Records from 1985 to 2004. Most recent: inspection, 30 December 2004.
Inspection history · 19
30 December 2004
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2266162
14 March 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2024597
29 September 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1916216
6 June 2003
Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1811070
17 January 2003
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1731279
30 December 2002
MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1723250
31 October 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 283650
30 October 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 283549
7 August 2000
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 280651
6 August 2000
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 101709
14 September 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 432804
1 April 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 402062
16 August 1995
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 381694
9 December 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 347550
30 January 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 328329
11 May 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 316061
8 April 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 472794
14 November 1985
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 462103
23 September 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 304365
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 30 December 2004
No resolution recorded
During a CG inspection the Oily Water Separator three way valve was being serviced by a technician. The technician was unable to repair the three way valve. The vessel is prohibited from using the OWS until it proves proper operation of the OWS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 January 2005 — due date passed with no resolution recorded
Electrical › Mast
Issued 30 December 2002
Resolved
Repair/replace electrical junction box on mast below anchor light base.
Condition: Improper/Lack of Maintenance
Due 29 January 2003
Resolved 17 January 2003
Resolution: Junction box on mast repaired.
Accommodation/Occupational Safety › Occupational Safety
Issued 30 December 2002
Resolved
Install safety screen on evaporator fan in fish and lobby freezer. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 29 January 2003
Resolved 5 June 2003
Resolution: Received proper documentation satisfying requirement.
Lifesaving › Lifejacket/PFD (Type I)
Issued 30 December 2002
Resolved
Replace lifejacket for O/S Salvador due to its poor condition. LEGACY COMPONENT DESC: Condition
Due 30 December 2002
Resolved 30 December 2002
Resolution: Corrected on the spot.
Construction/Loadline › Structures
Issued 30 December 2002
Resolved
Replace/repair the door closing mechanism for the engine room door located on the main deck by crew quarters passageway. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Due 30 December 2002
Resolved 30 December 2002
Resolution: Corrected on the spot.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 30 December 2002
Resolved
Replace light fixture cover on light over cabin sink in Sewane and Apel accomodations. LEGACY COMPONENT DESC: Location
Due 29 January 2003
Resolved 5 June 2003
Resolution: Received proper documentation satisfying requirement.
Electrical
Issued 30 December 2002
Resolved
Remove electric fan wire connection from AB Cartel's state room which represent an electric hazard.
Condition: Improper Installation
Due 30 December 2002
Resolved 30 December 2002
Resolution: Corrected on the spot.
Engineering
Issued 30 October 2000
Resolved
Main engine has excessive oil leaks, contained in drip pans around every cylinder. Reference BALMS PS00068120 item BA03._x001C_ SOLAS 74/CHI/reg11
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Lifesaving
Issued 30 October 2000
Resolved
Port Lifeboat and lifeboat equip. not maintained. Water containers, deckingand fiberglass cracked and dryrotted._x001C_ SOLAS 74/CHIII/reg.19.2
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Navigation
Issued 7 August 2000
Resolved
Second Radar inoperative during Exam. Repair prior to departure from Port of Baltimore and supply Tech report to USCG.
Condition: Unknown
Due 7 August 2000
Resolved 9 August 2000
Deck/Cargo
Issued 7 August 2000
Resolved
Vessel had new cable installed on # 1 Cargo crane. PRIOR TO PLACING CRANE INTO OPERATION it must be load/weight tested to the satisfaction of Class IAW Vessels Cargo Gear Certificate._x001C_ SOLAS 74A I/II
Condition: Unknown
Due 8 August 2000
Resolved 9 August 2000
Lifesaving
Issued 7 August 2000
Resolved
Port Life Boat aft deck IWO Transmission and shaft wasted. Renew to satisfaction of Class._x001C_ _x001C_ SOLAS 74A III/19.2
Condition: Unknown
Due 31 October 2000
Resolved 30 October 2000
Lifesaving
Issued 7 August 2000
Resolved
VHF Chargers for 03 portable VHF radios (lifeboat) are connected to emergency lighting batteries w/clips. Hard wire correctly IAW Manufacturermanual for proper supply voltage/amps to chargers._x001C_ SOLAS
Condition: Unknown
Due 30 October 2000
Resolved 30 October 2000
Accommodation/Occupational Safety
Issued 7 August 2000
Resolved
Excess oil on deck plates between MDE and SSG._x001C_ _x001C_ SOLAS 74A III/19.2
Condition: Unknown
Due 31 October 2000
Resolved 30 October 2000
Lifesaving
Issued 14 September 1999
Resolved
Provide water borne test of starboard life boat and make appropriate log entry prior to next U.S. port.
Condition: Unknown
Due 9 August 2000
Resolved 9 August 2000
Engineering
Issued 14 September 1999
Resolved
Repair the fuel leak on the main engine's #7 cylinder low pressure fuel line prior to the next U.S. port.
Condition: Unknown
Due 9 August 2000
Resolved 9 August 2000