MAURY USCG vessel records Sign in
← All vessels

GRUS

GRUS is a 1981 freight ship. The Coast Guard has recorded 73 inspections since 1984, most recently in January 2009, along with 23 deficiencies — 1 with no resolution recorded — and 8 operational controls.

Records from 1984 to 2009. Most recent: inspection, 1 January 2009.

Built
1981
Last inspected
1 January 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8000458 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228166
Flag
UNITED KINGDOM
—
Maury page id
psix-228166

Inspections, by type

…with no type recorded48
Years with a record 24 calendar years (1984–2009)
The 73 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it45544 - Convention (Subpart B), Gross Ton
45544 - Regulatory (Subpart C or D), Gross Ton
14159 - Dead Weight, Ton
27069 - Displacement, Ton
13664 - Convention (Subpart B), Net Ton
13644 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 73

1 January 2009 MARPOL Annex V Examination · PI Safety Exam · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3384614
28 November 2008 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3370453
28 October 2008 MARPOL Annex V Examination · ISPS III Exam · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3352684
25 October 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3351318
25 April 2008 MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · ISPS III Exam · PI Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3189773
22 April 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3189728
5 March 2008 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3158875
10 February 2008 Deficiency Check · Administrative Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3144979
6 February 2008 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3142921
5 February 2008 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3141988
9 June 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2956395
5 June 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2952309
11 September 2006 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2775562
14 August 2006 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2747692
5 July 2006 MARPOL Annex I Examination · Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2702078
19 April 2006 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2628700
1 September 2005 NPV Safety Exam · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2478275
7 May 2005 ISPS III Exam · MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2348125
11 February 2005 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2290632
16 November 2004 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2242051
4 November 2004 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2235534
9 September 2004 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2191725
16 June 2004 Security Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2101662
18 January 2004 Re-Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1987590
17 January 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1987356
30 July 2003 Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 1861544
28 July 2003 MARPOL Annex I Examination · Annual Inspection · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1859515
17 July 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1849421
19 March 2003 Ballast Water Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1759686
18 March 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1758952
18 March 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1759335
18 December 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1720352
17 December 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1720068
16 December 2002 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1720241
26 August 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1666358
20 July 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1730925
20 July 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1730932
19 July 2002 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1654273
18 July 2002 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1643608
18 July 2002 Type not recorded
No type recorded · GROUP LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1648609
5 July 2002 Security Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1641667
1 July 2002 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1664217
22 March 2002 Security Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1496129
22 March 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1721578
21 March 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1721598
4 November 2001 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 295120
4 August 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 292427
13 October 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 285745
8 October 1999 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 477832
7 October 1999 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 433440
22 May 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 416248
25 March 1997 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 401850
22 March 1997 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 513100
11 April 1994 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 365849
16 October 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 361703
14 October 1993 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 361536
6 February 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 356159
27 July 1992 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 352115
14 February 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 448703
10 August 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 523268
20 September 1990 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 339395
7 December 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 536186
23 May 1989 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 330450
31 October 1988 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 468312
11 August 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 325017
12 April 1988 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 322620
26 October 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 521523
25 April 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 315705
20 April 1987 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 478114
5 October 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 491493
2 April 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 307899
12 April 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 477484
3 August 1984 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 297240

Deficiency record · 23

Electrical › Lighting (service) › Lighting Fixture
Issued 1 January 2009 Resolved
Three deck lights secured by rope creating a potential electrical hazard. Wiring shall be supported in such a manner as to avoid chafing or other injury.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 January 2009
Resolution: Temporary supported three deck lights were mounted on the permanent secured socket and those were found satisfactory.
Fire Fighting › Fire Main › Condition
Issued 1 January 2009 Resolved
Observed approximate 1" hole in Fire main located on forward upper deck. In this condition it is possible to degrade fire suppression to the forward upper deck area. Water service pipes shall be sufficient for the effective distribution of the maximum required discharge.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 January 2009
Resolution: The holed fire main was repaired by crop and renew with 60cm length. After the repair work, the repaired fire main was tested under the operation pressure with the attending surveyor''''s satisfaction.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 1 January 2009 No resolution recorded
Crew unable to demonstrate proper operation of ships incinerator. Hi/low voltage alarm was required to be by passed by means of a jumper wire to operate to incinerator. In this condition the hi lo voltage alarm required is inoperable.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Construction/Loadline › Hull › Hull Plating
Issued 28 October 2008 Resolved
HULL INDENT, STARBOARD SIDE ABOVE WATERLINE IN VICINITY OF FRAMES 18-22
Action required: 705 - Other - as specified
Due 28 November 2008
Resolved 28 November 2008
Resolution: Received Class NK Survey report with condition of class imposed to have the hull permanently repaired by next dry docking or before 14 Jul 2010.
Engineering › Steering Gear System › Motor
Issued 28 October 2008 Resolved
1-3 DEGGRE DISCREPANCY BEWEEN RUDDER ANGLE INDICATORS ON STEERING GEAR (AT RAM), STEERING GEAR (ABOVE TELEMOTOR) & BRIDGE ADDITIONALLY. DURING TEST OF #1 PUMP, RUDDER WAS "HUNTING" (MOVING BACK AND FORTH) AT BEGINGING OF TEST. AS TEST PROGRESSED HUNTING STOPPED. ATTEST TO PROPER OP OF STERING GEAR AND RUDDER INDICATORS.
Action required: 705 - Other - as specified
Due 28 November 2008
Resolved 28 November 2008
Resolution: Received Class NK Survey Report attesting to proper repairs of the steering gear and associated equipment.
Navigation › Collision/Grounding Avoidance › Radar
Issued 10 February 2008 Resolved
M/V GRUS requested to continue inbound transit to Vancouver berth 10 despite having only one operational radar. A Letter of Deviation was issued allowing continued inbound transit. The Letter of Deviation requires that permanent repairs are made prior to vessel's departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Resolution: repairs made
Fire Fighting › Combustible Materials › Linings
Issued 8 February 2008 Resolved
APPROXIMATELY 10 OPEN CONTAINERS, CATCHING OIL LEAKING FROM VARIOUS EQUIPMENT/ENGINES ARE FILLED WITH OIL THROUGHOUT THE ENGINE ROOM POSING A FIRE AND SAFETY RISK TO THE SHIP AND ITS CREW. SOLAS 4004 CH 1 REG11 30A
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2008
Resolution: All open containers to catch oil were removed witht he attending surveyor''s satisfaction.
Fire Fighting › Combustible Materials › Linings
Issued 8 February 2008 Resolved
EXCESSIVE AMOUNTS OF OIL SOAKED RAGS FOUND IN VARIOUS PLACES THROUGHOUT THE ENGINE ROOM POSING A FARE AND SAFETY RISK TO THE SHIP AND IT'S CREW SOLAS 4004 CH 1 REG11 30A
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2008
Resolution: All oil soaked rags were removed by crew to surveyor''s satisfaction
Fire Fighting › Combustible Materials › Linings
Issued 8 February 2008 Resolved
APPROXAMATELY 1/8 INCH OF OIL IS UNDER THE SHIP SERVICE DIESEL GENERATORS #2 AND #3 AND AN EXCESSIVE AMOUNT OF OIL IS LEAKING DOWN THE SIDES OF GENERATORS #1, #2 AND #3 POSING A FIRE RISK TO THE SHIP AND IT'S CREW SOLAS 4004 CH 1 REG11 30A
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2008
Resolution: No. 1, No.2 and No.3 diesel generator were cleaned up with the attending surveyor''s satisfaction. Oil under the generator engines No.1 and No.2 were removed and cleaned too to class surveyor''s satisfaction.
Fire Fighting › Combustible Materials › Linings
Issued 8 February 2008 Resolved
THE MAIN DIESEL ENGINE WAS COVERED IN OIL AND VARIOUS AREAS THROUGHOUT THE ENGINE ARE COVERED IN AN OILY GRIME POSING AN UNDUE RISK TO THE SHIP AND ITS CREW SOLAS 4004 CH 1 REG11 30A
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2008
Resolution: Oil on the main diesel engien was wiped out and an oily grime at some spot in the engine room was removed or wiped to the attending surveyor''s satisfaction.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 8 February 2008 Resolved
BASED ON THE ABOVE DEFICENCIES THERE ARE CLEAR GROUNDS TO BELIEVE THE MASTER AND CREW ARE UNFAMILIAR WITH PROCEDURES SET FORTH IN THEIR SAFETY MANAGEMENT SYSTEM. SOLAS 2004 CH IX REG 3.1 ISM CODE PART A REG 6.4 30A
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2008
Resolution: After finishing the above cleaning work, the master and chief engineer learned about the fire hazard. The chief engineer explained that he enforced the duty engineers to keep engines, equipment and engine room clean to reduce fire hazard to class satisfa
Engineering › Steam System (main) › Piping
Issued 8 February 2008 Resolved
THERE IS A MINOR STEAM LEAK IN THE SHIPS BOILER POSING A SAFETY RISK TO THE SHIP AND ITS CREW SOLAS CH 1 REG 11 50A
Condition: Damaged By Earlier Event
Due 8 March 2008
Resolved 5 March 2008
Resolution: Received Class report, attesting to Occasional Survey conducted in Japan on 04Mar08. "Abnormal steam leakage was not observed in the machinery space."
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 February 2008 Resolved
WASTED LAGGING FOUND IN VARIOUS AREAS THROUGHOUT THE ENGINE ROOM POSING A SAFETY RISK TO THE SHIP AND ITS CREW
Condition: Improper/Lack of Maintenance
Due 8 March 2008
Resolved 5 March 2008
Resolution: Received Class report attesting to Occasional Survey conducted in Japan on 04Mar08. "Deteriorated lagging in machinery space were adequately cleaned, missing portion supplied and put in order."
Construction/Loadline › Hull › Hull Plating
Issued 5 July 2006 Resolved
On stbd side aft at deck 4 hold3 at frames 62 and 63 there is an inset with both frames buckled inward. Frame 85 on stbd side is cracked. Have class inspect the hull along the stbd side.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 August 2006
Resolution: Received Class report via fax.
Lifesaving › Lifeboat › Watertight Locker/Compartment
Issued 5 July 2006 Resolved
Port lifeboat rations locker hinge is frozen and inoperable. Make permanent repairs to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 August 2006
Resolution: Received Class report via fax.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Block
Issued 5 July 2006 Resolved
Ship service generators rocker valve covers have several hold down nuts missing or not working. Make permanent repairs to satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 August 2006
Resolution: Received Class report via fax.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Distributor (fuel injection)
Issued 5 July 2006 Resolved
Ships service generators #1 & #3 have loose clamp U- bolts on the fuel distribution line at top of engine. Remove the clamps and inspect for wear and install clamps correctly to satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 August 2006
Resolution: Received Class report via fax.
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 May 2005 Resolved
Vessel has various S/W pipes wasted throughout engine room space. Vessel is due to attend yard June 2005 USCG required class report after survey and replacement of pipes listed on yard work. 12MAY05 - Received class report given to vessel stating condition of class to repair pipes at next drydocking 14 July 2005
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 July 2005
Resolved 11 July 2005
Resolution: Rceived faxed class report outstanding deficiencies corrected.
Construction/Loadline › Structures › Machinery Space Opening
Issued 7 May 2005 Resolved
Vessel to provide class report on crack in WTBH main deck entrance to Fuel oil/ engine room space. Fax copy to U.S. Coast Guard when yard package complete. 12MAY05 - Received class report given to vessel stating condition of class to repair water tight bulk head at next drydocking 14 July 2005.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 July 2005
Resolved 11 July 2005
Resolution: Received faxed class report corrected outstanding deficiencies.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 11 February 2005 Resolved
Defective Transducer found to be the cause of inoperational Echo Sounder. Received Condition of Class recommending the repairs be made at next scheduled dry-dock.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 14 July 2005
Resolved 11 February 2005
Resolution: Activity already open by another port. Activity this DEF is attached to has been marked as Delete/Opened in error.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 9 September 2004 Resolved
Echo depth sounder did not function when energized. LOD issued for departure.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 9 November 2004
Resolved 12 May 2005
Resolution: Received tech report stating that the echo depth sounder was fixed and functioning properly.
Pollution Prevention/Response › Prevention Equipment
Issued 17 July 2003 Resolved
See Narrative
Due 17 July 2003
Resolved 28 July 2003
Resolution: Recieved a copy of the IOPP and sent the copy to LOSMS
Navigation
Issued 4 August 2001 Resolved
VESSEL'S PRIMARY RADAR INOPERABLE.
Condition: Unknown
Due 4 August 2001
Resolved 6 August 2001

Ownership record