MAURY USCG vessel records Sign in
← All vessels

KING GEORGE

KING GEORGE is a 1982 tank ship. The Coast Guard has recorded 43 inspections since 1985, most recently in May 2005, along with 28 deficiencies and 2 operational controls, 1 with no removal date recorded.

Records from 1985 to 2005. Most recent: inspection, 10 May 2005.

Built
1982
Last inspected
10 May 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

8001402 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228179
Flag
PANAMA
—
Maury page id
psix-228179

Inspections, by type

…with no type recorded32
Years with a record 15 calendar years (1985–2005)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it16968 - Regulatory (Subpart C or D), Gross Ton
29665 - Dead Weight, Ton
11595 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

OCEAN LIGHT Freight Ship · MISLE 475353 · 10 May 2005 · activity 2360112B. NO. 135 Tank Barge · MISLE 48387 · 6 April 1997 · activity 538408

Inspection history · 43

10 May 2005 Type not recorded
No type recorded · USCG Southwest District (dpw) · USCG Southwest District (CGD-SW) · Activity 2360112
7 May 2005 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2351975
4 May 2005 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2349514
4 May 2005 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2355075
2 March 2004 Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2016486
2 March 2004 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2016500
16 December 2003 Administrative Inspection
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1964853
24 November 2003 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1953404
24 November 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1953879
21 November 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1954606
29 July 2002 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1653604
17 January 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 286009
9 October 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 283883
30 May 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 278310
11 August 1999 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 777814
10 August 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 431533
3 September 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 723907
13 August 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 506183
6 August 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 420690
28 June 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2814
11 February 1998 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 469872
8 July 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 408452
8 July 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 693509
7 July 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 405544
7 July 1997 Tank Vessel Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1114916
6 April 1997 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 538408
2 March 1997 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 498772
3 June 1996 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 458051
29 May 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1084868
20 May 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 391212
10 May 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 366764
10 May 1994 Tank Vessel Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1405542
11 March 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 366820
5 April 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 490146
5 April 1988 Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 994491
31 March 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 315153
31 March 1987 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1328142
3 January 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 306163
3 January 1986 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 987505
27 September 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 448093
15 April 1985 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 301157
12 April 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 301433
7 January 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 299658

Deficiency record · 28

Deck/Cargo › Holds/Tanks
Issued 24 November 2003 Resolved
PROVIDE CLASS RECOMENDATIONS/REPORT FOR TEMP REPAIR TO HOLE IN 5 P VENT RISER PIPE LEGACY COMPONENT DESC: Ventilation Exhaust Outlet
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 24 November 2003
Resolution: corrected by phims
Deck/Cargo › Holds/Tanks
Issued 24 November 2003 Resolved
PROVIDE CLASS REPORT TO SATISFACTORY PERMANENT REPAIR TO HOLE IN 5P VENT RISER LEGACY COMPONENT DESC: Ventilation Exhaust Outlet
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 2 December 2003
Resolution: receved fax from class.
Deck/Cargo › Holds/Tanks
Issued 24 November 2003 Resolved
PROVIDE CLASS REPORT TO THE REPLACMENT OR REPAIR & TESTING OF DRAIN COCKS ON ALL VENT RISER CHECK VALVE/TRAPS LEGACY COMPONENT DESC: Ventilation Exhaust Outlet
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 24 November 2003
Resolution: corrected by phims
Lifesaving › Hand Flares
Issued 24 November 2003 Resolved
PORT &STBD LIFEBOATS EACH MISSING 2 FLARES LEGACY COMPONENT DESC: Quantity
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2003
Resolved 25 November 2003
Lifesaving
Issued 24 November 2003 Resolved
CONDUCT SATISFACTORY FIRE & ABANDON SHIP DRILLS
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2003
Resolved 24 November 2003
Resolution: corrected by phims
Deck/Cargo
Issued 29 July 2002 Resolved
PRIOR TO THE DEPARTURE OF THE PORT OF PHILADELPHIA, PROVIDE CLASS APPROVAL THE BUTTERWORTH HATCH COVERS MEET THE REQUIREMENTS OF SOLAS CHAP 2-2 REG 429(1) OR PROVIDE CONDITION OF CLASS TO REPLACE HATCH COVERS WITH STEEL.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 4 August 2002
Resolved 30 July 2002
Resolution: RECIEVED CLASS REPORT REGARDING THE BUTTERWORTH HATCH COVERS.
Deck/Cargo
Issued 29 July 2002 Resolved
PROVIDE CLASS REPORT TO THE PROPER OPERATION/LABELING OF CARGO TANK OVERFILL ALARMS
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 4 August 2002
Resolved 30 July 2002
Resolution: RECIEVED CLASS FOR THE TESTING AND PROPER OPERATION OF TANK OVER FILL ALARMS.
Pollution Prevention/Response › Response Equipment
Issued 29 July 2002 Resolved
PROVIDE NON SPARKING SHOVELS LEGACY COMPONENT DESC: Non-sparking Hand Scoops/Shovels/Buckets
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 4 August 2002
Resolved 30 July 2002
Resolution: RECIEVED FAXED RECIEPT FOR 8 NON SPARKING SHOVELS.
Deck/Cargo
Issued 17 January 2001 Resolved
IAW W/ TELEX RECVD FROM VSL ADMIN, HIGH HIGH LEVEL ALARMS (ON DECK) REMAIN INOP TO BE REPAIRED IN NL. PROVE PROPER REPAIRS, TO SATISFACTION OF CLASS,PRIOR TO LOADING OIL CARGOS IN U.S. WATERS. NO LATER THAN 30 DAYS, FAX USCG COPY OF CLASS REPORT.
Condition: Unknown
Due 17 February 2001
Resolved 28 July 2002
Resolution: CORRECTED BY PHIMS
Engineering
Issued 9 October 2000 Resolved
MARK EMERGENCY LIGHTERING EQUIPMENT (12X16, 12X8, 12X10 REDUCERS) IN ACCORDANCE WITH 33 CFR 157.410 NO LATER THAN 09NOV00
Condition: Unknown
Due 18 January 2001
Resolved 18 January 2001
Fire Fighting
Issued 9 October 2000 Resolved
REPAIR PIN HOLE LEAK IN FIRE MAIN BRANCH LINE TO FIRE STATION #15 ON MAIN DECK FORWARD, IN ACCORDANCE WITH SOLAS 74 AMM. /II-2 REG 21 (ALL SHIPS) NO LATER THAN 09NOV00
Condition: Unknown
Due 18 January 2001
Resolved 18 January 2001
Deck/Cargo
Issued 9 October 2000 Resolved
PROVIDE VISUAL AND AUDIBLE ALARMS ON DECK PRIOR TO VESSEL LOADING OIL CARGOES IN U.S. WATERS IN ACCORDANCE WITH 33 CFR 155.480 BUT NO LATER THAN 09NOV00.
Condition: Unknown
Due 18 January 2001
Resolved 18 January 2001
Deck/Cargo
Issued 10 August 1999 Resolved
IGS BLOWER EXPANSION BELLOWS CRACKED. RENEW TO THE SATISFACTION OF CLASS PRIOR TO LOADING CARGO.
Condition: Unknown
Due 13 August 1999
Resolved 19 August 1999
Deck/Cargo
Issued 10 August 1999 Resolved
F/O AND D/O CONTAINMENT PLUGS MISSING IN TANK DECK AREA. PROVIDE EXPANSION PLUGS FOR ALL CONTAINMENT.
Condition: Unknown
Due 13 August 1999
Resolved 19 August 1999
Fire Fighting
Issued 10 August 1999 Resolved
REMOVE PIPES FROM FIRE STATION #11.
Condition: Unknown
Due 13 August 1999
Resolved 19 August 1999
Deck/Cargo
Issued 10 August 1999 Resolved
CARGO ROOM MATERIAL CONDITION UNSATISFACTORY FOR USE. REPAIR TO SATISFACTION OF CLASS PRIOR TO USE IN THE UNITED STATES.
Condition: Unknown
Due 13 August 1999
Resolved 23 August 1999
Engineering
Issued 10 August 1999 Resolved
OILY WATER SEPARATOR 15PPM ALARM INOPERABLE. REPAIR ALARM TO THE SATISFACTION OF CLASS.
Condition: Unknown
Due 13 September 1999
Resolved 19 August 1999
Unknown
Issued 10 August 1999 Resolved
ODME INOPERABLE. REPAIR TO THE SATISFACTION OF CLASS.
Condition: Unknown
Due 13 September 1999
Resolved 19 August 1999
Construction/Loadline
Issued 10 August 1999 Resolved
LOADLINE NOT PAINTED PORT AND STARBOARD SIDE. REPAIR TO THE SATISFACTION OFCLASS.
Condition: Unknown
Due 13 September 1999
Resolved 19 August 1999
Lifesaving
Issued 10 August 1999 Resolved
LIFEBOAT GRABLINE RINGS BROKEN AND WASTED. REPAIR TO THE SATISFACTION OF CLASS.
Condition: Unknown
Due 13 September 1999
Resolved 19 August 1999
Lifesaving
Issued 10 August 1999 Resolved
LIFEBOAT LOWERING DAVIT SHEAVES, WIRES AND PIPING NEEDS REPLACED. REPAIR TOTHE SATISFACTION OF CLASS.
Condition: Unknown
Due 13 September 1999
Resolved 19 August 1999
Unknown
Issued 10 August 1999 Resolved
NO DIVIDER INSTALLED BETWEEN OXYGEN AND ACETYLENE BOTTLES. INSTALL DIVIDER TO THE SATISFACTION OF CLASS.
Condition: Unknown
Due 13 September 1999
Resolved 19 August 1999
Deck/Cargo
Issued 6 August 1998 Resolved
Vessel is prohibited from carrying flammable cargoes in the U. S. until the extensively patched cargo, IGS, COW, bunker & foam piping systems on deck are review by class and proper repairs area made. _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Navigation
Issued 7 July 1997 Resolved
VESSEL MUST AQUIRE THE CHARTS FROM SUISUN BAY TO STOCKTON PRIOR TO DEPARTING STOCKTON.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Lifesaving
Issued 20 May 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 June 1996
Resolved 4 June 1996
Fire Fighting
Issued 20 May 1996 Resolved
REPAIR/ INSTALL MAIN STAIR TOWER DOOR'S HYDRAULIC CLOSURE. CORRECT TO THE SATISFACTION OF CLASS SOCIETY. (SOLAS 74 CHAPTER II-2 REG. 57 (B)(7)ii.
Condition: Unknown
Due 20 May 1996
Resolved 21 May 1996
Deck/Cargo
Issued 10 May 1994 Resolved
Aleak was found in the mechanical seal of cargo pump #3. Make perminant repairs to stop leak prior to any cargo operation with this pump. Evaluateall cargo pumps for leaks and have class society verify there are no leaks prior to next U.S. Port.
Condition: Unknown
Due 10 May 1994
Resolved 10 May 1994
Deck/Cargo
Issued 7 January 1985 Resolved
VESSEL HAD NO SPAN GAS TO TEST PORTABLE INSTRUMENTS AS REQ BY 32.53-65 MARPOL 73/78 REGS
Condition: Unknown
Due 7 January 1985
Resolved 7 January 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.