Records from 1984 to 1998. Most recent: inspection, 15 January 1998.
Lifesaving
Issued 15 January 1998
Resolved
Provide 4kg lifebuoys on port and stbd bridge wings. SOLAS (AMENDED) Reg III/31.7._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 February 1998
Resolved 20 February 1998
Documentation
Issued 15 January 1998
No resolution recorded
Provide written company action plan with policies and procedures for vesselfamiliarization. STCW I-14, A-I-14. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 January 1998 — due date passed with no resolution recorded
Documentation
Issued 15 January 1998
No resolution recorded
Provide proof of crew training and vessel familiarization. STCW VI-1, A- VI-1. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 January 1998 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 15 January 1998
Resolved
Remove oil residue and ash in vent trunk above diesel oil fired stove in galley. SOLAS 74 (AMENDED) _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 February 1998
Resolved 20 February 1998
Navigation
Issued 15 January 1998
Resolved
Provide current charts for Honolulu, HI. 33CFR164.33. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 February 1998
Resolved 20 February 1998
Engineering
Issued 15 January 1998
Resolved
Perform hydrostatic test on all bunker piping in accordance with 33CFR156.170(2). Prior to bunkering in the U.S.
Condition: Unknown
Due 20 February 1998
Resolved 20 February 1998
Navigation
Issued 15 January 1998
Resolved
Provide proper log entries for pe-arrival and departure tests, steering gear test/drills and testing the general alarm in accodance with 33CFR164 and SOLAS 74 AMENDED III 19.6.3.
Condition: Unknown
Due 20 February 1998
Resolved 20 February 1998
Construction/Loadline
Issued 15 January 1998
No resolution recorded
Conduct permanent repairs to the hull fractures and wastage located in the trunk spaces between #1 & #2 cargo holds at frames 156-157, port and stbd. Repairs to be conducted to the satisfaction of Class prior to entering nextU.S. port. Temporary repairs conducted at Honolulu 3/98.
Condition: Unknown
Due 18 March 1998 — due date passed with no resolution recorded
Construction/Loadline
Issued 15 January 1998
Resolved
Remove bilge pump direct overboard discharge capability. MARPOL 73/78 II, Reg 9. Correct prior to departure of Honolulu, Hi.
Condition: Unknown
Due 23 January 1998
Resolved 23 January 1998
Documentation
Issued 15 January 1998
No resolution recorded
Provide flag state approval for all officers licenses not issued from Singapore. STCW I/10. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 January 1998 — due date passed with no resolution recorded
Electrical
Issued 15 January 1998
Resolved
Provide remote stop switch for electric stove in galley. SOLAS (AMENDED)II-1 Reg 10 _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 February 1998
Resolved 20 February 1998
Unknown
Issued 15 January 1998
Resolved
Prove completion of all class and statutory surveys. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 January 1998
Resolved 3 April 1998
Documentation
Issued 15 January 1998
Resolved
Provide adequate manning to the deck department in accordance with the safemanning document. SOLAS 74(AMENDED) Reg V/13a. Correct prior to departureof Honolulu, HI._x001C_
Condition: Unknown
Due 23 January 1998
Resolved 23 January 1998
Documentation
Issued 11 November 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Navigation
Issued 11 November 1997
Resolved
VESSEL FAILED TO CONDUCT AND LOG QUARTLY STEERING DRILLS AND CONDUCT STEERING TESTS PRIOR TO ENTERING PORT.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Navigation
Issued 11 November 1997
Resolved
PROVIDE COAST PILOT VOL.5 OR BA 69A FOR TAMPA AREA. VSL/CREW USING FOREIGN EQUIVALENTS.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Navigation
Issued 11 November 1997
Resolved
PROVIDE CURRENT LIGHT LIST VOL.III. OR BA VOL J REQUUIRED FOR TAMPA. VSL/CREW USING BA CHARTS AND PUBS.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Lifesaving
Issued 11 November 1997
Resolved
STARBOARD LIFEBOAT HAND RAILS BROKEN.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Lifesaving
Issued 11 November 1997
Resolved
PROVIDE 4 CARTRIDGES FOR LINE THROWING GUN.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Lifesaving
Issued 11 November 1997
Resolved
PROVIDS ONE SMOKE/LIGHT FOR BRIDGEWING.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Lifesaving
Issued 11 November 1997
Resolved
PORT LIFEBOAT SEAT BROKEN.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Lifesaving
Issued 11 November 1997
Resolved
REPLACE 2 LIFERINGS ON BRIDGEWING AND ONE LIFERING ON DECK BELOW BRIDGE.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Lifesaving
Issued 11 November 1997
Resolved
PROVIDE LIGHTS FOR LIFERINGS ACCORDING TO SAFETY EQUIPMENT CERTIFICATE.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Fire Fighting
Issued 11 November 1997
Resolved
FIRE CONTROL PLAN DOES NOT SHOW LOCATION OF INTERNATIONAL SHORE CONNECTION.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Accommodation/Occupational Safety
Issued 11 November 1997
Resolved
PROVIDE INVOICE FOR PROCUREMENT OF REQUIRED MEDICAL SUPPLIES AND REMOVE EXPIRED DRUGS FROM VESSEL.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Accommodation/Occupational Safety
Issued 11 November 1997
Resolved
MAKE PERMANENT REPAIRS TO DAMAGED ACCOMODATION LADDER AND DEMOPNSTRATE PROPER OPERATION.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Accommodation/Occupational Safety
Issued 11 November 1997
Resolved
REMOVE LAUNDRY MACHINE AND RETURN HOSPITAL SPACE TO ITS INTENDED CONDITION.REMOVE WATER ON DECK AND CREW CLOTHING.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Fire Fighting
Issued 11 November 1997
Resolved
FLAG STATE REVIEW EXISTING GALLEY FIRE HAZZARD (DIESEL OIL FIRED STOVE WITHEXCESSIVE OIL RESIDUE / ASH IN VENT TRUNK AND THROUGHOUT AFT FIREWALL OF GALLEY.
Condition: Unknown
Due 16 January 1998
Resolved 16 January 1998
Documentation
Issued 11 November 1997
Resolved
PROVIDE A GARBAGE LOG FOR VESSEL. NO RECORDS OF DISPOSAL. GARBAGE STORED OUTSIDE OF RAILING OF SHIP AND GARBAGE CONTAINERS WERE NOT COVERED.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Lifesaving
Issued 11 November 1997
Resolved
CLASS SURVEYOR TO VERIFY SAFETY AND ADAQUACY OF BOTH PORT AND STARBOARD LIFEBOATS, LIFEBOAT DAVITS, FALLS AND ASSOCIATED EQUIPMENT PRIOR TO FIRE AND BOAT DRILLS BY U.S. COAST GUARD.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Engineering
Issued 11 November 1997
Resolved
DEMONSTRATE PROPER OPERATION OF OILY WATER SEPARATOR AND ALARM/SHUTDOWN.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Engineering
Issued 11 November 1997
Resolved
REMOVE COMBUSTIBLES FROM DEISEL OIL PURIFIER ROOM.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Lifesaving
Issued 11 November 1997
Resolved
REMOVE EXCESSIVE OXYGEN AND ACETYLINE COMPRESSED GAS BOTTLES AND PROPERLY STOW REMAINING BOTTLES IN METAL RACKS.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Navigation
Issued 11 November 1997
Resolved
CONDUCT AND LOG PRE-ARRIVAL TESTS. VSL/CREW DID NOT LOG OR CONDUCT PRE- ARRIVAL TESTS BEFORE ENTERING PORT.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Lifesaving
Issued 11 November 1997
Resolved
CONDUCT FIRE AND ABANDON SHIP DRILLS TO THE SATISFACTION OF THE ATTENDING BOARDING OFFICER/MARINE INSPECTOR.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Construction/Loadline
Issued 11 November 1997
Resolved
REPAIR MISSING DOG ON #1 CARGO HATCH FORWARD OF #1 CARGO HOLD.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Fire Fighting
Issued 11 November 1997
Resolved
PROVIDE FLAG STATE APPROVAL FOR SELF SERVICING OF FIRE EXTINGUISHERS.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Fire Fighting
Issued 11 November 1997
Resolved
RELPACE ALL FIRE HOSES THROUGHOUT VESSEL.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Deck/Cargo
Issued 11 November 1997
Resolved
REMOVE ALL TRASH FROM OIL CONTAINMENTS THROUGHOUT VESSEL.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Fire Fighting
Issued 11 November 1997
Resolved
PROVIDE TWO ADDITIONAL BOLTS FOR INTERNATIONAL SHORE CONNECTION.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Deck/Cargo
Issued 11 November 1997
Resolved
REPLACE FLAME SCREENS ON FUEL OIL AND LUBE OIL VENTS.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Engineering
Issued 11 November 1997
Resolved
REMOVE EXCESSIVE OIL FROM DIESEL OIL PURIFIER ROOM.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Engineering
Issued 11 November 1997
Resolved
REPAIR RUNNING DIESEL OIL LEAK IN SUPPLY VALVE IN VISCINITY OF OIL PURIFIERROOM.
Condition: Unknown
Due 15 November 1997
Resolved 24 November 1997
Construction/Loadline
Issued 22 June 1996
Resolved
Make permanent repairs to the wasted framing on the underside of #3 cargo hatch prior to return to a U. S. port._x001C_ _x001C_ ICLL 66 II/16.1
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Construction/Loadline
Issued 22 June 1996
Resolved
Make permanent repairs to the wasted coaming plates on the port/stbd sides of #3 cargo hatch prior to return to a U. S. port. _x001C_ _x001C_ ICLL 66 II/16.1
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Accommodation/Occupational Safety
Issued 22 June 1996
Resolved
Make permanent repairs to the wasted reefer cooling pump strainer and manifold piping (up to overhead) prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Accommodation/Occupational Safety
Issued 22 June 1996
Resolved
Make permanent repairs to the wasted & patched F/W generator eductor pipingprior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Accommodation/Occupational Safety
Issued 22 June 1996
Resolved
Make permanent repairs to the wasted drain piping above the aft end of the MSD prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Accommodation/Occupational Safety
Issued 22 June 1996
Resolved
Make permanent repairs to the wasted cooling piping to the winch hydraulic system in the steering gear space prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Accommodation/Occupational Safety
Issued 22 June 1996
Resolved
Make permanent repairs to the engineroom lower level, port, fwd piping manifold prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Engineering
Issued 22 June 1996
Resolved
Provide mechanical plugs for the containment on the aft fuel vents and filllines prior to return to a U. S. port. _x001C_ _x001C_ 33 CFR 155.320
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Accommodation/Occupational Safety
Issued 22 June 1996
Resolved
Permanently repair the wasted & leaking MSD tank prior to return to a U. S.port. _x001C_ _x001C_ 33 CFR 159.7
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Engineering
Issued 22 June 1996
Resolved
Provide containment about the standard oil discharge connections prior to return to a U. S. port. _x001C_ _x001C_ 33 CFR 155.320
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Deck/Cargo
Issued 22 June 1996
Resolved
Make permanent repairs to the extensively leaking crane hydraulic systems prior to return to a U. S. port. Contain all oil leaks to prevent entry into the water. No cargo operations permitted in future U. S. ports until examined by Coast Guard Inspectors. 33 CFR 151.10(b)
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Engineering
Issued 22 June 1996
Resolved
Remove the overhead oil lines (rubber) to the stern tube system prior to departure. _x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Fire Fighting
Issued 22 June 1996
Resolved
Investigate the leaks on the strainer and repair the pulled electrical cable on the start box for the fwd fire pump. Remove the heat lamp and inappropriate wiring. Complete prior to departure. _x001C_ SOLAS 60 II/56.b.ii
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Electrical
Issued 22 June 1996
Resolved
Eliminate the ground in the 115 volt switchboard in the machinery space control room prior to departure. _x001C_ _x001C_ SOLAS 60 II/27
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Electrical
Issued 22 June 1996
Resolved
Prior to operation of the fwd generator, make permanent repairs to the fueloil leak on the high pressure line on the #1 piston. Provide a class report attesting to the satisfactory operation of the system. Complete prior to departure. SOLAS 60 II/26
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Electrical
Issued 22 June 1996
Resolved
Repair all oil leaks on fwd generator engine, repair all wasted cooling piping and leaking pumps. Complete prior to departure. _x001C_ _x001C_ SOLAS 60 II/26
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Electrical
Issued 22 June 1996
Resolved
Make permanent repairs to the wasted piping and clean the oil from the center generator engine prior to departure. _x001C_ _x001C_ SOLAS 60 II/26
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Fire Fighting
Issued 22 June 1996
Resolved
Prove proper operation of the fwd fire pump using the installed priming pump. Fwd pump would not operate until the aft pump was energized. Complete prior to departure. _x001C_ SOLAS 60 II/56.b.ii
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Engineering
Issued 22 June 1996
Resolved
Close the opened check valve that is aft of the M/E L/O filter prior to departure. _x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Engineering
Issued 22 June 1996
Resolved
Repair the loose wiring on the oily water separator solenoid valves and prove proper operation of the 15 ppm alarm. Complete prior to departure. _x001C_ MARPOL 73/78 I/16
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Electrical
Issued 22 June 1996
Resolved
Prove proper operation of the aft generator engine and generator. Repair all wasted piping on the engine. Complete prior to departure. _x001C_ _x001C_ SOLAS 60 II/26
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Fire Fighting
Issued 22 June 1996
Resolved
Provide evidence of a foam test date on the foam for the portable applicator in the upper, port, fwd section of the engineroom prior to departure. _x001C_ SOLAS 60 II/60
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Lifesaving
Issued 22 June 1996
Resolved
Provide a guard over the belt drives on the sludge pump (by incinerator) and the emergency fire pump priming pump prior to departure. _x001C_ _x001C_ SOLAS 60 II/65.b.ii
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Navigation
Issued 22 June 1996
Resolved
Repair the hydraulic leaks on the stbd steering gear motor prior to departure. _x001C_ _x001C_ SOLAS 60 II/29
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Fire Fighting
Issued 22 June 1996
Resolved
Remove the hold back hooks on the fire doors to the engineroom (fwd) and steering gear space. Repair the disabled closure device on the steering gear door. Complete prior to departure. _x001C_ SOLAS 60 II/36
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Fire Fighting
Issued 22 June 1996
Resolved
Remove the flammable products from the steering gear space to the approved paint locker prior to departure. _x001C_ _x001C_ SOLAS 74 amd II-2/18.7
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Documentation
Issued 22 June 1996
Resolved
Provide adequate fuel oil transfer procedures prior to any bunkering operations. _x001C_ _x001C_ 33 CFR 155.720
Condition: Unknown
Due 24 June 1996
Resolved 24 June 1996
Construction/Loadline
Issued 22 June 1996
Resolved
Replace the wooden plugs on the sounding tubes on the main deck with approved closures prior to return to a U. S. port. _x001C_ _x001C_ ICLL 66 II/20
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Fire Fighting
Issued 22 June 1996
Resolved
Remove the drums from about the emergency fire pump engine and secure the refrigerant cylinders properly in the same space prior to departure. _x001C_ _x001C_ SOLAS 60 II/65.b.ii
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Electrical
Issued 22 June 1996
Resolved
Remove the inappropriate wiring & lighting from (a) behind the reefer plant, (b) adjacent to the sludge pump controls, (c) from the port, aft lower level of the engineroom and (d) heat lamps from the steering gear motors prior to departure. SOLAS 60 II/27.a
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Engineering
Issued 22 June 1996
Resolved
Make an extensive cleaning of the oil in the engineroom, to include; bilges, generator engines, main engine, bilge pump area, purifier bulges and about emergency fire pump engine prior to departure. _x001C_ SOLAS 60 II/34
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Engineering
Issued 22 June 1996
Resolved
Identify and repair the leaks on the fuel tank on the weather deck aft of the masters cabin prior to departure. _x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Construction/Loadline
Issued 22 June 1996
Resolved
Remove the wooden plugs from the drain holes and replace with mechanical closures on #3 cargo hatch prior to departure. _x001C_ _x001C_ ICLL 66 II/16.1
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Engineering
Issued 22 June 1996
Resolved
Make permanent repairs to all wasted cooling piping on generator engines 1-3 prior to departure. _x001C_ _x001C_ SOLAS 60 II/26
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Engineering
Issued 22 June 1996
Resolved
Make permanent repairs to the wasted reduction gear cooling overboard line prior to departure. _x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Engineering
Issued 22 June 1996
Resolved
Make permanent repairs to the wasted & patched M/E J/W heat exchanger piping prior to departure. _x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Engineering
Issued 22 June 1996
Resolved
Make permanent repairs to the wasted & patched M/E L/O heat exchanger piping prior to departure. _x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Engineering
Issued 22 June 1996
Resolved
Make permanent repairs to the wasted stbd, fwd air compressor heat exchanger cooling piping prior to departure. _x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Engineering
Issued 22 June 1996
Resolved
Make permanent repairs to the wasted main generator J/W heat exchanger cooling piping prior to departure. _x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Engineering
Issued 22 June 1996
Resolved
Make permanent repairs to the wasted port / stbd M/E air box cooling pipingprior to departure. _x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Engineering
Issued 22 June 1996
Resolved
Make permanent repairs to the wasted piston cooling piping to the heat exchanger prior to departure. _x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Engineering
Issued 22 June 1996
Resolved
Remove the topping line leading into the piping to the generator engine J/Wheat exchanger prior to departure. _x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Engineering
Issued 22 June 1996
Resolved
Replace the broken gage on the M/E L/O filter prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 30 June 1996
Resolved 1 July 1996
Navigation
Issued 15 March 1989
Resolved
US COAST PILOT 7 NOT CORRECTED TO DATE. A REQUIREMENT OF 33CFR164.33(A)(3).
Condition: Unknown
Due 15 March 1989
Resolved 15 March 1989
Documentation
Issued 15 March 1989
Resolved
OIL TRANSFER PROCEDURES DID NOT CONTAIN ALL REQUIRED INFORMATION. A REQUIREMENT OF 33CFR155.750.
Condition: Unknown
Due 15 March 1989
Resolved 15 March 1989
Documentation
Issued 15 March 1989
Resolved
EACH OPERATION WAS NOT SIGNED IN THE OIL RECORD BOOK. A REQUIREMENT OF 33CFR151.25(H).
Condition: Unknown
Due 15 March 1989
Resolved 15 March 1989
Navigation
Issued 14 October 1987
Resolved
33CFR164.33(A)(1) THE VESSEL'S CHARTS 11324, 11327 AND 11329 WERE OUTDATED AND NOT CORRECTED, AND CHART 11328 WAS NOT CORRECTED.
Condition: Unknown
Due 14 October 1987
Resolved 14 October 1987
Documentation
Issued 14 October 1987
Resolved
33CFR155.750 THE VESSEL'S OIL TRANSFER PROCEDURES FOR BUNKER OPERATIONS WERE INCOMPLETE.
Condition: Unknown
Due 14 October 1987
Resolved 14 October 1987
Navigation
Issued 14 October 1987
Resolved
33CFR164.33(A)(2)(II) THE VESSEL DID NOT HAVE A U.S. COAST GUARD LIGHT LISTVOL. IV, GULF OF MEXICO OR ITS FOREIGN EQUIVALENT.
Condition: Unknown
Due 14 October 1987
Resolved 14 October 1987
Navigation
Issued 18 November 1985
Resolved
VSL BOARDED AT PORT OF TOLEDO 18 NOV 85 BY MSO TOLEDO BOARDING PARTY. VSL DID NOT HAVE ON BOARD THE FOLLOWING CHART: 14847.
Condition: Unknown
Due 20 November 1985
Resolved 18 November 1985