MAURY USCG vessel records Sign in
← All vessels

MOSTOLES

MOSTOLES is a 1981 freight ship. The Coast Guard has recorded 44 inspections since 1985, most recently in February 2005, along with 32 deficiencies and 3 operational controls.

Records from 1985 to 2005. Most recent: inspection, 28 February 2005.

Built
1981
Last inspected
28 February 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8006921 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228253
Flag
PANAMA
—
Maury page id
psix-228253

Inspections, by type

…with no type recorded22
Years with a record 15 calendar years (1985–2005)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it44985 - Convention (Subpart B), Gross Ton
44985 - Regulatory (Subpart C or D), Gross Ton
23932 - Convention (Subpart B), Net Ton
23932 - Regulatory (Subpart C or D), Net Ton
92761 - Displacement, Ton
75395 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 44

28 February 2005 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2300551
22 February 2005 MARPOL Annex V Examination · Random ISPS/MTSA/PSC · Ballast Water Examination · COC-TVE Annual · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2296664
18 February 2005 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2295013
21 December 2004 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2263233
17 December 2004 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2261172
13 December 2004 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2257992
10 December 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2256823
9 December 2004 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2256056
8 December 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2255732
23 July 2004 ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2142343
16 February 2004 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2007162
13 August 2002 Annual Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1660957
1 May 2002 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1613489
2 August 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 292328
2 August 2001 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1069897
4 March 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 287993
7 August 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 280789
7 March 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 275458
8 July 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 430382
8 July 1999 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1097726
8 December 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 423430
4 July 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 417450
4 July 1998 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1128119
17 July 1994 Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1396157
10 January 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 497938
3 May 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1448431
26 April 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 100759
14 April 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 357588
14 April 1993 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 838823
13 April 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 357613
20 April 1992 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1255639
3 October 1991 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 346468
15 June 1991 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1038288
21 March 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 342492
19 March 1991 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1242434
20 April 1990 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 907216
17 January 1990 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 451329
1 August 1989 MARPOL Annex II Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1203610
11 April 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 329620
11 April 1989 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 894136
15 January 1987 Certificate of Compliance
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1315137
14 January 1987 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 525145
10 September 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 304153
28 August 1985 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 515890

Deficiency record · 32

Communications › Alarms/Indicators › General Alarm
Issued 22 February 2005 Resolved
General alarm system can not be heard on aft mooring deck and not loud enough in the engine room to be heard over operational machinery. Increase the alarm tones to ensure that the alarm may be heard as required by LSA Code 7.2.1.2 to the satisfaction of Class by 22 MAR 05.
Action required: 705 - Other - as specified
Due 22 March 2005
Resolved 28 February 2005
Resolution: Received report from Det Norske Veritas showing that all alarms are now operating properly.
Fire Fighting › Structural - B Class Divisions › Doors
Issued 22 February 2005 Resolved
Self-closing door to engine room on upper deck will not self-close. Demonstrate proper closure of door under normal condition to the satisfaction of Class by 22 MAR 05.
Action required: 705 - Other - as specified
Due 22 March 2005
Resolved 22 February 2005
Resolution: Engineers adjusted door closure and engine room ventilation. Door properly self-closes, deficiency cleared while onboard.
Deck/Cargo › Cargo Stowage › General
Issued 10 December 2004 Resolved
On December 9, 2004 during an exam the marine inspectors found that the LEL readings were 100% in the ships No.1 Stool Space. The vessel must address this issue prior to entry into the Port of New York. 12DEC04- Marine chemist report received, COTP Order # 125-04 is hereby rescinded.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2004
Resolution: Report # M34892 was received from certified marine chemist # C634 claiming that the elevated levels of LEL in this stool space was from an excessive amount of dead marine life decomposing and gassing off. Based on this report this def is cleared.
Documentation › Logs/Records › Oil Record Book
Issued 9 December 2004 Resolved
OIl recored book entries for HFO purifier sludge tanks foudn with inaccurate entries. This corrected to satisfaction of USCG prior to departing the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 9 December 2004
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 9 December 2004 Resolved
MSD wasted and non functional. This to be corrected to satisfaction of class prior to using this device in U.S. waters. Ship to be on full retention while in U.S. waters until repairs are completed.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 February 2005
Resolution: CLEARED VIA CLASS REPORT
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 9 December 2004 Resolved
Emergency generator's secondary means of starting is non-functional. This to be corrected to satisfaction of DNV.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 17 December 2004
Resolution: DNV certified this has been corrected to their satisfaction via class report dated 12-16-2004.
Deck/Cargo › Cargo Stowage › General
Issued 9 December 2004 Resolved
Ship's cargo tanks overloaded past 98.5% in violation of 33CFR155.775. Ship's DPA to address this to prevent this from occcuring in future with written plan sent to USCG.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 12 December 2004
Resolution: The companies DPA has ammended the ship''s Oil Transfer Procedures with addtional loading requirments for ship''s personnel to follow with regard to temperature variances in the load port.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 9 December 2004 Resolved
98% high level alarms do not work. This to be corrected to satisfaction of class prior to loading a liquid petroleum cargo in U.S. waters.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 17 December 2004
Resolution: DNV certified this has been corrected to their satisfaction via class report dated 12-16-2004.
Construction/Loadline › Hull › Stool
Issued 9 December 2004 Resolved
6 out of 8 of the vessel's stool spaces, the midships cofferdam and 3 ballast tanks found with LEL ranging from 100% to various other levels. This condition to be gas freed and permanently corrected to satisfaction of DNV and USCG at sea prior to conducting cargo operations in U.S. waters.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 12 December 2004
Resolution: Marine Chemist report # M34892 was recieved claiming elevated levels of LEL found in all non-cargo spaces were a result of excessive dead marine life in bottoms of stool and ballast tanks. Tanks were vented and certified gas free this date.
Deck/Cargo › Holds/Tanks
Issued 16 February 2004 Resolved
Found vapor leak coming from the hatch cover of CT #4 LEGACY COMPONENT DESC: Hatch Cover
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 February 2004
Resolved 19 February 2004
Resolution: Received class report from Det Norske Veritas (DNV) dated 17 February 2004 stating, Cause of the vapor leak was a loose shim. The shim has been replace and the hatch covers have been re-secured. There appears to be no visual signs of vapor leakage from
Deck/Cargo › Inert Gas System
Issued 16 February 2004 Resolved
Ship is to have vsl class society test IGS operational status
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 February 2004
Resolved 19 February 2004
Resolution: Received class report from Det Norske Veritas (DNV) dated 17 February 2004 stating, The inert gas system was tested in the presence of a class surveyor and appears to be in good order.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 12 August 2002 Resolved
Vessel is to provide calibration (span) gas for the portable explosive meters IAW SOLAS 74, Chapter II-2, Regulation 59/4.4.1 prior to departure from port. LEGACY COMPONENT DESC: Combustible Gas Indicator
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2002
Resolved 14 August 2002
Resolution: Received delivery receipt for gas.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 12 August 2002 Resolved
Vessel is to make all new electrical installations in the cargo pumproom explosion proof IAW SOLAS 74, Chapter II-1, Regulation 45/10 prior to departure from port. LEGACY COMPONENT DESC: Pumproom
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2002
Resolved 14 August 2002
Resolution: Received class report attesting to repairs.
Deck/Cargo › Holds/Tanks
Issued 12 August 2002 Resolved
Vessel is to make permanent repairs to the leaking hydraulic line in way of #2 cargo tank/hatch-port side and provide class attestation of said repairs prior to departure from port IAW SOLAS 74, Chapter II-2, Regulation 59. LEGACY COMPONENT DESC: Hatch Cover
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2002
Resolved 14 August 2002
Resolution: Received class report confirming that leak was from spring line winch vice hydraulic hatch cover line. Condition of class issued to vessel and requirement cleared based upon this.
Lifesaving › Rescue Boat
Issued 12 August 2002 Resolved
Vessel is to provide class approval of temporary repairs made in way of damaged sections on the hull of the rescue boat prior to departure from port IAW SOLAS 74, Chapter III, Regulation 19 LEGACY COMPONENT DESC: Hull (rigid)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2002
Resolved 14 August 2002
Resolution: Repairs/modifications to the rescue boat hull approved by class.
Lifesaving › Immersion Suits
Issued 12 August 2002 Resolved
Vessel is to provide an additional immersion suit onboard prior to departure from port IAW SOLAS 74, Chapter III, Regulation 27.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2002
Resolved 14 August 2002
Resolution: Received receipt for new immersion suit.
Lifesaving › Lifeboat Equipment
Issued 12 August 2002 Resolved
Vessel is to replace the first aid kits in both lifeboats prior to departure from port IAW SOLAS 74, Chapter III, Regulation 41. LEGACY COMPONENT DESC: First Aid Kit
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2002
Resolved 14 August 2002
Resolution: Received receipt for new first aid kits.
Lifesaving › Lifeboat
Issued 12 August 2002 Resolved
Vessel is to repair and prove proper operation of the fire protection system in the port lifeboat to the satisfaction of class surveyor prior to departure from port IAW SOLAS 74, Chapter III, Regulation 19. LEGACY COMPONENT DESC: Fire Protection (water spray system)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2002
Resolved 14 August 2002
Resolution: Fire protection system repaired and class report provided.
Lifesaving › Launching Appliances
Issued 12 August 2002 Resolved
Vessel is to repair and prove proper operation of the forward limit switch on the port lifeboat davit prior to departure from port IAW SOLAS 74, Chapter III, Regulation 19. LEGACY COMPONENT DESC: Davit
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2002
Resolved 14 August 2002
Resolution: Limit switch repaired and class report provided.
Lifesaving › Lifeboat
Issued 12 August 2002 Resolved
Vessel is make permanent repairs to the bottom side grab rails on the port/starboard lifeboats and provide class attestation of said repairs prior to departure from port IAW SOLAS 74, Chapter III, Regulation 19. LEGACY COMPONENT DESC: Handholds/Handrails
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2002
Resolved 14 August 2002
Resolution: Grap rails repaired and class report provided.
Lifesaving › Launching Appliances
Issued 12 August 2002 Resolved
Vessel is to end for end the lifeboat davit falls or provide class approval of current installation prior to departure from port IAW SOLAS 74, Chapter III, Regulation 19. LEGACY COMPONENT DESC: Falls
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2002
Resolved 14 August 2002
Resolution: Condition of class placed on vessel to have falls replaced at drydock in February 2003. Requirement cleared based upon this condition of class.
Lifesaving › Lifeboat
Issued 12 August 2002 Resolved
Vessel is to place retroreflective tape on the bottom sides of both lifeboats prior to departure from port IAW SOLAS 74, Chapter III, Regulation 30. LEGACY COMPONENT DESC: Markings
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2002
Resolved 14 August 2002
Resolution: Retro tape placed on bottoms of boats.
Deck/Cargo
Issued 2 August 2001 Resolved
Atmospheric valve indicator in engine room for IGS system inoperable. Repair prior to 10SEP01.
Condition: Unknown
Due 8 August 2001
Resolved 8 August 2001
Deck/Cargo
Issued 2 August 2001 Resolved
Prove proper operation of independent PV cargo tank valves to the satisfaction of class surveyor.
Condition: Unknown
Due 8 August 2001
Resolved 8 August 2001
Deck/Cargo
Issued 4 July 1998 Resolved
VESSEL DID NOT HAVE AN APPROVED VAPOR RECOVERY SYSTEM.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Deck/Cargo
Issued 19 March 1991 Resolved
PROVE OPERATION OF THE CARGO PUMP EMERGENCY SHUTDOWN PRIOR TO THE NEXT U.S.VOYAGE.
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Deck/Cargo
Issued 19 March 1991 Resolved
SERVICE THE STOP VALVES IN THE NUMBERS 3,5,& 7 CARGO TANK INERT GAS BRANCH LINES PRIOR TO THE CARRIAGE OF FLAMMABLE OR COMBUSTIBLE CARGOES IN U.S. WATERS.
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Deck/Cargo
Issued 19 March 1991 Resolved
SERVICE THE NUMBER 1 & 5 CARGO TANK P/V VALVES PRIOR TO THE NEXT U.S. VOYAGE.
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Deck/Cargo
Issued 19 March 1991 Resolved
REMOVE THE FLAMMABLE AND COMBUSTIBLE MATERIALS FROM THE FORWARD DECK LOCKEROR INSTALL A FIXED FIREFIGHTING SYSTEM PRIOR TO THE CARRIAGE OF FLAMMABLE OR COMBUSTIBLE CARGOES IN U.S. WATERS.
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Deck/Cargo
Issued 19 March 1991 Resolved
PROVE OPRATION OF THE INERT GAS SYSTEM PRIOR TO THE CARRIAGE OF FLAMMABLE OR COMBUSTIBALE CARGOES IN U.S. WATERS.
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Navigation
Issued 15 January 1987 Resolved
UPDATE CHARTS 12214, 12304, 12311, AND 12312 PRIOR TO DEPARTURE FROM THE PORT OF PHILADELPHIA.
Condition: Unknown
Due 15 January 1987
Resolved 15 January 1987
Deck/Cargo
Issued 15 January 1987 Resolved
MAKE PERMANENT REPAIRS TO INERT GAS OXYGEN RECORDER PRIOR TO NEXT U.S. PORT
Condition: Unknown
Due 15 January 1987
Resolved 15 January 1987

Ownership record