ALEX P

ALEX P is a 1978 freight ship. The Coast Guard has recorded 16 inspections since 1984, most recently in August 2002, along with 33 deficiencies and 4 operational controls.

Records from 1984 to 2002. Most recent: operational control imposed, 2 August 2002.

Built
1978
Last inspected
2 August 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7703558 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228292
Flag
MALTA
—
Maury page id
psix-228292

Inspections, by type

…with no type recorded14
Years with a record 11 calendar years (1984–2002)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it24622 - Dead Weight, Ton
14965 - Regulatory (Subpart C or D), Gross Ton
8007 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 16

2 August 2002 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1655983
6 June 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1627612
23 May 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1620350
24 May 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 416375
5 November 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 354506
31 March 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 342834
17 March 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 335894
8 February 1989 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 328314
18 June 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 523611
16 August 1987 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 317895
18 March 1987 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 451324
2 August 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 310527
25 March 1986 Type not recorded
No type recorded · COTP NEW LONDON · USCG Northeast District (CGD-NE) · Activity 482649
2 April 1985 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 301324
27 February 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 516786
17 May 1984 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 444282

Deficiency record · 33

Engineering › Generator (propulsion/auxiliary-electric)
Issued 2 August 2002 Resolved
#1 generator has excessive fuel leaks from the high pressure fuel pumps. Fix all leaks on the #1 generator to the satisfaction of the issuing authority of the safety construction cert, prior to departing port. solas 74/78 I-II / II-1 reg 43.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2002
Resolved 6 August 2002
Resolution: Rcvd class report attesting to repairs of leaks to generator.
Fire Fighting › Fire Main
Issued 2 August 2002 Resolved
Rupture in fire main piping. Renew rupture fire main piping to the satisfaction of the issuing authority of safety equipment cert, prior to departing port. solas 74/78 II-2 reg 4 LEGACY COMPONENT DESC: Material
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2002
Resolved 6 August 2002
Resolution: Rcvd class report attesting to the renewal of the burst firemain piping.
Operations/Management › Vessel Safety Management
Issued 2 August 2002 Resolved
Questioned the validity of vsl's safety management system. Issuing authority of the ISM cert, provide attesting documentation that the SMS is adequate in way of engine room maintenances, prior to departing port. solas 74/78 IX / ISM CODE #10 LEGACY COMPONENT DESC: Maintenance of Ship/Equipment
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2002
Resolved 6 August 2002
Resolution: Rcvd class report attesting to documentation that the SMS is adequate in way of engine room maintenances.
Pollution Prevention/Response › Prevention Equipment
Issued 2 August 2002 Resolved
Oily water separator control module and sensing module is inoperable. Repair and calibrate to the satisfaction of the issuing authority of the IOPP cert Repair prior to departing port marpol annex 1 reg 16.5 LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2002
Resolved 8 August 2002
Resolution: Rcvd class report attesting to renewal of the control module and sensing module. Rcvd class report attesting to calibration of OWS unit.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 2 August 2002 Resolved
Temporary installation of portable generator. Request issuing authority of the safety equipment cert, provide to the coast guard attesting information on the installation, fire protection and safety measure for the temporary generator on deck.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2002
Resolved 6 August 2002
Resolution: Rcvd class report attesting to fire protection and safety measure for the temporary generator on deck
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 24 May 2002 Resolved
CREW ACCOMMODATIONS INFESTED WITH INSECTS. LEGACY COMPONENT DESC: Area Per Person
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2002
Accommodation/Occupational Safety › Washroom/Toilet
Issued 24 May 2002 Resolved
SANITARY WATER IN CREW ACCOMMODATIONS SUPPLY AND DRAINS NOT CONNECTED. LEGACY COMPONENT DESC: Washbasin
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 24 May 2002 Resolved
HOSPITAL SPACE TOILET FAILED TO FUNCTION. LEGACY COMPONENT DESC: Hospital Space
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2002
Engineering › Feedwater/Condensate Water System
Issued 24 May 2002 Resolved
B/F BALLEST PUMP SHAFT PACKING LEAKING .
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2002
Fire Fighting › Fire Pumps
Issued 24 May 2002 Resolved
EMERGENCY FIRE PUMP FAILED TO TAKE SUCTION.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2002
Communications › Radio Communications
Issued 24 May 2002 Resolved
EMERGENCY BACK UP BATTERIES NEED TO BE REPLACED LEGACY COMPONENT DESC: Emergency Source of Power
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2002
Lifesaving › Launching Appliances
Issued 24 May 2002 Resolved
PORT SIDE LIFEBOAT DEADMAN BRAKE FAILED TO OPERATE. LEGACY COMPONENT DESC: Release Mechanism
Due 24 August 2002
Resolved 28 May 2002
Lifesaving › Lifeboat
Issued 24 May 2002 Resolved
STBD LIFEBOAT FAILED TO LOWER DUE TO INABILITY TO REMOVE THE FWD GRIP. LEGACY COMPONENT DESC: Embarkation/Disembarkation Capabilities
Due 24 August 2002
Resolved 28 May 2002
Lifesaving › Lifeboat
Issued 24 May 2002 Resolved
STBD LIFEBOAT FALLS REQUIRE RENEWAL DUE TO DAMAGE DURING REPAIRS. LEGACY COMPONENT DESC: Embarkation/Disembarkation Capabilities
Due 24 August 2002
Resolved 28 May 2002
Lifesaving › Lifeboat
Issued 24 May 2002 Resolved
LIFEBOAT RADIOS DONOT WORK. NEEDS NEW BATTERIES.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2002
Lifesaving › Lifejacket/PFD (Type V)
Issued 24 May 2002 Resolved
LIFEJACKET LIGHTS DO NOT WORK. LEGACY COMPONENT DESC: Lights
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2002
Lifesaving › Lifeboat
Issued 24 May 2002 Resolved
STBD SIDE EMBARKATION LADDER PARTED WHEN DEPLOYED. LEGACY COMPONENT DESC: Boarding Ladder
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2002
Deck/Cargo
Issued 24 May 2002 Resolved
HOLE IN DECK IN FRONT OF DECKHOUSE BESIDE ENGINE ROOM HATCH.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2002
Deck/Cargo › Holds/Tanks
Issued 24 May 2002 Resolved
FLAME SCREENS DETERIATED OR MISSING. LEGACY COMPONENT DESC: Ventilation Exhaust Outlet
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2002
Documentation › Logs/Records
Issued 24 May 2002 Resolved
DECK OIL SPILL NOT RECORDED IN ORB LEGACY COMPONENT DESC: Oil Record Book
Due 24 May 2002
Resolved 28 May 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 24 May 2002 Resolved
STRETCHER DRY-ROTTED AND NOT FUNCTIONAL. LEGACY COMPONENT DESC: Medicine Chest
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2002
Navigation › Piloting/Steering
Issued 24 May 2002 Resolved
VESSEL DOES NOT HAVE REQUIRED CHARTS TO ENTER DELAWARE BAY. LEGACY COMPONENT DESC: Marine Charts
Due 24 May 2002
Resolved 28 May 2002
Documentation › Certificates/Documents
Issued 24 May 2002 Resolved
VESSEL DOES NOT HAVE A DOC WITH A CURRANT ENDORSEMENT. LEGACY COMPONENT DESC: Document of Compliance (ISM)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 24 May 2002 Resolved
DEAD END WIRING IN RADIO ROOM AFT OF PILOT HOUSE. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 24 August 2002
Resolved 28 May 2002
Lifesaving
Issued 24 May 2002 Resolved
EPIRB NOT STOWED FLOATFREE, HYDROSTATIC RELEASE STOWED IN PILOT HOUSE
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2002
Lifesaving
Issued 24 May 1998 Resolved
REPAIR WASTED HANDRAIL BOTTOM OF LIFEBOATS. CORRECT TO SATISFACTION OF CLASS SOCIETY NO LATER THAN 24JUN98.
Condition: Unknown
Due 24 June 1998
Resolved 23 May 2002
Electrical
Issued 24 May 1998 Resolved
REPAIR FUSE BOX TO EMERGENCY FIRE PUMP STARTER TO SATISFACTION OF CLASS SOCIETY PRIOR TO 24JUN98.
Condition: Unknown
Due 24 June 1998
Resolved 23 May 2002
Lifesaving
Issued 24 May 1998 Resolved
REPAIR WASTED HANDRAILS THROUGH OUT SHIP TO SATISFACTION OF CLASS PRIOR TO 24JUN98.
Condition: Unknown
Due 24 June 1998
Resolved 23 May 2002
Lifesaving
Issued 24 May 1998 Resolved
REMOVE CHAIN FROM FOWARD LIFERAFT PRIOR TO DEPARTURE OF BOARDING TEAM.
Condition: Unknown
Due 24 May 1998
Resolved 27 May 1998
Engineering
Issued 24 May 1998 Resolved
INSTALL PROPER FLAME SCREENS ON FUEL VENTS. CORRECT TO SATISFACTION OF CLASS PRIOR TO 24JUN98.
Condition: Unknown
Due 24 June 1998
Resolved 23 May 2002
Navigation
Issued 24 May 1998 Resolved
PROVIDE CURRENT COPY OF COAST PILOT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 24 May 1998
Resolved 23 May 2002
Electrical
Issued 24 May 1998 Resolved
REPAIR CORRODED CONDUIT ELECTRICAL WIRE PIPES THROUGH OUT SHIP. CORRECT TO SATISFACTION OF CLASS SOCIETY PRIOR TO 24JUN98.
Condition: Unknown
Due 24 June 1998
Resolved 23 May 2002
Fire Fighting
Issued 24 May 1998 Resolved
PROPERLY REPAIR EXHAUST LEAK FROM EMERGENCY FIRE PUMP ENGINE. CORRECT TO SATISFACTION OF CLASS SOCIETY PRIOR TO 24JUN98.
Condition: Unknown
Due 24 June 1998
Resolved 24 May 1998