Records from 1988 to 1999. Most recent: inspection, 3 September 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 7
3 September 1999
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 432319
16 April 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 427655
12 September 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 112797
11 September 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 420187
28 January 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 399930
28 February 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 328712
3 January 1988
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 320495
Lifesaving
Issued 3 September 1999
Resolved
DAVIT LIMIT SWITICH NOT OPERATING PROPERLY. REPAIR/RENEW AND PROVIDE CLASS REPORT PRIOR TO 03OCT99
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Unknown
Issued 3 September 1999
Resolved
VESSEL SECONDARY RADAR INOPERABLE DUE TO HURRICANE CINDY. HAVE RADAR REPAIRED PRIOR TO DEPARTURE AND PROVIDE TECH REPORT
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Unknown
Issued 3 September 1999
Resolved
VESSEL'S CHARTS AND PUBLICATIONS ARE OUTDATED. RENEW PUBS PRIOR TO DEPARTURE US WATERS.
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Unknown
Issued 3 September 1999
Resolved
VESSEL'S SIGNALING LAMP IN OPERABLE. REPAIR/RENEW LAMP PRIOR TO 04OCT99.
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Unknown
Issued 3 September 1999
Resolved
CAPTIAN AND ONE CREW MEMBER INJURED DURING TRANSIT THROUGH HURRICANE CINDY.PROVIDE MEDICAL CERT FIT FOR SEA PRIOR TO DEPARTURE US WATERS
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Fire Fighting
Issued 3 September 1999
Resolved
FIRE HOSE STATION UPPER AFT STBD SIDE LEAKS EXCESSIVE, MISSING FIRE HOSE AND NOZZLE. RENEW/REPLACE AND PROVIDE CLASS REPORT PRIOR TO DEPARTURE US WATERS.
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Accommodation/Occupational Safety
Issued 3 September 1999
Resolved
SEWAGWE PIPING LEAKS. REPAIR/RENEW AND PROVIDE CLASS REPORT PRIOR TO DEPARTURE.
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Engineering
Issued 3 September 1999
Resolved
SOFT PATCHES LOCATED IN ENGINE ROOM ON COOLING WATER PIPING. FRESH AND SALTWATER. RENEW REPAIR AND PROVIDE CLASS REPORT PRIOR TO DEPARTURE US WATERS.
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Navigation
Issued 3 September 1999
Resolved
NO COMMUNCATION BETWEEN BRIDGE AND STEERING COMPARTMENT. REPAIR/RENEW AND PROVIDE CLASS REPORT PRIOR TO DEPARTURE.
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Engineering
Issued 3 September 1999
Resolved
FUEL LEAKS ON INBOARD STBD GEN AND COOLING LEAKS ON PORT GEN. RENEW/REPAIR AND PROVIDE CLASS REPORT PRIOR TO DEPARTURE.
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Fire Fighting
Issued 3 September 1999
Resolved
VESSEL GENERAL ALARM INOPERATIVE. REPAIR/RENEW PRIOR TO DEPARTURE AND PROVIDE CLASS REPORT.
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Documentation
Issued 11 September 1998
Resolved
PROVIDE ON BOARD FLAG STATE LICENSES OR LETTER ACCEPTING FOREIGN LICENSES_x001C_ FROM OTHER THAN FLAG STATE._x001C_ STCW 78 II/2
Condition: Unknown
Due 26 May 1999
Resolved 26 May 1999