Records from 1986 to 1997. Most recent: operational control imposed, 23 July 1997.
Documentation
Issued 23 July 1997
No resolution recorded
Officers and crew on board have licenses and certificates from flag states other than the flag of the vsl (Singapore) without documentation that the flag state accepts these. Vsl must provide proof of flag state acceptance of current certifications prior to return to U.S. from overseas.
Condition: Unknown
Due 26 July 1997 — due date passed with no resolution recorded
Navigation
Issued 23 July 1997
No resolution recorded
Vessels rudder has excessive play. Vsl must have class inspect and make recomendations prior to departure.
Condition: Unknown
Due 30 April 1998 — due date passed with no resolution recorded
Documentation
Issued 23 July 1997
Resolved
Errors found on vsls Safety Construction cert and IOPP. The build date on the Safety Construction cert is 1997, the actual build date is 1977. The vsls IOPP states that the vsl has a 15 ppm alarm and oil content meter for OWS equipment, which it does not have. Class must address/correct.
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Fire Fighting
Issued 23 July 1997
Resolved
Vessel entered port with an inoperable emergency fire pump and the main genserv/fire pump leaking excessivley. A SOLAS intervention was conducted._x001C_ The vsl is required to repair both pumps to the satisfaction of their classsociety prior to departure.
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Fire Fighting
Issued 23 July 1997
No resolution recorded
Bridge firefighting outfit interior of suit was dry rotted and closures were torn off. Outfit must be replaced prior to return to U.S. from an overseas port.
Condition: Unknown
Due 26 July 1997 — due date passed with no resolution recorded
Fire Fighting
Issued 7 November 1996
Resolved
Crew is experiencing intermittent success with the emergency fire pump. Problems have arisen with the priming pump and the system was altered. Repair system as needed to provide for reliable operation prior to return to a U. S. port. SOLAS 60 II/65.b
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Electrical
Issued 7 November 1996
Resolved
Renew the makeshift light fwd, stbd of the generators between bulkhead & service tank prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/23
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Construction/Loadline
Issued 7 November 1996
Resolved
Repair hole in the deck inboard of the forecastle stbd vent prior to departure. _x001C_ _x001C_ ICLL 66 I/1
Condition: Unknown
Due 30 November 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 7 November 1996
Resolved
Repair the loose oil pressure sensor line / box for the main engine (port, fwd, mid level by the HP fuel pumps). Complete prior to departure. _x001C_ _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Electrical
Issued 7 November 1996
Resolved
Identify the location of the full ground in the 110 volt circuit and repairprior to departure. _x001C_ _x001C_ SOLAS 60 II/23
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Fire Fighting
Issued 7 November 1996
Resolved
Remove the hold back hooks on both E/R fire doors and replace the missing handle on the stbd door. Assure doors will effectively close. Also assuredoor to steering gear space remains closed. Complete prior to departure. SOLAS 60 II/54
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Engineering
Issued 7 November 1996
Resolved
Make permanent repairs to the piping on the M/E air boxes (4). The branch lines and manifold line have numerous locations of wastage and patching. Complete prior to departure. _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Accommodation/Occupational Safety
Issued 7 November 1996
Resolved
Make permanent repairs to the extensively wasted sewage & drainage lines inthe E/R overhead. Complete prior to return of a U. S. port. _x001C_ _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Construction/Loadline
Issued 7 November 1996
Resolved
Repair the holed stbd vent to the forecastle space. Examine port side for possibility of similar problems. Complete prior to departure. _x001C_ _x001C_ ICLL 66 II/19.1
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Construction/Loadline
Issued 7 November 1996
Resolved
Repair the forward access trunk to number 2 cargo hold where holed (2 locations) prior to departure. _x001C_ _x001C_ ICLL 66 II/18.1
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Fire Fighting
Issued 7 November 1996
Resolved
Close the opening about the new pipe penetration through the bulkhead over the door to the steering gear space. Complete prior to return to a U. S. port._x001C_ SOLAS 60 II/54
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Fire Fighting
Issued 7 November 1996
Resolved
Clean the excessive oil from about the M/E L/O pumps, all purifiers and about the stbd upper service tank. Complete prior to return to a U. S. port. _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Engineering
Issued 7 November 1996
Resolved
Make permanent repairs to the M/E cooling line outboard of the lower level,stbd purifier, where it is wasted & leaking. Complete prior to departure. _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Engineering
Issued 7 November 1996
Resolved
Make permanent repairs to the M/E auxiliary cooling line above the manifold(port, LL), where it is wasted & leaking. Complete prior to departure. _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Engineering
Issued 7 November 1996
Resolved
Make permanent repairs to the generator cooling line above the manifold (port, LL), where it is wasted & leaking. Complete prior to departure. _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Engineering
Issued 7 November 1996
Resolved
Make permanent repairs to the port M/E cooling pump discharge line, where it is band patched & patched with liquid metal. Complete prior to departure. _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Construction/Loadline
Issued 7 November 1996
Resolved
Make permanent repairs to the firemain / chain wash line (stbd, forecastle,overhead), where it is patched. Complete prior to return of a U. S. port. _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Engineering
Issued 7 November 1996
Resolved
Make permanent repairs to the Reefer & AC cooling lines above the manifold where wasted & leaking. Also repair the manifold and aft supply line whereit extends under the reefer pump. Complete prior to return of a U. S. port. SOLAS 60 II/28
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Engineering
Issued 7 November 1996
Resolved
Make permanent repairs to the unidentified line (1 inch) under the reefer /AC pump, where it is wasted, patched & leaking. Complete prior to return of a U. S. port. _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Construction/Loadline
Issued 7 November 1996
Resolved
Make permanent repairs to the aft peak fill line (above tail shaft in E/R),where it is patched. Complete prior to return of a U. S. port. _x001C_ _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Engineering
Issued 7 November 1996
Resolved
Make permanent repairs to the M/E cooling line over the stbd general service pump, where it is wasted & leaking. Complete prior to departure. _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Construction/Loadline
Issued 7 November 1996
Resolved
Make permanent repairs to the main ballast line (fwd, LL, just stbd of center line), where it is wasted & leaking. Complete prior to departure. _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Construction/Loadline
Issued 7 November 1996
Resolved
Make permanent repairs to the main ballast line (overhead near the port, fwd sea chest), where it is wasted & leaking. Complete prior to departure._x001C_ SOLAS 60 II/28
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Electrical
Issued 7 November 1996
Resolved
Replace / repair the guard on the paint locker explosion proof light prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 I/23
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Electrical
Issued 7 November 1996
Resolved
Renew the wood mounted circuit breaker in the center deck house pump room with an approved system prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/23
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Fire Fighting
Issued 7 November 1996
Resolved
Remove the oil drums in the stbd main deck passage prior to return to a U. S. port. _x001C_ _x001C_ ILO 147
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Engineering
Issued 7 November 1996
Resolved
Replace all missing valve handles throughout the machinery space prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 I/28
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Navigation
Issued 7 November 1996
Resolved
Provide double nut or cotter pin connections on all steering gear control &RAI linkages prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/29
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Engineering
Issued 7 November 1996
Resolved
Provide containment boxes for all fuel & L/O vents & fill lines on the upper deck (that are missing). Provide mechanical plugs for all existing containment boxes. Complete prior to return to a U. S. port. _x001C_ 33 CFR 155.320(a)
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Deck/Cargo
Issued 7 November 1996
Resolved
Repair all leaking hydraulic systems on the center deck house and #1 cargo hatch. Clean all oil to prevent its entry into the water. Complete prior to return to a U. S. port. _x001C_ 33 CFR 151.10(b)
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Electrical
Issued 7 November 1996
Resolved
Remove the electrical splices on the incinerator wiring prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Construction/Loadline
Issued 7 November 1996
Resolved
Provide wing nuts for windows on the stern & replace glass where holed prior to departure. _x001C_ _x001C_ ICLL 66 II/18.1
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Engineering
Issued 7 November 1996
Resolved
Make repairs to or remove the mess of wiring about the top of the auxiliaryboiler prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Fire Fighting
Issued 7 November 1996
Resolved
Remove paint from E/R & forecastle space and move to approved paint locker prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 amd II-2/18.7
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Engineering
Issued 7 November 1996
Resolved
Assure all double bottom sounding tubes are closed (when not in use), have caps and spring actuators that are operational. Complete prior to return to a U. S. port. _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Construction/Loadline
Issued 7 November 1996
Resolved
Repair the forecastle booby hatch where wasted & patched with duct tape (3 locations). Also renew the independent man hole cover as it is badly wasted about the gasket retainer. Complete prior to departure. _x001C_ ICLL 66 II/18.1
Condition: Unknown
Due 30 November 1996
Resolved 3 January 1997
Engineering
Issued 7 February 1995
Resolved
VESSELS' SMALL DISCHARGE CONTAINMENT WAS NOT CLOSED BY MECHANICAL MEANS.
Condition: Unknown
Due 7 February 1995
Resolved 15 February 1995
Engineering
Issued 7 February 1995
Resolved
VESSEL OIL TRANSFER PROCEDURES WERE INCOMPLETE AS PER 33 C.F.R. 155.750(a)(1-5)(9)._x001C_
Condition: Unknown
Due 15 December 1995
Resolved 15 December 1995
Navigation
Issued 19 June 1989
Resolved
B.A.COAST PILOT VOL.8 MISSING SUPPLEMENT 8. CORRECTED PUBLICATIONS ARE A REQUIREMENT OF 33CFR164.33(A)(2)(I).
Condition: Unknown
Due 15 December 1995
Resolved 15 December 1995
Navigation
Issued 22 March 1986
Resolved
OPERATING A VESSEL WITH A OUTDATED U.S. COAST PILOT (1982), A VIOLATION OF 33 CFR 164.33 (A)(2)(I).
Condition: Unknown
Due 22 March 1986
Resolved 22 March 1986
Navigation
Issued 22 March 1986
Resolved
OPERATING A VESSEL WITH AN OUTDATED C.G. LIGHT LIST (1979), A VIOLATION OF 33 CFR 164.33 (A)(2)(II).
Condition: Unknown
Due 22 March 1986
Resolved 22 March 1986