MAURY USCG vessel records
← All vessels

AYUBIA

AYUBIA is a 1981 tank barge. The Coast Guard has recorded 26 inspections since 1988, most recently in March 1997, along with 24 deficiencies.

Records from 1988 to 1997. Most recent: inspection, 8 March 1997.

Built
1981
Last inspected
8 March 1997
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the tow units and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 8 March 1997
…with no type recorded26
Operational controls None recorded without a removal date
Years with a record 8 calendar years (1988–1997)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8000185
228158
Flag
PAKISTAN
Maury page id
psix-228158

Documentation record

Tonnage as PSIX records it7179 - Regulatory (Subpart C or D), Net Ton
18050 - Dead Weight, Ton
23680 - Displacement, Ton
11940 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

26 inspections, each with its date, unit and type; 24 deficiencies with the resolution recorded against each; 1 vessel inspected with it, by name and date; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

T-2306B Freight Barge · MISLE 149222 · 4 February 1995 · activity 180576

Inspection history · 26

8 March 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 401057
18 February 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 400180
25 June 1996 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 392429
15 February 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 387847
16 January 1996 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 386676
9 August 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 191486
9 August 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 765714
9 July 1995 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 380352
11 June 1995 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 391982
27 February 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 375705
4 February 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 180576
2 February 1995 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 645584
20 January 1995 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 374287
21 September 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 370667
3 September 1994 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 539103
29 April 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 366446
19 April 1994 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 645581
9 April 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 506435
7 August 1993 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 360142
6 July 1993 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 359247
9 April 1991 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 342947
6 September 1989 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 528235
23 August 1989 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 332185
20 April 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 329824
29 March 1989 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 329098
5 July 1988 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 324338

Deficiency record · 24

Lifesaving
Issued 18 February 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Lifesaving
Issued 18 February 1997 Resolved
SOLAS III/41.9: BOTH PORT & STBD LIFE BOATS MISSING REFLECTIVE TAPE ON HULL BOTTOMS; DIMENTIONS (LxBxD) & PERSON CAPACITY ON HULLS, ALSO NAME OR CALL SIGN FOR IDENTIFICATION FROM ABOVE INSIDE BOATS. CORRECT NOT LATER THAN 19MAR97.
Condition: Unknown
Due 19 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 18 February 1997 Resolved
SOLAS III/30.2: RING BUOY WATER LIGHT, MAIN DECK ON STERN INOP. CORRECTED ON THE SPOT.
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Electrical
Issued 18 February 1997 Resolved
SOLAS II-1/45.10.2: LIGHT FIXTURES IN BOTH WORKING & STORAGE PAINT LOCKERS NOT EXPLOSION PROOF TYPE. LOCATION; PORT SIDE OF MAST HOUSE BETWEEN CARGO HOLDS 2 & 3. CORRECT WITH PROPER FIXTURES NOT LATER THAN 19MAR97.
Condition: Unknown
Due 19 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 18 February 1997 Resolved
SOLAS II-2/17.1.4: PORTABLE LIGHT FOR FOREWARD FIREMANS OUTFIT IN DECK STORES UNDER FOS'SLE DECK MISSING. CORRECTED ON THE SPOT.
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Engineering
Issued 18 February 1997 Resolved
SOLAS II-1/26.1: SECURE STEAM SERVICE OUTLET ABOVE OILY WATER SEPERATOR WITH PROPER BLANK OR PLUG. CORRECT NOT LATER THAN 19MAR97.
Condition: Unknown
Due 19 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 18 February 1997 Resolved
SOLAS II-1/26.3.1: COOLING MANIFOLD TO NO. 2 SHIPS SERVICE GENERATOR HAS PIN HOLES AND LEAKING PROFUSELY. CORRECT NOT LATER THAN 19MAR97.
Condition: Unknown
Due 19 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 18 February 1997 Resolved
SOLAS II-2/20.1: FIRE CONTROL PLANS HAVE SYMBOL FOR INTERNATIONAL SHORE CONECTION ON KEY BUT NOT WHERE LOCATION IS ON VESSEL. ENSURE ALL FIRE CONTROL PLANS HAVE SHIPBOARD LOCATION OF INTERNATIONAL SHORE CONECTION NOT LATER THAN 19MAR97.
Condition: Unknown
Due 19 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 18 February 1997 Resolved
SOLAS II-1/45.1.3: LIGHT FIXTURES IN DECK STORES UNDER FOC'SLE DECK & MAIN DECK LIVING QUARTERS INSIDE SUPERSTRUCTURE MISSING PROTECTIVE COVERS. CORRECT NOT LATER THAN 19MAR97.
Condition: Unknown
Due 19 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 18 February 1997 Resolved
TIDE AND CURRENT TABLES FOR EAST COAST OF NORTH AMERICA. NOT ONBOARD. NO FOREIGN EQUIVALENT. PROVIDED BY LOCAL AGENT PRIOR TO DEPARTURE, ORDER FOR PUBS WAS MADE BEFORE ARRIVIAL AT BALMS.
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Construction/Loadline
Issued 18 February 1997 Resolved
EXCESSIVE OIL RESIDUE IN BILGE. CORRECT NOT LATER THAN 19MAR97.
Condition: Unknown
Due 19 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 18 February 1997 Resolved
SOLAS II-1/26.8: NO. 1 CYLINDER LUBE OIL GLAND; UPPER CRANK CASE, LEAKING PROFUSELY. CORRECT NOT LATER THAN 19MAR97.
Condition: Unknown
Due 19 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 18 February 1997 Resolved
SOLAS II-1/45.1.3: LIGHTING FIXTURES IN ENGINE ROOM MISSING PROTECTIVE COVERS. CORRECT NOT LATER THAN 19MAR97.
Condition: Unknown
Due 19 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 16 January 1996 Resolved
ALL WATER DRAINAGE PIPING IN VESSEL'S HOSPITAL SPACE FOR TOILET, SINK, AND_x001C_TUB CLOGGED. SPACE TO BE CLEANED TO ILO-147 STANDARDS WITH PROPER RUNNING_x001C_ WATER PROVIDED.
Condition: Unknown
Due 16 February 1996
Resolved 16 February 1996
Fire Fighting
Issued 27 February 1995 Resolved
MAKE PERMANENT PEPAIR TO THE HOLE IN THE MAIN FIREFIGHTING LINE (PORT SIDE AT THE #4 CARGO HOLD) PRIOR TO THE NEXT U.S. PORT.
Condition: Unknown
Due 14 August 1995
Resolved 14 August 1995
Electrical
Issued 27 February 1995 Resolved
RENEW THE SOLENOID ON THE EMERGENCY GENERATOR AND MAKE THE AUTOMATIC START OPERABLE PRIOR TO THE NEXT U.S. PORT.
Condition: Unknown
Due 14 August 1995
Resolved 14 August 1995
Accommodation/Occupational Safety
Issued 20 January 1995 Resolved
VIOLATION OF 33 C.F.R. 151.63 VSL DISCHARGING PLACTIC INTO OCEAN.
Condition: Unknown
Due 1 March 1995
Resolved 1 March 1995
Lifesaving
Issued 21 September 1994 Resolved
VESSELS BUOYANT LIFEBUOYS ON BRIDGEWING FOR MARKER LIGHT AND MARKER SMOKE_x001C_ IMPROPER SOLAS WEIGHT. LESS THAN 4 KGs._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Navigation
Issued 9 April 1991 Resolved
33 CFR 164.33(A)(1) VESSEL DID NOT HAVE CHART 13309 ON BOARD FOR THE SEARSPORT MAINE AREA._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Navigation
Issued 20 April 1989 Resolved
A VIO OF 33 CFR 164.30 IN THAT THE MANEUVERING INFO FACT SHEET REQ. BY 33 CFR 164.35(G) WAS INCOMPLETE IN THAT IT DID NOT CONTAIN FOR NORMAL LOAD ANDBALLAST CONDITIONS: TIME AND DISTANCE TO STOP THE VSL FROM HALF SPEEDS.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Documentation
Issued 29 March 1989 Resolved
VESSEL DID NOT HAVE ONBOARD A OIL DISCHARGE PLACARD REQ BY 33CFR155.450
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Documentation
Issued 29 March 1989 Resolved
VESSEL WAS TRANSPORTING THE HARZARDOUS MATERIAL "LINDANE" WITH A DANGEROUS CARGO MANIFEST AS REQ 49CFR176.24
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Navigation
Issued 29 March 1989 Resolved
VESSEL'S MANEUVERING FACT SHEET DID NOT HAVE TIME AND DISTANCE TO STOP FROMHALF SPEED AS REQ BY 33CFR164.35(G)(2)
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Documentation
Issued 29 March 1989 Resolved
VESSEL'S OIL TRANSFER PROCEDURES REQ BY 33CFR155.750 DID NOT CONTAIN A LISTOF PRODUCTS TRANSFERED, NUMBER OF PERSONS REQUIRED, DUTIES BY TITLE FOR EACH PERSON, PROCEDURES FOR TENDING MOORING LINES, REPORTING SPILLS, AND TOPPING OFF TANKS.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.