Records from 1984 to 2018. Most recent: inspection, 17 April 2018.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 47
17 April 2018
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6392917
22 February 2004
Certificate of Compliance · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2013934
2 April 2003
Administrative Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1767009
13 March 2003
Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1757028
27 February 2003
Certificate of Compliance · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1750442
14 September 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 293755
14 August 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 292847
20 May 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 278081
20 May 2000
Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1423381
16 January 1999
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 424681
27 July 1998
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 796645
18 March 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 401602
4 December 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 456424
24 June 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 379812
24 June 1995
Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1377471
27 June 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1171713
23 June 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 367837
23 June 1994
Tank Vessel Examination · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1354780
20 April 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 23604
19 April 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1152236
26 March 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 357115
26 March 1993
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1408945
23 January 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 348620
23 January 1992
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 946542
23 January 1992
Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1261131
7 December 1991
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 447656
15 April 1991
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 343180
26 January 1991
Certificate of Compliance
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1239581
8 September 1990
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 491171
26 January 1990
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 911237
5 January 1990
Certificate of Compliance
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1242442
8 January 1989
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 327830
8 January 1989
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1351494
26 May 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 456251
24 December 1987
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 320388
24 December 1987
Certificate of Compliance
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1007765
9 December 1986
Certificate of Compliance
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1026126
8 December 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 439310
18 January 1986
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 499719
7 January 1986
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 306267
30 October 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 305284
3 January 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 465205
3 January 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1284609
30 November 1984
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 976117
18 September 1984
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 298000
1 August 1984
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 439617
6 June 1984
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 296549
Engineering › Steering Gear System
Issued 27 February 2003
Resolved
The rudder seal is leaking water. LEGACY COMPONENT DESC: Rudder Stock
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2003
Resolved 13 March 2003
Resolution: Received class report from ABS satisfying requirement.
Deck/Cargo › Inert Gas System
Issued 27 February 2003
Resolved
The IGS deck water seal is a semi-dry type. Vessel must submit information to the Coast Guard Marine Safety Center for approval in accordance with 46 CFR 32.53-10, 46 CFR 50.20-5, and 46 CFR 50.10-23 prior to operating in U.S. waters with cargos that are required to be inerted. LEGACY COMPONENT DESC: Water Seal
Action required: 705 - Other - as specified
Due 27 February 2003
Resolved 2 April 2003
Resolution: The Marine Safety Center (MSC) determined that the deck seal was a dry seal and not approved for use in U.S. waters. See narratative, Special Note and MSC letter attached to NEWMS activity #1767009.
Deck/Cargo › Inert Gas System
Issued 27 February 2003
Resolved
The IGS oxygen analyzer has a sensing element that does not work. The vessel must provide a class report attesting to the proper operation of the IGS oxygen analyzer prior to operating in U.S. waters with cargos that are required to be inerted.
Action required: 705 - Other - as specified
Due 27 February 2003
Resolved 13 March 2003
Resolution: Received class report from ABS satisfying requirement.
Deck/Cargo › Inert Gas System
Issued 27 February 2003
Resolved
The vessel must provide a class report attesting to the proper operation of the pressure/vacuum protection for all cargo tanks and the mast riser prior to operating in U.S. waters with cargos that are required to be inerted.
Action required: 705 - Other - as specified
Due 27 February 2003
Resolved 13 March 2003
Resolution: Received class report from ABS satisfying requirement.
Personnel › Manning/Qualifications
Issued 27 February 2003
Resolved
The vessel is not manned in accordance with the Safe Manning Document. The vessel must provide a letter of dispensation from the flag state allowing the vessel to sail without a 2nd Engineer by 01 Mar 2003. LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 705 - Other - as specified
Due 27 February 2003
Resolved 27 February 2003
Resolution: Received letter of dispensation from Ecuador for the 2nd engineer.
Deck/Cargo › Inert Gas System
Issued 27 February 2003
Resolved
The seal on NO.1 IG blower is leaking inert gas. The vessel must provide a class report attesting to the proper repairs of the seal on NO.1 IG blower and the integrity of the IG delivery piping system prior to operating in U.S. waters with cargos that are required to be inerted.
Action required: 705 - Other - as specified
Due 27 February 2003
Resolved 13 March 2003
Resolution: Received class report from ABS satisfying requirement.
Engineering
Issued 14 August 2001
Resolved
Oil water seperator, has a by-pass line between the recirculation line & the overboard discharge line. The 3-way overboard valve has a manual by- pass handle (Marpol Annex I, Reg 16.4): Remove bypasses. Complete repairs &re-survey system to satisfaction of IOPP certificate issuing authority.
Condition: Unknown
Due 14 September 2001
Resolved 14 September 2001
Electrical
Issued 20 May 2000
Resolved
VESSEL EMERGENCY GENERATOR NOT OPERATIVE; UNABLE TO HOLD AN ELECTRICAL CHARGE. NOTED AS PER SOLAS 11 1/26. CLASS REPORT REQUIRED SHOWING THAT GENERATOR WILL AUTO START AND CARRY ELECTRICAL CHARGE.
Condition: Unknown
Due 20 May 2000
Resolved 20 May 2000
Accommodation/Occupational Safety
Issued 20 May 2000
Resolved
VESSEL HAD ROACH INFESTATION IN GALLEY AREA. CORRECT PRIOR TO NEXT U.S. PORT AFTER SAILING FOREIGN.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Navigation
Issued 20 May 2000
Resolved
SPEED LOG NOT OPERATIONAL.
Condition: Unknown
Due 20 May 2000
Resolved 20 May 2000
Construction/Loadline
Issued 20 May 2000
Resolved
OWS NOT OPERATIONAL
Condition: Unknown
Due 20 May 2000
Resolved 20 May 2000
Deck/Cargo
Issued 20 May 2000
Resolved
High level alarm deck siren and light missing.
Condition: Unknown
Due 20 May 2000
Resolved 20 May 2000
Lifesaving
Issued 16 January 1999
Resolved
VESSEL'S LIFEBOAT ENGINES INOPERATIVE DUE TO TYPE OF DIESEL ENGINE AND COLDWEATHER. VESSEL CONDUCTED SATISFACTORY OPERATION OF LIFEBOATS PRIOR TO DEPARTING.
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Navigation
Issued 18 March 1997
Resolved
PROVIDE PROPER WORKING SPEED AND LOG INDICATOR AS REQUIRED BY 33 CFR 164.38, PRIOR TO NEXT DRY DOCK ON FEBRUARY 1998.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Deck/Cargo
Issued 24 June 1995
Resolved
RENEW WASTED CARGO OIL CONTAINMENT UNDER PORT AND STARBOARD CARGO MANIFOLDS.
Condition: Unknown
Due 24 June 1995
Resolved 24 June 1995
Construction/Loadline
Issued 23 June 1994
Resolved
Provide #3S ballast tank for inspection. Ballast tank to be certified safefor entry be a certified Marine Chemist. To be completed prior to cargo operations at next United States Port.
Condition: Unknown
Due 28 June 1994
Resolved 28 June 1994
Deck/Cargo
Issued 23 June 1994
Resolved
Lower oxygen content of cargo tanks be low 8% prior to vessel mooring at facility. SOLAS II-2 Regulation 62._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 June 1994
Resolved 24 June 1994
Fire Fighting
Issued 23 June 1994
Resolved
Hyrdo test all self contained breathing apparatus Bottles.
Condition: Unknown
Due 23 June 1994
Resolved 23 June 1994
Deck/Cargo
Issued 23 June 1994
Resolved
Provide a audible alarm for the loss of control power to the Inert Gas System control panel. Alarm to sound in the cargo control room and Engine control room. SOLAS II-2 Regulation 62 19.1.6.
Condition: Unknown
Due 23 June 1994
Resolved 23 June 1994
Deck/Cargo
Issued 26 March 1993
Resolved
Provide 30 x 30 mesh for all cargo tank ullage flame screens prior to caro operations at next U.S. Port. Cargo tank ullage openings are to be kept closed except when sounding tank.
Condition: Unknown
Due 19 April 1993
Resolved 19 April 1993
Documentation
Issued 26 March 1993
Resolved
Provide copy of vessel response plan as required by NVIC 8-92 to Commnadant(G-MEP-6) U.S. Coast Guard Headquarters, 2100 Second Street, SW, WashingtonD.C. 20593-0001, by 18 August 1993._x001C_ _x001C_
Condition: Unknown
Due 19 April 1993
Resolved 19 April 1993
Construction/Loadline
Issued 26 March 1993
Resolved
Provide ballast tank in mid-body section of vessel for inspection. Ballasttank to be certified safe for entry by a certified Marine chemist. Item tobe completed prior to cargo operations at next U.S. Port.
Condition: Unknown
Due 19 April 1993
Resolved 19 April 1993
Fire Fighting
Issued 5 January 1990
Resolved
PROVIDE ADDITIONAL APPROVED SCBA'S AND SPARE BOTTLES TO COMPLY WITH SOLAS REQUIREMENTS FOR TANKSHIPS TO EQUAL A TOTAL OF FOUR (4), 30 MINUTE UNITS WITH FOUR (4) SPARE CHARGES.
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990
Deck/Cargo
Issued 5 January 1990
Resolved
MAKE PROPER REPAIRS TO AND PROVE PROPER OPERATION OF THE OXYGEN SENSOR AND ASSOCIATED ALARMS AND SHUTDOWNS FOR THE IGS PRIOR TO CARRYING CARGOES REQUIRED TO BE INERTED IN ANY U.S. PORT.
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990
Navigation
Issued 8 January 1989
Resolved
A VIO OF 33 CFR 164.11(R) IN THAT THE ELECTRONIC POSITION FIXING DEVICE REQUIRED BY 33 CFR 164.41(A) WAS NOT MAINTAINED IN AN OPERABLE CONDITION WHILE THE VSL WAS U/W IN THE NAVIGABLE WATERS OF THE U.S.
Condition: Unknown
Due 15 April 1991
Resolved 8 January 1989
Navigation
Issued 8 January 1989
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 8 January 1989
Resolved 8 January 1989
Navigation
Issued 8 January 1989
Resolved
A VIO OF 33 CFR 164.30 IN THAT U.S. CHART #12222, USED BY THE VSL, WAS NOT CORRECTED TO NTM 34/88, WHICH WAS REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSL'S ROUTE FROM VA CAPES TO AMOCO OIL, YORKTOWN, VA. NO FOREIGN EQUIV O/B.
Condition: Unknown
Due 8 January 1989
Resolved 8 January 1989
Navigation
Issued 8 January 1989
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE VSL DID NOT HAVE O/B U.S. CHART #12238 OR ITS FOREIGN EQUIV, WHICH WAS REQUIRED FOR THE VSL'S ROUTE FROM VA CAPES TO AMOCO OIL, YORKTOWN, VA.
Condition: Unknown
Due 24 June 1994
Resolved 24 June 1994
Deck/Cargo
Issued 24 December 1987
Resolved
MAIN DECK IGS DISTRIBUTION LINE, PORT SIDE, HAS FRACTURE AT VERTICAL SUPPORT STANCHION IN VICINITY OF #4 CARGO TANK. FRACTURE AT WELD BETWEEN PIPE AND STANCHION.
Condition: Unknown
Due 24 December 1987
Resolved 24 December 1987
Engineering
Issued 30 October 1985
Resolved
NO MECHANICAL MEANS OF CLOSING DRAIN IN STARBOARD CARGO MANIFOLD CONTAINMENT, A VIOLATION OF 33 CFR 155.310
Condition: Unknown
Due 7 January 1986
Resolved 30 October 1985
Documentation
Issued 30 October 1985
Resolved
CONTENT OF OIL TRANSFER PROCEDURES ARE NOT IN ACCORDANCE WITH 33 CFR 150.750
Condition: Unknown
Due 7 January 1986
Resolved 30 October 1985
Fire Fighting
Issued 30 October 1985
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 7 January 1986
Resolved 30 October 1985
Deck/Cargo
Issued 30 October 1985
Resolved
CARGO TANK ULLAGE OPENINGS LEFT OPEN, WITHOUT FLAME SCREENS, WHILE NOT UNDER IMMEDIATE SUPERVISION OF CREW MEMEBER, AND WHILE VESSEL WAS FULLY LOADED WITH #6 FUEL OIL A VIOLATIO OF 46 CFR 35.30-10.
Condition: Unknown
Due 30 October 1985
Resolved 30 October 1985
Deck/Cargo
Issued 18 September 1984
Resolved
VESSEL NOT LOADED IAW DAMAGE STABILITY BOOK AS REQ BY MARPOL 73/78 REGS
Condition: Unknown
Due 30 November 1984
Resolved 18 September 1984
Deck/Cargo
Issued 6 June 1984
Resolved
VSL NOT LOADED ICW DAMAGE STABILITY BOOK
Condition: Unknown
Due 30 November 1984
Resolved 6 June 1984
Construction/Loadline
Issued 6 June 1984
Resolved
CLOSURE FOR GOOSENECK VENT ON STBD COFFERDAM AT PUMPROOM MISSING
Condition: Unknown
Due 30 November 1984
Resolved 6 June 1984
Navigation
Issued 6 June 1984
Resolved
SAT NAV EQUIP INOP
Condition: Unknown
Due 30 November 1984
Resolved 6 June 1984
Deck/Cargo
Issued 6 June 1984
Resolved
OIL TRANSFER PROCEDURES INCOMPLETE
Condition: Unknown
Due 30 November 1984
Resolved 6 June 1984
Deck/Cargo
Issued 6 June 1984
Resolved
VESSEL DID NOT HAVE INSTRUMENTS FOR MEASURING HYDROCARBON CONTENT IN ATMOS
Condition: Unknown
Due 30 November 1984
Resolved 6 June 1984
Navigation
Issued 6 June 1984
Resolved
PROVIDE CHART OF PENOBSCOTT BAY AND RIVER PRIOR TO DEP FM PTMTH N.H.
Condition: Unknown
Due 30 November 1984
Resolved 6 June 1984