Records from 1985 to 2004. Most recent: inspection, 7 July 2004.
Inspection history · 67
7 July 2004
PII Safety Exam
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2124862
21 May 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2074259
17 May 2004
Certificate of Compliance · MTSA/ISPS Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2070179
16 May 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2069088
2 July 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 392759
28 May 1996
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 517386
29 March 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 461069
4 October 1995
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 469757
3 September 1995
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 85594
3 September 1995
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 382613
12 August 1995
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 484891
20 June 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1190242
13 June 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 379382
13 June 1995
Tank Vessel Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 883963
10 March 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 376071
20 January 1995
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 647066
12 December 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 505998
20 June 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 439921
16 June 1994
Tank Vessel Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1329563
9 April 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 533025
5 October 1993
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 512879
29 September 1993
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 647063
15 June 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 358941
15 June 1993
Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1151491
25 April 1993
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 358029
28 March 1993
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 462818
28 March 1993
Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1142148
19 February 1993
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 146723
19 February 1993
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 212944
14 December 1992
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 355073
13 October 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 512575
23 June 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 937556
14 April 1992
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 502591
13 April 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1258578
27 March 1992
Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 952552
2 December 1991
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 347460
2 December 1991
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1250073
28 October 1991
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 647062
28 October 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 939103
26 October 1991
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 346623
20 September 1991
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 451188
22 March 1991
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 342716
22 March 1991
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 912577
22 November 1990
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 532300
20 March 1990
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 335942
20 March 1990
Certificate of Compliance
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1243320
8 March 1990
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 537793
7 February 1990
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 335206
12 September 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 332566
1 September 1989
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 440668
9 April 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1199827
25 March 1989
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 329296
25 March 1989
Certificate of Compliance
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1349822
17 October 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 501874
28 February 1988
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 522346
28 February 1988
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1334776
28 February 1988
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1337297
28 September 1987
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 488179
23 February 1987
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 514874
21 February 1987
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 314415
24 November 1986
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 519895
3 May 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 473142
20 February 1986
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 307213
20 February 1986
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 990923
13 September 1985
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 467000
28 January 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1287114
27 January 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 300011
Operations/Management › Vessel Safety Management
Issued 17 May 2004
Resolved
Based on the findings of the overloaded cargo conditions, the inop emergency fire pump, holed firemain piping system, the validity of the Safety Management System is questionable. Perform an external third party SMS audit in the presence of a USCG Marine Inspector. LEGACY COMPONENT DESC: External Certification/Verification/Control
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2004
Fire Fighting › Emergency Fire Pumps
Issued 17 May 2004
Resolved
Emergency fire pump is inop. Repair to the satisfaction of the flag state rep. LEGACY COMPONENT DESC: Pressure
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2004
Fire Fighting › Fire Main
Issued 17 May 2004
Resolved
Fire Main piping is leaking iwo fire station no. 33. Make permanent and proper repairs to the fire main piping to the satisfaction of the flag state rep. LEGACY COMPONENT DESC: Pressure
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2004
Engineering › Steering Gear System › Solenoid Valve
Issued 17 May 2004
Resolved
Leaks on steering system directional valve. Repair leaks to the satisfaction of the flag state rep. LEGACY COMPONENT DESC: Valve, Control
Condition: Improper/Lack of Maintenance
Due 1 July 2004
Resolved 29 June 2004
Electrical › Electric Generation Source (service) › Generator
Issued 17 May 2004
Resolved
Oil is leaking from the no. 2 generator. Repair leaks to the satisfaction of the flag state rep. LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Due 1 July 2004
Resolved 29 June 2004
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 17 May 2004
Resolved
Lagging to Main Engine Exhaust is falling off. Repair lagging and prove no exhaust leaks to the satisfaction of the flag state rep.
Condition: Improper/Lack of Maintenance
Due 17 June 2004
Resolved 29 June 2004
Stability › Weathertight Integrity › General
Issued 17 May 2004
Resolved
Weathertight doors on port and stbd boat decks are not weathertight. Adjust doors to the satisfaction of the flag state rep.
Condition: Improper/Lack of Maintenance
Due 1 July 2004
Resolved 29 June 2004
Lifesaving › Lifeboat › Hull
Issued 17 May 2004
Resolved
Retro-reflective tape on bottom of lifeboats is missing. Replace.
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Resolved 29 June 2004
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 17 May 2004
Resolved
Fire control plan does not reflect actual location of international shore connection. Correct Fire Control Plan.
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Resolved 29 June 2004
Deck/Cargo › Inert Gas System
Issued 17 May 2004
Resolved
Cargo tanks are not properly inerted. Correct situation prior to vesssel's entry into port. Failure of master to ensure the inert gas system is operated as necessary to maintain an inert atmosphere in the cargo tanks.
Condition: Placed in Improper Service
Due 17 May 2004
Resolved 17 May 2004
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 17 May 2004
Resolved
Vessel's cargo tanks have a overfill/high-high alarm. Correct prior to port entry.
Condition: Placed in Improper Service
Due 17 May 2004
Resolved 17 May 2004
Operations/Management › Port and Waterways Safety
Issued 17 May 2004
Resolved
Failure to notify the nearest USCG MSO or Group office of a hazardous condition either aboard a vessel or caused by a vessel or its operation. LEGACY COMPONENT DESC: Notice of Hazardous Condition
Action required: 705 - Other - as specified
Resolved 20 May 2004
Operations/Management › Cargo Transfer/Lightering
Issued 17 May 2004
Resolved
Maximum cargo level of oil. 33 CFR 155.775 LEGACY COMPONENT DESC: Conducted IAW Vessel Transfer Procedures
Action required: 705 - Other - as specified
Resolved 18 May 2004
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 17 May 2004
Resolved
Make permanent and proper repairs to the no. 2 port cargo tank IG line which currently has an epoxy soft patch.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 29 June 2004
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 17 May 2004
Resolved
Make permanent and proper repairs to the no. 1 port cargo tank IG line which is currently leaking iwo flange for the blank.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 29 June 2004
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 17 May 2004
Resolved
Make permanent and proper repairs to no. 2 center cargo tank IG line found wasted and holed.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 29 June 2004
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 17 May 2004
Resolved
Make permanent and proper repairs to no. 4 center cargo tank IG line which currently has an epoxy soft patch.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 29 June 2004
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 17 May 2004
Resolved
Make permanent and proper repairs to dresser coupling aft of mast riser on IG Main.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 29 June 2004
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 17 May 2004
Resolved
Make permanent and proper repairs to deck seal foundation which is heavily corroded by deck seal bottom and main deck under deck seal is also corroded. LEGACY COMPONENT DESC: Water Seal
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 29 June 2004
Engineering › Bilge Water Management System › Piping
Issued 17 May 2004
Resolved
Renew band clamp on direct bilge suction G outlet of eductor in Engine Room. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 1 July 2004
Resolved 29 June 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 17 May 2004
Resolved
Repair/replace clamp patch found on sea water outlet on Main Condenser. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 1 July 2004
Resolved 29 June 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 17 May 2004
Resolved
Make permanent and proper repairs to the cooling water inlet to the auxiliary cooler which is currently leaking. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 1 July 2004
Resolved 29 June 2004
Documentation
Issued 3 September 1995
Resolved
PROVIDE A LETTER OF UNDERTAKING FOR THE AMOUNT OF $25,000 FOR VIOLATION OF 33USC 1321(b)(3) PRIOR TO DEPARTING FROM THE PORT OF PORTLAND.
Condition: Unknown
Due 3 September 1995
Resolved 11 September 1995
Deck/Cargo
Issued 3 September 1995
Resolved
THE VESSEL MUST KEEP CARGO TANKS 1S AND 2S IN AN INERTED CONDITION WHILE INU.S. WATERS UNTIL PERMANENT REPAIRS TO THE HULL STRUCTURE HAVE BEEN ACCEPTED BY CLASS SOCIETY.
Condition: Unknown
Due 3 September 1995
Resolved 11 September 1995
Construction/Loadline
Issued 3 September 1995
Resolved
PROVIDE DOCUMENTATION FROM CLASS SOCIETY ADRESSING VESSEL'S SEAWORTHINESS TO PROCESS OUT OF PORT FOR REPAIRS TO CORRECT HULL PLATE DAMAGE.
Condition: Unknown
Due 3 September 1995
Resolved 11 September 1995
Construction/Loadline
Issued 3 September 1995
Resolved
PROVIDE DOCUMENTATION FROM CLASS ADDRESSING PERMANENT REPAIRS TO DAMAGED SIDE PLATE AT 1S AND 2S SIDESHELL AREA PRIOR TO ENTRY NEXT US PORT.
Condition: Unknown
Due 4 September 1995
Resolved 11 September 1995
Navigation
Issued 16 June 1994
Resolved
MAKE PERMANENT REPAIRS TO NO.1 STEERING GEAR HYDRAULIC PUMP/MOTOR ASSEMBLY SEAL SO AS TO PREVENT FURTHER EXCESSIVE LEAKAGE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 July 1994
Resolved 20 June 1994
Deck/Cargo
Issued 28 March 1993
Resolved
PRIOR TO RETURN NEXT U.S. PORT MAKE PERMANENT REPAIRS TO PUMPROOM CARGO SUCTION LINES.
Condition: Unknown
Due 28 March 1993
Resolved 28 March 1993
Deck/Cargo
Issued 28 March 1993
Resolved
PRIOR TO TRANSFERRING CARGO NEXT U.S. PORT REPAIR AND PROVE PROPER OPERATION OF NUMBER 2 AND 4 CARGO PUMPS.
Condition: Unknown
Due 28 March 1993
Resolved 28 March 1993
Fire Fighting
Issued 28 March 1993
Resolved
PRIOR TO RETURN NEXT U.S. PORT MAKE PERMANENT REPAIRS TO MAIN DECK FIRE MAIN PIPING.
Condition: Unknown
Due 28 March 1993
Resolved 28 March 1993
Fire Fighting
Issued 27 March 1992
Resolved
RE-EQUIP/INSTALL FIRE STATION NUMBER 35 LOCATED IN AFTER STEERING FLAT PRIOR TO RETURN TO NEXT U.S. PORT.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Deck/Cargo
Issued 27 March 1992
Resolved
REMOVE SOFT PACTHES AND MAKE PERMANENT REPAIRS TO 4 CARGO PUMP DISCHARGE _x001C_ LINES ON THE DISCHARGE SIDE OF THE ISOLATION VALVES PRIOR TO RETURN TO NEXTU.S. PORT.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Deck/Cargo
Issued 27 March 1992
Resolved
MAKE REPAIRS TO NUMEROUS MISSING/BROKEN CARGO PIPE HANGERS LOCATED THROUGH_x001C_OUT THE MAIN DECK AREA.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Engineering
Issued 27 March 1992
Resolved
MAKE PERMANENT REPAIRS TO FUEL OIL LINES FEEDING EMERGENCY FIRE PUMP AND _x001C_ BOW THRUSTER, LOCATED IN EMERGENCY FIRE PUMP ROOM PRIOR TO RETURN TO NEXT U.S. PORT.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Deck/Cargo
Issued 27 March 1992
Resolved
MAKE GASTIGHT BLANK FLANGE FOR SHAFT PENETRATION BETWEEN PUMP ROOM AND ENGINE ROOM IN WAY OF NUMBER 3 CARGO PUMP. REPAIR NUMBER 3 CARGO PUMP PRIORTO RETURN TO NEXT U.S. PORT.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Deck/Cargo
Issued 27 March 1992
Resolved
CARGO PUMP DISCHARGE SIDE PRESSURE NOT TO EXCEED 75 PSI UNTIL PERMANENT REPAIRS ARE MADE TO CARGO DISCHARGE PIPING.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Electrical
Issued 27 March 1992
Resolved
MAKE PERMANENT REPAIR TO DAMAGED CABLE TRAY LOCATED ON MAIN DECK, CENTERLINE, BETWEEN NUMBER 1 AND NUMBER 3 CARGO TANKS PRIOR TO RETURN TO NEXT U.S. PORT.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Electrical
Issued 27 March 1992
Resolved
MAKE PERMANENT REPAIR TO DAMAGED CONDUIT CABLE SECTION IN WAY OF NUMBER 5 STBD CARGO TANK ON MAIN DECK PRIOR TO RETURN TO NEXT U.S. PORT.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Deck/Cargo
Issued 27 March 1992
Resolved
MAKE PERMANENT REPAIR TO BOW THRUSTER PRIME MOVER COOLING LINE LOCATED IN THE EMERGENCY FIRE PUMP ROOM.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Deck/Cargo
Issued 26 October 1991
Resolved
REPAIR AND PROVE PROPER OPERATION OF THE INERT GAS SYSTEM, (ALL ALARMS, SHUTDOWNS & RECORDING DEVICES) PRIOR TO THE RETURN TO U.S. WATERS. CHIEF ENGINEER STATED THAT THE INERT GAS SYSTEM WAS NOT EQUIPPED WITH LOST OF COOLING WATER SHUTDOWN (SCRUBBER).
Condition: Unknown
Due 2 December 1991
Resolved 2 December 1991
Deck/Cargo
Issued 26 October 1991
Resolved
INSTALL FLAME SCREENS (30X30 MESH) IN ALL CARGO TANK P/V VALVES PRIOR TO DEPARTING PORT.
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Deck/Cargo
Issued 26 October 1991
Resolved
PROVE PROPER OPERATION OF THE OIL DISCHARGE MONITOR AND CONTROL SYSTEM AS OUTLINED IN THE INSTRUCTION MANUAL PRIOR TO DEPARTURE FROM PORT.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Deck/Cargo
Issued 26 October 1991
Resolved
THE HYDROSTATIC TEST OF CARGO PIPING TO 1.5 TIMES THE CARGO PUMP RELIEF SETTING WAS NOT CONDUCTED AS REQUIRED BY 33 CFR 156.170 AND THE REQUIREMENTISSUED BY THE COAST GUARD ON 22MAR91 TO HYDROSTATICALLY TEST THE PIPING PRIOR TO THE RETURN TO U.S. WATERS.
Condition: Unknown
Due 2 December 1991
Resolved 2 December 1991
Deck/Cargo
Issued 26 October 1991
Resolved
PROVIDE A CARGO AND BALLAST SYSTEM INFORMATION MANUAL AS REQUIRED BY _x001C_ 33 CFR 157.23 PRIOR TO THE RETURN TO U.S. WATERS.
Condition: Unknown
Due 2 December 1991
Resolved 2 December 1991
Deck/Cargo
Issued 22 March 1991
Resolved
PROVIDE APPROVED PROOF OF HYDROSTATIC OR LIQUID PRESSURE TESTING (OR ALL CARGO PIPING TO 1.5 X MAWP OR 425 PSI.) TO BE COMPLETED PRIOR TO VESSELS RE-ENTRY TO U.S. WATERS.
Condition: Unknown
Due 22 March 1991
Resolved 22 March 1991
Deck/Cargo
Issued 22 March 1991
Resolved
PROVE PROPER OPERATION OF INERT GAS SYSTEM WITH ALARMS AND SHUTDOWNS AS REQUIRED. TO BE COMPLETED TO SATISFACTION OF ATTENDING USCG MARINE INSPECTOR PRIOR TO VESSEL CARRYING ANY REQUIRED INERTING CARGO.
Condition: Unknown
Due 22 March 1991
Resolved 22 March 1991
Deck/Cargo
Issued 12 September 1989
Resolved
33 CFR 155.310(A)(3) THE VESSEL HAD INSUFFICIENT MECHANICAL MEANS OF CLOSING EACH DRAIN AND SCUPPER IN THE CONTAINMENT.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Deck/Cargo
Issued 12 September 1989
Resolved
46 35.30-10 THE ULLAGE HOLES ON CARGO TANKS WHICH WAS NOT GAS FREE WAS LEFT OPEN UNSUPERVISED WITHOUT A PROPER FLAME SCREEN IN PLACE.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Deck/Cargo
Issued 25 March 1989
Resolved
PROVIDE PROPER OPERATION OF THE INERT GAS SYSTEM PRIOR TO CARRYING A CARGO OF CRUDE OIL BUT NO LATER THAN 25JUN89
Condition: Unknown
Due 25 March 1989
Resolved 25 March 1989
Fire Fighting
Issued 27 January 1985
Resolved
TEST FIRE FIGHTING FOAM AND PROVIDE TEST RESULTS FOR SPECIFIC GRAVITY. SAMPLE FROM BOTH FOAM TANKS AS REQUIRED BY 46 CFR 31.10-18(D)
Condition: Unknown
Due 13 September 1985
Resolved 27 January 1985