Records from 1984 to 2014. Most recent: inspection, 7 August 2014.
Inspection history · 70
7 August 2014
NPV Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4932549
4 May 2012
ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4290607
3 February 2012
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4237613
5 January 2012
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4219411
15 July 2011
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4082337
3 December 2010
PI Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3900360
30 October 2010
Deficiency Check · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3879270
8 March 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3691912
2 February 2009
Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3403360
24 October 2005
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2521200
13 October 2005
ISPS II Exam · COC-TVE Renew
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2513518
14 December 2002
Ballast Water Examination · Certificate of Compliance
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1718767
7 August 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1658195
23 February 2002
Security Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1488643
4 December 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 296088
8 November 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 295039
8 November 2001
Tank Vessel Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 772261
6 July 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 174200
2 June 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 278392
2 May 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 279199
20 November 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 434981
20 November 1999
Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1454740
19 August 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 274477
19 August 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 431961
20 November 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 422873
20 November 1998
Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1433418
15 June 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 416898
21 November 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 410316
21 November 1997
Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1416602
2 October 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 43092
10 September 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 407603
7 September 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 136086
26 June 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 101649
12 December 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 397796
12 December 1996
Tank Vessel Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1093438
2 December 1996
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 398120
28 December 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 386272
28 December 1995
Tank Vessel Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355606
14 January 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 374456
14 January 1995
Tank Vessel Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 864957
19 October 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 443554
3 July 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 34808
19 February 1994
Examination of Repairs
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1439477
7 January 1994
Tank Vessel Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 850628
14 December 1993
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 534800
29 June 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 512323
6 June 1993
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 828456
14 January 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 496460
12 January 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 355719
12 January 1993
Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 826921
13 March 1992
Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 953707
31 January 1992
Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 953241
31 January 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1255101
4 February 1991
Certificate of Compliance
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 903986
9 June 1990
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 535476
5 January 1990
Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1210942
21 August 1989
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 540200
20 December 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 539350
20 December 1988
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1037162
25 October 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 326404
24 August 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 527237
25 February 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 440266
10 December 1987
Certificate of Compliance
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1310568
9 June 1987
Type not recorded
No type recorded · COTP NEW HAVEN · USCG Northeast District (CGD-NE) · Activity 527859
9 January 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 313704
22 July 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 452365
8 January 1986
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 481893
10 June 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 302502
14 March 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 524699
5 November 1984
Type not recorded
No type recorded · COTP NEW HAVEN · USCG Northeast District (CGD-NE) · Activity 523189
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 4 May 2012
Resolved
2035 - Fire Control Plan - PSCO observed stairway doorways on the boat deck and Capt. deck would not close IAW approved fire control plan, both were classed as A-0 self-closing.
-SOLAS 74 II-2/4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 May 2012
Resolved 7 May 2012
Resolution: Received, reviewed, and accepted class report from NKK stating that both doors have been fixed and the self-closing operation is in order.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 4 May 2012
Resolved
1581 - Rudder Angle Indicator - All ships of 500 gt and upward should have a rudder mode indicator readable from the conning bridge. PSCO observed RAI on bridge reads 31 degrees to starboard when operated on the number 1 and 2 steering pumps when rudder is at 35 degrees.
-SOLAS 74 am V/19
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 May 2012
Resolved 7 May 2012
Resolution: Received, reviewed and accepted class report from NKK stating that the Angle Indicators were opened and cleaned then tested and the indications corresponded to the actually ruder angle.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 3 December 2010
Resolved
0950 - Electric Equipment in General - Emergency Fire Pump packing gland is spraying water in excess, creating an electrical shock hazard. Conduct repairs to the satisfaction of the certificate issuing authority. - SOLAS 74 am. II/I-45
Action required: 705 - Other - as specified
Due 10 December 2010
Resolved 6 December 2010
Resolution: Received, reviewd and accepted Class report from ABS atteswting to permanent repairs to the packing seals on the Emergency fire pump.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Liner
Issued 3 December 2010
Resolved
1410 - Propulsion main engine - PSCO identified a J/W leak leaking from the #6 MDE cylinder head/liner weep hole. Conduct repair to leak to the satisfaction of the certificate issuing authority. - SOLAS 74 am 1/II
Action required: 705 - Other - as specified
Due 10 December 2010
Resolved 6 December 2010
Resolution: Received, reviewed and accepted Class report from ABS attesting to the permanent repairs to the jacket water seal pn the #6 MDE cylinder.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 3 December 2010
Resolved
1440 - Bilge pumping arrangement - A flexible hose was discovered in the engine room bilge connected to the sludge pump. Certificate issuing authority to attest to the proper sludge piping configuration. - SOLAS 74 am. II/II-5, and MSC 647
Action required: 705 - Other - as specified
Due 10 December 2010
Resolved 6 December 2010
Resolution: Receieved, reviewed and accepted Class report from ABS attesting to the removal of the flex hose assembly.
Documentation › Certificates/Documents › IOPP Certificate
Issued 3 December 2010
Resolved
0150 - Oil Pollution Prevention (IOPP) - PSCO identified a MEPC 107(49) installed oil content meter. IOPP certificate depicts a MEPC 60(33) oil content meter installed. Request clarification from certificate issuing authority as to acceptance of installation or update IOPP/installation to reflect proper configuration of oil pollution prevention equipment. - MARPOL 73/78 Annex 1/Reg. 7
Action required: 705 - Other - as specified
Due 10 December 2010
Resolved 6 December 2010
Resolution: Received, reviewed and accepted Class report from ABS attesting to the update of the IOPP supplement.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 30 October 2010
Resolved
THE VESSEL'S #1 SHIP SERVICE GENERATOR WAS FOUND WITH FUEL OIL LEAKS ON THE #1,2,3, & 5 FUEL PUMPS POSING A SUBSTANTIAL FIRE HAZARD. TO THE SATISFACTION OF CLASS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2010
Resolution: Fuel leaks found in way of the vessel''s #1 ship service generator (SSG) were corrected by removal and replacement of the pump plunger seals. SSG was operated in the presence of undersigned and considered satisfactory.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 30 October 2010
Resolved
THE VESSEL'S #2 SHIP SERVICE GENERATOR WAS FOUND WITH FUEL OIL LEAKS ON THE #1 & 2 FUEL PUMPS AND #3 FUEL PUMP WAS SPRAYING FUEL OIL POSING A SUBSTANTIAL FIRE HAZARD. TO THE SATISFACTION OF CLASS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2010
Resolution: Fuel leaks found in way of the vessel''s #2 ship service generator (SSG) were corrected by removel and replacement of all six fuel pumps. SSG was operated in the presence of the undersigned and considered satisfactory.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 30 October 2010
Resolved
THE VESSEL'S #3 SHIP SERVICE GENERATOR WAS FOUND WITH FUEL OIL LEAKS ON THE #1 & #3,4, & 5 FUEL PUMPS AND #6 FUEL PUMP WAS SPRAYING FUEL OIL POSING A SUBSTANTIAL FIRE HAZARD. TO THE SATISFACTION OF CLASS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2010
Resolution: Fuel leaks found in way of the vessel''s #3 ship service generator (SSG) were corrected by removal and replacement of the pump plunger seals on pumps 1 through 4 and fuel pump 5 and 6. SSG was operated in the presence of the undersigned and considered s
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 30 October 2010
Resolved
EXCESSIVE OIL WAS PRESENT IN THE GENERATOR SPACE BILGES POSING A SUBSTANTIAL FIRE HAZARD. TO THE SATISFACTION OF CLASS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2010
Resolution: Excessive oil in the generator space bilges was removed, examined and considered satisfactory.
Lifesaving › Lifeboat › Propulsion Engine
Issued 30 October 2010
Resolved
JACKET WATER RESERVOIRS ON THE PORT AND STARBOARD LIFEBOATS WERE FOUND EMPTY. DURING OPERATIONAL TEST RESEVOIRS WERE FILLED AND LEAKS WERE DISCOVERED ON THE KEEL COOLERS. TO THE SATISFACTION OF CLASS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2010
Resolution: Port and starboard lifeboat keel coolers were removed and replaced. Jacket water resevoirs on port and starboard lifeboats were refilled. Engines were tested in the presence of the undersigned and considered satisfactory
Lifesaving › Lifeboat › Exhaust Pipe
Issued 30 October 2010
Resolved
AN EXHAUST LEAK WAS FOUND COMING FROM A HOLE IN THE MUFFLER LOCATED IN THE ENGINE COMPARTMENT OF THE STARBOARD LIFEBOAT. TO THESATISFACTION OF CLASS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2010
Resolution: Holes in the muffler installed on the starboard lifeboat was repaired by reinstallation of sealing bolts. Engine was operated in the presence of the undersigned and considered satisfactory.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 30 October 2010
Resolved
THE RESEVOIR OF THE HYDRAULIC STARTING MECHANISM ON THE PORT AND STARBOARD LIFEBOATS WERE FOUND LEAKING FLUID FROM THE PACKING OF THE HAND PUMP AND HOSE CONNECTIONS. TO THE SATISFACTION OF CLASS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2010
Resolution: Port and starboard lifeboats hydraulic resivoir was found missing breather cap gasket which caused the tank to overflow. This overflow created the appearance of fluid leaking from the pump handle hose connection. The hydraulic starting system on both lif
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 30 October 2010
Resolved
THE CAPTAIN COULD NOT PROVIDE SAFETY MANAGEMENT MANUALS TO THE U.S. COAST GUARD FOR REVIEW OF MAINTENANCE PROCEDURES. PSCO REQUESTED MULTIPLE TIMES OVER THE COURSE OF AN HOUR WHERE THE CAPTAIN WAS UNRESPONSIVE. TO THE SATISFACTION OF CLASS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2010
Resolution: Internal and external audits completed as required by USCG MSU Galveston.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 30 October 2010
Resolved
THE CAPTAIN COULD NOT PROVIDE ANY DOCUMENTATION OF NON-CONFORMITIES REPORTED TO THE COMPANY. THE SUPERINTENDENT STATED TO THE PSCO THAT THEY WERE DESTROYED OR REMOVED FROM THE VESSEL DUE TO FUTURE OPERATOR CHANGE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2010
Resolution: Internal and external audits were conducted as required by USCG MSU Galveston.
Lifesaving › Lifeboat › Propulsion Engine
Issued 30 October 2010
Resolved
A LUBE OIL LEAK WAS FOUND COMING FROM THE OIL PRESSURE GAUGE TUBING IN THE ENGINE COMPARTMENT OF THE PORTSIDE LIFEBOAT. TO THE SATISFACTION OF CLASS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2010
Resolution: Received class report attesting to proper repairs.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 30 October 2010
Resolved
RETRO REFLECTIVE TAPE ON TOP OF PORT AND STARBOARD LIFEBOATS WAS FOUND WEATHERED AND PEELING OFF. TO THE SATISFACTION OF CLASS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2010
Resolution: Received class report attesting to proper repairs.
Lifesaving › Lifeboat › Hull
Issued 30 October 2010
Resolved
A BOLT WAS MISSING FROM THE STARBOARD QUARTER RUB RAIL OF THE PORTSIDE LIFEBOAT LEAVING AN OPEN HOLE COMPROMISING THE WATERTIGHT INTEGRITY. TO THE SATISFACTION OF CLASS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2010
Resolution: Received class report attesting to proper repairs.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 October 2010
Resolved
LARGE OPENINGS WERE FOUND IN THE ENGINE CONTROL ROOM ON THE SWITCHBOARD PANEL POSING AN ELECTRICAL SHOCK HAZARD. TO THE SATISFACTION OF CLASS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2010
Resolution: Received class report attesting to proper repairs.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Liner
Issued 30 October 2010
Resolved
MAIN ENGINE CYLINDERS # 3, 5, & 6 WERE FOUND LEAKING COOLING WATER FROM EACH CYLINDER LINER. TO THE SATISFACTION OF CLASS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2010
Resolution: Received class report attesting to proper repairs.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 30 October 2010
Resolved
MAIN FIRE PUMP WAS FOUND LEAKING WATER EXCESSIVELY FROM THE PACKING GLAND. TO THE SATIASFACTION OF CLASS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2010
Resolution: Received class report attesting to proper repairs.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 30 October 2010
Resolved
THE EMERGENCY FIRE PUMP'S PACKING GLAND WAS FOUND SMOKING. 1ST ENGINEER ADJUSTED PACKING, WHICH LED TO THE PUMP LEAKING WATER EXCESSIVELY. TO THE SATISFACTION OF CLASS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2010
Resolution: Received class report attesting to proper repairs.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 30 October 2010
Resolved
VESSEL'S #3 SHIP SERVICE GENERATOR WAS FOUND TO HAVE COOLING WATER LEAKING ONTO THE TURBO. TO THE SATISFACTION OF CLASS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2010
Resolution: Received class report attesting to proper repairs.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 30 October 2010
Resolved
NUMEROUS CATEGORY "A" FIRE DOORS IN MAIN MACHINERY SPACE WERE NOT ARRANGED SO THAT POSITIVE CLOSURE COULD BE ASSURED. MECHANICAL TIE BACKS PREVENTED DOORS FROM CLOSING AND SEVERAL WERE FOUND TO BE INOPERABLE. VERIFY PROPER OPERATION OF ALL CATEGORY "A" FIRE DOORS IN MAIN MACHINERY SPACE. TO THE SATISFACTION OF CLASS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2010
Resolution: Received class report attesting to proper repairs.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 30 October 2010
Resolved
VESSEL'S FIRE CONTROL PLAN DID NOT INDICATE CATEGORY "A" FIRE DOORS IN MAIN MACHINERY SPACE AS SELF-CLOSING. VESSEL'S FIRE CONTROL PLANS MUST BE UPDATED.
Action required: 705 - Other - as specified
Due 29 November 2010
Resolved 6 November 2010
Resolution: Received class report attesting to proper repairs.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 30 October 2010
Resolved
Vessel's SOLAS training manual was outdated and did not provide proper training to the crew on current lifesaving equipment. Training manual contained information on EPIRB and lifejackets that were not currently provided on the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2010
Resolution: Received class report attesting to proper repairs.
Fire Fighting
Issued 8 November 2001
Resolved
UPDATE THE FIRE CONTROL PLAN. SOLAS 74 AMEND II-2/20
Condition: Unknown
Due 1 December 2008
Resolved 22 February 2002
Resolution: Rcvd fax from ABS verifying required updates to fire control plan have been made.
Deck/Cargo
Issued 7 January 1994
Resolved
THERE HAS BEEN A SOFT PATCH PLACED ON THE DECK WATER SEAL DISCHARGE LINE. IT'S LOCATED IN THE PUMP ROOM SECOND DECK PORT SIDE, AT THE BOTTOM OF THE DISCHARGE LINE.
Condition: Unknown
Due 7 January 1994
Resolved 7 January 1994
Documentation
Issued 12 January 1993
Resolved
CORRECT THE VAPOR RECOVERY MANUAL AND OIL TRANSFER PROCEDURES TO INDICATE GRAPH SHOWN IS WORST CASE CARGO AND LIST CARGOES ALONG WITH DATA WHICH SHOWRELATIONSHIP TO WORST CASE CARGO PRIOR TO ENTERING NEXT U.S. PORT.
Condition: Unknown
Due 12 January 1993
Resolved 12 January 1993
Documentation
Issued 12 January 1993
Resolved
THE CLASS SOCIETY APPROVAL LETTER FOR VAPOR RECOVERY SYSTEM MUST BE AMENDEDTO INDICATE SYSTEM MEETS 46 CFR 39.
Condition: Unknown
Due 12 January 1993
Resolved 12 January 1993
Deck/Cargo
Issued 20 December 1988
Resolved
PRIOR TO DEPARTURE FORM THE PORT OF HOUSTON PROVIDE EVIDENCE OF CLASS SOCIETY CERTIFIATION THAT THE LOW LEVEL ALARM ON THE DECK WATER SEAL OPERATES IN THE CARGO CONTROL ROOM.
Condition: Unknown
Due 20 December 1988
Resolved 20 December 1988
Electrical
Issued 20 December 1988
Resolved
PRIOR TO DEPARTURE FROM THE PORT OF HOUSTON PROVIDE EVIDENCE OF CLASS SOCIETY CERTIFICATION THAT EMERGENCY GENERATOR INSTALLATION AUTOMATICALLY TAKES ON ELECTRICAL LOAD IN A LOSS OF POWER SITUATION.
Condition: Unknown
Due 20 December 1988
Resolved 20 December 1988