MALAGA CARRIER

MALAGA CARRIER is a 1979 freight ship. The Coast Guard has recorded 64 inspections since 1986, most recently in April 2009, along with 33 deficiencies and 6 operational controls.

Records from 1986 to 2009. Most recent: inspection, 7 April 2009.

Built
1979
Last inspected
7 April 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7707920 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228351
Flag
SWEDEN
—
Maury page id
psix-228351

Inspections, by type

…with no type recorded33
Years with a record 18 calendar years (1986–2009)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it14173 - Dead Weight, Ton
5963 - Regulatory (Subpart C or D), Net Ton
15834 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 64

7 April 2009 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3443226
24 February 2009 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3423273
21 January 2009 Deficiency Check · Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3397975
3 November 2008 ISPS III Exam · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3356420
20 June 2008 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3242566
9 June 2008 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3231689
13 March 2008 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3164108
5 December 2007 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3109969
21 October 2007 Random ISPS/MTSA-No PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3083086
21 October 2007 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3085337
18 October 2007 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3086198
2 October 2007 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3071985
9 September 2007 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3053824
26 March 2007 Random ISPS/MTSA-No PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2895661
11 February 2007 Random ISPS/MTSA-No PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2871081
30 October 2006 ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2811092
9 October 2006 ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2796724
18 September 2006 Random ISPS/MTSA-No PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2781177
17 September 2006 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2782316
15 September 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2779531
28 August 2006 ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2762011
7 August 2006 ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2739436
7 August 2006 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2740578
26 July 2006 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2725635
17 July 2006 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2715572
16 July 2006 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2716354
21 February 2006 Random ISPS/MTSA/PSC · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2589522
2 February 2006 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2578969
15 August 2005 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2464280
27 July 2005 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2442288
27 July 2005 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2442289
26 July 2005 ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2440496
12 April 2005 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2332466
21 March 2005 Ballast Water Examination · NPV Safety Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2315372
12 July 2004 ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2130416
18 April 2004 Security Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2047016
9 March 2004 Annual Inspection · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2021563
22 September 2003 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2005529
25 February 2003 Ballast Water Examination · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1749513
24 July 2002 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1651147
5 June 2002 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1630338
11 February 2002 Annual Inspection · Security Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1485218
23 January 2002 Security Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1482041
12 December 2001 Security Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1483163
29 January 2001 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 286482
10 October 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 282685
21 March 2000 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 57799
9 February 2000 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 274150
18 January 2000 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 273449
12 March 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 413645
10 March 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 413594
25 November 1996 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 397777
27 July 1995 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 752427
26 July 1995 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 201983
29 June 1995 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 379822
5 June 1995 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 693632
30 May 1995 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 379059
14 November 1994 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 444072
10 March 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 365130
1 June 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 358647
28 March 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 342774
26 December 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 446904
17 November 1986 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 458903
3 March 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 307350

Deficiency record · 33

Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 24 February 2009 Resolved
9800- Visible exhaust leaks coming from both the #3 and #4 generator exhaust piping. Repair to the satisfaction of class prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 February 2009
Resolution: Observed all generators running with no leaks, crew made repairs on the 25th and a civilian company came out on the 27th and replaced exhaust gaskets and made permanent repairs to both #3 and #4 generators exhaust piping systems.
Fire Fighting › Fire Hoses › Condition
Issued 24 February 2009 Resolved
2555- Numerous hoses throughout the vessel were in questionable condition. Fire hose located on the lower level of the E/R in the SSDG space was so encrusted w/ salt that when it was faked out on deck it would not lay flat. All hoses onboard were pressurized with the fire pump and four (two from on deck and two from the E/R) were found with leaks/holes in them. Rectify to sat of USCG pr to dept.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 February 2009
Resolution: Chief Mate replaced and or repaired all four failed hoses. Hoses were then re-pressurized with the fire pump and tested sat.
Engineering › Freshwater System (cylinder head cooling) › Piping
Issued 24 February 2009 Resolved
1430- Observed a jacket water leak on the #4 generator. Approx 25 drips per minute. Repair to the satisfaction of class.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2009
Resolution: PSCO observed #4 generator running with no leakage. Class has attested to satisfactory rectification.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 24 February 2009 Resolved
0715 - Directly above the # 4 SSDG, smoke detector had been disassembled and the cover was hanging open exposing its wires. Class to attest to proper operation prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 March 2009
Resolved 3 March 2009
Resolution: Detector was tested in presence of PSCO with canned "smoke". Test sat.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 24 February 2009 Resolved
0715 - Directly above the # 3 SSDG, smoke detector was observed to be covered in black soot and was located in the direct path of the exhaust leak coming from the # 3 SSDG. Repair to the satisfaction of Class prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2009
Resolution: Detector was tested in presence of PSCO and class with canned "smoke". Test sat.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 24 February 2009 Resolved
0715 - Directly above the forward part of the main engine, the smoke detector was missing and directly above the aft part of the main engine the smoke detector was covered in soot. Class to attest to proper operation of smoke detector prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2009
Resolution: What were thought to be smoke detectors above the main engine are actually heat detectors. A heat gun was used to test both in the presence of the PSCO and Class satisfactorily.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 24 February 2009 Resolved
1499 - PSCO observed two large holes, approximately 1ft x 8 inches and 4 inches x 6 inches in diameter in the main engine exhaust piping located behind the turbo. The entire surrounding area of the exhaust piping and manifold is covered in black soot. Class to attest to integrity of M/E exhaust system prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2009
Resolution: Holes were repaired to satisfaction of class. PSCO witnessed the main engine running and did not note any exhaust leakage.
Fire Fighting › Combustible Materials › Primary Deck Coverings
Issued 24 February 2009 Resolved
1420 - Excessive oil (approximately 50 gallons) in the generator room bilges. Rectify to the satisfaction of class prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2009
Resolution: Bilges are satisfactory. PSCO Witnessed a contracted cleaning company onboard power washing all bilges. And also noted the vessel offloading oily waste on two separate occasions.
Fire Fighting › Combustible Materials › Primary Deck Coverings
Issued 24 February 2009 Resolved
1420 - Open buckets of oil were observed throughout the lower level of the main engine room, as well as oily rags left throughout all levels of the engine room. Rectify to the satisfaction of class prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2009
Resolution: All flammable materials have been removed to the satisfaction of class and PSCO.
Fire Fighting › Combustible Materials › Primary Deck Coverings
Issued 24 February 2009 Resolved
1420 - All decks and ladders throughout the engine room are slick with oil. Rectify to the satisfaction of class prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2009
Resolution: Vessel hired a civilian company to come in and pressure wash all decks ladders and bilges to class and PSCO''''''''s satisfaction.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 24 February 2009 Resolved
1420 - Portable electric fans throughout the engine room were covered in oil, chords were observed laying in deck level puddles of oil. Class to attest to removal of fans and cleanliness of E/R prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2009
Resolution: All portable fans were removed to satisfaction of class and USCG.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 February 2009 Resolved
1420 - Electrical cable run located in the overhead of the forward part of the lower level engine room are coated with oil. Clean to satisfaction of class prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 February 2009
Resolved 25 February 2009
Resolution: Cables and light were cleaned by ships force.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 24 February 2009 Resolved
9800 - PSCO observed raw sewage leaking from MSD inspection cover. Raw sewage had collected and pooled in the MSD containment area. Rectify to the satisfaction of class prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2009
Resolution: ships force pumped MSD system to the holding tank and resealed the inspection cover. Surrounding area was sanitized. Cause was a stuck float switch.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 24 February 2009 Resolved
2555 - Vessels SMS 4.15.4 states that the sewage plant shall be maintained, cleaned, and checked for correct operation. Rectify to the satisfaction of Flag prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2009
Resolution: Received Flag report which has been scanned into the document section of MISLE under-----FinalFlagRPT
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 24 February 2009 Resolved
2555 - Master and Chief Engineer are not carrying out weekly inspections of all spaces onboard, as required by the vessels SMS, and thereby are not reporting deficiencies, hazardous or unsanitary conditions as identified in deficiencies #'s 1, 2, 3, 4, 5, 7, 8, 9, 10, and 11 on the USCG Form B. Recommend external audit prior to dptr.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2009
Resolution: R/O conducted an external audit and has also scheduled another unscheduled ISM audit within 3 months. Received Flag and class reports which have been scanned into the document section of MISLE under-----FinalFlagRPT and DNV.
Electrical › Lighting (service) › Lighting Fixture
Issued 24 February 2009 Resolved
0950 - PSCO observed pin hole water leak from a potable water line spraying onto a lighting fixture leading into the steering room. Condition represents electrical/fire hazard. Repair to the satisfaction of class prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2009
Resolution: The section of piping that was leaking was cropped out and renewed to class and PSCO''''''''s satisfaction.
Electrical › Electric Generation Source (emergency) › Generator
Issued 24 February 2009 Resolved
1430 - When trying to start the emergency diesel generator, the secondary hydraulic starting mechanism failed to start the EDG. Rectify to satisfaction of USCG prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2009
Resolution: USCG visually watched the engineers use both means to start the EDG, all starts were satisfactory. Cause was low hydraulic fluid.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 24 February 2009 Resolved
0720 - PSCO observed a missing fire extinguisher that should have been on station on the mid level deck of the engine room. Rectify to satisfaction of USCG prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2009
Resolution: Extinguisher was replaced prior to USCG''s departure on the 23rd.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 24 February 2009 Resolved
0730 - All fire doors leading into and separating the two generator spaces would not close. The emergency escape trunk door on the lower level port side of the E/R would not close and latch on its own. Adjust/fix closure devices prior to departure to the satisfaction of CG/class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 February 2009
Resolved 25 February 2009
Resolution: Tested all self closing doors in the presence of class and flag representatives. Test sat.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 24 February 2009 Resolved
2555- As per vsls SMS, a non conformity (or defect rpt as stated in the SMS) is defined as a failure, non function, loss or damage of equipment & should be reported to the company. There is lack of evidence that the vsl prepared/submitted non conformity rpts addressing inop & clogged smoke alarms, exhaust leaks from #3&4 SSDG's, hole in the M/E exhaust ect. Recmd ext audit of ISM prior to dept.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 3 March 2009
Resolution: R/O conducted an external audit of the vsls ISM and has an unscheduled audit to be performed w/in 3 months. Flag and Class rpts are scanned into the documents tab of this activity.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 21 January 2009 Resolved
Bilges contain excessive amount of oil from SSDG. Oil soaked rags on SSDG's, presenting a fire hazard. SOLAS CH 1/ REG 11 Prior to departure to the satisfaction of the Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2009
Resolved 22 January 2009
Resolution: Form B was cleared to the satisfaction of CG.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 9 June 2008 Resolved
Vessel is required to have a Marine Sanitation Device (MSD) that is approved by the administration. MSD found to be inoperable and a temporary holding tank is being used as a substitute. The temporary holding tank must be approved by the classificaiton society.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 June 2008
Resolution: Received Classification Society Surveyor''s Report stating that the temporary holding tank being used as a sewage tank is approved as such.
Engineering › Diesel Engine (auxiliary) › Nozzle, Injection (fuel injection)
Issued 5 December 2007 Resolved
Make permanent repairs and prove proper operation of auxiliary generators #3 and #4 to the satisfaction of attending Class surveyor. SOLAS 74 II-1 Part D Reg 41.1.1 *************31 Jan 08 Received Classification Society Surveyor report with condition issued allowing vessel to sail through February in its current condition.***************
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 February 2008
Resolved 13 March 2008
Resolution: Received a report from the Classification [name withheld] attesting to the proper permanent repairs and operation of the #3 and #4 auxiliary generators.
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 21 February 2006 Resolved
Controllable pitch propeller ring seal was found to be worn and was allowing leakage.
Condition: Unknown
Due 22 February 2006
Resolved 22 February 2006
Resolution: Repairs were made in Port Hueneme and attested to by Class Society.
Navigation › Collision/Grounding Avoidance
Issued 11 February 2002 Resolved
Vessel's depth sounding device currently does not have a sufficient means to print and record information. LEGACY COMPONENT DESC: Echo-sounding Device Recorder
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 13 February 2002
Resolved 13 February 2002
Resolution: A printer was connected iaw manufacturers specs by contract electrician. System has been verified and approved by class (LRS) surveyor as stated within the class report provided to this office (MSD Santa Barbara). Vessel cleared for departure.
Navigation
Issued 10 October 2000 Resolved
Vessel's BA chart number 2604 was not currently corrected.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Construction/Loadline
Issued 18 January 2000 Resolved
The vessel's load line is not permanently marked on hull. ILLC 66, Annex I/Reg 8. Make all load line markings permanent and in black coloring priorto return to U.S. after sailing foreign.
Condition: Unknown
Due 14 February 2000
Resolved 14 February 2000
Lifesaving
Issued 18 January 2000 Resolved
Vessel's engine room contained excessive oil. ILO 147_x001C_ Remove excess oil prior to next U.S. port after sailing foreign.
Condition: Unknown
Due 14 February 2000
Resolved 14 February 2000
Construction/Loadline
Issued 10 March 1998 Resolved
VESSEL COULD NOT PROVIDE PAPER WORK PROVING CLASS REQUIRED REPAIRS WERE MADE TO CLASS SATISFACTION. VESSEL OR OPERATOR NEEDS TO PROVIDE THE PAPERWORK BY FAX OR AT THE NEXT US PORT.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Fire Fighting
Issued 10 March 1998 Resolved
PIPE FROM THE EMERGENCY FIRE PUMP HAS A WELDED PATCH OVER THE PIPE. THE VESSEL NEEDS TO REPLACE OR PERMANENTLY REPAIR THE PIPE BEFORE RETURN TO US WATERS.
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Engineering
Issued 10 March 1998 Resolved
GASKETS, VALVES, AND SOME MACHINERY IN THE ENGINE ROOM HAVE LEAKS THAT NEEDTO BE ADDRESSED BY THE NEXT REENTRY TO US WATERS.
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Documentation
Issued 30 May 1995 Resolved
THE OPERATORS OF THE VESSEL HAVE SUBMITTED THE VESSEL'S SOPEP FOR APPROVAL.THE AGENT LATER FAXED A COPY(DATED 04MAR95) OF A LETTER FROM THE FLAG STATEVERIFING THE PLAN WAS SUBMITTED TO THE NATL' MARITIME ADIMINSTRATION._x001C_
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Navigation
Issued 3 March 1986 Resolved
33CFR164.33(A)(1) NOS CHART 18751 OR EQUIVALANT NOT ON BOARD 33CFR164.33(A)(2) LIGHT LIST ADM VOL G (1985) NOT CORRECTED UP TO DATE
Condition: Unknown
Due 3 March 1986
Resolved 3 March 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.