONS.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Lifesaving
Issued 18 May 1996
Resolved
Inspect or replace all lights on PFDs prior to next US port.
Condition: Unknown
Due 11 February 1997
Resolved 11 February 1997
Engineering
Issued 9 August 1995
Resolved
REPAIR/REPLACE AUDIBLE ALARM FOR 15 PPM OILY WATER SEPARATOR.
Condition: Unknown
Due 9 October 1995
Resolved 9 October 1995
Accommodation/Occupational Safety
Issued 9 August 1995
Resolved
REPAIR BROKEN HAND/GUARD RAILS IN LOWER ENGINE ROOM NEAR OILY WATER SEPARATOR AS PER ILO 147.
Condition: Unknown
Due 9 October 1995
Resolved 9 October 1995
Deck/Cargo
Issued 21 January 1995
Resolved
FOUND CRACK 1" CRACK IN #2 CARGO PUMP CASING. PUMP LEAKING CARGO. PUMP WAS DRAINED AND VALVES TO SUCTION SIDE WERE CLOSED AND DISCHARGE SIDE WAS BLANKED OFF.
Condition: Unknown
Due 16 May 1995
Resolved 16 May 1995
Deck/Cargo
Issued 8 December 1991
Resolved
MAKE PERMANENT REPAIRS TO #6 OPERATING HANDLE ON #6 CARGO TANK P.V. VALVE.
Condition: Unknown
Due 8 December 1991
Resolved 8 December 1991
Deck/Cargo
Issued 26 November 1990
Resolved
CALIBRATION GAS FOR O2 METER, WAS NOT MARKED WITH PERCENTAGE OF OXYGEN ADDED FOR CALIBRATION PURPOSE. VESSEL WILL NEED TO REFILL OR FIND THE PAPERWORK FOR THE GAS.
Condition: Unknown
Due 26 November 1990
Resolved 26 November 1990
Deck/Cargo
Issued 26 November 1990
Resolved
ALARM FOR GAS MAIN LOW PRESSURE ON THE IGS MALFUNCTIONING. VESSEL WILL NEED TO REPAIR LOW PRESSURE ALARM.
Condition: Unknown
Due 26 November 1990
Resolved 26 November 1990
Deck/Cargo
Issued 7 May 1989
Resolved
DAMAGED PORTION OF DISCHARGE PIPE IN PUMP ROOM FOR CARGO PUMP #1 TO BE RE- PLACED.
Condition: Unknown
Due 7 May 1989
Resolved 7 May 1989
Electrical
Issued 7 May 1989
Resolved
LIGHTING & ELECTRICAL CABLES AND OTHER INSTRUMENTATION IN PUMP ROOM TO BE INSPECTED FOR FIRE DAMAGE & REPAIRED AS NECESSARY.
Condition: Unknown
Due 7 May 1989
Resolved 7 May 1989
Deck/Cargo
Issued 7 May 1989
Resolved
CARGO PUMP #1 TO BE OPENED & INSP FOR DAMAGE # TO DETERMINE CAUSE OF SEIZ- URE DURING OPERATION.
Condition: Unknown
Due 7 May 1989
Resolved 7 May 1989
Deck/Cargo
Issued 7 May 1989
Resolved
DRIVE SHAFT ARRANGEMENT FOR CARGO PUMP #1 TO BE REPAIRED.
Condition: Unknown
Due 7 May 1989
Resolved 7 May 1989
Deck/Cargo
Issued 5 December 1988
Resolved
PRIOR TO CARRYING BULK LIQUID CARGO IN U.S. PORTS IN NUMBER TWO, FOUR AND FIVE CARGO TANKS, MAKE PERMANENT REPAIRS TO HIGH LEVEL ALARMS AND PROVE SATISFACTORY OPERATION OF THE SAME TO THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 5 December 1988
Resolved 5 December 1988