Records from 2016 to 2025. Most recent: inspection, 2 December 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the tow units and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 47
2 December 2025
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8276013
7 October 2025
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8244867
3 April 2024
PSC A
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7885694
9 February 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7863316
26 December 2023
PSC A
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7841712
11 December 2023
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7837625
26 October 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7814707
27 May 2023
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7697071
24 March 2023
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7656411
13 March 2023
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7650123
11 January 2023
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7620721
25 October 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7583407
22 October 2022
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7582392
30 September 2022
PSC A
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7569095
28 July 2022
In-Service Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7518333
28 July 2022
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7519676
26 May 2022
In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7459497
25 May 2022
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7499423
26 February 2022
PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7401588
9 February 2022
Deficiency Check · Administrative Inspection · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7389737
17 May 2021
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7199515
4 May 2021
PSC A
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7188751
21 April 2021
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7179866
25 January 2021
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7130115
24 January 2021
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7129714
12 January 2021
PSC A · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7123100
15 December 2020
PSC B · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7111973
6 December 2020
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7138599
4 June 2020
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6987633
11 March 2020
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6924756
28 February 2020
MARPOL Annex I Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6917932
29 November 2019
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6864609
5 July 2019
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6736808
21 April 2019
ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6664525
18 April 2019
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6665215
25 January 2019
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6613604
27 December 2018
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6603039
26 December 2018
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6602847
6 September 2018
ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6533737
9 October 2017
ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6281997
15 June 2017
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6176378
17 March 2017
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6106460
11 February 2017
ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6083337
4 November 2016
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6035464
3 October 2016
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6015198
30 September 2016
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6013422
4 February 2016
ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5806722
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 July 2022
Resolved
13101-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship or persons on board. Vessel suffered loss of propulsion while departing from the CNX terminal in the port of Baltimore.
74 SOLAS (20) I/11(a) 60ac
Action required: 60 - Rectify deficiencies prior to movement
Due 28 July 2022
Resolved 28 July 2022
Resolution: Recieved Class Report rectifying the deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 May 2022
Resolved
13101 - Propulsion Main Engine - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel experienced a loss of astern propulsion during mooring operations in Tampa Bay, Fl.
74 SOLAS (20) I/11.a
17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2022
Resolution: Received class report stating main engine issue is resolved.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 9 February 2022
Resolved
15108 - The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. PSCO’s observed unapproved modifications to watertight door alarm sensors and the pumps and piping arrangements on the heavy fuel oil purifier system. The non-conformities and modifications were not reported to either class or Flag. Due to the objective evidence in the below deficiencies, the vessel is not in substantial compliance with relevant conventions, calling into question the adequacy and implementation of the vessel’s SMS under the ISM code. An external audit conducted by the Flag or RO is required within 30 days to determine whether the ship is operating in accordance with the ISM Code. Provide a copy of the completed audit report to USCG prior to departure from port.
74 SOLAS (20) IX/3.1
ISM Code 10.1
30 B / C
Action required: 30 - Ship detained
Resolved 19 February 2022
Resolution: LR conducted third party audit. Multiple non-conformities found.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 9 February 2022
Resolved
02101 - All watertight doors shall be kept closed during navigation except when necessarily opened for the working of the ship, and shall always be ready to be immediately closed. During the cargo tunnel examination, the PSCO observed 9 out the 9 water tight doors did not close properly. 4 watertight doors on the port side failed to close properly, 4 watertight doors on the starboard side failed to close. The watertight door leading from the engine room to the tunnel also failed to close properly. The failures were caused by leaking hydraulic lines, frozen wheels, and modification to the sensor detection closed position.
74 SOLAS II-I/13(n)
30 A / C
Action required: 30 - Ship detained
Resolved 19 February 2022
Resolution: USCG, MH FLAG and LR tested all WTD. all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 February 2022
Resolved
13108 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed the #1 SSDG was leaking from the shaft causing the leaking oil to heat up and smoke in the shaft area creating an extreme fire hazard.
74 SOLAS (20) I/11.a
30 A / C
Action required: 30 - Ship detained
Resolved 19 February 2022
Resolution: Shaft seal was repaired, no more leaks. LR confirmed repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 February 2022
Resolved
13108 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed a modified heavy fuel oil purifier utilizing a pneumatic pump not designed for the system.
74 SOLAS (20) I/ 11.a
17 A / C
Action required: 30 - Ship detained
Resolved 19 February 2022
Resolution: Received letter from ALFA LAVAL stating third party pump can be used. Crew secured pump to purifier frame. LR confirmed repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 4 May 2021
Resolved
03103 - The company should identify equipment and technical systems the sudden operational failure of which may result in hazardous situations. The safety management system should provide for specific measures aimed at promoting the reliability of such systems. PSCO observed gangway rigged at an angle that does not comply with shipboard SMS procedures and the gangway technical requirements. Also, the vessel's SMS states the gangway should be suitably rigged to compensate for the movement of the ship, however it was rigged in such a way preventing the rollers at the bottom from coming into contact with the pier rendering it ineffective and creating high stress areas on the gangway.
74 SOLAS (14)IX/3.1
ISM Code 10.3
40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 May 2021
Resolution: Recieved class report verifying rectified deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 4 May 2021
Resolved
03103 - Satisfactory means of safe passage in the form of guardrails, gangways, etc. shall be provided for the protection of the crew in getting to any space used in the essential operation of the ship. The exit route toward the starboard side lifeboat had an open area near the lifeboat that had no courses preventing a person from falling to the deck below.
ILLC 25(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 May 2021
Resolution: Recieved class report.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 4 May 2021
Resolved
09201 - Lockers or housing must be vented to the open air near the top and bottom for circulation of vapors. PSCO observed secured ventilation at acetylene storage locations.
46 CFR 147.60
10c
Action required: 10 - Deficiency Rectified
Resolved 4 May 2021
Resolution: Corrected on the spot.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 4 May 2021
Resolved
01315 - The Oil Record Book Part 1 shall be completed on each occasion whenever discharge overboard or disposal otherwise of bilge water which has accumulated in machinery spaces. PSCO observed two receipts of bilge water transfer to reception facility, both of which, were note entered into the Oil Record Book Part 1.
MARPOL (2017) Annex I/17.2.4
10c
Action required: 10 - Deficiency Rectified
Resolved 4 May 2021
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 January 2021
Resolved
07126-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed fuel leaks in #1 and #2 MDG's. MDG #1 cylinder #3 was leaking at the pump and fuel lines and #2 MDG Cylinder #3 and #5 fuel pumps were leaking. 74 Solas 14 I/II (a)
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2021
Resolved 12 January 2021
Resolution: Received class surveyor's report
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 12 January 2021
Resolved
07122- Plans and booklets shall be kept up to date; any alterations there to shall be recorded. Fire control plan onboard the vessel conflicted with the ships structure. In addition the symbols do not match the provided key in the firecontrol plan. 74 SOLAS II-2/4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2021
Resolved 21 April 2021
Resolution: Classification Society provided documentation to attest to approval of fire control plans on board in accordance with vessel's arrangement.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 December 2020
Resolved
74 SOLAS (14) I/11(a):
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed fuel oil covering the aft starboard side of the main engine; the aft portion of the main engine including 3 pipelines into the engine; dripping from the second deck of the main engine; leaking from gaskets on the main engine; pooled in an unapproved container below a gasket; and pooled under fuel oil purifier.
Action required: 30 - Ship detained
Resolved 16 December 2020
Resolution: Received class report (see attached)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 December 2020
Resolved
74 SOLAS (14)II-2/14.2.2.1:
Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. Multiple fire hose nozzles were packed with granular material and connection points were severely corroded.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2020
Resolution: Received class report (see attached)
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 15 December 2020
Resolved
74 SOLAS (14) IX/3.1 & ISM Code A 10.1:
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. PSCO’s requested maintenance checklist for the engine room and firefighting equipment. Ship’s crew provided completed “Algoma central corporation pre-inspection checklist” where the engine department had checked “yes” for engine room machinery clean and free of oil. They had also marked “yes” for steering gear save-all clean and free of oil, overall cleanliness of engine room acceptable, and no leaks in the purifier room. Completed “Algoma Ship Tech LTD Firehoses/Hydrants/Nozzles and attachments” maintenance logs were also notated as “Checked All SAT” weekly, over the last two months. Due to the objective evidence in the above deficiencies, the vessel is not in substantial compliance with relevant conventions. The Captain of the Port questions the adequacy and overall implementation of the vessel’s SMS under the ISM Code. An external audit conducted by the flag or RO is required to determine whether the ship is operating in accordance with the ISM Code. Provide a copy of the completed audit report to the USCG prior to departure from port.
Action required: 30 - Ship detained
Resolved 17 December 2020
Resolution: Received ISM Audit (see attached)
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 December 2020
Resolved
74 SOLAS (14) II-2/14.2.1.1.2:
The fire detection and fire alarm systems shall be kept in good order so as to ensure their required performance if a fire occurs. The smoke detector in the “Take Up Hydraulic Station” was damaged.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2020
Resolution: Received class report (see attached)
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 15 December 2020
Resolved
74 SOLAS (14) II-2/15.2.4.1:
Plans and booklets shall be kept up to date; any alterations there to shall be recorded. Fire Control Plans (FCP) on board the vessel conflicted with the ship’s structure. Additionally, the fire control plans on board did not match each other, observed discrepancies within galley pantry between the corridor FCP and the FCP provided by the Master.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2020
Resolution: Received class report (see attached)
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 December 2020
Resolved
74 SOLAS (UnAmend) II-2/23(f):
Fire doors in main vertical zone bulkheads and stairway enclosures shall be of the self-closing type. Emergency escape fire door in bottom deck engine room failed to latch properly when closed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2020
Resolution: Received class report (see attached)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 December 2020
Resolved
74 SOLAS (UnAmend) II-1/27(a)(v):
Lighting fittings shall be arranged to prevent temperature rises to the wiring and prevent surrounding material from becoming excessively hot. Numerous light covers in the engine room had cracks and holes in them.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2020
Resolution: Received class report (see attached)
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 15 December 2020
Resolved
ICLL (66) Article 15:
After any survey of the ship under article 14 has been completed, no change shall be made in the structure, equipment, arrangements, material or scantlings covered by the survey, without the sanction of the administration. PSCO observed sunlight penetrating the forecastle door seal rendering the watertight integrity compromised.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2020
Resolution: Received class report (see attached)
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 15 December 2020
Resolved
ICLL (66) 12(1):
All access openings in bulkheads at ends of enclosed superstructures shall be fitted so that the structure is weathertight when closed. The means for securing these doors shall be so arranged that they can be operated from both sides of the bulkhead. The weathertight door from the galley to the weather deck was missing the handle creating an opening in the door, making the condition non-weathertight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2020
Resolution: Received class report (see attached)
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 December 2020
Resolved
74 SOLAS (14) III/34 & LSA Code 1.2.2.7:
Life-saving appliances shall be fitted with retro-reflective material where it will assist with detection. The retro-reflective tape on the port side lifeboat is deteriorated.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2020
Resolution: Received class report (see attached)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 December 2020
Resolved
74 SOLAS (UnAmend) II-1/27(a)(ii):
The fronts of the switchboards shall be suitably guarded. There was an opening in the front of the switchboard in the engine control room where a breaker was removed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2020
Resolution: Received class report (see attached)
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 15 December 2020
Resolved
74 SOLAS (14) I/11(a):
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed hydraulic oil actively leaking from pumps on hatch covers: 3 port, 4 port, 5 starboard, 6 port, 6 starboard, and 7 port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2020
Resolution: Received class report (see attached)
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 15 December 2020
Resolved
74 SOLAS (14) I/11(a):
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed a hose used for draining hydraulic oil from the hydraulic oil tank that was leaking on the steering gear pump, then into the small discharge containment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2020
Resolution: Received class report (see attached)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 December 2020
Resolved
74 SOLAS (14) I/11(a):
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed condensation leaking from the pipelines to the refrigerated stores. The condensation was pooled on the deck and unable to drain due to a plugged drain.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 December 2020
Resolution: Received class report (see attached)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 December 2020
Resolved
49 CFR 176.200(c):
When cylinders of Class 2 (compressed gas) materials being transported by vessel, the cylinders must be dunnaged 10 cm off any metal deck. PSCO observed oxygen and acetylene tanks stored directly on metal deck of the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 January 2021
Resolution: PSCO verified that the oxigen and acetylene cyloinders were properly secured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 December 2020
Resolved
33 CFR 151.2050(f):
The master, owner, operator, agent or person in charge of any vessel equipped with ballast water tanks that operates in waters of the United States must remove fouling organisms from the vessel’s hull. PSCO observed an excessive amount of algae growing on the vessel’s hull.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 January 2021
Resolution: Vessel's hul was cleaned at the last foreing port prior to the vessel's return to the US.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 15 December 2020
Resolved
74 SOLAS (04) III/13.1.3:
Each survival craft shall be stowed in a state of continuous readiness so that two crew members can carry out preparations for embarkation and launching in less than 5 minutes. During operational test, it took crew members approximately 13 minutes to start the rescue boat engine.
Suitable arrangements shall be mad
Action required: 10 - Deficiency Rectified
Resolved 16 December 2020
Resolution: Deficiency rectified to the satisfaction of the attending Coast Guard Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 15 December 2020
Resolved
74 SOLAS (UnAmend) III/19:
Suitable arrangements shall be made for embarkation into the lifeboats. The shackles to the guard rail chain at the port side life boat embarkation area were seized, causing an obstruction to embarking the port side lifeboat.
Action required: 10 - Deficiency Rectified
Resolved 16 December 2020
Resolution: Deficiency rectified to the satisfaction of the attending Coast Guard Inspector.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 28 February 2020
Resolved
MARPOL I/15.1
Discharge into the sea of oil from ships shall be prohibited. While conducting bunker operations, vessel's sounding tube on Portside LSFO tank was giving false readings due to Heavy Fuel Oil build up in sounding tube. These readings were well below the actual levels in the tank, thus causing fuel oil to overfill the tank, discharge from the air vent, fill up the small containment and discharge approximately 15-20 liters into a U.S. navigable waterway.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2020
Resolved 1 March 2020
Resolution: Recieved report from classification society attesting to repairs