MAURY USCG vessel records Sign in
← All vessels

HIGH FIDELITY

HIGH FIDELITY is a 1981 tank ship. The Coast Guard has recorded 52 inspections since 1984, most recently in October 2003, along with 34 deficiencies and 3 operational controls.

Records from 1984 to 2003. Most recent: inspection, 9 October 2003.

Built
1981
Last inspected
9 October 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7931181 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228129
Flag
UNKNOWN
—
Maury page id
psix-228129

Inspections, by type

…with no type recorded34
Years with a record 18 calendar years (1984–2003)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it30045 - Regulatory (Subpart C or D), Gross Ton
55500 - Dead Weight, Ton
66510 - Displacement, Ton
17788 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 52

9 October 2003 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1924446
6 October 2003 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1926694
15 September 2003 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1905099
19 July 2003 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1850577
30 May 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1806486
23 May 2003 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1799835
8 November 2002 Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1700803
9 July 2002 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1648143
17 November 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 295419
7 September 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 769540
6 September 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 190110
17 August 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 292971
17 May 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 290298
17 May 2001 Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1063414
4 January 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 436192
13 December 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 436142
13 December 1999 Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 812608
1 December 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 423054
1 December 1998 Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 806352
6 January 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 399178
21 December 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 398609
13 November 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 397320
18 March 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 388944
3 January 1996 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 511843
30 May 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 502213
11 November 1992 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 962387
23 October 1992 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 353863
23 October 1992 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1468276
22 June 1992 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 506493
23 December 1991 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 509007
16 December 1991 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 447792
16 December 1991 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 950631
20 November 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1248009
27 August 1991 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1003702
30 April 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 343721
30 April 1991 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1200838
25 February 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 484477
7 August 1990 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1218325
28 June 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 477469
25 November 1988 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 327052
25 November 1988 Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 895626
4 August 1988 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 324846
6 June 1988 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 439880
5 December 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 319979
5 December 1987 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1310687
5 December 1987 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1310691
10 December 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 313148
20 September 1986 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 312391
28 February 1986 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 462842
8 July 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 302926
25 June 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 302729
20 December 1984 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 536536

Deficiency record · 34

Deck/Cargo › Holds/Tanks
Issued 19 July 2003 Resolved
Have Class testify to the satisfactory operation of 4p, 4c, 4s, 6c and 4c tank level indicators prior to loading cargo in US waters. LEGACY COMPONENT DESC: Liquid Level Gaging
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 October 2003
Resolution: RECEIVED A CLASS REPORT VIA FAX CLEARING ALL OUTSTANDING DEFICIENCIES 00 REMAIN OUTSTANDING
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 19 July 2003 Resolved
Have Marine Chemist certify cargo pump room safe for entry and notify USCG for pump room inspection at next US port. LEGACY COMPONENT DESC: Cargo Pump
Action required: 15 - Rectify deficiencies by next port
Resolved 15 September 2003
Resolution: Done this date
Navigation › Collision/Grounding Avoidance
Issued 23 May 2003 Resolved
LOD ISSUED TO M/T FIDELITY FOR NON-OPERATIONAL SECONDARY RADAR. REPAIR TO BE MADE PRIOR TO DEPARTURE. TECH REPORT MUST BE SUBMITTED BEFORE LOD WILL BE RESCINDED. LEGACY COMPONENT DESC: Radar
Action required: 17 - Rectify deficiencies prior to departure
Due 24 May 2003
Resolved 25 May 2003
Resolution: RECIEVED TECH REPORT SECONDARY RADAR WORKING PROPERLY.
Deck/Cargo › Cargo Stowage
Issued 9 July 2002 Resolved
Vessel reported potential small leak between #7 port wing cargo tank & #7 port ballast tank evidenced by hissing sound of air due to pressure in tank from IGS and by 11% LEL in ballast tank. Determine source of LEL and make repairs as necessary. Provide class report. LEGACY COMPONENT DESC: Containment
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2002
Resolved 10 July 2002
Resolution: Vessel made temporary repairs to pinhole leaks in bulkhead to satisfaction of class. Class report received. Permanent repairs required by Jan 03.
Deck/Cargo › Cargo Stowage
Issued 9 July 2002 Resolved
Intermittent failure of audible Overfill alarm on deck. (33 CFR 155.480). Make repairs to audible alarms to the satisfaction of class. LEGACY COMPONENT DESC: Alarms
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2002
Resolved 9 July 2002
Resolution: Vessel replaced alarm and tested system. Class report provided.
Deck/Cargo
Issued 17 May 2001 Resolved
DECK AIR LINE HAS SOFT PATCH.
Condition: Unknown
Due 17 August 2001
Resolved 17 August 2001
Deck/Cargo
Issued 17 May 2001 Resolved
VESSEL COULD NOT PROVIDE EVIDENCE THAT IGS P/V BREAKER WAS FILLED TO THE CORRECT LEVEL.
Condition: Unknown
Due 17 August 2001
Resolved 17 August 2001
Deck/Cargo
Issued 17 May 2001 Resolved
CARGO STEAM HEATING LINE WASTED.
Condition: Unknown
Due 17 August 2001
Resolved 17 August 2001
Deck/Cargo
Issued 1 December 1998 Resolved
COMPLETE REPAIRS FOR THE AUTOMATIC GAUGING OF CARGO TANKS. PROVIDE TECHNICIAN'S REPORT ATTESTING PROPER REPAIR.
Condition: Unknown
Due 1 January 1999
Resolved 8 December 1998
Fire Fighting
Issued 21 December 1996 Resolved
Repair exhaust leak on emergency fire pump prior to next US port, as per SOLAS 74/78 II-2/21.
Condition: Unknown
Due 6 January 1997
Resolved 6 January 1997
Lifesaving
Issued 21 December 1996 Resolved
Repair broken handrail on starboard lifeboat hull where broken, as per Solas 74 (unamended) III/11(a).
Condition: Unknown
Due 6 January 1997
Resolved 6 January 1997
Documentation
Issued 21 December 1996 Resolved
Provide certification of lifting pressures for P/V valves on cargo tanks, as per 33CFR156.170.
Condition: Unknown
Due 6 January 1997
Resolved 6 January 1997
Deck/Cargo
Issued 21 December 1996 Resolved
Repair leak on cargo steam line, as per ILO 147.
Condition: Unknown
Due 6 January 1997
Resolved 6 January 1997
Navigation
Issued 18 March 1996 Resolved
VESSEL REQUESTED AND GRANTED A LETTER OF DEVIATION FOR AN INOPERABLE GYRO COMPASS.
Condition: Unknown
Due 20 March 1996
Resolved 18 March 1996
Construction/Loadline
Issued 23 October 1992 Resolved
Have a marine chemist certify the cargo pump room and one (1) ballast tank in the midbody section safe for entry and make these spaces available for inspection by a Coast Guard Marine inspector prior to cargo operations at the next U.S. port.
Condition: Unknown
Due 23 October 1992
Resolved 23 October 1992
Deck/Cargo
Issued 20 November 1991 Resolved
MAKE PERMANENT REPAIRS TO CARGO TANKS 2C,4C, AND 6C PRIOR TO ENTERING IN NEXT U.S. PORT.
Condition: Unknown
Due 20 November 1991
Resolved 20 November 1991
Deck/Cargo
Issued 27 August 1991 Resolved
REPAIR AND PROVE PROPER OPERATION OF THE INERT GAS PLANT HIGH INERT GAS TEMPERATURE SENSOR/ALARM SYSTEM PRIOR TO RETURNING TO U.S. PORTS AND IN NO CASE LATER THAN 27 AUGUST 1992.
Condition: Unknown
Due 27 August 1991
Resolved 27 August 1991
Navigation
Issued 27 August 1991 Resolved
PROVIDE U.S. CHART #12324 OR EQUIVALENT PROPERLY UPDATED, NOTICES TO LOCAL MARINERS #S 29 THRU 33, AND COAST PILOT #2 OR EQUIVALENT PRIOR TO DEPARTINGTHE PORT OF NEW YORK AND IN NO CASE LATER THAN 27 AUGUST 1992.
Condition: Unknown
Due 27 August 1991
Resolved 27 August 1991
Documentation
Issued 27 August 1991 Resolved
REVISE OIL TRANSFER PROCEDURES TO PROPERLY REFLECT THE CONTENTS REQUIRED BY33 CFR 155.750 PRIOR TO RETURNING TO U.S. WATERS AND IN NO CASE LATER THAN 27 AUGUST 1992.
Condition: Unknown
Due 27 August 1991
Resolved 27 August 1991
Electrical
Issued 27 August 1991 Resolved
REPAIR AND PROVE PROPER OPERATION OF THE AUTOMATIC ELECTRICAL STARTERS FOR THE EMERGENCY GENERATOR AND EMERGENCY FIRE PUMP PRIOR TO RETURNING TO U.S. PORTS AND IN NO CASE LATER THAN 27 AUGUST 1992.
Condition: Unknown
Due 27 August 1991
Resolved 27 August 1991
Deck/Cargo
Issued 30 April 1991 Resolved
OUTSTANDING DNV RECOMMENDATIONS FOR REPAIRS TO 2C, 4C, AND 6C CARGO TANKS MVI LETTER 06-91. MAKE REPAIRS TO SATISFACTION OF SURVEY SOCIETY AT NEXT DDBUT NLT 01NOV91.
Condition: Unknown
Due 8 January 1992
Resolved 8 January 1992
Deck/Cargo
Issued 30 April 1991 Resolved
ULLAGE OPENING BUT NOT FITTED WITH FLAME SCREENS. 46CFR32.55-45._x001C_ KEEP ULLAGE CLOSED OR CONSTRUCT FLAME SCREENS PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 15 November 1991
Resolved 15 November 1991
Deck/Cargo
Issued 30 April 1991 Resolved
3 TEMPORY PATCHES ON DECK WATER SEAL FOR IGS. 46CFR32.53. _x001C_ MAKE PERMANENT REPAIRS TO SEAL AT NEXT DRY DOCK BUT NLT 01NOV91.
Condition: Unknown
Due 15 November 1991
Resolved 15 November 1991
Documentation
Issued 5 December 1987 Resolved
VESSEL COULD NOT PRODUCE A RECORD OF A PROPER STATIC LIQUID PRESSURE TEST OF THE CARGO PIPING CONDUCTED WITHIN THE PAST YEAR.
Condition: Unknown
Due 5 December 1987
Resolved 5 December 1987
Deck/Cargo
Issued 5 December 1987 Resolved
OIL CONTENT METER FOR APPROVED MONITORING AND CONTROL SYSTEM IS INOPERATIVE(33 CFR 157.12) - REPAIR AND DEMONSTRATE PROPER UNDERSTANDING OF SYSTEM PRIOR TO NEXT U.S. PORT OF CALL.
Condition: Unknown
Due 5 December 1987
Resolved 5 December 1987
Deck/Cargo
Issued 20 September 1986 Resolved
FLAME SCREENS FOR ALL CARGO TANK VENTS IE 1 THRU 7 PORT,STARBOARD AND CENTER TANKS ARE NOT ADEQUATE.
Condition: Unknown
Due 20 September 1986
Resolved 20 September 1986
Unknown
Issued 20 September 1986 Resolved
DEBRI IN PUMPROOM IE PAINT CANS AND RELATED GEAR NEEDS TO BE REMOVED
Condition: Unknown
Due 20 September 1986
Resolved 20 September 1986
Fire Fighting
Issued 25 June 1985 Resolved
VESSEL DID NOT HAVE ONBOARD A FIRE CONTROL PLAN OR THE DUPLICATE SET AS REQUIRED BY SOLAS 74; REGULATION 20 1981 AMENDMENT, SOLAS 74; CHAPTER II-2 REGULATION 20 AMENDMENT 1984.
Condition: Unknown
Due 25 June 1985
Resolved 25 June 1985
Documentation
Issued 25 June 1985 Resolved
VESSEL DID NOT HAVE ONBOARD A COMPLETE OIL TRANSFER PROCEDURES AS REQUIRED BY 33 CFR 155.750(A)(1)(II). IN THAT THE CARGO INFORMATION WAS MISSING.
Condition: Unknown
Due 25 June 1985
Resolved 25 June 1985
Deck/Cargo
Issued 25 June 1985 Resolved
REPAIR PRESSURE/VACUUM VALVE ON #1 CENTER CARGO TANK
Condition: Unknown
Due 25 June 1985
Resolved 25 June 1985
Deck/Cargo
Issued 25 June 1985 Resolved
RENEW AS NEEDED, FLAME SCREENS ON VARIOUS VENTS FWD OF DECK HOUSE ON MAIN DECK PORT AND STBD.
Condition: Unknown
Due 25 June 1985
Resolved 25 June 1985
Deck/Cargo
Issued 25 June 1985 Resolved
REPLACE FLAME SCREENS FOR HEAVY OIL TANK VENT PORT SIDE BOAT DECK.
Condition: Unknown
Due 25 June 1985
Resolved 25 June 1985
Documentation
Issued 25 June 1985 Resolved
VESSEL DID NOT HAVE ONBOARD AN OIL RECORD BOOK FOR MACHINERY SPACES AS REQUIRED BY 33 CFR 151.25.
Condition: Unknown
Due 25 June 1985
Resolved 25 June 1985
Unknown
Issued 25 June 1985 Resolved
REMOVE OIL FROM DECKS IN EMERGENCY FIRE PUMP ROOM AND STEERING GEAR ROOM.
Condition: Unknown
Due 25 June 1985
Resolved 25 June 1985

Ownership record