Records from 1984 to 2008. Most recent: inspection, 4 December 2008.
Inspection history · 45
4 December 2008
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3370431
30 January 2008
Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3134857
13 June 2007
Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2955349
18 May 2006
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2652409
21 April 2006
PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2630275
28 March 2005
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2321610
22 March 2005
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2316557
16 December 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1964993
24 September 2003
Security Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1917396
26 June 2003
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1828346
26 May 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1801559
17 April 2003
Annual Inspection · Ballast Water Examination · Security Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1774892
27 April 2002
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1610001
25 April 2002
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1609562
23 April 2002
Security Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1607677
3 April 2001
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 288661
18 July 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 280081
6 June 2000
Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1051117
1 June 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 71333
13 April 2000
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 276866
20 December 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 435828
3 May 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 427824
17 March 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 426606
27 January 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 412137
30 September 1997
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 408342
26 August 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 407241
22 August 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 406930
11 December 1995
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 385677
8 November 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 667151
7 November 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 384577
7 November 1995
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 667152
3 November 1995
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 384464
2 February 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 364125
26 November 1990
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 440517
31 May 1990
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 337426
15 April 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 493254
14 March 1989
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 329015
20 October 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 326353
27 April 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 539641
30 July 1987
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 317590
7 January 1987
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 313669
7 June 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 309204
22 May 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 498732
20 May 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 302100
31 October 1984
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 298649
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 4 December 2008
Resolved
Excessive diesel oil covering the main diesel engine (MDE) due to multiple leaks. Found oil saturated rags and oil saturated lagging around MDE, posing fire hazards to ship. 2004 SOLAS Ch. I/11. Action taken: 17A.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2008
Resolved 5 December 2008
Resolution: All broken pipes of the main diesel engine (MDE) injection pumps were replaced and the MDE cylinder blocks, port and starboard, and surrounding areas of the MDE were cleaned. The RO was unresponsive and did not attend the vessel.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 30 January 2008
Resolved
Firefighter's outfits have tears and are delaminated
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 February 2008
Resolution: Two out of three required firefighter''s outfits were replaced with new, approved firefighter''s outfits. Currently, three satisfactory outfits are onboard, as attested by Bureau Veritas class surveyor and USCG Port State Control inspectors.
Personnel › Training › Fire Fighting Basic
Issued 30 January 2008
Resolved
During fire drill, crew did not secure doors to space with fire, and crew entered and exited space with fire multiple times.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 February 2008
Resolution: Fire drill conducted to satisfaction of attending Bureau Veritas class surveyor and USCG port state control inspectors.
Fire Fighting › Self-contained Breathing Apparatus › Hose
Issued 30 January 2008
Resolved
Two out of three required SCBA's have leaks in the supply hoses. SOLAS 74 II-2/14 17a,c
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 February 2008
Resolution: Shortly after writing deficiency, o-rings were replaced and fittings tightened. SCBA''s were retested satisfactorily in front of Bureau Veritas class surveyor and USCG Port State Control inspectors.
Fire Fighting › Structural - A Class Divisions › Ro-ro Cargo Spaces
Issued 21 April 2006
Resolved
Vessels fire control plan does not meet requirements of 74 SOLAS (Identification of "A" class divisions and & "B" class divisions).
70a
1974 SOLAS CH II-2 Reg 4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 May 2006
Resolution: Reviewed up-dated fire control plans in Yokohama Japan on 09May06 by Class Bureau Veritas Inspectors.
Navigation › Collision/Grounding Avoidance
Issued 23 April 2002
Resolved
Vessel's No. 1 radar (3 cm) inoperable. LEGACY COMPONENT DESC: Radar
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2002
Resolved 24 April 2002
Resolution: Mackay Marine replaced inoperable radar with new unit. Vessel now has two independently functioning radars.
Operations/Management › Port and Waterways Safety
Issued 23 April 2002
Resolved
Person directing movement of the vessel (master) did not report inoperable No. 1 (3 cm) radar to USCG prior to entering U.S. waters. Provide Letter of Undertaking (LOU) to MSD Santa Barbara in amount of $55,000.00. LEGACY COMPONENT DESC: Notice of Hazardous Condition
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2002
Resolved 23 April 2002
Resolution: P & I Club representative provided LOU to MSD Santa Barbara.
Lifesaving › Lifeboat
Issued 23 April 2002
Resolved
Keel nuts and bolts severely corroded and wasted on port lifeboat. SOLAS 74(amended) Ch III, Reg. 19.2
Must be corrected prior to departing U.S. waters. LEGACY COMPONENT DESC: Embarkation/Disembarkation Capabilities
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2002
Resolved 25 April 2002
Fire Fighting › Miscellaneous Items
Issued 23 April 2002
Resolved
#2 Fire-fighting locker not marked IAW Fire Control Plan. Markings show International Shore Connection is stored within the locker. Shore Connection is not stored in locker. SOLAS 74(amended) Ch II-2, Reg 20. Vessel must ensure locker markings match actual stowage and Fire Control Plan.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 May 2002
Resolved 25 April 2002
Fire Fighting › Firemans Outfit
Issued 23 April 2002
Resolved
Fireman outtfits are not sufficiently sized to allow all crewmembers to wear. ILO 147 Provide appropriate sizes on board vessel.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 May 2002
Resolved 25 April 2002
Operations/Management › Drills/Instruction
Issued 23 April 2002
Resolved
Could not witness Abandon Ship Drill due to unsafe port lifeboat (vessel was moored starboard side). Vessel must perform satisfactory abandon ship drill when port lifeboat repairs have been completed or vessel is moored port side. LEGACY COMPONENT DESC: Abandon Ship
Due 24 April 2002
Resolved 25 April 2002
Unknown
Issued 13 April 2000
Resolved
REF REQUIREMENT 006 THIS CASE. CLASS VERIFIED TEMP REPAIR SAT. CLASS INDICATED PERMANENT REPAIRS TO BE AFFECTED NLT 12AUG00. SEE BV FAX DATED 16APR00 THIS DATE.
Condition: Unknown
Due 11 December 2000
Resolved 11 December 2000
Accommodation/Occupational Safety
Issued 13 April 2000
Resolved
INSULATE WALK-IN FREEZER'S EMERGENCY ESCAPE DEVICE (PUSH HANDLE).
Condition: Unknown
Due 19 July 2000
Resolved 19 July 2000
Deck/Cargo
Issued 13 April 2000
Resolved
PROVIDE GUARDS IWO ANCHOR HAWSE PIPES.
Condition: Unknown
Due 19 July 2000
Resolved 19 July 2000
Accommodation/Occupational Safety
Issued 13 April 2000
Resolved
MAKE REPAIRS TO TOILET IN HOSPITAL SPACE FOR A PROPER FLUSH.
Condition: Unknown
Due 11 December 2000
Resolved 11 December 2000
Engineering
Issued 13 April 2000
Resolved
PROVIDE IMO CERTIFICATION LABEL OR COAST GUARD APPROVAL NUMBER FOR OILY WATER SEPERATOR.
Condition: Unknown
Due 19 July 2000
Resolved 19 July 2000
Unknown
Issued 13 April 2000
Resolved
FOUND NUMBER TWO (2) PROPULSION ENGINE'S FRESH WATER PUMP JURY RIGGED WITH MAIN BLOWER SUPPLY VENT AIR ON PUMP'S MOTOR. CLASS SURVEYOR TO VERIFY AND PROVIDE STATEMENT OF ADEQUATE COOLING WATER SUPPLY CONFIGURATION.
Condition: Unknown
Due 18 April 2000
Resolved 18 April 2000
Construction/Loadline
Issued 13 April 2000
Resolved
CLASS SURVEYOR TO EVALUATE AND PROVIDE STATEMENT FOR SHARP SET-IN FOUND IN HULL 27 FEET AFT OF FORWARD ENGINE ROOM BULKHEAD, 15 FEET ABOVE WATERLINE, AND 2 FEET BELOW TURN OF BIRDGE.
Condition: Unknown
Due 17 April 2000
Resolved 18 April 2000
Construction/Loadline
Issued 13 April 2000
Resolved
FOUND SPOOL PIECE FOR PORT STEAM BLOW DOWN WITH CEMENT PATCH. CLASS. SURVEYOR TO VARIFY AND PROVIDE STATEMENT OF ADQUATE REPAIR.
Condition: Unknown
Due 27 April 2000
Resolved 18 April 2000
Fire Fighting
Issued 20 December 1999
Resolved
Supply piping for CO2 system inadequate.
Condition: Unknown
Due 18 April 2000
Resolved 18 April 2000
Engineering
Issued 20 December 1999
Resolved
Port steam blowdown spool piece rotted by oily water seperator.
Condition: Unknown
Due 18 April 2000
Resolved 18 April 2000
Construction/Loadline
Issued 20 December 1999
Resolved
Free standing oil in engine room bilges.
Condition: Unknown
Due 18 April 2000
Resolved 18 April 2000
Lifesaving
Issued 17 March 1999
Resolved
STARBOARD SIDE LIFEBOAT MOTOR WAS DAMAGED DURING OPERATION TEST. VESSEL ISREQUIRED TO REPAIR AND PROVIDE CLASS REPORT FOR REPAIR PRIOR TO DEPARTURE.
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Electrical
Issued 17 March 1999
Resolved
SHOCK RESISTANT MATS WERE NOT IN FRONT OF MAIN SWITCHBOARD PANEL IN ENGINE CONTROL ROOM. VESSEL MUST HAVE MATS IN PLACE PRIOR TO NEXT U.S. PORT AFTERSAILING FOREIGN.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Unknown
Issued 22 August 1997
Resolved
PRESSURIZED FREON BOTTLE PORT SIDE ENGINEROOM NOT SECURED._x001C_ _x001C_ _x001C_ ILO 147
Condition: Unknown
Due 1 October 1997
Resolved 1 October 1997
Fire Fighting
Issued 22 August 1997
Resolved
NO CLOSURE DEVICES FOR VENTS IN PAINT LOCKER AND BATTERY ROOM._x001C_ _x001C_ _x001C_ SOLAS REG II-2/25(C)
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Lifesaving
Issued 22 August 1997
Resolved
SEVERAL LIGHTS IN TOOL SHOP MISSING PROTECTIVE CAGES._x001C_ _x001C_ _x001C_ SOLAS AMENDED REG II-1/40.1.3
Condition: Unknown
Due 1 October 1997
Resolved 1 October 1997
Lifesaving
Issued 22 August 1997
Resolved
ELECTRICAL HAZARD DUE TO NON-PERMANENT LIGHTING IN TOOL ROOM._x001C_ _x001C_ _x001C_ SOLAS AMENDED REG II-1/40.1.3
Condition: Unknown
Due 1 October 1997
Resolved 1 October 1997
Engineering
Issued 22 August 1997
Resolved
LEAK IN COOLING WATER/SANITARY PIPING IN ENGINEROOM._x001C_ _x001C_ _x001C_ SOLAS REG I/11
Condition: Unknown
Due 1 October 1997
Resolved 1 October 1997
Lifesaving
Issued 22 August 1997
Resolved
LIGHT BATTERIES EXPIRED ON FIVE IMMERSION SUITS._x001C_ _x001C_ _x001C_ SOLAS AMENDED REG III/19.2
Condition: Unknown
Due 1 October 1997
Resolved 1 October 1997
Unknown
Issued 22 August 1997
Resolved
TWENTY-FOUR DRUG ITEMS IN PHARMACY WERE EXPIRED. ILO 147
Condition: Unknown
Due 1 October 1997
Resolved 1 October 1997
Navigation
Issued 22 August 1997
Resolved
NUMEROUS LEAKS (HYDRAULIC OIL) IN STEERING GEAR SYSTEM._x001C_ _x001C_ _x001C_ SOLAS REG II-2/29
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Navigation
Issued 7 November 1995
Resolved
A violation of 33 CFR 164.30 in that US Coast Pilot Volume 3 1994 Edition used by the vessel was not currently corrected through Notice to Mariners 44/95 which were reasonably available and required for the vessels transit to the port of Wilmington, DE. IAW 33 CFR 164.33(a)(2)(i).
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Navigation
Issued 7 November 1995
Resolved
A violation of 33 CFR 164.11(c) in that the master did not ensure that the vessels position was plotted on charts of the area .
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Navigation
Issued 7 November 1995
Resolved
A violation of 33 CFR 164.30 in that the vessel did not have a copy_x001C_ of US chart 12313 or any foreign equivalent which were required by 33 CFR 164.33(a)(1)(i) for the vessels transit into the Port of Wilmington, DE.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Navigation
Issued 7 November 1995
Resolved
A violation of 33 CFR 164.30 in that US charts 12214, 12304, 12311 and 12312 used by the vessel were not currently corrected through Notice to mariners 44/95 which were reasonably available and required for the vesselstransit to the port of Wilmington, DE. IAW 33 CFR 164.33(a)(1)(ii).
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Navigation
Issued 7 November 1995
Resolved
A violation of 33 CFR 164.30 in that USCG Light List Volume II 1990 editionused by the vessel was not currenlty corrected through notice to mariners 44/95 which were reasonably available and required for the vessels transit to the port of Wilmington, DE.
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Navigation
Issued 3 November 1995
Resolved
Vsl was required to provide onboard a currently corrected entrance chart for Brunswick, Ga.
Condition: Unknown
Due 3 November 1995
Resolved 6 November 1995
Navigation
Issued 3 November 1995
Resolved
Vsl was required to provide onboard, a currently corrected U.S. Coastpilot (vol-IV) or foreign equivalent.
Condition: Unknown
Due 3 November 1995
Resolved 6 November 1995
Navigation
Issued 3 November 1995
Resolved
Vsl was required to provide onboard, a currently corrected U.S. Lightlist (vol-III) or foreign equivalent.
Condition: Unknown
Due 3 November 1995
Resolved 6 November 1995
Fire Fighting
Issued 3 November 1995
Resolved
Vsl was required to repair/replace the cut off valve on the one inch priming line for the emergency fire pump.
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Documentation
Issued 31 May 1990
Resolved
THE VESSEL'S OIL RECORD BOOK PART 1 (MACHINERY SPACE OPERATIONS) DID NOT CONTAIN THE PROPER ENTRIES FOR DISCHARGE OVERBOARD OF BILGE WATER THAT HAS ACCUMULATED IN MACHINERY SPACES AS REQUIRED BY 33CFR151.25(D)(4).
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Navigation
Issued 20 October 1988
Resolved
VESSEL TRANSITED PUGET SOUND WATERS WITH CHARTS NOT CURRENTLY CORRECTED WITH CHANGES CONTAINED IN NOTICE TO MARINERS OR AN EQUIVALENT FOREIGN GOVERNMENT CHARTS. 33 CFR 164.33(A)(1)(II)
Condition: Unknown
Due 20 October 1988
Resolved 20 October 1988
Documentation
Issued 20 October 1988
Resolved
VESSEL'S DECLARATION OF INSPECTION WAS IMPROPERLY COMPLETED. 33 CFR 156.150
Condition: Unknown
Due 20 October 1988
Resolved 20 October 1988
Navigation
Issued 20 October 1988
Resolved
VESSEL TRANSITED PUGET SOUND WATERS WITH U.S. COAST PILOT NOT CURRENTLY CORRECTED WITH CHANGES CONTAINED IN NOTICE TO MARINERS OR EQUIVALENT FOREIGN GOVERNMENT CHARTS. 33 CFR 164.33(A)(2)(I)
Condition: Unknown
Due 20 October 1988
Resolved 20 October 1988
Documentation
Issued 20 October 1988
Resolved
OIL TRANSFER PROCEDURES WERE NOT AVAILABLE AT THE BUNKERING STATION DURING TRANSFER OPERATIONS. 33 CFR 155.740(C)
Condition: Unknown
Due 20 October 1988
Resolved 20 October 1988
Navigation
Issued 7 June 1986
Resolved
A VIO OF 33 CFR 164.30 IN THAT A COMPLETE SET OF CURRENTLY CORRECTED U.S. CHARTS OR THEIR FOREIGN EQUIV OF THE AREA TRANSITED AS REQ BY 33 CFR 164. 33(A)(1)(II) WAS NOT O/B. THE VSL HAD O/B U.S. CHARTS #12222 DTD JUN85 WITHNO CORRECTIONS AND #12253 DTD JUN 84 WITH NO CORRECTIONS.
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Navigation
Issued 20 May 1985
Resolved
VESSELS NOS CHART 18751 WAS NOT ON BOARD, AS WELL AS THE TIDE AND TIDAL CURRENT TABLES FOR 1985. USCG LIGHT LIST VOL. III WAS NOT CORRECTED TO DATE
Condition: Unknown
Due 7 January 1987
Resolved 20 May 1985