← All vessels
AETOS
AETOS is a 1980 tank ship. The Coast Guard has recorded 24 inspections since 1985, most recently in June 2008, along with 40 deficiencies — 2 with no resolution recorded — and 8 operational controls.
Records from 1985 to 2008. Most recent: inspection, 6 June 2008.
- Built
- 1980
- Last inspected
- 6 June 2008
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 40 recorded · 2 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8000599 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ELAH2
228174
Flag
LIBERIA
—
Maury page id
psix-228174
Inspections, by type
…with no type recorded16
…past their stated due date2
Years with a record
6 calendar years (1985–2008)
The 24 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it22943 - Regulatory (Subpart C or D), Gross Ton
37405 - Dead Weight, Ton
10786 - Regulatory (Subpart C or D), Net Ton
37405 - Dead Weight, Ton
10786 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 24
6 June 2008
NPV Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3229470
5 June 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3228335
4 June 2008
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3227169
29 May 2008
PI Safety Exam · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3221554
3 February 2008
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3141092
25 January 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3136644
21 January 2008
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3133934
15 January 2008
COC-CHEM Renew · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3128495
5 November 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 295403
20 October 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 480912
18 October 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 294896
25 June 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 290966
25 June 2001
Tank Vessel Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1068521
9 January 2001
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 285699
19 February 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 274978
19 February 2000
Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1365586
23 December 1996
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 524899
19 February 1996
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 388053
19 February 1996
Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 884792
16 June 1992
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 351505
16 June 1992
Certificate of Compliance
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 945258
18 December 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 442707
15 April 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1293712
13 April 1985
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 301613
Deficiency record · 40
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 30 May 2008
Resolved
SOLAS 74 I/11 Upon inspection subsequent to a marine casualty, PSCO inspectors identified a significant # of def.'s that, individually may not warrant detention but collectively based on the significance and # of def.'s made the ship substandard with respect to compliance with international requirements. Ship detained.
Personnel › Training › Fire Fighting Basic
Issued 30 May 2008
Resolved
SOLAS 74 XI-1.4 SOLAS 74 IX 13, ISM 1.4 (2004 cons) Vessel's crew failed to perform a fire drill in the galley; 2 of the 3 crew members who dressed out to fight the fire were unable to properly operate their breathing apparatus. Class to attest to crew training and ability to effectively respond to a fire on board the vessel. To the satisfaction of Class, RO RSO, and the CG.
Lifesaving › Lifeboat Equipment › Radio (fixed two-way VHF radio-telephone)
Issued 30 May 2008
Resolved
SOLAS 74XI-1/4 SOLAS 74 IX 13, ISM1.4. During abandon ship vessel crewmembers failed to bring lifeboat radios and SARTS to the lifeboats and failed to have a crewmember designated for operation of the GMDSS suite and sending distress call report to the bridge. Also lifeboat was not effectively lowered or recovered. To the satisfaction of Class, RO RSO, and the CG.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 30 May 2008
Resolved
SOLAS 74 II-2/14.2 All doors required to be self closing A boundary doors for engine room (5) failed to properly close as required. Also 2 of 5 doors in main stair tower failed to properly close. Reducing ability to prevent fire spread. Class to attest to proper operation of all self closing fire doors and removal of hold backs. To the satisfaction of Class, RO RSO, and the CG.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 30 May 2008
Resolved
SOLAS 74 III/20.2 12 of 35 food rations in portside lifeboat found holed/wasted/unusable. Class to attest to renewal. To the satisfaction of Class, RO RSO, and the CG.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 30 May 2008
Resolved
SOLAS 74 II-2/14.2.1 Vessel crew able to get the emergency fire pump running after approx 25 min.; however even then pressure to 2 required hoses was not sufficient. Also one crew member was required to manually tend pump throttle, as well as pump packing showing a continuous leak of water. Class to attest to proper operation. To the satisfaction of Class, RO RSO, and the CG.
Navigation › Collision/Grounding Avoidance › Radar
Issued 30 May 2008
Resolved
SOLAS 74 V/16 Vessel's 3GHZ (2ndary) radar is operable with antenna tied to mast. To request for deviation as allowed by 33CFR 164.53 Class to attest to radar operability to ensure vessel can safely navigate. To the satisfaction of Class, RO RSO. Issued outbound LOD 14-08 for inop radar.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 30 May 2008
Resolved
MARPOL 73 I/14 SOLAS 74 I/11 Vessel's OWS inoperative upon initial insp. After significant matainance OWS was demonstrated operable however stage 2 of 3 was found holed in 5 locations reducing OWS function and spraying water in vicinity of OWS. Class to attest to proper operation of OWS and content meter. To the satisfaction of Class, RO RSO, and the CG.
Deck/Cargo › Towing › Winch
Issued 30 May 2008
Resolved
SOLAS 74 I/11 Vessel's winch/windlass on fantail, port side is heavily leaking with hydraulic oil in containment. Outside containment posing significant risk of oil discharge into water. Class to attest to windlass operation and full cleaning of vessel fantail. Similarly windlass midship on STBD side. (see attached form B page 4)To the satisfaction of Class, RO RSO, and the CG.
Electrical › Electric Generation Source (service) › Generator
Issued 30 May 2008
Resolved
SOLAS 74 I/11 #2 Aux engine (generator) is slinging oil into overhead outboard/ above engine. Class to attest to proper operation of engine and cleaning of overhead. To the satisfaction of Class, RO, and RSO.
Fire Fighting › Fire Bucket › Quantity
Issued 30 May 2008
Resolved
SOLAS 74 I/11 Several items of machinery found served by oil collection buckets half full of oil presenting fire risk. Class to attest to removal of oil/fire risk presented by collection buckets and address machinery condition as appropriate. (see attached form B for examples of above page 5) To the satisfaction of Class, RO, and the RSO.
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 30 May 2008
Resolved
SOLAS 74 II-2/14.2.1 Found fire extinguisher labeled "defective" in station on machinery space upper level. Class to attest to serviceability of suspect extinguisher. To the satisfaction of Class, RO, and the RSO.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 30 May 2008
Resolved
SOLAS 74 III/20.2 Light for lighted lifebuoy at port side pilot station found inoperable. Class to attest to renewal/repair to ensure availability of life saving appliance. To the satisfaction of Class, RO, and the RSO.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 30 May 2008
Resolved
SOLAS 74 IX/ 3 ISM Code 12.3 Upon review of vessels non conformity reports PSCO’s found that most had not been fully closed through verification at company level. RO to attest to completion of correction of corrective action/ non conformity resolution and record keeping. Recommend audit by RO Complete records found for only 1,2,4 from 07of 25 reports. To the satisfaction of Class, RO, and the RSO
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 30 May 2008
Resolved
SOLAS 74 I/11 Hydraulic oil leaks in steering gear and power pack room resenting slip/ trip hazard. To the satisfaction of Class, RO, and the RSO.
Deck/Cargo › Cargo Stowage › General
Issued 30 May 2008
Resolved
SOLAS 74 I/11 Cargo samples not being maintained as required (not well ventilated, not cell divided, not designated space in cargo area.) To the satisfaction of Class, RO, and the RSO.
Deck/Cargo › Vapor Control Systems › Vapor Recovery Unit
Issued 30 May 2008
Resolved
SOLAS 74 I/11 Prove proper calibration of atmospheric monitoring equipment 30 das or prior to loading cargos that require such equipment. To the satisfaction of Class, RO, and the RSO.
Deck/Cargo › Cargo Refrigeration › General
Issued 30 May 2008
No resolution recorded
SOLAS 74 I/11 Cargo tank temp. monitoring system showing faulty low temp (0 degrees) in tank 4 port. 30 days or prior to temp. controlled cargo. To the satisfaction of Class, RO, and the RSO.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 30 May 2008
No resolution recorded
SOLAS 74 I/11 Fire control plan does not specify location of fire suits and does not label class a and class b boundaries as required. To the satisfaction of Class, RO, and the RSO.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 May 2008
Resolved
SOLAS 74 I/11 Exposed wiring in power pack room on aft bulkhead (outboard) and out board of power pack #3 and #5. To the satisfaction of Class, RO, and the RSO.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 May 2008
Resolved
SOLAS74I/11 EDG Drive belts not served by guard for crew protection. To the satisfaction of Class, RO, and the RSO.
Engineering › Bilge Water Management System › Interface Detector
Issued 30 May 2008
Resolved
SOLAS 74 I/11 Prove proper operation of aft bilge level alarm in engine room. To the satisfaction of Class, RO, and the RSO.
Engineering › Steering Gear System › Rudder
Issued 29 May 2008
Resolved
Vessel's rudder will intermittently hang at a position and not follow through with the position and not follow through with the position commands indicated at the helm. For example, rudder angle indicator repeaters (Bridge, Port & Starboard bridge wings) and the steering gear itself, froze at 4 degrees port while the helm control was at 15 degrees starboard. Class to attest.
SOLAS74 II-1/29a(iv)
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 21 January 2008
Resolved
Vessel requested a letter of deviation for its outbound transit, due to an inoperable gyro repeater.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 15 January 2008
Resolved
A vessel response plan waiver was granted for the vessel to operate within the COTP Cape Fear River Zone. The vessel had submitted a VRP to Coast Guard Headquarters and is waiting on approval.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 11 January 2008
Resolved
EMERGENCY FIRE PUMP WILL NOT START. (Correct prior to departure to the satisfaction of class.)
Construction/Loadline › Structures › Door
Issued 11 January 2008
Resolved
FIRE DOORS LEADING TO MAIN STAIRWELL CANNOT CLOSE OR SEAL ON MULTIPLE DECKS.
Engineering
Issued 18 October 2001
Resolved
Mechanical failure of vessel's clutch resulting in inability to operate under own propulsion. Repairs to be carried out prior to departing port.
Electrical
Issued 25 June 2001
Resolved
Renew electrical conduit where wasted around various areas on cargo deck. SOLAS 60 I/11. Correct to the satisfaction of classs prior to next U. S. Port after sailing foriegn.
Deck/Cargo
Issued 25 June 2001
Resolved
Renew plugs to hydraulic actuator units where wasted throughout main deck under green actuator boxes. SOLAS 60 I/11. Repairs to be carried out to the satisfaction of class prior to next U. S. port after sailing foriegn.
Fire Fighting
Issued 25 June 2001
Resolved
Repair as original deck foam system piping where holed inboard of starboardmanifold. SOLAS 60 I/11. Repairs to be carried out to the satisfaction of class prior to next U.S. Port after sailing foriegn.
Construction/Loadline
Issued 25 June 2001
Resolved
Provide class approval of patch on port sea strainer connected to sea chest. SOLAS 60 I/11. Prior to departure.
Construction/Loadline
Issued 25 June 2001
Resolved
Repair heat exchanger to generator engines where leaking. SOLAS 60 I/11. Prior to departure to the satisfaction of class. Repairs to be carried out to the satisfaction of class prior to next U.S. port after sailing foriegn.
Engineering
Issued 25 June 2001
Resolved
Provide standard oil discharge connection. SOLAS 60 I/11. Prior to next U.S. port after sailing foriegn.
Lifesaving
Issued 25 June 2001
Resolved
Stencil General Alarm switch in lower E/R forward. SOLAS 60 I/11
Engineering
Issued 25 June 2001
Resolved
Repair both diesel generators and both main propulsion engines where leaking excessively. SOLAS 60 I/11.
Deck/Cargo
Issued 9 January 2001
Resolved
WINCH FOR STARBOARD LOADING ARM LEAKING HYDRAULIC OIL FROM A BAD GASKET. CORRECT PRIOR TO NEXT U.S. PORT.
Deck/Cargo
Issued 9 January 2001
Resolved
SCUPPER PLUGS WERE RUSTED IN PLACE, AND CORRODED. SCUPPERS COULD NOT BE OPENED OR TIGHTENED BY MECHANICAL MEANS. CORRECT PROR TO 09APR01.
Fire Fighting
Issued 19 February 2000
Resolved
STAIR TOWER DOORS WERE HELD OPEN BY HOOKS. WHEN HOOKS WERE REMOVED 3 OF 5 DOORS WOULD NOT CLOSE. PROVIDE CLASS REPORT PRIOR TO NEXT US PORT AFTER SAILING FOREIGN.
Engineering
Issued 13 April 1985
Resolved
VESSEL DID NOT HAVE STANDARD DISCHARGE CONNECTION ONBOARD AT THE TIME OF THE INSPECTION.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.