Records from 1984 to 2004. Most recent: inspection, 23 July 2004.
Inspection history · 29
23 July 2004
ISPS II Exam · NPV Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2134536
18 July 2004
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2140903
30 June 2004
PII Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2116203
2 May 2004
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2055341
26 April 2004
Ballast Water Examination · Annual Inspection · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2052948
31 July 2003
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1862538
15 June 2003
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1817739
14 June 2003
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1818713
11 June 2003
Type not recorded
No type recorded · USCGC VIGOROUS (WMEC 627) · Activity 1822442
22 April 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1778619
7 April 2003
PII Safety Exam
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1769456
2 August 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 431250
21 February 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 425576
28 August 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 419850
14 August 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 419754
12 August 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 68994
24 July 1998
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 418181
21 August 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 406946
3 February 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 400036
23 July 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 393464
19 April 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 704423
11 April 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 389818
6 December 1995
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 385754
1 December 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 385569
30 January 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 374671
1 August 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 369041
1 August 1994
Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 863008
30 July 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2229
7 May 1984
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 296317
Navigation › Piloting/Steering › Gyro Compass
Issued 23 July 2004
Resolved
Provide proof of proper operation of the gyrocompass. 33CFR164.35
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2004
Resolution: Vessel provided a copy of the repair order verifying that proper repairs were made and the gyrocompass is in compliance with 33CFR164.35.
Construction/Loadline › Structures › Deck Plating
Issued 23 July 2004
No resolution recorded
Repair to the satisfaction of class the fractures and wastage on the bulwark and hatch coaming support structures. The majority of these were found near cargo hatches 3 and 4. ICLL 66 I/1.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Construction/Loadline › Structures › Deck Plating
Issued 23 July 2004
No resolution recorded
Repair engine room deck plating and engine control room flooring to the satisfaction of Coast Guard inspector. ILO 147.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Engineering › Bilge Water Management System › Piping
Issued 23 July 2004
No resolution recorded
Modify bilge piping arrangement to the satisfaction of class so there is no direct connection overboard from sludge tank. Provide class approval of new piping diagram. MARPOL Annex I/17.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Certificates/Documents › IOPP Certificate
Issued 23 July 2004
No resolution recorded
Update IOPP to include the waste oil tank. MARPOL Annex I/17.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 2 May 2004
Resolved
Provide class report specifically addressing and clearing the deficiencies related to activity # 1817739. SOLAS 74 I/11 LEGACY COMPONENT DESC: Company Responsibilities/Authority
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 June 2004
Resolution: RECEIVED CLASS REPORT. NECESSARY REPAIRS MADE.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 26 April 2004
Resolved
Self closing fire door (class A) between incinerator/engine room and passageway does not close/secure adequately (SOLAS 74, Ammended) LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2004
Resolved 30 June 2004
Resolution: RECEIVED CLASS REPORT. NECESSARY REPAIRS MADE.
Construction/Loadline › Structures › Deck Plating
Issued 26 April 2004
Resolved
Deck plate aft of general service fire pump is wasted - ILLC 66 Annex 1/15 LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2004
Resolved 30 June 2004
Resolution: RECEIVED CLASS REPORT. NECESSARY REPAIRS MADE.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 26 April 2004
Resolved
Wastage/Corrosion on Crane house # 1, 2, and 3 - Rivets/Bolts missing, soft patch on machine cover plate on Crane # 1, Excess wastage on Crane house #2, and 3 around windows, gaskets, and combings. LEGACY COMPONENT DESC: Cranes
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2004
Resolved 30 June 2004
Resolution: RECEIVED CLASS REPORT. NECESSARY REPAIRS MADE.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 15 June 2003
Resolved
MSD HOLED/WASTED (FORWARD NEAR BOTTOM). REPAIR/RENEW TO SATISFACTION OF FLAG STATE. (MARPLOL 73/78 ANNEX IV /3.4) LEGACY COMPONENT DESC: Marine Sanitation Device, Type 1
Due 15 July 2003
Resolved 30 June 2004
Resolution: RECEIVED CLASS REPORT. NECESSARY REPAIRS MADE.
Deck/Cargo › Holds/Tanks › Coaming
Issued 15 June 2003
Resolved
HATCH COAMING HOLED/WASTED IN CARGO HOLDS #1, #2, #3. CLASS TO SURVEY ALL HOLDS AND RECOMMEND REPAIRS. (ICLL 66) ******RCVD CLASS REPORT DOUBLERS WELDED ON WASTED AREAS. CONDITION OF CLASS NOW IMPOSED FOR ALL HATCH COAMING TO BE ADDRESSED IN DRYDOCK. LEGACY COMPONENT DESC: Coaming
Due 15 August 2003
Resolved 30 June 2004
Resolution: RCV''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''D CLASS REPORT FROM LR, CERT.#MMI 035058, DATED 16JUN03. DOUBLERS WELDED ON WASTED AREAS (TEMPORARY REPAIR) AND CONDITION OF CLASS NOW IMPOSED, ALL HATCH COAMING TO BE DEALT WITH IN DRYDOC
Fire Fighting › Fire Main › Condition
Issued 15 June 2003
Resolved
FIRE MAIN WASTED/HOLED FORWARD OF HATCH #2 STBD SIDE. MAKE PERMANENT REPAIRS TO SATISFACTION OF CLASS. (SOLAS 74(A)II-2/21)
Action required: 17 - Rectify deficiencies prior to departure
Due 15 June 2003
Resolved 16 June 2003
Resolution: RCV''D LR CLASS REPORT DATED 16JUN03 CERT. #MMI 035058. AREA WAS CROPPED AND RENEWED. LINE PRESSURE TESTED TO 6.8 BAR AND FOUND TIGHT.
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 15 June 2003
Resolved
Conduit pipe on port side missing brackets and multiple brackets wasted. Pipe is actually laying on deck near cargo hold #3. Class to address and recommend repairs (ICLL 66). LEGACY COMPONENT DESC: Conduit Pipe
Due 15 August 2003
Resolved 30 June 2004
Resolution: RECEIVED CLASS REPORT. NECESSARY REPAIRS MADE.
Construction/Loadline › Structures › Superstructure
Issued 15 June 2003
Resolved
The crane house beween hatches #2 and #3 on the aft end, port side, is cracked--area top of hatch coaming down to main deck(soft patch). Class to address and make recommendation of repairs. (ICLL 66) ********Rcvd Class Report -Doubler fitted. Condition of Class now imposed. LEGACY COMPONENT DESC: Crane House
Due 15 August 2003
Resolved 30 June 2004
Resolution: RECEIVED CLASS REPORT. NECESSARY REPAIRS MADE.
Engineering
Issued 14 August 1998
Resolved
CEMENT BOX PATCHES IN ENGINEROOM(8). MAIN ENGINE COOLING LINE, GENERATOR COOLING WATER INLET LINE, A/C LINES, ETC.._x001C_ _x001C_ SOLAS 74 REG I/11_x001C_
Condition: Unknown
Due 21 February 1999
Resolved 21 February 1999
Documentation
Issued 24 July 1998
Resolved
DOCUMENT OF COMPLIANCE DOES NOT HAVE A VALID ENDORSEMENT.
Condition: Unknown
Due 1 August 1998
Resolved 4 August 1998
Lifesaving
Issued 24 July 1998
Resolved
FOOD RATIONS IN THE PORT AND STBD LIFEBOATS NOT ADEQUATE FOR CREW.
Condition: Unknown
Due 1 August 1998
Resolved 4 August 1998
Fire Fighting
Issued 24 July 1998
Resolved
INTERNATIONAL SHORE CONNECTION NOT AVAILABLE FOR IMMEADIATE USE.
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Lifesaving
Issued 24 July 1998
Resolved
LIFE JACKET LIGHTS HAVE EXPIRED BATTERIES.
Condition: Unknown
Due 1 August 1998
Resolved 6 August 1998
Fire Fighting
Issued 24 July 1998
Resolved
FIREMAIN STBD SIDE IN WAY OF HATCH #3 LEAKING AT EXPANSION JOINT. ALSO, FIREMAIN IN THE MAIN MACHINERY SAPCE ON THE BOTTOM FLAT, STBD SIDE, LEAKING.
Condition: Unknown
Due 1 August 1998
Resolved 4 August 1998
Lifesaving
Issued 3 February 1997
Resolved
A VIO OF SOLAS IN THAT THE VESSEL HAD 14 TORN FOOD RATIONS IN THE LIFE BOATS.
Condition: Unknown
Due 4 February 1997
Resolved 4 February 1997
Lifesaving
Issued 23 July 1996
Resolved
PRIOR TO DEPARTURE REPLACE BOTH LIFEBOAT BILGE OVERBOARD HOSE. BOTH HOSES ARE DRY ROTTED.
Condition: Unknown
Due 24 July 1996
Resolved 24 July 1996
Documentation
Issued 23 July 1996
Resolved
VESSEL CHANGED NAME ON 22JUL96. ALL CERTIFICATES WERE UNDER OLD NAME. PRIORTO DEPARTURE HAVE CLASS ISSUE NEW CERTIFICATES.
Condition: Unknown
Due 24 July 1996
Resolved 24 July 1996
Navigation
Issued 23 July 1996
Resolved
VESSEL ENTERED TAMPA BAY WITHOUT CHARTS 11412,11413, AND 11414, OR FOREIGN EQUIVALENT. VESSEL OBTAINED CHARTS UPON DOCKING.
Condition: Unknown
Due 24 July 1996
Resolved 24 July 1996
Navigation
Issued 11 April 1996
Resolved
THE VESSEL'S BRITISH ADMIRALTY CHART 1081 WAS NOT CURRENTLY CORRECTED. THELAST CORRECTION WAS 1995-1135; THE STANDARD AS OF 11APR96 IS 1996-941. THEVESSEL CORRECTED THE CHART PRIOR TO DEPARTURE.
Condition: Unknown
Due 14 April 1996
Resolved 15 April 1996
Lifesaving
Issued 11 April 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 July 1996
Resolved 24 July 1996
Lifesaving
Issued 1 December 1995
Resolved
CURRENTLY UNABLE TO START VESSEL'S STARBOARD SIDE LIFEBOAT MOTOR.
Condition: Unknown
Due 10 December 1995
Resolved 5 December 1995
Navigation
Issued 30 January 1995
Resolved
PROVIDE INLAND NAVIGATION RULES. 33 CFR 88.05. PROVIDE PRIOR TO DEPARTURE.
Condition: Unknown
Due 3 February 1995
Resolved 3 February 1995
Fire Fighting
Issued 30 January 1995
Resolved
PROVIDE SPANNER WRENCHES FOR ALL FIRE STATIONS. SOLAS II-2. PROVIDE PRIORTO NEXT U.S. PORT.
Condition: Unknown
Due 5 December 1995
Resolved 5 December 1995
Accommodation/Occupational Safety
Issued 1 August 1994
Resolved
HOSPITAL SPACE HAD STORES AND BICYCLES STORED IN IT.
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Accommodation/Occupational Safety
Issued 1 August 1994
Resolved
DECK HEAD IN HOSPITAL SPACE WAS NOT WORKING.
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Lifesaving
Issued 1 August 1994
Resolved
EMERGENCY FOOD IN PORT LIFEBOAT WAS EXPIRED.
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995