Records from 1984 to 2009. Most recent: inspection, 3 March 2009.
Inspection history · 21
3 March 2009
ISPS I Exam · COE-Offshore · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3427423
3 March 2009
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3427978
28 February 2009
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3425497
29 August 2008
ISPS I Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3303192
20 August 2008
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3308506
18 August 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3302280
18 August 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3302288
16 August 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3299858
13 January 2007
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2857050
12 January 2007
PII Safety Exam · Ballast Water Examination · ISPS I Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2854877
10 January 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2853559
25 July 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 279976
25 April 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 402710
18 November 1990
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 340224
20 September 1989
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 332697
16 May 1989
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 330387
13 October 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 473671
8 March 1988
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 321853
18 December 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 313365
31 January 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 529836
21 August 1984
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 297487
Construction/Loadline › Penetrations › Gasket
Issued 4 March 2009
Resolved
Cargo hatch covers #1,3,4,6,&9 have seal gaskets that are separated from the gasket brackets on port & starboard side. Cargo hatch cover #6 missing seal gasket material on the port side cargo hatch cover #2 has spot welds holding steel bracket material in place. These conditions compromise the hatch covers ability to secure properly & maintain weather tight integrity. ICLL 66, Ch. II, Reg.16(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2009
Resolution: Class attended vessel and cleared deficiency.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 March 2009
Resolved
Crew is not able to show proper OWS operation due to fill pipe for priming the filter equipment (two stage system) not supplying water. This presents an environmental threat if equipment is not functioning properly. MARPOL(2006) Annex I, Reg.14(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2009
Resolution: Class attended vessel and cleared deficiency.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 4 March 2009
Resolved
There is excessive fuel & lube oil underneath both generators. This is due to numerous seal breaks on both generator sets. This represents a possible fire hazard & if left unchecked, a possible failure to both generator sets. SOLAS 74 Ch.1, Reg.11
Action required: 705 - Other - as specified
Due 4 April 2009
Resolved 10 March 2009
Resolution: Class attended vessel and cleared deficiency.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 4 March 2009
Resolved
Two fire door entrances into the galley space are missing gaskets and one door does not close properly, which causes the doors not to function as designed for fire protection. SOLAS 74 II-2, Reg. 23(d)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2009
Resolution: Class attended vessel and cleared deficiency.
Navigation
Issued 16 May 1989
Resolved
A VIO OF 33 CFR 164.30 IN THAT U.S. CHARTS #12221 AND #12245, USED BY THE VSL, WERE NOT CORRECTED TO NTM 05/89, WHICH WAS REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSL'S ROUTE FROM VA CAPES TO NORFOLK & SOUTHERN PIER, NORFOLK,VA.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Navigation
Issued 16 May 1989
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE USCG LIGHT LIST, VOL II USED BY THE VSL,WAS NOT CORRECTED TO NTM 05/89 WHICH WAS REASONABLY AVAILABLE AND CONTAINEDCORRECTIONS THA WERE APPLICABLE TO THE VSL'S ROUTE FROM VA CAPES TO NORFOLK& SOUTHERN PIER, NORFOLK VA.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Navigation
Issued 16 May 1989
Resolved
A VIO OF 33 CFR 164.38(D)(1) IN THAT THE ARPA INSTALLED ON VESSEL DID NOT HAVE THE REQUIRED LABEL.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Navigation
Issued 8 March 1988
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE MOST CURRENT ED OF U.S. TIDAL CURRENT TABLES, OR ITS FOREIGN EQUIV, AS REQ BY 33 CFR 164.33(A)(3)(II), WAS NOT O/B. THE VSL HAD NO TIDAL CURRENT TABLES O/B. THE MOST CURRENT ED OF U.S. TIDAL CURRENT TABLES IS DTD 1988.
Condition: Unknown
Due 8 March 1988
Resolved 8 March 1988
Navigation
Issued 18 December 1986
Resolved
A VIO OF 33 CFR 164.30 IN THAT U.S. CHART #12222, USED BY THE VSL, WAS NOT CORRECTED TO NTM 35/86, WHICH WAS REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSL'S ROUTE FROM VA CAPES TO N & W COAL PIER NORFOLK, VA. NO FOREIGN EQUIV O/B.
Condition: Unknown
Due 18 December 1986
Resolved 18 December 1986