MAURY USCG vessel records Sign in
← All vessels

SOUTHERN ACE

SOUTHERN ACE is a 1980 freight ship. The Coast Guard has recorded 40 inspections since 1985, most recently in July 2005, along with 28 deficiencies and 8 operational controls, 1 with no removal date recorded.

Records from 1985 to 2005. Most recent: operational control imposed, 8 July 2005.

Built
1980
Last inspected
8 July 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

7929712 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228110
Flag
LIBERIA
—
Maury page id
psix-228110

Inspections, by type

…with no type recorded32
Years with a record 18 calendar years (1985–2005)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it45688 - Regulatory (Subpart C or D), Gross Ton
45688 - Convention (Subpart B), Gross Ton
18355 - Dead Weight, Ton
13707 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 40

8 July 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2419779
28 June 2005 ISPS III Exam · Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2406645
3 August 2004 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2155206
9 May 2004 MTSA/ISPS Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2063050
12 March 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2023333
24 January 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1992774
6 November 2003 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1943086
6 November 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1943642
28 May 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1622211
20 May 2002 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1618456
20 January 2002 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1480047
25 June 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 291219
17 April 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 289091
9 June 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 278733
2 March 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 61109
2 March 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 275202
15 November 1998 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 422634
13 April 1998 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 538296
31 August 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 407354
29 March 1997 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 502833
8 May 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 390937
24 August 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 383224
24 May 1995 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 378640
31 October 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 371873
30 October 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 371743
25 March 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 365510
29 December 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 363341
26 September 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 466212
23 June 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 359111
7 March 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 356761
22 November 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 457829
4 September 1990 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 339098
24 December 1988 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 327533
11 February 1988 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 321309
20 November 1987 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 491067
16 April 1987 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 315524
15 November 1986 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 458944
16 March 1986 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 307566
19 September 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 442970
6 February 1985 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 300248

Deficiency record · 28

Navigation › Piloting/Steering › Gyro Compass
Issued 27 June 2005 Resolved
Vessel's Gyro Compass inoperable prior to entering port. Inbound Deviation was granted.
Due 28 June 2005
Resolved 28 June 2005
Resolution: Received technicians report attesting to satisfactory repairs. Vessel was allowed to enter port.
Fire Fighting › Fire Pumps
Issued 6 November 2003 Resolved
EMERGENCY FIRE PUMP IS INOPERABLE. LEGACY COMPONENT DESC: Arrangement
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2003
Resolved 7 November 2003
Resolution: Received report form class attesting to the proper operation.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 November 2003 Resolved
OWS oil hose is not repaired to original manufacturers standard. Unapproved modification. (SOLAS 74 I/11).
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 7 November 2003
Resolution: Received report from class attesting to repairs and proper operation
Engineering › Sea-water System (primary cooling) › Pump
Issued 6 November 2003 Resolved
Sea water cooling pump is leaking excessively (SOLAS 74 I/11).
Action required: 705 - Other - as specified
Due 6 December 2003
Resolved 7 November 2003
Resolution: Recieved report form class attesting to the proper repair and opertaion of the item.
Fire Fighting › Ventilation Systems
Issued 6 November 2003 Resolved
#4 and #2 fire dampers will not close completely (SOLAS II-2/11.5) LEGACY COMPONENT DESC: Ducts
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2003
Resolved 7 November 2003
Resolution: Recieved report form class attesting to the proper repair and opertaion of the item.
Lifesaving › Lifeboat
Issued 6 November 2003 Resolved
Starboard lifeboat motor will not start. (SOLAS 74 III/41.6.3)
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2003
Resolved 7 November 2003
Resolution: Recieved report form class attesting to the proper repair and opertaion of the item.
Electrical
Issued 25 June 2001 Resolved
MISSING PLASTIC COVERS FROM OVERHEAD LIGHTS IN ACCOMADATION SPACES.
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Fire Fighting
Issued 25 June 2001 Resolved
FIRE SUITS IN POOR CONDITIONS.
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Fire Fighting
Issued 17 April 2001 Resolved
FIRE FIGHTING SUITS IN POOR CONDITION. REPLACE/RENEW SUITS W/IN 30 DAYS.
Condition: Unknown
Due 2 July 2001
Resolved 2 July 2001
Electrical
Issued 17 April 2001 Resolved
PLASTIC COVERS MISSING FROM OVERHEAD LIGHTS IN ACCOMADATIONS. REPLACE COVERS W/IN 30 DAYS, IN ALL CABINS.
Condition: Unknown
Due 2 July 2001
Resolved 2 July 2001
Lifesaving
Issued 2 March 2000 Resolved
MAKE QUICK RELEASE LIFEBUOY ARRANGEMENT ON BRIDGEWINGS QUICK RELEASE. ENSURE SMOKE AND LIGHT ARRANGEMENT IS CORRECT.
Condition: Unknown
Due 3 March 2000
Resolved 3 March 2000
Fire Fighting
Issued 2 March 2000 Resolved
REPAIR NO.1 COMPRESSOR FOR LOW PRESSURE CO2 SYSTEM. SHAFT SEAL NEEDS TO BE REPLACED - CURRENTLY LEAKING/SEEPING. REPAIR PRIOR TO NEXT U.S. PORT AFTER FOREIGN.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Electrical
Issued 2 March 2000 Resolved
PROVIDE PROTECTIVE COVERS FOR FLUORESCENT LIGHT FIXTURES IN BERTHING SPACES. CORRECT PRIOR TO NEXT U.S. PORT AFTER FOREIGN.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Fire Fighting
Issued 2 March 2000 Resolved
REPAIR B0 BOUNDRY FIRE DOORS AT OFFICER'S LAUNDRY (HANDLE MISSING) AND CREW'S TOILET (PORT & STARBOARD - LOWER EDGE OF DOOR DOESN'T MEET FRAME). CORRECT PRIOR TO NEXT U.S. PORT AFTER FOREIGN.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Navigation
Issued 15 November 1998 Resolved
A DEFICIENCY OF 33 CFR 164.11(t0 IN THAT THE VESSEL HAD A STEERING MALFUNCTION WHILE ENTERING THE PORT. THE VESSEL WAS ISSUED A COTP ORDER TOREMAIN BEYOND BIG STONE ANCHORAGE. A TECH REPORT, ALONG WITH A CLASS REPORT HAD BEEN RECIEVED AND THE VESSEL WAS CLEARED.
Condition: Unknown
Due 15 November 1998
Resolved 20 November 1998
Lifesaving
Issued 31 August 1997 Resolved
PORT AND STARBOARD LIFEBOAT LIFELINE STARTING TO ROT. SOLAS 74 CHAP III REG41-7.3.
Condition: Unknown
Due 31 October 1997
Resolved 3 September 1997
Electrical
Issued 31 August 1997 Resolved
PHONE NOT RINGING IN STEERING. SOLAS 74 CHAP II-1 REG 29.10.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Electrical
Issued 31 August 1997 Resolved
LIGHT COVERS MISSING IN STEERING SPACE. SOLAS 74 CHAP II-1 REG 40
Condition: Unknown
Due 31 October 1997
Resolved 3 September 1997
Accommodation/Occupational Safety
Issued 31 August 1997 Resolved
TOILET IN HOSPITAL SPACE NOT FLUSHING. ILO-147.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Accommodation/Occupational Safety
Issued 31 August 1997 Resolved
LADDER AND RAIL, LEADING FROM BRIDGE DECK TO PORT BOAT DECK LOOSE._x001C_ ILO-147.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Engineering
Issued 31 August 1997 Resolved
EMERGENCY FIRE PUMP F/O LEAKS AND WILL NOT START. SOLAS 74
Condition: Unknown
Due 31 August 1997
Resolved 3 September 1997
Construction/Loadline
Issued 31 August 1997 Resolved
GAS TIGHT BULKHEAD CRACKED ON DECK #9, AT FRAME 95 AROUND GAS TIGHT DOOR. SOLAS 74 CHAP II-1 REG 14.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Construction/Loadline
Issued 31 August 1997 Resolved
SIDE OF DECK HOUSE HOLED AROUND GALLEY, LIFEBOAT DECK. SOLAS 74 CHAP II-1, REG 14.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Navigation
Issued 8 May 1996 Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITH CHART #12327 MISSING CORRECTION #'S 43/95, 45/95, 46/95, 50/95, 2/96, 9/96, 13/96.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Engineering
Issued 24 May 1995 Resolved
Fuel/oil containment box located on weather deck aft of port lifeboat is holed and wasted, not meeting requirements of 33 CFR 155.320(a)(2). Repair required prior to transferring fuel/oil in U.S. waters and not later than 24JUN95.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Lifesaving
Issued 24 May 1995 Resolved
One SOLAS cover frame was wasted for stbd lifeboat, SOLAS 74/81. Make repairs to frame not later than 24JUN95.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Accommodation/Occupational Safety
Issued 24 May 1995 Resolved
Inboard rails are wasted on 3 incline ladders, bow, leading to winch deck. ILO 147 and general safety requirement.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Navigation
Issued 25 March 1994 Resolved
VESSEL WAS MISSING CORRECTIONS FOR U.S. CHARTS #12333, 12327, AND B.A. CHART #3204.
Condition: Unknown
Due 1 November 1994
Resolved 1 November 1994

Ownership record