MAURY USCG vessel records Sign in
← All vessels

FLORENCE STAR

FLORENCE STAR is a 1979 freight ship. The Coast Guard has recorded 12 inspections since 1984, most recently in September 1998, along with 43 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 1984 to 1998. Most recent: operational control imposed, 22 September 1998.

Built
1979
Last inspected
22 September 1998
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7932707 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228147
Flag
CYPRUS
—
Maury page id
psix-228147

Inspections, by type

…with no type recorded12
…past their stated due date1
Years with a record 7 calendar years (1984–1998)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10380 - Regulatory (Subpart C or D), Gross Ton
12665 - Dead Weight, Ton
5708 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 12

22 September 1998 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 420607
2 June 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 404567
29 January 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 399808
10 September 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 395087
13 January 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 313760
18 May 1986 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 507849
16 May 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 484187
26 September 1985 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 304627
24 September 1985 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 304455
12 September 1985 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 304182
13 March 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 470852
27 August 1984 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 297749

Deficiency record · 43

Accommodation/Occupational Safety
Issued 22 September 1998 Resolved
Emergency escape hatch IWO steering gear room inoperative.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Lifesaving
Issued 22 September 1998 Resolved
Numerous compressed gas cylinders not stowed properly.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Electrical
Issued 22 September 1998 Resolved
Numerous bare electrical wires & numerous light bulbs with no guards noted throughout vessel.
Condition: Unknown
Due 24 September 1998
Resolved 25 September 1998
Navigation
Issued 22 September 1998 No resolution recorded
Hydraulic leaks noted from both steering gear pumps. Also excess oil on_x001C_ deck. Parts for repairs not available so Class extended requirment for permanent repairs NLT 22Dec98.
Condition: Unknown
Due 22 December 1998 — due date passed with no resolution recorded
Electrical
Issued 22 September 1998 Resolved
No rubber matting in front of emergency generator switchboard.
Condition: Unknown
Due 24 September 1998
Resolved 25 September 1998
Electrical
Issued 22 September 1998 Resolved
Emergency generator remote fuel shutoff valve inoperative.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Documentation
Issued 22 September 1998 Resolved
Vsl's SOPEP noted onboard is not yet approved by class or flag state._x001C_
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Navigation
Issued 22 September 1998 Resolved
Vsl's gyrocompass malfunctioned while at anchorage. Ltr of Deviation issued to vsl to enter port.
Condition: Unknown
Due 24 September 1998
Resolved 25 September 1998
Lifesaving
Issued 22 September 1998 Resolved
Numerous amounts of oil & fuel noted in engineroom.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Engineering
Issued 22 September 1998 Resolved
Vessel recently had new OWS installed. Class to attest to operation &_x001C_ renew/amend IOPP certificate as necessary.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Documentation
Issued 22 September 1998 Resolved
Vessel's oil transfer procedures were not complete. Vsl was to bunker but_x001C_operations held up until discrepancy corrected.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Navigation
Issued 22 September 1998 Resolved
Vsl had no current Rules of the Road.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Documentation
Issued 22 September 1998 Resolved
No crewmembers onboard have proof of having HAZMAT training.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Lifesaving
Issued 22 September 1998 Resolved
All lifejackets onboard noted have tape which is no longer retroreflective.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Construction/Loadline
Issued 29 January 1997 Resolved
Repair or replace inoperative dogs on main deck water-tight doors. Approx 90% of doors inspected had a minimum of one dog that was frozen.
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Documentation
Issued 10 September 1996 Resolved
Pre-arrival test not logged IAW 33 CFR 164.25(d), correct prior to next U.S. port.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Navigation
Issued 10 September 1996 Resolved
#1 (port) radar inoperable IAW SOLAS 74 V/12(h). Spare parts are not available for unit. Correct prior to next U.S. port. Granted deviation todepart HOUMS. #2 (stbd) radar operating properly.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Documentation
Issued 10 September 1996 Resolved
No OTP posted IAW 33 CFR 155.720
Condition: Unknown
Due 13 September 1996
Resolved 16 September 1996
Accommodation/Occupational Safety
Issued 10 September 1996 Resolved
Sewage system, inoperable pump IAW 33 CFR 159.7
Condition: Unknown
Due 13 September 1996
Resolved 3 October 1996
Electrical
Issued 10 September 1996 Resolved
Repairs being done on main generators
Condition: Unknown
Due 13 September 1996
Resolved 3 October 1996
Construction/Loadline
Issued 10 September 1996 Resolved
Excessive oil in main machinery space (bilges, deck and equip.) IAW 33 CFR160.113
Condition: Unknown
Due 13 September 1996
Resolved 3 October 1996
Electrical
Issued 10 September 1996 Resolved
Low RPMs on EGen, rated 380c/50v IAW SOLAS 60 I/10
Condition: Unknown
Due 9 October 1996
Resolved 3 October 1996
Lifesaving
Issued 10 September 1996 Resolved
Remove all flammable liquids from BOSN stores IAW SOLAS 60 II/45
Condition: Unknown
Due 13 September 1996
Resolved 16 September 1996
Fire Fighting
Issued 10 September 1996 Resolved
Replace fire hoses at FS 1, 2 and throughout engine room IAW SOLAS 60 II/65(c)
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Documentation
Issued 10 September 1996 Resolved
Unable to locate oil record book onboard IAW MARPOL 73/78 Annex I/20
Condition: Unknown
Due 10 September 1996
Resolved 11 September 1996
Accommodation/Occupational Safety
Issued 10 September 1996 Resolved
Remove debrie and repair lighting in engine room Emergency Escape hatch/space IAW SOLAS 60 II/68(a)(ii)
Condition: Unknown
Due 13 September 1996
Resolved 16 September 1996
Engineering
Issued 10 September 1996 Resolved
OWS pump and alarms inoperable IAW MARPOL 73/78 Annex I/9(b)
Condition: Unknown
Due 9 October 1996
Resolved 3 October 1996
Lifesaving
Issued 10 September 1996 Resolved
Clogged fuel line on portside lifeboat IAW SOLAS 60 III/9(a)(i)
Condition: Unknown
Due 13 September 1996
Resolved 3 October 1996
Electrical
Issued 10 September 1996 Resolved
On deck lighting throughout in need of repair/replacement and mounted properly IAW SOLAS 60 II/27
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Documentation
Issued 10 September 1996 Resolved
SOPEP missing emergency phone numbers IAW MARPOL 73/78 Annex I/26.2(b)
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Navigation
Issued 10 September 1996 Resolved
Missing Nav rules and light lists IAW 33 CFR 164.33(a)
Condition: Unknown
Due 9 October 1996
Resolved 16 September 1996
Engineering
Issued 10 September 1996 Resolved
Repairs being done on main diesel engine
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Construction/Loadline
Issued 10 September 1996 Resolved
Fwd battery room on portside bridge, WTD is deteriorated, holed and does not close
Condition: Unknown
Due 13 September 1996
Resolved 16 September 1996
Lifesaving
Issued 10 September 1996 Resolved
Hydrostatic release on portside life raft requires servicing IAW SOLAS 74 III/19.9.1
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Electrical
Issued 10 September 1996 Resolved
Interior lighting in engineer spaces in need of repair/replacement IAW SOALS 60 II/27
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Documentation
Issued 13 January 1987 Resolved
VESSEL OIL TRANSFER PROCEDURES WAS INCOMPLETE A VIOLATION OF 33 CFR 155.750
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Navigation
Issued 26 September 1985 Resolved
CHARTS 12333,12334,AND 12349 WERE NOT ONBOARD AS REQUIRED BY 33 CFR 164.33.NO FOREIGN EQUIVALENT CHARTS ARE ACCEPTED FOR 12334 AND 12349. BRITISH ADM-IRALTY CHARTS 2755 AND 3204 WERE ON BOARD,BUT NEITHER CHART COVERS 12333.
Condition: Unknown
Due 26 September 1985
Resolved 26 September 1985
Navigation
Issued 24 September 1985 Resolved
VIOLATION OF 33 CFR 164.33 FOR OPERATING A VSL OF 1,600 OR MORE GROSS TONS WITHOUT A CURRENTLY CORRECTED COPY OF, OR APPLICABLE CURRENTLY CORRECTED EXTRACT FROM, THE U.S. COAST PILOT (VOL.3) FOR THE AREA TO BE TRANSITED (C&D CANAL TO BALTIMORE), AS REQUIRED BY 33 CFR 164.33 (A)(2)(I).
Condition: Unknown
Due 24 September 1985
Resolved 24 September 1985
Navigation
Issued 12 September 1985 Resolved
THE VSL DID NOT HAVE A BLOCK DIAGRAM OF STEERING GEAR WITH CHANGE OVER INSTRUCTIONS AS REQUIRED BY: 33 CFR 164.35(K).
Condition: Unknown
Due 12 September 1985
Resolved 12 September 1985
Documentation
Issued 12 September 1985 Resolved
THE CONTENTS OF VESSELS OIL TRANSFER PROCEDURES WERE NOT COMPLETE AS IS REQUIRED BY: 33 CFR 155.720. USC CITE= 33 USC 1321(J)(1)(C).
Condition: Unknown
Due 12 September 1985
Resolved 12 September 1985
Documentation
Issued 12 September 1985 Resolved
VSL DID NOT HAVE A MARPOL 73/78 ORB. HOWEVER, ENTRIES WERE RECORDED AS REQUIRED BY: 33 CFR 151.25. VSL WAS SUPPLIED WITH A MARPOL ORB. USC CITE= 33 USC 1321(J)(1)(C).
Condition: Unknown
Due 12 September 1985
Resolved 12 September 1985
Documentation
Issued 12 September 1985 Resolved
THE VESSEL DID NOT HAVE A POLLUTION PLACARD FIXED IN A CONSPICOUS PLACE AS REQUIRED BY: 33 CFR 155.450(A). USC CITE= 33 USC 1321(J)(1)(C).
Condition: Unknown
Due 12 September 1985
Resolved 12 September 1985
Navigation
Issued 27 August 1984 Resolved
NOS CHARTS 18720 AND 18751 WERE UNCORRECTED. BRITISH ADM. COAST PILOT VOL.8WAS CORRECTED TO SUPPLEMENT #2.
Condition: Unknown
Due 27 August 1984
Resolved 27 August 1984

Ownership record