Records from 1985 to 2005. Most recent: operational control imposed, 8 July 2005.
Inspection history · 40
8 July 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2419779
28 June 2005
ISPS III Exam · Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2406645
3 August 2004
ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2155206
9 May 2004
MTSA/ISPS Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2063050
12 March 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2023333
24 January 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1992774
6 November 2003
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1943086
6 November 2003
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1943642
28 May 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1622211
20 May 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1618456
20 January 2002
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1480047
25 June 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 291219
17 April 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 289091
9 June 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 278733
2 March 2000
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 61109
2 March 2000
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 275202
15 November 1998
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 422634
13 April 1998
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 538296
31 August 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 407354
29 March 1997
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 502833
8 May 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 390937
24 August 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 383224
24 May 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 378640
31 October 1994
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 371873
30 October 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 371743
25 March 1994
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 365510
29 December 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 363341
26 September 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 466212
23 June 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 359111
7 March 1993
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 356761
22 November 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 457829
4 September 1990
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 339098
24 December 1988
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 327533
11 February 1988
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 321309
20 November 1987
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 491067
16 April 1987
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 315524
15 November 1986
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 458944
16 March 1986
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 307566
19 September 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 442970
6 February 1985
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 300248
Navigation › Piloting/Steering › Gyro Compass
Issued 27 June 2005
Resolved
Vessel's Gyro Compass inoperable prior to entering port. Inbound Deviation was granted.
Due 28 June 2005
Resolved 28 June 2005
Resolution: Received technicians report attesting to satisfactory repairs. Vessel was allowed to enter port.
Fire Fighting › Fire Pumps
Issued 6 November 2003
Resolved
EMERGENCY FIRE PUMP IS INOPERABLE. LEGACY COMPONENT DESC: Arrangement
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2003
Resolved 7 November 2003
Resolution: Received report form class attesting to the proper operation.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 November 2003
Resolved
OWS oil hose is not repaired to original manufacturers standard. Unapproved modification. (SOLAS 74 I/11).
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 7 November 2003
Resolution: Received report from class attesting to repairs and proper operation
Engineering › Sea-water System (primary cooling) › Pump
Issued 6 November 2003
Resolved
Sea water cooling pump is leaking excessively (SOLAS 74 I/11).
Action required: 705 - Other - as specified
Due 6 December 2003
Resolved 7 November 2003
Resolution: Recieved report form class attesting to the proper repair and opertaion of the item.
Fire Fighting › Ventilation Systems
Issued 6 November 2003
Resolved
#4 and #2 fire dampers will not close completely (SOLAS II-2/11.5) LEGACY COMPONENT DESC: Ducts
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2003
Resolved 7 November 2003
Resolution: Recieved report form class attesting to the proper repair and opertaion of the item.
Lifesaving › Lifeboat
Issued 6 November 2003
Resolved
Starboard lifeboat motor will not start. (SOLAS 74 III/41.6.3)
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2003
Resolved 7 November 2003
Resolution: Recieved report form class attesting to the proper repair and opertaion of the item.
Electrical
Issued 25 June 2001
Resolved
MISSING PLASTIC COVERS FROM OVERHEAD LIGHTS IN ACCOMADATION SPACES.
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Fire Fighting
Issued 25 June 2001
Resolved
FIRE SUITS IN POOR CONDITIONS.
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Fire Fighting
Issued 17 April 2001
Resolved
FIRE FIGHTING SUITS IN POOR CONDITION. REPLACE/RENEW SUITS W/IN 30 DAYS.
Condition: Unknown
Due 2 July 2001
Resolved 2 July 2001
Electrical
Issued 17 April 2001
Resolved
PLASTIC COVERS MISSING FROM OVERHEAD LIGHTS IN ACCOMADATIONS. REPLACE COVERS W/IN 30 DAYS, IN ALL CABINS.
Condition: Unknown
Due 2 July 2001
Resolved 2 July 2001
Lifesaving
Issued 2 March 2000
Resolved
MAKE QUICK RELEASE LIFEBUOY ARRANGEMENT ON BRIDGEWINGS QUICK RELEASE. ENSURE SMOKE AND LIGHT ARRANGEMENT IS CORRECT.
Condition: Unknown
Due 3 March 2000
Resolved 3 March 2000
Fire Fighting
Issued 2 March 2000
Resolved
REPAIR NO.1 COMPRESSOR FOR LOW PRESSURE CO2 SYSTEM. SHAFT SEAL NEEDS TO BE REPLACED - CURRENTLY LEAKING/SEEPING. REPAIR PRIOR TO NEXT U.S. PORT AFTER FOREIGN.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Electrical
Issued 2 March 2000
Resolved
PROVIDE PROTECTIVE COVERS FOR FLUORESCENT LIGHT FIXTURES IN BERTHING SPACES. CORRECT PRIOR TO NEXT U.S. PORT AFTER FOREIGN.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Fire Fighting
Issued 2 March 2000
Resolved
REPAIR B0 BOUNDRY FIRE DOORS AT OFFICER'S LAUNDRY (HANDLE MISSING) AND CREW'S TOILET (PORT & STARBOARD - LOWER EDGE OF DOOR DOESN'T MEET FRAME). CORRECT PRIOR TO NEXT U.S. PORT AFTER FOREIGN.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Navigation
Issued 15 November 1998
Resolved
A DEFICIENCY OF 33 CFR 164.11(t0 IN THAT THE VESSEL HAD A STEERING MALFUNCTION WHILE ENTERING THE PORT. THE VESSEL WAS ISSUED A COTP ORDER TOREMAIN BEYOND BIG STONE ANCHORAGE. A TECH REPORT, ALONG WITH A CLASS REPORT HAD BEEN RECIEVED AND THE VESSEL WAS CLEARED.
Condition: Unknown
Due 15 November 1998
Resolved 20 November 1998
Lifesaving
Issued 31 August 1997
Resolved
PORT AND STARBOARD LIFEBOAT LIFELINE STARTING TO ROT. SOLAS 74 CHAP III REG41-7.3.
Condition: Unknown
Due 31 October 1997
Resolved 3 September 1997
Electrical
Issued 31 August 1997
Resolved
PHONE NOT RINGING IN STEERING. SOLAS 74 CHAP II-1 REG 29.10.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Electrical
Issued 31 August 1997
Resolved
LIGHT COVERS MISSING IN STEERING SPACE. SOLAS 74 CHAP II-1 REG 40
Condition: Unknown
Due 31 October 1997
Resolved 3 September 1997
Accommodation/Occupational Safety
Issued 31 August 1997
Resolved
TOILET IN HOSPITAL SPACE NOT FLUSHING. ILO-147.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Accommodation/Occupational Safety
Issued 31 August 1997
Resolved
LADDER AND RAIL, LEADING FROM BRIDGE DECK TO PORT BOAT DECK LOOSE._x001C_ ILO-147.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Engineering
Issued 31 August 1997
Resolved
EMERGENCY FIRE PUMP F/O LEAKS AND WILL NOT START. SOLAS 74
Condition: Unknown
Due 31 August 1997
Resolved 3 September 1997
Construction/Loadline
Issued 31 August 1997
Resolved
GAS TIGHT BULKHEAD CRACKED ON DECK #9, AT FRAME 95 AROUND GAS TIGHT DOOR. SOLAS 74 CHAP II-1 REG 14.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Construction/Loadline
Issued 31 August 1997
Resolved
SIDE OF DECK HOUSE HOLED AROUND GALLEY, LIFEBOAT DECK. SOLAS 74 CHAP II-1, REG 14.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Navigation
Issued 8 May 1996
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITH CHART #12327 MISSING CORRECTION #'S 43/95, 45/95, 46/95, 50/95, 2/96, 9/96, 13/96.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Engineering
Issued 24 May 1995
Resolved
Fuel/oil containment box located on weather deck aft of port lifeboat is holed and wasted, not meeting requirements of 33 CFR 155.320(a)(2). Repair required prior to transferring fuel/oil in U.S. waters and not later than 24JUN95.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Lifesaving
Issued 24 May 1995
Resolved
One SOLAS cover frame was wasted for stbd lifeboat, SOLAS 74/81. Make repairs to frame not later than 24JUN95.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Accommodation/Occupational Safety
Issued 24 May 1995
Resolved
Inboard rails are wasted on 3 incline ladders, bow, leading to winch deck. ILO 147 and general safety requirement.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Navigation
Issued 25 March 1994
Resolved
VESSEL WAS MISSING CORRECTIONS FOR U.S. CHARTS #12333, 12327, AND B.A. CHART #3204.
Condition: Unknown
Due 1 November 1994
Resolved 1 November 1994