MAURY USCG vessel records Sign in
← All vessels

NORNA N

NORNA N is a 1981 tank ship. The Coast Guard has recorded 46 inspections since 1984, most recently in October 2008, along with 47 deficiencies and 4 operational controls.

Records from 1984 to 2008. Most recent: inspection, 29 October 2008.

Built
1981
Last inspected
29 October 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8006866 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228252
Flag
PANAMA
—
Maury page id
psix-228252

Inspections, by type

…with no type recorded24
Years with a record 12 calendar years (1984–2008)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it26450 - Convention (Subpart B), Gross Ton
26450 - Simplified, Gross Ton
14367 - Simplified, Net Ton
56322 - Displacement, Ton
46122 - Dead Weight, Ton
14367 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 46

29 October 2008 ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3353494
24 October 2008 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3350914
16 September 2008 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3325844
12 September 2008 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3322622
9 June 2008 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3231802
4 June 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3227544
29 May 2008 Deficiency Check
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3222885
17 May 2008 Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3208923
2 February 2005 COC-TVE Annual · ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2284999
18 November 2003 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1950700
5 November 2003 MARPOL Annex I Examination · Certificate of Compliance
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1942334
19 October 2003 Ballast Water Examination · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1931465
9 August 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 655434
8 August 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 674430
8 August 1994 Deficiency Check · Examination of Repairs
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 866123
1 August 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 47284
1 August 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 368721
1 August 1994 Tank Vessel Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1422442
18 October 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1150585
7 October 1993 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 361688
29 September 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 361510
23 August 1993 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 674429
17 August 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1152849
10 August 1993 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 505846
10 August 1993 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 845606
14 May 1993 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 358380
3 May 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 357991
3 May 1993 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1445981
20 June 1991 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1208277
1 May 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249715
29 April 1991 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 999482
29 January 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 341532
29 January 1991 Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1233892
28 September 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 537172
28 January 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 335064
28 January 1990 Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 918761
9 July 1988 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1207886
22 August 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 318011
22 August 1987 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1000439
22 August 1987 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1308054
26 June 1987 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 462470
14 August 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1001834
13 August 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 310908
23 June 1985 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 511505
6 March 1985 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1288851
10 October 1984 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 472159

Deficiency record · 47

Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 9 June 2008 Resolved
Vessel cargo tanks MARPOL II, Reg 1/IBC 15.19.6, 19.7- Received class report indicating Condition of Class 113 indicating faulty sensors will be replaced at yard period 31JUL08.
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 16 September 2008
Resolution: Received class report clearing above deficiency.
Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 17 May 2008 Resolved
Vessel has authorization to carry flammable cargo diethylene glycol diethyl ether and iaw IBC requires to be inerted. The vessel's inert gas system has not been certified by class. Additionally the main inert line to cargo tanks was found to be holed. Class to attest to proper repair, ops and certification of IGS. 74 SOLAS II-2-5.5.2/IBC 15.4.6 - 23MAY Rec'd class rpt extending def to 28MAY08
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2008
Resolved 17 June 2008
Resolution: Recieved class report from Det Norske Veritas satisfying requirement.
Electrical › Electric Generation Source (service) › Generator
Issued 17 May 2008 Resolved
PSCO noticed vessel's #2 SSDG out of service due to faulty turbo charger. Vessel has three aux generators. While looking at the other generators, PSCO witnessed excessive fuel, water, and oil leaks on #3 SSDG. Vessel only has 1 reliable generator in service. Class to attest to proper repair and ops of both gen sets. 74 SOLAS II-1, Reg 26
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2008
Resolution: Received class report attesting to sat repair/operation.
Engineering › Steering Gear System › Valve
Issued 17 May 2008 Resolved
Steering fluid leaks were noticed in way of #2 steering system bypass valves and directional control valves for both #1 & #2 systems. Excessive accumulation of fluid was noticed under the entire steering system. Class to attest to proper repair of steering system. 74 SOLAS II-1, Reg 29
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2008
Resolved 23 May 2008
Resolution: Received class report attesting to sat repair/operation.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 17 May 2008 Resolved
Vessel is equipped with portable instruments to measure oxygen concentrations, however they do not have the proper span gas to provide for calibration of these instruments. To sat of class. 74 SOLAS II-2-5.7/IBC 13.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2008
Resolution: Span gas was provided per class report
Engineering › Steam System (auxiliary) › Piping
Issued 17 May 2008 Resolved
During the deck walk, PSCO observed several steam leaks which pose a health risk to ship's crew. Two leaks are in 8 inch main steam line flanges in way of #6 Cargo tank area. Additional leaks were noticed forward in the return condensate line. Class to attest to proper repair of all steam leaks. 74 SOLAS (consd) I-11.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2008
Resolution: Steam leaks repaired per class report
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 17 May 2008 Resolved
Several valves (pneumatic and hydraulic) relating to cargo operations were found inoperative. The valves effected were disassembled and rendered to manual operation. Class to attest to proper repair as original intention of valve's operation. 74 SOLAS I Reg 11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2008
Resolved 23 May 2008
Resolution: Cargo pump valves assembled, tested and found in working condition as per class report.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 17 May 2008 Resolved
Vessel's cargo tanks are fitted with a visual and audible Hi-level alarm and over flow system but the system shows numerous faults w/ frequent false alarms. Tanks #5p & 3s continuously sounded although they were not being tested, while tanks #1,2,3 port, slop tanks p&s showed faults. Marpol II, Reg 1/IBC 15.19.6, 19.7 - 23MAY rec'd class rpt which imposed condtion of class until cargo is loaded
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2008
Resolved 20 June 2008
Resolution: Recieved condition of class issued by Det Norske Veritas extending requirement to 31 JUL 08.
Fire Fighting › Fire Main › Condition
Issued 17 May 2008 Resolved
Fire Main that supplies cooling water for electrically powered hydraulic power pack which serves portable cargo pumps leaks water onto the motor controller and wiring creating a safety hazard. Repair leaks and prove proper safe operation to satisfaction of class prior to use of system. 74 SOLAS II-2 Reg 15
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2008
Resolution: Received class report attesting to sat repair/operation.
Lifesaving › Launching Appliances › Davit
Issued 17 May 2008 Resolved
Both the port and stbd launching arrangement for the vessel's survival craft do not operate a intended. The port life boat hand release gear cable parted during operation distorting the pulleys and rollers and the crafts could not be properly recovered due to insufficient air pressure. The davits arms are uneven as a result. To sat of class. 74 SOLAS II-1, Reg 36
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2008
Resolution: Received class report attesting to sat repair/operation.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 May 2008 Resolved
Railings in way of upper catwalk above manifold are wasted and broken. Repair railings to the satisfaction of class. ILLC 66 Annex I Reg 25
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2008
Resolved 23 May 2008
Resolution: Wasted and broken railings renewed to sat of class as per class report.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 17 May 2008 Resolved
Several temperature sensors located in the cargo pump room used to monitor the cargo pump temperature were inoperative or were of the wrong application. Class to attest to proper installation and operation of cargo pump sensors. 74 SOLAS VII Reg 1, IBC 15.21
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 June 2008
Resolved 23 May 2008
Resolution: Temp sensors verified, tested and found in order as per class report.
Deck/Cargo › Cargo Stowage
Issued 6 November 2003 Resolved
Immediatly rectify High O2 in cargo tanks.
Due 6 November 2003
Resolved 6 November 2003
Resolution: High O2 has been rectified in the cargo tanks.
Electrical
Issued 6 November 2003 Resolved
Remove excess electrical wires from the GMDSS battery room.
Due 12 November 2003
Resolved 17 November 2003
Deck/Cargo
Issued 5 November 2003 Resolved
Make permanent repairs to the feedwater wash line to wash tanks. LEGACY COMPONENT DESC: Feed Water Wash Line
Action required: 705 - Other - as specified
Due 6 December 2003
Resolved 17 November 2003
Deck/Cargo › Cargo Stowage
Issued 5 November 2003 Resolved
Immediatly rectify 12 leaking deck penetrations.
Due 6 November 2003
Resolved 6 November 2003
Resolution: The 12 leaking deck penetrations have been rectified.
Navigation › Piloting/Steering › Marine Charts
Issued 5 November 2003 Resolved
Vessel must obtain the proper chart to enter the Port of St. Croix. Vessel must provide prior to enter the Port.
Action required: 15 - Rectify deficiencies by next port
Due 6 November 2003
Resolved 6 November 2003
Resolution: Vessel obtained copy of proper chart to enter the Port of St. Croix.
Accommodation/Occupational Safety › Occupational Safety
Issued 5 November 2003 Resolved
Make permanent repairs to the emergency escape from one of the freezer doors.
Due 6 December 2003
Resolved 17 November 2003
Accommodation/Occupational Safety › Washroom/Toilet
Issued 5 November 2003 Resolved
Make permanent repairs to the vacuume seals on vessels toilets. LEGACY COMPONENT DESC: Toilet
Due 6 December 2003
Resolved 17 November 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 19 October 2003 Resolved
Permanent repairs to be made to vessl's anchor wash piping. Several temporary repairs (lag welds) were identified and observed weaping.
Action required: 705 - Other - as specified
Due 19 November 2003
Resolved 20 October 2003
Resolution: Class report received, reviewed and approved.
Construction/Loadline › Hull
Issued 19 October 2003 Resolved
Hull plating STBD side engine room has numerous indents in plate located aft side of engine room outboard of boiler. Aproximatly 7m from main deck and 12m from stern of vessel. Class Society Surveyor to attest to hull integrity at location and submit permanent repair proposal to congizant [name withheld]: Hull Plating
Action required: 705 - Other - as specified
Due 19 November 2003
Resolved 20 October 2003
Resolution: Class report received, reviewed and approved.
Lifesaving › Launching Appliances
Issued 19 October 2003 Resolved
Port Lifeboat brake not working when tested. Class Society Surveyor to attest to proper repair and operation of brake system prior to departure from the Port of Baltimore. Report from Class to be received, reviewed and approved by COTP Baltimore prior to permission granted to depart. LEGACY COMPONENT DESC: Winch Brake
Action required: 705 - Other - as specified
Due 19 October 2003
Resolved 20 October 2003
Resolution: Class report received, reviewed and approved.
Deck/Cargo
Issued 1 August 1994 Resolved
VESSEL'S CARGO WAS NOT IN COMPLIANCE WITH IOPP IN THAT CARGO ON BOARD WAS CONDENSATE WHICH IS A CRUDE OIL. IOPP SPECIFIED THAT THE VESSEL WAS A "PRODUCT" CARRIER ONLY. CONDENSATE IS NOT A PRODUCT.
Condition: Unknown
Due 10 August 1994
Resolved 7 September 1994
Construction/Loadline
Issued 1 August 1994 Resolved
Prior to departing from Corpus Christi, Texas, make repairs to No. 2 starboard fuel tank and complete internal examination of No 10 starbaord slop tank for damage/repairs assessment as described in LRS survey report no 410273 dated 01AUG94
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Unknown
Issued 1 August 1994 Resolved
Prior to departing from Corpus Christi, Texas, remove oil from bilge of emergency fire pump room.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Deck/Cargo
Issued 10 August 1993 Resolved
PRIOR TO RETURN TO NEXT U.S. PORT, PROVIDE CLASS SOCIETY ATTESTATION OF PROPER OPERATION AND MATERIAL CONDITION OF ALL PRESSURE VACUUM (P/V) VALVES.
Condition: Unknown
Due 10 August 1993
Resolved 10 August 1993
Construction/Loadline
Issued 10 August 1993 Resolved
PRIOR TO RETURN TO NEXT U.S. PORT, PROVIDE CLASS SOCIETY ATTESTATION OF MATERIAL CONDITION OF ALL CARGO/SLOP TANK CLEANING HATCH COVERS (BUTTERWORTH COVERS) AND SEALING SURFACES.
Condition: Unknown
Due 10 August 1993
Resolved 10 August 1993
Navigation
Issued 14 May 1993 Resolved
CHART 25641 FOR AREA TRANSITED NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 18 October 1993
Resolved 18 October 1993
Navigation
Issued 3 May 1993 Resolved
LARGE SCALE CHART FOR AREA TRANSITTED NOT CURRENTLY CORRECTED. CHART #2567716TH EDITION 1983 HAD NO CORRECTIONS.
Condition: Unknown
Due 18 October 1993
Resolved 18 October 1993
Navigation
Issued 3 May 1993 Resolved
U.S. COAST PILOT VOL. V 22ND EDITION NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 14 October 1993
Resolved 14 October 1993
Deck/Cargo
Issued 3 May 1993 Resolved
Remove wooden plugs from scuppers on deck and replace with mechanical closures.
Condition: Unknown
Due 3 May 1993
Resolved 3 May 1993
Navigation
Issued 29 January 1991 Resolved
U.S. COAST PILOT VOL7 25ED 1989 NOT CURRENTLY CORRECTED. MISSING NOTICE TO MARINERS AS FOLLOWS:1990-7,10,11,15,21,24,33,35,37,39,40.[AUTH:33USC1223_x001C_ CFR:33CFR164.33(a)(2)(i);PEN SITE:33USC1232(a)(1);PEN AMT:$25,000.00]_x001C_
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Navigation
Issued 29 January 1991 Resolved
ADMIRALTY LIGHT LIST VOL G,1990 NOT CURRENTLY CORRECTED. MISSING ADMIRALTY NOTICE TO MARINERS AS FOLLOWS:1990-29,31,32,35,45,48.[AUTH:33USC1223;CFR: 33CFR164.33(b);PEN SITE:33USC1232(a)(1);PEN AMT:$25,000.00]
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Deck/Cargo
Issued 29 January 1991 Resolved
IGS piping has fiberglass patch. No apparent leak.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Deck/Cargo
Issued 29 January 1991 Resolved
Stainless steel cargo piping on deck has several soft patches. No apparent leaks.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Deck/Cargo
Issued 29 January 1991 Resolved
Return piping for IGS deck seal wasted to the point of leaking. Temporary repairs made with soft patch.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Deck/Cargo
Issued 29 January 1991 Resolved
Cargo piping in pumproom repaired with soft patches.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Fire Fighting
Issued 29 January 1991 Resolved
Deck wash piping fed directly by firemain was wasted and leaking.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Electrical
Issued 29 January 1991 Resolved
Ends of conduit for closed guaging wire were not sealed.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Navigation
Issued 28 January 1990 Resolved
33CFR164.33(A)(1)(II) - THE MARINE CHARTS ON BOARD THE VESSEL USED TO TRANSIT THE AREA (BOSTON HARBOR AND APPROACHES) WERE NOT CURRENTLY CORRECTED (NOAA CHARTS 13267, 13270 AND 13272).
Condition: Unknown
Due 29 January 1990
Resolved 28 January 1990
Navigation
Issued 28 January 1990 Resolved
33CFR164.33(A)(2)(II) - THE VESSEL DID NOT HAVE ON BOARD A CURRENTLY CORRECTED COPY OF, OR APPLICABLE CURRENTLY CORRECTED EXTRACT FROM, THE COAST GUARD LIGHT LIST FOR THE AREA TRANSITED (BOSTON HARBOR AND APPROACHES)(THE VESSEL HAD ON BOARD AN UNCORRECTED 1988 LIGHT LIST).
Condition: Unknown
Due 29 January 1990
Resolved 28 January 1990
Navigation
Issued 28 January 1990 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 29 January 1990
Resolved 28 January 1990
Navigation
Issued 28 January 1990 Resolved
THREE AMERICAN CHARTS WERE NOT UP TO DATE.
Condition: Unknown
Due 28 January 1990
Resolved 28 January 1990
Navigation
Issued 28 January 1990 Resolved
COAST PILOT AND LIGHT LIST NOT CORRECTED TO DATE.
Condition: Unknown
Due 28 January 1990
Resolved 28 January 1990
Navigation
Issued 9 July 1988 Resolved
VESSEL NEED TO UPDATE ALL CHARTS TO DELAWARE RIVER.33CFR164.33 PRIOR TO RETURNING TO THE PORT OF PHILADELPHIA.
Condition: Unknown
Due 9 July 1988
Resolved 9 July 1988
Deck/Cargo
Issued 22 August 1987 Resolved
INERT GAS SYSTEM NOT OPERATING AS REQUIRED TO MAINTAIN AN INERT ATMOSPHERE IN CARGO TANKS. NO INERT ATMOSPHERE IN VESSEL'S CARGO TANKS.
Condition: Unknown
Due 22 August 1987
Resolved 22 August 1987
Navigation
Issued 22 August 1987 Resolved
CHARTS 12327 AND 12333 (84 EDITIONS) ON BOARD NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 22 August 1987
Resolved 22 August 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.