← All vessels
BIG ONE
Freight Ship · Bulk Carrier class · Built 1980s · USCG East District (CGD-E) · Other hulls named BIG ONE
BIG ONE is a 1981 freight ship. The Coast Guard has recorded 40 inspections since 1984, most recently in November 2005, along with 37 deficiencies and 2 operational controls.
Records from 1984 to 2005. Most recent: inspection, 23 November 2005.
- Built
- 1981
- Last inspected
- 23 November 2005
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 37 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7925857 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7HBB
228057
Flag
MARSHALL ISLANDS
—
Maury page id
psix-228057
Inspections, by type
…with no type recorded25
Years with a record
13 calendar years (1984–2005)
The 40 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it29496 - Regulatory (Subpart C or D), Gross Ton
51267 - Dead Weight, Ton
17143 - Regulatory (Subpart C or D), Net Ton
51267 - Dead Weight, Ton
17143 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 40
23 November 2005
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2542939
24 October 2005
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2525293
24 June 2005
ISPS II Exam · PII Safety Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2401422
15 March 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 388999
21 January 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 387122
29 August 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 382045
29 August 1995
Tank Vessel Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 882449
5 June 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 462720
13 April 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 377323
17 December 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 502495
2 August 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1396155
1 August 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 173878
28 July 1994
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1175592
27 July 1994
Deficiency Check · Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1175836
22 July 1994
Tank Vessel Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1444864
2 December 1993
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 488780
22 September 1993
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1154855
10 July 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 359208
10 July 1993
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 842377
20 March 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 349397
14 November 1991
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1243606
1 November 1991
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 942668
27 August 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 675959
20 August 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 677419
3 August 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 345243
8 March 1991
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 504720
15 February 1991
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 499477
15 February 1991
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 905018
21 October 1990
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 339897
21 October 1990
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 921931
21 July 1989
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1209189
20 July 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 331550
17 March 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1029933
15 March 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 321898
8 January 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 320568
8 January 1988
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1011519
8 January 1988
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1011522
21 February 1986
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 455690
14 November 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 305438
14 November 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 298868
Deficiency record · 37
Engineering › Fuel Oil Service System › Hose
Issued 26 June 2005
Resolved
High pressure fuel oil hose (#5 cylinder) on main engine is leaking.
Fire Fighting › Fire Main › Condition
Issued 26 June 2005
Resolved
Mechanical seal on main fire pump is defective.
Electrical
Issued 21 January 1996
Resolved
GLOBES AND OTHER PROTECTIVE COVERS WERE MISSING FROM SEVERAL LIGHT FIXTURES, INCLUDING THE HOSPITAL, AB QTRS, REEFER FLATS, AND PASSAGEWAY._x001C_ SOME FIXTURES IN THE HOSPITAL WERE MISSING BULBS SO THERE WERE OPEN SOCKETS.
Fire Fighting
Issued 29 August 1995
Resolved
Renew fire extinguishers in port & stbd lifeboats, wasted due to corrosion.New extinguishers required prior to departing Jacksonville, FL.
Lifesaving
Issued 29 August 1995
Resolved
Stbd lifeboat propulsion motor inoperative. Prove operation of engine prior to departing Jacksonville.
Deck/Cargo
Issued 29 August 1995
Resolved
Renew cargo heating steam return lines in way of temporary patches located between #2 and #3 cargo tanks and aft at #7 cargo tank at next drydock but not later than 01FEB96.
Electrical
Issued 29 August 1995
Resolved
Light fixtures are not explosionproof in emergency battery locker, radio battery power supply. Provide explosionproof fixtures not later than 29SEP95.
Electrical
Issued 29 August 1995
Resolved
Bulkhead wiring penetrations into emergency battery locker are not explosionproof or vaporproof. Provide and install explosionproof glands not later than 29SEP95.
Fire Fighting
Issued 29 August 1995
Resolved
Gauge broken on starboard aft foam monitor at #1 lifeboat. Renew gauge not later than 29SEP95.
Deck/Cargo
Issued 29 August 1995
Resolved
Foundation bracket fractured on IG alternative supply/discharge line at starboard liferail. Bracket to be repaired at next drydock and not later than 01FEB96.
Engineering
Issued 27 July 1994
Resolved
DETERMINE PROBLEM WITH MAIN PROPULSION AND AUTOMATION SYSTEM CAUSING MAIN ENGINE SHUTDOWN AND MAKE NECESSARY REPAIRS TO SATISFACTION OF CLASS SOCIETY. PROVIDE LOCAL COAST GUARD WITH SATISFACTORY SURVEYOR REPORT PRIORTO DEPARTURE PORT OF HOUSTON, TX.
Engineering
Issued 27 July 1994
Resolved
DETERMINE PROBLEM WITH MAIN PROPULSION AND MAKE NECESSARY REPAIRS TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY CLASS SURVEYOR REPORT TO LOCAL COAST GUARD PRIOR TO DEPARTING PORT OF HOUSTON, TX.
Lifesaving
Issued 22 July 1994
Resolved
RENEW HYDROSTATIC RELEASES ON P/S AFT LIFERAFTS.
Electrical
Issued 22 July 1994
Resolved
PROVE PROPER OPERATION OF P/S EMBARKATION LIGHTS FOR LIFEBOATS.
Fire Fighting
Issued 22 July 1994
Resolved
SERVICE FIXED CO2 FIRE FIGHTING SYSTEM.
Deck/Cargo
Issued 22 July 1994
Resolved
PROVE PROPER OPERATION OF IGS INCLUDING ALARM PANEL AND SHUTDOWNS.
Fire Fighting
Issued 22 July 1994
Resolved
PROVE PROPER OPERATION OF PORT BRIDGE FIRE STATION VIA EMERGENCY FIRE PUMP.
Lifesaving
Issued 22 July 1994
Resolved
SERVICE FORWARD SIX (6) MAN LIFERAFT.
Lifesaving
Issued 22 July 1994
Resolved
RENEW EXHAUST PIPING IN STARBOARD LIFEBOAT.
Unknown
Issued 22 July 1994
Resolved
PROVE PROPER OPERATION OF INCINERATOR.
Lifesaving
Issued 22 July 1994
Resolved
REPAIR DEWATERING PUMP IN STARBOARD LIFEBOAT.
Construction/Loadline
Issued 10 July 1993
Resolved
BALLAST MAY NOT BE DISCHARGED FROM #3 STBD BALLAST TANK IN U.S. WATERS. PRIOR TO RETURNING TO U.S. WATERS, CLEAN #3 STBD BALLAST TANK AND MAKE_x001C_ AVAILABLE FOR EXAMINATION BY COAST GUARD INSPECTOR.
Construction/Loadline
Issued 10 July 1993
Resolved
PRIOR TO RETURN TO U.S. WATERS, CLEAN THE MACHINERY SPACE BILGES TO MINIMIZE OIL IN THE BILGES.
Accommodation/Occupational Safety
Issued 10 July 1993
Resolved
PRIOR TO RETURN TO U.S. WATERS, REPAIR THE SIGHT GLASS ON THE MARINE SANITATION DEVICE LOCATED IN THE MACHINERY SPACE.
Deck/Cargo
Issued 10 July 1993
Resolved
PRIOR TO DEPARTURE BIG STONE ANCHORAGE AREA, ALL CARGO TANK MUST BE INERTED. MASTER OF THE VESSEL MUST MAKE A REQUEST TO USCG TO DEPART ANCHORAGE AREA WHEN ALL CARGO TANKS ARE INERTED TO 8 PERCENT OXYGEN.
Electrical
Issued 10 July 1993
Resolved
PRIOR TO RETURNING TO U.S. WATERS, REMOVE OR MAKE PERMANENT REPAIRS TO ELECTRICAL WIRES LOCATED ON PORTSIDE OF BRIDGE WING.
Electrical
Issued 10 July 1993
Resolved
PRIOR TO RETURNING TO U.S. WATERS, PROVIDE PROTECTIVE GUARD OVER ELECTRICALLIGHT BULB IN EMERGENCY GENERATOR ROOM.
Navigation
Issued 3 August 1991
Resolved
RADAR INOPERABLE
Engineering
Issued 3 August 1991
Resolved
WHEN INSPECTED BY THE BOARDING OFFICER, THE VESSELS OWS WAS INOPERABLE.
Accommodation/Occupational Safety
Issued 3 August 1991
Resolved
WHEN INSPECTED BY THE BOARDING OFFICER, THE VESSELS MSD WAS INOPERABLE.
Accommodation/Occupational Safety
Issued 21 October 1990
Resolved
VESSEL'S MARINE SANITATION DEVICE NOT FUNCTIONING PROPERLY. UNTIL PROVEN_x001C_ TO OPERATE SATISFACTORILY TO ATTENDING USCG MARINE INSPECTOR, THE VESSEL'S_x001C_MSD OVERBOARD DISCHARGE VALUE SHALL REMAIN LOCKED CLOSED WHILE IN U.S. _x001C_ WATERS.
Unknown
Issued 21 October 1990
Resolved
VESSEL DOESNT HAVE INTRINSICALLY SAFE HAND HELD RADIOS ABOARD THE VESSEL _x001C_ SHALL PROVIDE PROOF OF INTRINSICALLY SAFE HAND HELD RADIOS FOR WORK ON THE CARGO DECK. MUST PROVIDE THEM TO SATISFACTION OF USCG MARINE INSPECTOR, _x001C_ PRIOR TO TRANSFERRING ANY GRADE B OR C CARGO IN U.S. WATERS.
Engineering
Issued 21 October 1990
Resolved
VESSEL'S OILY WATER SEPARATOR NOT TESTED WHILE OPERATING UNTIL PROVEN TO _x001C_ OPERATE PROPERLY TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTORTHE VESSEL'S OVERBOARD DISCHARGE VALUE SHALL REMAIN LOCKED CLOSED AND RE-_x001C_ MAIN SO AND RETAINS ITS SLOPS ABOARD WHILE IN U.S. WATERS
Navigation
Issued 8 January 1988
Resolved
BRITISH ADMIRALTY LIGHT LIST, VOL J., 1986 EDITION ON BOARD BUT NOT CORRECTED UP TO DATE.
Documentation
Issued 8 January 1988
Resolved
VESSEL'S CARGO OIL TRANSFER PROCEDURES INADEQUATE.
Documentation
Issued 8 January 1988
Resolved
VESSEL'S FUEL OIL (BUNKER) TRANSFER PROCEDURES INADEQUATE.
Deck/Cargo
Issued 8 January 1988
Resolved
NO PERSONNEL ON BOARD WERE ABLE TO CALIBRATE AND OPERATE IGS. PRIOR TO NEXTU.S. PORT CALL TEST AND LOG RESULTS OF TESTS IN VESSEL LOG.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.