Records from 1984 to 2007. Most recent: inspection, 16 January 2007.
Inspection history · 34
16 January 2007
ISPS II Exam · COC-TVE Renew · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2856596
10 January 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2853484
19 March 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2605436
3 August 2005
COC-TVE Renew · ISPS II Exam · Ballast Water Examination · Deficiency Check · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2443310
3 July 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2440978
11 January 2000
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 436177
11 January 2000
Tank Vessel Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 814519
6 October 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 179618
13 June 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 53064
22 January 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 424944
22 January 1999
Tank Vessel Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 789020
11 August 1998
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 417436
29 January 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 412271
29 January 1998
Tank Vessel Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 784926
10 October 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 41233
28 January 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 399739
28 January 1997
Tank Vessel Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1101570
25 August 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 394700
13 February 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 387756
13 February 1996
MARPOL Annex V Examination · Tank Vessel Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 878366
20 June 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1390078
10 February 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 375854
10 February 1995
Tank Vessel Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1152393
29 December 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 373838
28 December 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 166871
6 April 1994
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1469424
14 February 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1163995
4 February 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 364393
4 February 1994
Tank Vessel Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1163888
1 March 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 356580
1 March 1993
Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1142799
8 July 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 302895
17 May 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 452960
11 August 1984
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 297493
Fire Fighting › Fixed Deck Foam System › Piping
Issued 16 January 2007
Resolved
Leak at the main fire fighting supply line at the isolation valve for the first cannon. Fix to the satisfaction of Class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 January 2007
Resolution: Received class report from ABS attesting to satisfactory repair. Isolation valve replaced with one that fits properly. Satisfactory test witnessed by Class Surveyor.
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 16 January 2007
Resolved
Starboard Side forward mooring wench steam line is wasted. Fix to the satisfaction of Class
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 January 2007
Resolution: New section of steam line was fabricated ashore, tested, and installed. System piping was brought up to pressure and found satisfactory. Test was witnessed by Class Surveyor.
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 16 January 2007
Resolved
Port side forward steam line has a crack in the weld. Fix to the satisfaction of Class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 January 2007
Resolution: New section of steam line was fabricated ashore, tested, and installed. Once installed, the steam piping was brought up to pressure and found satisfactory. Test witnessed by Class Surveyor.
Construction/Loadline › Hull › Weld
Issued 16 January 2007
Resolved
Port side haus pipe has a crack on the weld. The weld is approximately 5.5 meters above the waterline, however in heavy seas water penetrates the hull through the crack. Fix to the satisfaction of Class.
Action required: 15 - Rectify deficiencies by next port
Resolved 22 January 2007
Resolution: Access hole was cut in the non-tight bulkhead in the forepeak tank to allow further examination. Class certified welders ARC gauged to sound metal. The crack was welded together from both sides. Access hole was inserted and welded. Class Surveyor attests
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 3 August 2005
Resolved
OWS discharge return piping has a small ruptured portion which is leaking. Piping must be replaced.
MARPOL 73/78 ANNEX I Regulation 16 (3)(a)(i)
Action required: 15 - Rectify deficiencies by next port
Due 3 August 2005
Resolved 4 August 2005
Resolution: Coast Guard Inspectors attended the vessel on 04AUG05, and verified that the deficiency was rectified satisfactorily.
Engineering › Steam System (auxiliary) › Piping
Issued 3 August 2005
Resolved
Repair steam leaks on supply line in the lower pump room and aft capstan controls.
SOLAS 74/78 (Amended 2001) Ch II-1 Regulation 33.1
Action required: 705 - Other - as specified
Due 3 September 2005
Resolved 4 August 2005
Resolution: Coast Guard Inspectors attended the vessel on 04AUG05, and verified that the deficiency was rectified satisfactorily.
Engineering › Steam System (auxiliary) › Valve
Issued 3 August 2005
Resolved
Adjust/repack the steam system in the lower pump room.
SOLAS 74/78 (Amended 2001) Ch II-1 Regulation 33.1
Action required: 705 - Other - as specified
Due 3 September 2005
Resolved 4 August 2005
Resolution: Coast Guard Inspectors attended the vessel on 04AUG05, and verified that the deficiency was rectified satisfactorily.
Deck/Cargo › Inert Gas System › IGS Blower
Issued 3 August 2005
Resolved
Provide suitable means to zero and span calibration of IGS prior to carrying p[petroleum products within US Ports.
SOLAS 74/78 (Amended 2001) Ch II-2 Regulation 62.18
Action required: 705 - Other - as specified
Resolved 4 August 2005
Resolution: Coast Guard Inspectors attended the vessel on 04AUG05, and verified that the deficiency was rectified satisfactorily.
Deck/Cargo
Issued 14 February 1994
Resolved
Relocate stud on port forward vapor collection connection to top of flange midway between bolt holes (i.e. 12 o'clock position).
Condition: Unknown
Due 14 February 1994
Resolved 14 February 1994
Deck/Cargo
Issued 14 February 1994
Resolved
Disable "flushing flanges" on main vapor line so that it cannot be used as a vapor collection point (e.g. install permanently attached stud).
Condition: Unknown
Due 14 February 1994
Resolved 14 February 1994
Deck/Cargo
Issued 4 February 1994
Resolved
DECK SEAL FILL LINE VALVE LOCATED ON MAIN DECK LEAKS. REPLACE/REPAIR
Condition: Unknown
Due 18 February 1994
Resolved 14 February 1994
Lifesaving
Issued 4 February 1994
Resolved
BOTH LIFERAFTS ARE OUTDATED FOR ANNUAL INSPECTION. SERVICE
Condition: Unknown
Due 18 February 1994
Resolved 14 February 1994
Engineering
Issued 4 February 1994
Resolved
MAIN STEAM LINE IN PUMP ROOM HAS SLIGHT LEAK FROM WORN GASKET; REPLACE
Condition: Unknown
Due 18 February 1994
Resolved 14 February 1994
Deck/Cargo
Issued 4 February 1994
Resolved
DECK SEAL DRAIN LINE LOCATED IN PUMP ROOM (PORT SIDE) HAS TWO SOFT PATCHES INSTALLED BY SHIP'S CREW. REPAIR
Condition: Unknown
Due 18 February 1994
Resolved 14 February 1994
Navigation
Issued 1 March 1993
Resolved
BA List of Light (Vol. G, 1992) missing BA NTM corrections 45/92, 46/92, 47/92, and 48/92.
Condition: Unknown
Due 2 March 1993
Resolved 5 March 1993
Navigation
Issued 1 March 1993
Resolved
U.S. Chart 18653 (3rd Ed., 28SEP91) required for transit to Richmond, CA was not on board.
Condition: Unknown
Due 2 March 1993
Resolved 5 March 1993