MAURY USCG vessel records Sign in
← All vessels

SEALINK

SEALINK is a 1981 freight ship. The Coast Guard has recorded 26 inspections since 1985, most recently in December 2007, along with 36 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 1985 to 2007. Most recent: inspection, 17 December 2007.

Built
1981
Last inspected
17 December 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7930670 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228124
Flag
PANAMA
—
Maury page id
psix-228124

Inspections, by type

…with no type recorded20
…past their stated due date1
Years with a record 18 calendar years (1985–2007)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it35575 - Convention (Subpart B), Gross Ton
65015 - Dead Weight, Ton
21065 - Convention (Subpart B), Net Ton
76785 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 26

17 December 2007 PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3114850
12 June 2005 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2387393
19 May 2004 Annual Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2073205
8 January 2002 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1476425
13 December 2001 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 296018
4 July 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 430358
13 August 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 419211
25 November 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 410052
25 November 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 397483
11 May 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 390766
14 December 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 373368
14 December 1994 Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 837249
21 June 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 359003
21 September 1992 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 353298
20 May 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 350674
23 March 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 471268
13 November 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 532146
8 March 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 342299
28 November 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 333843
28 December 1988 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 327584
11 October 1988 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 521133
21 March 1988 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 322080
4 June 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 316618
21 September 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 311553
6 November 1985 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 486064
29 January 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 300300

Deficiency record · 36

Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 17 December 2007 Resolved
Echo depth sounder was found inoperable
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2007
Resolution: Recieved class report attesting to the repair of the echo depth sounder.
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 8 January 2002 Resolved
LOOSE DEBRIS IN COMPARTMENT AFT OF ENGINE CONTROL ROOM/SOLAS/FAX STATEMENT TO USCG IDENTIFYING REMOVAL OF DEBRIS
Due 18 January 2002
Resolved 8 January 2002
Engineering › Generator (propulsion/auxiliary-electric) › Indicator Circuitry
Issued 8 January 2002 Resolved
RPM INDICATOR FOR #2 GENERATOR INOP./SOLAS/REPAIR AND FAX RECEIPT OF ORDER TO USCG
Condition: Unknown
Due 8 January 2002
Resolved 8 January 2002
Resolution: RECEIVED CLASS SURVEY INDICATING REPAIR
Engineering › Generator (propulsion-electric)
Issued 8 January 2002 Resolved
FILTERS FOR ALL GENERATORS CLOGGED/SOLAS/REPAIR TO SATISFACTION OF CLASS LEGACY COMPONENT DESC: FILTERS
Condition: Improper/Lack of Maintenance
Due 8 January 2002
Resolved 8 January 2002
Resolution: CLASS SURVEY INDICATES REPLACEMENT OF FILTERS
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 13 December 2001 Resolved
REPLACE PATCHED COPPER FIXED CO2 SYSTEM LINE/SOLAS/REPLACE TO SATISFACTION OF CLASS SOCIETY
Condition: Improper/Lack of Maintenance
Due 18 December 2001
Resolved 18 December 2001
Resolution: CORRECTED BY CLASS
Electrical
Issued 13 December 2001 No resolution recorded
VENT LOUVERS IN EMER. BATTERY ROOM WASTED/SOLAS/REPAIR TO SATISFACTION OF CLASS SOCIETY
Condition: Unknown
Due 18 January 2002 — due date passed with no resolution recorded
Resolution: CORRECTED BY CLASS SOCIETY
Fire Fighting › Combustible Materials
Issued 13 December 2001 Resolved
REMOVE 'HOT PLATE' FROM ENGINE CONTROL ROOM/SOLAS/FAX STATEMENT TO USCG IDENTIFYING REMOVAL OF HOT PLATE
Due 18 December 2001
Resolved 18 December 2001
Resolution: CLEARED BY FAX
Engineering
Issued 4 July 1999 Resolved
GAUGE ON OWS INOPERABLE._x001C_ _x001C_ MARPOL 73/78 ANNEX I/11_x001C_
Condition: Unknown
Due 4 July 1999
Resolved 5 July 1999
Lifesaving
Issued 4 July 1999 Resolved
STOPPER ASMBLY ON PORT AFT DAVIT WASTED AND BROKEN FREE._x001C_ _x001C_ SOLAS 60 REG I/11_x001C_
Condition: Unknown
Due 4 July 1999
Resolved 5 July 1999
Fire Fighting
Issued 13 August 1998 Resolved
Provide class report proving proper operation of emergency fire pump prior to departing Portland, OR._x001C_ SOLAS 74 II-2/4.3.3.2
Condition: Unknown
Due 25 August 1998
Resolved 28 August 1998
Accommodation/Occupational Safety
Issued 13 August 1998 Resolved
Properly repair two wasted steps on aft of house prior to next U.S. port call after sailing foreign._x001C_ ILO-147
Condition: Unknown
Due 5 July 1999
Resolved 5 July 1999
Electrical
Issued 25 November 1997 Resolved
ELECTRICAL SAFETY MATTING IN FRONT OF MAIN SWITCHBOARD MISSING.
Condition: Unknown
Due 14 August 1998
Resolved 14 August 1998
Lifesaving
Issued 25 November 1997 Resolved
UNSAFE STEP, PORT SIDE LADDER AFT TO BOAT DECK-WASTED MATERIAL.
Condition: Unknown
Due 14 August 1998
Resolved 14 August 1998
Accommodation/Occupational Safety
Issued 25 November 1997 Resolved
CEMENT PATCH ON TOP OF MSD TANK.
Condition: Unknown
Due 14 August 1998
Resolved 14 August 1998
Engineering
Issued 25 November 1997 Resolved
LEAKING FUEL OIL DRAIN LINE IN ENGINE ROOM AFT OF MAIN ENGINE, LOWER LEVEL.
Condition: Unknown
Due 14 August 1998
Resolved 14 August 1998
Lifesaving
Issued 25 November 1997 Resolved
LEAKING FRESH WATER PIPE ABOVE FEED FILTER TANK IN ENGINE ROOM._x001C_
Condition: Unknown
Due 14 August 1998
Resolved 14 August 1998
Electrical
Issued 25 November 1997 Resolved
MISSING LIGHT COVER NEAR STARBOARD GENERATOR.
Condition: Unknown
Due 14 August 1998
Resolved 14 August 1998
Accommodation/Occupational Safety
Issued 25 November 1996 Resolved
ALL EXTERIOR DOORS NOT WEATHER TIGHT OR EASILY OPENED. ILO 147
Condition: Unknown
Due 4 December 1997
Resolved 4 December 1997
Unknown
Issued 25 November 1996 Resolved
EXPIRED MEDICATION IN HOSPITAL. ILO 147
Condition: Unknown
Due 4 December 1997
Resolved 4 December 1997
Lifesaving
Issued 25 November 1996 Resolved
MISSING WEAK LINK FOR FORWARD LIFE RAFT. SOLAS 74 AMD, REG III/29
Condition: Unknown
Due 4 December 1997
Resolved 4 December 1997
Unknown
Issued 25 November 1996 Resolved
MISSING MECHANICAL PLUGS FOR OIL CONTAINMENT. 33 CFR 155.310
Condition: Unknown
Due 4 December 1997
Resolved 4 December 1997
Accommodation/Occupational Safety
Issued 25 November 1996 Resolved
SOFT PATCHES FOUND ON THE MARINE SANITATION DEVICE (MSD) AND MSD PIPING; MARPOL 73/78 ANNEX IV REG 3
Condition: Unknown
Due 4 December 1997
Resolved 4 December 1997
Electrical
Issued 25 November 1996 Resolved
FOUND BATTERIES ON DECK IN EMERGENCY BATTERY ROOM. SOLAS II-1 REG 45,9.1
Condition: Unknown
Due 4 December 1997
Resolved 4 December 1997
Engineering
Issued 11 May 1996 Resolved
EXCESSIVE OIL ON DECK OF THE FUEL OIL PURIFIER ROOM; SOLAS 74, CH II-2, REGULATION 33.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Fire Fighting
Issued 11 May 1996 Resolved
EMERGENCY FIRE PUMP DEPENDENT UPON AN AIR COMPRESSOR LOCATED IN THE ENGINE ROOM FOR PRIMING.
Condition: Unknown
Due 11 May 1996
Resolved 3 June 1996
Documentation
Issued 11 May 1996 Resolved
VESSEL'S LOADLINE MARKINGS WERE NOT STENCILLED WITH A CONTRASTING COLOR RELATIVE TO THE VESSEL'S HULL; INTERNATIONAL LOADLINE CONVENTION, CH II, ANNEX I, RULE VI.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Accommodation/Occupational Safety
Issued 11 May 1996 Resolved
SOFT PATCHES WERE FOUND ON THE MARINE SANITATION DEVICE (MSD) AND MSD PIPING; MARPOL 73/78 ANNEX IV, REGULATION 3.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Lifesaving
Issued 14 December 1994 Resolved
VESSELS PORT LIFEBOAT DAVIT BLOCKS WERE WASTED.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Documentation
Issued 8 March 1991 Resolved
Information required by 33CFR750(a)(1),(2),(5),(7), and (9), addresseing the procedures for tending moorings, reporting oil discharges into the water, topping off tanks, and contents of the transfer system line diagram were not included in the vessel oil transfer procedures.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Navigation
Issued 28 December 1988 Resolved
VESSEL'S MANEUVERING INFORMATION DID NOT CONTAIN THE NORMAL LOAD AND NORMAL BALLAST CONDITION FOR CALM WEATHER, NO CURRENT, DEEP WATER CONDITIONS, AND CLEAN HULL AS REQUIRED BY 33 CFR 164.35(G)(6)(I)THRU(G)(6) (IV).
Condition: Unknown
Due 28 December 1988
Resolved 28 December 1988
Navigation
Issued 28 December 1988 Resolved
VESSEL'S AUOTMATIC RADAR PLOTTING AIDS (ARPA) DID NOT HAVE A PERMANENTLY AFFIXED LABEL CONTAINING THE FOLLOWING STATEMENT: "THIS DEVICE WAS DESIGNEDAND MANUFACTURED TO COMPLKY WITH THE IMO PERFORMANCE STANDARDS FOR AUTOMATIC RADAR PLOTTING AIDS(ARPA) AS REQUIRED BY 33 CFR 164.38(D)(1)(II).
Condition: Unknown
Due 28 December 1988
Resolved 28 December 1988
Engineering
Issued 28 December 1988 Resolved
VESSEL'S OILY WATER SEPERATOR ALARM WAS NOT MAINTAINED INOPERABLE CONDITIONTO MEET THE CONDITIONS OF 33 CFR 155.370(A)(2).
Condition: Unknown
Due 28 December 1988
Resolved 28 December 1988
Navigation
Issued 21 September 1986 Resolved
CHART 18521 NOT CURRENTLY CORRECTED UP TO DATE FROM APPLICABLE NOTICES TO MARINERS.
Condition: Unknown
Due 21 September 1986
Resolved 21 September 1986
Navigation
Issued 21 September 1986 Resolved
VESSEL DID NOT HAVE A COPY OF THE INLAND NAVIGATION RULES ABOARD.
Condition: Unknown
Due 21 September 1986
Resolved 21 September 1986
Documentation
Issued 21 September 1986 Resolved
OIL RECORD BOOK PART I (MACHINERY SPACE OPERATIONS) USING IMPROPER CODES TO INDICATE DISPOSAL OF BILGE WATER & OILY RESIDUES.
Condition: Unknown
Due 21 September 1986
Resolved 21 September 1986
Documentation
Issued 21 September 1986 Resolved
OIL TRANSFER PROCEDURES MISSING LIST OF PRODUCTS TRANSFERRED, NUMBER OF PERSONS REQUIRED ON DUTY, DUTIES BY TITLE OF PERSONS REQUIRED, PROCEDURES FOR COMMUNICATIONS, AND PROCEDURES FOR TOPPING OFF TANKS.
Condition: Unknown
Due 21 September 1986
Resolved 21 September 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.