MAURY USCG vessel records Sign in
← All vessels

ENALIOS ETHRA

ENALIOS ETHRA is a 1981 tank ship. The Coast Guard has recorded 43 inspections since 1984, most recently in January 1998, along with 21 deficiencies and 2 operational controls.

Records from 1984 to 1998. Most recent: inspection, 18 January 1998.

Built
1981
Last inspected
18 January 1998
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7931662 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228132
Flag
NORWAY
—
Maury page id
psix-228132

Inspections, by type

…with no type recorded32
Years with a record 13 calendar years (1984–1998)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it41390 - Regulatory (Subpart C or D), Gross Ton
85592 - Dead Weight, Ton
29642 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 43

18 January 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 411951
17 December 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 410973
17 December 1997 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 782186
26 November 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 410499
27 September 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 410794
19 September 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 407944
24 January 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 386897
4 August 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 139411
24 March 1995 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 16484
24 March 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 177321
27 February 1995 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 200299
27 February 1995 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 753273
6 December 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 522261
10 November 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 371997
9 October 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1174339
9 October 1994 Tank Vessel Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1416031
20 July 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 359512
20 July 1993 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 845414
12 June 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 359073
9 May 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 36630
9 May 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 472100
13 July 1992 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1266144
5 February 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 348608
13 January 1992 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 520850
31 October 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1248986
24 September 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1309719
22 August 1991 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 345501
22 August 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1253742
14 July 1991 Deficiency Check · Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 938396
11 July 1991 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 344774
11 July 1991 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 936192
4 May 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 521783
19 November 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 340310
26 July 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 338457
9 May 1990 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 460289
10 January 1990 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 904498
12 August 1989 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 332030
12 August 1989 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1039181
30 July 1986 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 513239
13 February 1986 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 306906
29 June 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 481582
13 December 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 299313
19 May 1984 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 296363

Deficiency record · 21

Accommodation/Occupational Safety
Issued 17 December 1997 Resolved
CROP AND RENEW STEP ON LADDER STARBOARD SIDE FOREPEAK.
Condition: Unknown
Due 17 January 1998
Resolved 9 January 1998
Lifesaving
Issued 17 December 1997 Resolved
ELECTRICAL WIRING UNDER CATWALK AGED.
Condition: Unknown
Due 17 January 1998
Resolved 9 January 1998
Engineering
Issued 17 December 1997 Resolved
STEAM VALVES FOR MAIN BOOM LEAKING.
Condition: Unknown
Due 17 January 1998
Resolved 9 January 1998
Deck/Cargo
Issued 17 December 1997 Resolved
STEAM CHECK VALVE AND GATE VALVE WHICH OPERATE THE LOADING ARM HOLED AND LEAKING BADLY. BOTH NEED REPLACING.
Condition: Unknown
Due 17 December 1997
Resolved 17 December 1997
Unknown
Issued 17 December 1997 Resolved
CROP AND REPLACE STEP ON THE STARBOARD SIDE LADDER ON THE FOREPEAK.
Condition: Unknown
Due 17 December 1997
Resolved 17 December 1997
Electrical
Issued 17 December 1997 Resolved
ELECTRICAL WIRING RUNNING BENEATH THE CAT WALK, AMIDSHIPS, HAD WORN THROUGHTHE ARMORED CABLE. MUST REPLACE WITH NEW WIRE. WIRE IS FOR DECK LIGHTING.
Condition: Unknown
Due 17 December 1997
Resolved 17 December 1997
Engineering
Issued 26 November 1997 Resolved
LOOSE CONNECTION TO MAIN ENGINE STARTING CIRCUIT GOVERNOR.
Condition: Unknown
Due 26 November 1997
Resolved 4 December 1997
Navigation
Issued 19 September 1997 Resolved
The bridge rudder angle indicator was off by 7 degrees from the position ofthe rudder (when the bridge read 25 degrees port, the rudder post was actually 32 degress port). SOLAS 74 Chap II-1 Reg. 29.
Condition: Unknown
Due 25 September 1997
Resolved 30 September 1997
Navigation
Issued 19 September 1997 Resolved
The echo depth sounder recorder is inoperative. 33CFR164.35(i).
Condition: Unknown
Due 1 October 1997
Resolved 9 October 1997
Navigation
Issued 20 July 1993 Resolved
A VIO OF 33 CFR 164.30 IN THAT THE MANEUVERING FACT SHEET REQ. BY 33 CFR 164.35(g) WAS INCOMPLETE IN THAT IT DID NOT CONTAIN FOR NORMAL BALLAST CONDITION FOR TURNING CIRCLE AND TIME AND DISTANCE TO STOP.
Condition: Unknown
Due 11 March 1995
Resolved 11 March 1995
Deck/Cargo
Issued 20 July 1993 Resolved
PRIOR TO RETURNING TO U. S. WATERS, PROVIDE LOCAL OCMI WITH COPY OF CLASS REPORT STATING DISCHARGE MONITOR HAS BEEN PROPERLY REPAIRED.
Condition: Unknown
Due 20 July 1993
Resolved 20 July 1993
Construction/Loadline
Issued 22 August 1991 Resolved
INSTALL COMPATIABLE SPEED LOG TO DISCHARGE MONITOR AND CONTROL SYSTEM TO ENABLE DISCHARGE MONITOR TO CALCULATE SPEED TRAVELED WHEN SYSTEM IS IN OPERATION.
Condition: Unknown
Due 22 August 1991
Resolved 22 August 1991
Deck/Cargo
Issued 14 July 1991 Resolved
OPEN, INSPECT, AND REWORK AS NECESSARY #3 PORT CARGO TANK P/V WHICH WAS LOCATION OF FIRE RESULTING FROM LIGHTNING STRIKE.
Condition: Unknown
Due 14 July 1991
Resolved 14 July 1991
Deck/Cargo
Issued 11 July 1991 Resolved
REPAIR THE IGS GAS REGULATOR (VISUAL ALARM) INDICATOR.
Condition: Unknown
Due 11 July 1991
Resolved 11 July 1991
Lifesaving
Issued 11 July 1991 Resolved
DETERMINE THE SOURCE OF THE EXHAUST LEAK FROM THE EMERGENCY FIRE PUMP AND MAKE PERMANENT REPAIRS PRIOR TO THE NEXT U.S. PORT.
Condition: Unknown
Due 11 July 1991
Resolved 11 July 1991
Navigation
Issued 11 July 1991 Resolved
REPAIR AND PROVE OPERATION OF THE DEVICE TO INDICATE SPEED AND DISTANCE (SPEED LOG).
Condition: Unknown
Due 11 July 1991
Resolved 11 July 1991
Construction/Loadline
Issued 11 July 1991 Resolved
PROVE PROPER OPERATION OF THE OIL DISCHARGE MONITOR AND CONTROL SYSTEM.
Condition: Unknown
Due 11 July 1991
Resolved 11 July 1991
Accommodation/Occupational Safety
Issued 11 July 1991 Resolved
MAKE OPERABLE THE CARGO PUMPROOM AIR SUPPLY VENTILATOR IN WAY OF THE BALLAST PUMP.
Condition: Unknown
Due 11 July 1991
Resolved 11 July 1991
Deck/Cargo
Issued 11 July 1991 Resolved
REPAIR THE INERT GAS SYSTEM'S OXYGEN AND PRESSURE RECORDERS.
Condition: Unknown
Due 11 July 1991
Resolved 11 July 1991
Deck/Cargo
Issued 11 July 1991 Resolved
REWORK THE P/V VALVES ON NUMBERS 2 AND 3 CARGO TANKS.
Condition: Unknown
Due 11 July 1991
Resolved 11 July 1991
Accommodation/Occupational Safety
Issued 26 July 1990 Resolved
VESSEL WAS EQUIPPED WITH WITH FIXED WITH FIXED TOILETS BUT HAD NO _x001C_ CERTIFICATION OR APPROVED LABEL FOR TYPE II HOLDING TANKS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 July 1990
Resolved 26 July 1990

Ownership record