MAURY USCG vessel records Sign in
← All vessels

STRIMON

STRIMON is a 1981 tank ship. The Coast Guard has recorded 65 inspections since 1984, most recently in March 2003, along with 41 deficiencies and 2 operational controls.

Records from 1984 to 2003. Most recent: inspection, 25 March 2003.

Built
1981
Last inspected
25 March 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7924994 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228041
Flag
PANAMA
—
Maury page id
psix-228041

Inspections, by type

…with no type recorded53
Years with a record 20 calendar years (1984–2003)
The 65 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it48037 - Convention (Subpart B), Gross Ton
79997 - Dead Weight, Ton
25374 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 65

25 March 2003 Administrative Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1762669
19 September 2002 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1677604
25 March 2002 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1496071
14 September 2001 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 293665
4 September 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 293538
3 September 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 293535
3 July 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 279577
15 October 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 433852
28 July 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 431214
2 July 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 430329
6 July 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 417920
22 September 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 408079
9 June 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 404530
4 May 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 403182
4 May 1997 Tank Vessel Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1099317
17 April 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 402413
30 January 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 399977
7 May 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 390865
11 December 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 385621
20 April 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 377504
13 August 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 369347
12 April 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 538984
18 February 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 364723
1 February 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1422330
26 October 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 652569
6 October 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 361280
6 October 1993 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1460661
29 July 1993 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 359805
28 June 1993 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 359130
3 March 1993 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 356664
22 February 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 691484
11 February 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 493955
13 October 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 353667
25 September 1992 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 353510
17 July 1992 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 652570
19 June 1992 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 158694
1 May 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 350348
14 March 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 458424
24 January 1992 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 348462
21 September 1991 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 345965
4 April 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 479048
3 October 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 339707
15 March 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 515990
18 October 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 333083
18 October 1989 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 888113
3 May 1989 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 473464
25 October 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 326398
25 October 1988 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1199314
4 August 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 468009
3 December 1987 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 508545
28 October 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 319290
28 October 1987 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1020186
28 October 1987 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1326622
8 April 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 534453
4 September 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1000366
2 September 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 311236
4 April 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 509786
22 November 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 472518
12 October 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1302133
11 October 1985 Examination of Repairs
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 985579
7 October 1985 Damage Survey
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1302136
24 June 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 302768
13 November 1984 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 299188
4 September 1984 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 297688
11 May 1984 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 296342

Deficiency record · 41

Construction/Loadline
Issued 19 September 2002 Resolved
Effect permanent repairs to soft patched main ballast piping to the satisfaction of class prior to 19OCT02. ILLC Reg 22
Action required: 705 - Other - as specified
Due 19 October 2002
Resolved 25 March 2003
Resolution: Received class report from ABS satisfying requirement.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 19 September 2002 Resolved
Effect permanent repairs to cargo piping stripping pump vent lines (soft patches). SOLAS 74 Ch I, Reg 11 LEGACY COMPONENT DESC: Cargo Pump
Action required: 705 - Other - as specified
Due 19 October 2002
Resolved 20 October 2002
Resolution: Corrected - MSO Corpus Christi received ABS Report # NO291863 - submitted by ABS surveyor [name withheld] attesting to observing satisfactory operation of permanent repairs to cargo piping stripping pump vent lines.
Deck/Cargo › Inert Gas System
Issued 19 September 2002 Resolved
Effect permanent repairs to soft patched IGS drain line main IGS piping. SOLAS 74 Ch II-2 Reg 62.
Action required: 705 - Other - as specified
Due 19 October 2002
Resolved 20 October 2002
Resolution: Corrected - MSO Corpus Christi received ABS Report # NO291863 - submitted by ABS surveyor [name withheld] attesting to observing satisfactory operation of permanent repairs to IGS drain line main IGS piping.
Deck/Cargo › Inert Gas System
Issued 19 September 2002 Resolved
Prove proper operation of permanent IGS oxygen analyser prior to next U.S. port and prior to discharging. Class to provide OCMI with report verifying compliance. SOLAS 74 Ch II-2 Reg 62
Action required: 15 - Rectify deficiencies by next port
Resolved 20 September 2002
Resolution: Corrected - MSO Corpus Christi received ABS Report # CX 283 895 - A submitted by ABS surveyor [name withheld] attesting to observing satisfactory operation of permanent IGS oxygen analyser.
Accommodation/Occupational Safety
Issued 4 September 2001 Resolved
FRESH HOT AND COLD WATER SUPPLY CONTAMINATED WITH RUST IN SEVERAL FREQUENTLY USED LOCATIONS. (COMDTINST 16711.12a, ILO 147) _x001C_ CORRECT PRIOR TO RETURN FROM SAILING FORIEGN.
Condition: Unknown
Due 4 October 2001
Resolved 25 March 2002
Resolution: Item corrected.
Lifesaving
Issued 3 September 2001 Resolved
Cargo Pump room not inspected due to no gas free certificate.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Fire Fighting
Issued 3 September 2001 Resolved
Ship failed fire drill, due to weak space entry, and no attempt to isolate.
Condition: Unknown
Due 6 September 2001
Resolved 6 September 2001
Deck/Cargo
Issued 2 July 1999 Resolved
MAKE TEMP REPAIRS TO SCRUBBER PRECOOLER IAW CLASS RECOMMENDATION. MAKE PERMANENT REPAIRS IAW CLASS RECOMMENDATION.
Condition: Unknown
Due 18 October 1999
Resolved 18 October 1999
Lifesaving
Issued 2 July 1999 Resolved
REPAIR ALL EMERGENCY ESCAPE HANDLES ON VESSEL'S 3 FREEZER DOORS.
Condition: Unknown
Due 18 October 1999
Resolved 18 October 1999
Documentation
Issued 4 May 1997 Resolved
OFFICERS LICENSES NEED STCW ENDORSEMENTS.
Condition: Unknown
Due 23 September 1997
Resolved 23 September 1997
Lifesaving
Issued 4 May 1997 Resolved
THE STRONGBACKS ON THE PORT AND STARBORD DAVITS HAD EXCESSIVE WASTAGE.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Construction/Loadline
Issued 4 May 1997 Resolved
LOADLINE NOT PAINTED WITH CONTRASTING COLOR, IAW ILLC 66 ANNEX I/8
Condition: Unknown
Due 10 June 1997
Resolved 10 June 1997
Lifesaving
Issued 30 January 1997 Resolved
PORT SIDE LIGHTED LIFE BUOY NEAR LIFEBOAT NOT ILLUMINATING AS REQUIRED BY SOLAS 74 CHAP III REG 7.1.3. CORRECTED ON SCENE.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Lifesaving
Issued 30 January 1997 Resolved
VESSELS PORT EMBARKATION LADDER WAS NOT SECURED TO THE SHIP AS REQUIRED BY SOLAS 74 CHAP III REG 18.7. CORRECTED ON SCENE.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Navigation
Issued 20 April 1995 Resolved
REPAIR/PROVE OPERATION OF ALL STEERING GEAR ALARMS. SOLAS 74(AMENDED) II-1/29.5.2
Condition: Unknown
Due 21 May 1995
Resolved 21 May 1995
Fire Fighting
Issued 20 April 1995 Resolved
RENEW DETERIORATED/HOLED FIRE MAIN PIPING ON MAIN DECK._x001C_ SOLAS 74(AMENDED) II-2/21.
Condition: Unknown
Due 21 May 1995
Resolved 21 May 1995
Deck/Cargo
Issued 20 April 1995 Resolved
PROVIDE OPERATIONAL TEST OF INERT GAS SYSTEM AUDIBLE AND VISUAL ALARMS. _x001C_ SOLAS 74 II-2/62.19.3-19.7
Condition: Unknown
Due 21 May 1995
Resolved 21 May 1995
Deck/Cargo
Issued 20 April 1995 Resolved
PROVE OPERATION OF ENTIRE INERT GAS SYSTEM TO THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR. SOLAS 74(AMENDED) II-2/62
Condition: Unknown
Due 21 May 1995
Resolved 21 May 1995
Documentation
Issued 20 April 1995 Resolved
PROVIDE VALID SAFETY EQUIPMENT CERTIFICATE ISSUED BY FLAG ADMINISTRATION. SOLAS 74(AMENDED) I/12
Condition: Unknown
Due 21 May 1995
Resolved 21 May 1995
Documentation
Issued 6 October 1993 Resolved
VESSELS OIL RECORED BOOK WAS INCOMPLETE DUE TO NO SIGNATURES OF EACH OPERATION CONDUCTED BY THE PERSON IN CHARGE.
Condition: Unknown
Due 6 October 1993
Resolved 18 October 1993
Construction/Loadline
Issued 6 October 1993 Resolved
VESSEL ENTERED PORT WITH INOPERABLE OILY WATER SEPARATOR.
Condition: Unknown
Due 6 October 1993
Resolved 14 October 1993
Documentation
Issued 3 March 1993 Resolved
REQUIRED SECTIONS OF VESSEL RESPONSE PLAN, AS OUTLINED IN SECTION 6 (d) OF NVIC 8-92, NOT CARRIED ON BOARD VESSEL.
Condition: Unknown
Due 29 July 1993
Resolved 29 July 1993
Deck/Cargo
Issued 21 September 1991 Resolved
PROVIDE ONBOARD A COMPLETE IGS MANUAL FOR VESSELS SYSTEM.
Condition: Unknown
Due 21 September 1991
Resolved 25 September 1991
Deck/Cargo
Issued 21 September 1991 Resolved
MAKE PERMANENT REPAIRS TO IGS INDICATOR LIGHTS ON IGS CONTROL BOARDS IN_x001C_ CARGO CONTROL ROOM.
Condition: Unknown
Due 21 September 1991
Resolved 25 September 1991
Accommodation/Occupational Safety
Issued 21 September 1991 Resolved
HAVE CHEMICALS FOR MSD AND PROPERLY OPERATING MSD PRIOR TO NEXT US. PORT CALL.
Condition: Unknown
Due 16 October 1991
Resolved 16 October 1991
Deck/Cargo
Issued 21 September 1991 Resolved
MAKE PERMANENT REPAIRS TO THE TEMP CONTROL FOR RAW WATER HEATER FOR TANK CLEANING.
Condition: Unknown
Due 16 October 1991
Resolved 16 October 1991
Fire Fighting
Issued 21 September 1991 Resolved
INSTALL ALL FIREMANS OUTFIT AND EQUIPMENT IN PUMPROOM FIREMANS STATION.
Condition: Unknown
Due 16 October 1991
Resolved 16 October 1991
Documentation
Issued 21 September 1991 Resolved
HAVE MSDS OR CARGO INFORMATION CARDS ONBOARD FOR PRODUCTS CARRIED PRIOR TO BUNKERING NEXT US. PORT.
Condition: Unknown
Due 16 October 1991
Resolved 16 October 1991
Deck/Cargo
Issued 21 September 1991 Resolved
MAKE PERMANENT REPAIRS TO PUMPROOM VENTS FLAMESCREENS.
Condition: Unknown
Due 16 October 1991
Resolved 16 October 1991
Deck/Cargo
Issued 21 September 1991 Resolved
CLEAN OR REPLACE THE LIQUID LEVEL SIGHT GLASSES ON THE IGS DECK WATER SEAL AND P/V BREAKER.
Condition: Unknown
Due 22 September 1991
Resolved 23 September 1991
Fire Fighting
Issued 21 September 1991 Resolved
PROVIDE ONBOARD FIXED FIRE SYSTEM FOR PAINT LOCKER BOTH PORT AND STBD DECK HOUSES, OR REMOVE COMBUSTIBLE AND FLAMMABLE LIQUIDS.
Condition: Unknown
Due 16 October 1991
Resolved 16 October 1991
Deck/Cargo
Issued 21 September 1991 Resolved
REMOVE EXCESSIVE OIL FROM PUMPROOM BILGES.
Condition: Unknown
Due 22 September 1991
Resolved 23 September 1991
Unknown
Issued 21 September 1991 Resolved
MAKE PERMANENT REPAIRS TO HYDRAULIC LINE GUARD AFT PORT SIDE PRIOR TO NEXT US PORT CALL.
Condition: Unknown
Due 16 October 1991
Resolved 16 October 1991
Electrical
Issued 21 September 1991 Resolved
MAKE PERMANENT REPAIRS TO EXPLOSION PROOF LIGHTING IN FWD BOSUN STORES PRIOR TO NEXT US PORT CALL.
Condition: Unknown
Due 16 October 1991
Resolved 16 October 1991
Engineering
Issued 21 September 1991 Resolved
MAKE PERMANENT REPAIRS TO STEAMLINE FWD MAIN DECK PRIOR TO NEXT US PORT CALL.
Condition: Unknown
Due 16 October 1991
Resolved 16 October 1991
Engineering
Issued 21 September 1991 Resolved
MAKE PERMANENT REPAIRS TO FLAME SCREENS IN PAINT LOCKER AFT STBD SIDE PRIORTO NEXT US PORT CALL.
Condition: Unknown
Due 16 October 1991
Resolved 16 October 1991
Deck/Cargo
Issued 21 September 1991 Resolved
INSTALL INSULATION BLANKETS ON MOORING WINDLESS PORT AND STBD SIDE PRIOR TONEXT US PORT CALL.
Condition: Unknown
Due 16 October 1991
Resolved 16 October 1991
Fire Fighting
Issued 21 September 1991 Resolved
UPDATE PORTABLE FIRE EXTINGUISHERS MONTHLY INSPECTION PRIOR TO NEXT US PORTCALL.
Condition: Unknown
Due 16 October 1991
Resolved 16 October 1991
Accommodation/Occupational Safety
Issued 21 September 1991 Resolved
REMOVE GEAR ADRIFT FROM BOSUN STORES LADDER PRIOR TO NEXT US PORT CALL.
Condition: Unknown
Due 16 October 1991
Resolved 16 October 1991
Deck/Cargo
Issued 21 September 1991 Resolved
MAKE PERMANENT REPAIRS TO THE FLAME SCREENS ON P/V VALVES.
Condition: Unknown
Due 23 September 1991
Resolved 23 September 1991
Deck/Cargo
Issued 11 May 1984 Resolved
VESSEL CARGO PIPING LEAKS AT GASKET IN #1 CARGO LINE, STBD SIDE OF PUMP ROOM JUST INSIDE THE PUMP ROOM DOOR.
Condition: Unknown
Due 11 May 1984
Resolved 11 May 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.