← All vessels
HELEN M
Freight Ship · General Dry Cargo Ship class · Built 1970s · USCG East District (CGD-E) · Other hulls named HELEN M
HELEN M is a 1977 freight ship. The Coast Guard has recorded 18 inspections since 1984, most recently in May 2000, along with 51 deficiencies and 1 operational control.
Records from 1984 to 2000. Most recent: inspection, 19 May 2000.
- Built
- 1977
- Last inspected
- 19 May 2000
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 51 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7706500 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HMI5
228332
Flag
GREECE
—
Maury page id
psix-228332
Inspections, by type
…with no type recorded18
Years with a record
10 calendar years (1984–2000)
The 18 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it17587 - Dead Weight, Ton
6226 - Regulatory (Subpart C or D), Net Ton
11070 - Regulatory (Subpart C or D), Gross Ton
6226 - Regulatory (Subpart C or D), Net Ton
11070 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 18
19 May 2000
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 276963
21 April 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 276998
24 October 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 434081
16 October 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 421473
17 August 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 419309
15 May 1998
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 415309
16 December 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 410289
15 September 1997
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 408041
6 June 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 404478
28 April 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 402870
11 May 1989
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 330227
1 October 1988
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 525455
28 March 1988
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 322570
10 April 1987
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 315312
2 April 1987
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 315217
2 September 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 311192
13 November 1985
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 503617
1 August 1984
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 297220
Deficiency record · 51
Deck/Cargo
Issued 21 April 2000
Resolved
Stbd Boom Support on main deck for #2 crane wasted. Make Proper Repairs.
Deck/Cargo
Issued 21 April 2000
Resolved
AIR LINE ON FORWARD MAST WASTED
Electrical
Issued 21 April 2000
Resolved
ELECTRICAL LIGHT INSIDE FORECASTLE HANGING FROM CONNECTING ELECTRICAL LIVE WIRE, NOT PROPERLY ATTACHED, TO OVERHEAD.
Engineering
Issued 21 April 2000
Resolved
EVAPORATOR DRAIN LINE HOLED 4 FOOT FROM OVERBOARD DISCHARGE. REPAIR WASTED SECTION OF PIPE.
Construction/Loadline
Issued 21 April 2000
Resolved
CEMENT PATCH ON FORWARD LINE LOCKER HATCH AT FLANG PIPE.
Construction/Loadline
Issued 21 April 2000
Resolved
HATCH DOGS ON FOREWARD LINE LOCKER HATCH WASTED.
Electrical
Issued 21 April 2000
Resolved
EMERGENCY BATTERY GROUND TERMINAL CONNECTIONS CRACKED.
Engineering
Issued 21 April 2000
Resolved
ELBOW FOR MAIN ENGINE LUBE OIL LINE CRACKED
Construction/Loadline
Issued 21 April 2000
Resolved
AFT BULKHEAD AT MAIN DECK OF FORECASTLE HOLED AND WASTED.
Accommodation/Occupational Safety
Issued 21 April 2000
Resolved
SEWAGE TANK HOLED AND WASTED REPAIRS MADE WITH PUTTY._x001C_ MAKE PERMANENT REPAIRS
Deck/Cargo
Issued 21 April 2000
Resolved
HYDRAULIC LINES TO DECK CRANES WASTED, FLANGE BOLTS WASTED.
Construction/Loadline
Issued 21 April 2000
Resolved
#2 STARBORD BALLAST TANK TAKING ON WATER (75 METRIC TONS IN 24 HOURS).OPEN BALLAST TANK AND INSPECT.
Engineering
Issued 21 April 2000
Resolved
PROPULSION ENGINE SURGING AND MAKING ABNORMAL NOISE FROM TURBOCHARGER_x001C_ REPAIR TO THE SATISFACTION OF CLASS
Electrical
Issued 24 October 1999
Resolved
Outboard limit switch on deck crane located on the stbd side aft of the deck house is not functional in non-adherence with SOLAS 1974 (amended) I/11. Switch arm was torn from its mount, and the mount was frozen as to prevent proper movement. Vsl required to correct NLT 09NOV99.
Navigation › Piloting/Steering › Magnetic Compass
Issued 24 October 1999
Resolved
Bridge magnetic compass illumination is not operable in non-adherence with 33 CFR 164.35. Vsl required to correct NLT 09NOV99.
Operations/Management › Drills/Instruction › Activating General Alarm
Issued 24 October 1999
Resolved
Public address system box in port cargo deck deckhouse passageway inoperable and has exposed electrical wiring in non-adherence with SOLAS 1974 (amended) I/11. Vsl required to correct NLT 09NOV99.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 24 October 1999
Resolved
Type III MSD not secured in a manner that prevents discharge of sewage intoprohibited areas described in 40 CFR 140.3 in non-adherence with 33 CFR 159.7. Vsl required to correct NLT 09NOV99.
Electrical
Issued 24 October 1999
Resolved
Throughout vsl, including paint locker, electrical light globes and guards missing/damaged in non-adherence with SOLAS 1960 II/27. Vsl must correct NLT 09NOV99. Until such time paint locker light is repaired, the paint locker electrical lighting circuit must remain de-energized.
Lifesaving
Issued 24 October 1999
Resolved
Port & Stbd lifeboat floating block side plates deteriorated thereby preventing lifeboats from being safely lowered in non-adherence with SOLAS 1974 (amended) III/19.2. Must be corrected prior to departure.
Construction/Loadline
Issued 24 October 1999
Resolved
Cargo deck immediately forward of the deck house in way of the port deck house access door holed in non-adherence with SOLAS 1974 (amended) I/11 andthe ICLL 1966. Hole observed when duct tape patch failed during filling of#4 ballast tank.
Lifesaving
Issued 24 October 1999
Resolved
Ring buoy waterlights not operational and/or unsatisfactorily repaired (e.g. use of aluminum foil in bulb socket to hold undersized bulb and maintain electrical continuity) in non-adherence with SOLAS 1974 (amended) III/19.2. Vsl must correct NLT 09NOV99.
Electrical
Issued 24 October 1999
Resolved
Lifeboat deck floodlight located stbd side aft of lifeboat electrical junction box fractured thereby creating risk of injury to crew & vsl in non-adherence with SOLAS 1960 II/27. Vessel must permanently repair or replace the junction box not later than 09NOV99.
Lifesaving
Issued 24 October 1999
Resolved
Flammable liquids improperly stowed throughout vsl; e.g. oil skin locker & aft stbd fire locker. Vsl must properly restow NLT 27OCT99. In lieu of restowing, vsl may elect to install appropriate fire extinguishing equipment pursuant to SOLAS 1974 (amended) II-2/18.7.
Lifesaving
Issued 24 October 1999
Resolved
Immersion suit air bladder inflation hoses not properly attached in non- adherence w/SOLAS 1974 (amended) III/19.2. Hoses when tugged (w/less force than what would occur in usage) disconnect from air bladder; hose/bladder interface exhibitting signs of deterioration. Vsl must correct NLT 09NOV99
Fire Fighting
Issued 24 October 1999
Resolved
Adjustable spray fire nozzle located at exterior deck fire station on stbd side lifeboat deck in way of lifeboat embarkation ladder frozen (corroded as to prevent use of adjustable spray feature) in non-adherence with SOLAS 1960 II/66. Vsl must correct NLT 09NOV99.
Lifesaving
Issued 24 October 1999
Resolved
Port lifeboat equipment not suitable for intented purpose; e.g. sail deteriorated, bilge pump strainer missing, two drain plugs missing in non- adherence with SOLAS 1974 (amended) III/19.2. Vsl must correct NLT 09NOV99.
Lifesaving
Issued 24 October 1999
Resolved
Stbd lifeboat equipment not suitable for intended purpose; e.g. food rations unsealed, firstaid kit not watertight, 2 drain plugs missing, in non-adherence with SOLAS 1974 (amended) III/19.2. Vsl must correct NLT 09NOV99.
Lifesaving
Issued 24 October 1999
Resolved
Stbd lifeboat appurtances missing and/or not suitable for intended purpose;e.g. exhaust pipe holed, battery missing, wood flooring suffering localizeddeterioration, & alternator electrical cover deteriorated in non-adherence with SOLAS 1974 (amended) III/19.2. Vsl must correct NLT 09NOV99.
Fire Fighting
Issued 24 October 1999
Resolved
Structural fire protection not maintained in way of engineroom bulkhead; e.g. bulkhead is holed in way of interior port cargo deck engineroom accessin non-adherence with SOLAS 1974 (amended) I/11. Vsl must correct NLT 09NOV99.
Lifesaving
Issued 24 October 1999
Resolved
Vessel practice is to stow large drums of combustible liquids used by the engineering dept in the cargo deck deckhouse passageway. Five observed during inspection. NLT 09NOV99 vsl is to provide satisfactory evidence that stowage is acceptable to the flag administration.
Fire Fighting
Issued 24 October 1999
Resolved
Potable fire extinguishers in galley and bridge not maintained in good condition; e.g. discharge hoses repaired with duct tape, in non-adherence with SOLAS 1960 II/66. Vsl must affect satisfactory repair or replace the portable extinguishers NLT 09NOV99.
Fire Fighting
Issued 24 October 1999
Resolved
Vessel's emergency fire pump is not operable in non-adherence with SOLAS 1960 II/65(b)(ii).
Fire Fighting
Issued 15 May 1998
Resolved
SOLAS 74 REG II/-2/21, FIREHOSES IN FIRESTATION BOX #2 AND #3 NEED REPLACEDDUE TO EROSION OF RUBBER LINING INSIDE HOSES.
Navigation
Issued 16 December 1997
Resolved
BACK UP RADAR INOP
Construction/Loadline
Issued 15 September 1997
Resolved
THE FORWARD COAMING ON HATCH NO. 3 HAS AN EXTENSIVE TRANSVERSE WELD FRACTURE CAUSED BY WELD EROSION.
Engineering
Issued 15 September 1997
Resolved
THE RAW WATER PIPE TO THE HEAT EXCHANGER FOR THE AUXILLIARY GENERATOR HAD ASOFT PATCH.
Lifesaving
Issued 15 September 1997
Resolved
THE BRIDGE WING QUICK RELEASE LIFE RINGS WERE NOT 4 KG. THE LIFE RING ON THE STARBOARD BRIDGE WING COULD NOT RELEASE FROM THE HOUSING IT WAS STOWED IN.
Construction/Loadline
Issued 15 September 1997
Resolved
THE HATCH COVER PONTOONS ALL SHOWED SIGNS OF EXTENSIVE WASTAGE AND/OR HAD NUMEROUS HOLES.
Deck/Cargo
Issued 15 September 1997
Resolved
THE CARGO GEAR HAD NUMEROUS DEFICIENCIES. UNTIL CLEARED BY CLASS, CARGO GEAR TO BE USED ONLY TO REMOVE PONTOONS FROM HATCHES. CARGO OPS SHALL NOT BE PERMITTED USING SHIP'S GEAR. SEE CLASS REPORT (97SFN036) ON BOARD VESSEL.
Navigation
Issued 15 September 1997
Resolved
SPEED LOG NOT OPERATIONAL.
Navigation
Issued 15 September 1997
Resolved
THE HELEN M TRANSITED U.S. WATERS WITHOUT THE ABILILITY TO OPERATE THEIR SECONDARY RADAR. EACH RADAR COULD BE OPERATED, BUT NOT TOGETHER.
Navigation
Issued 15 September 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Fire Fighting
Issued 28 April 1997
Resolved
REPAIR MINOR LEAK IN STBD ANCHOR WASH LINE. (SOLAS 74 CHAP 1 REG 11)
Fire Fighting
Issued 28 April 1997
Resolved
REPAIR MINOR LEAK IN SPRINKLER SYSTEM FOR PAINT LOCKER. (SOLAS 74 CH 1 REG 11)
Navigation
Issued 10 April 1987
Resolved
33 CFR 164.30 THE VESSEL DID NOT HAVE ON BOARD US COAST PIOLT (VOL.1),OR A FOREIGEN EQUIVALENTS,
Navigation
Issued 2 April 1987
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE VSL DID NOT HAVE O/B US COAST PILOT (VOL.3), OR A FOREIGN EQUIVALENT, WHICH WAS REQUIRED FOR THE VSL'S ROUTE FROM SMITH PT VA TO BALTIMORE HARBOR, AS REQUIRED BY 164.33(A)(2)(I)
Navigation
Issued 2 April 1987
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE VSL DID NOT HAVE O/B US CHARTS 12230, 12263,12278, AND 12281, OR THEIR FOREIGN EQUIVALENTS, WHICH WERE REQUIRED FOR THE VSL'S ROUTE FROM SMITH PT VA TO BALTIMORE HARBOR
Navigation
Issued 2 September 1986
Resolved
VESSEL WAS OPERATED WITHOUT THE CHARTS REQUIRED BY 33CFR164.30
Documentation
Issued 2 September 1986
Resolved
DATE AND RESULTS OF THE TESTS ON THE FUEL OIL PIPING SYSTEM AS REQUIRED BY 33CFR156.170 WERE NOT LOGGED
Navigation
Issued 2 September 1986
Resolved
THERE WAS NO CURRENLTY CORRECTED COPY OF THE U.S. COAST PILOT OR FOREIGN EQUIVALENT ON BOARD THE VESSEL
Navigation
Issued 2 September 1986
Resolved
VESSEL DID NOT HAVE CURRENTLY CORRECTED COPY OF U.S COAST GUARD LIGHT LIST OR FOREIGN EQUIVALENT ON BOARD
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.