MAURY USCG vessel records Sign in
← All vessels

VIRANA

VIRANA is a freight ship. The Coast Guard has recorded 39 inspections since 1985, most recently in June 2007, along with 22 deficiencies.

Records from 1985 to 2007. Most recent: inspection, 14 June 2007.

Built
Not recorded
Last inspected
14 June 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7710408 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228387
Flag
LIBERIA
—
Maury page id
psix-228387

Inspections, by type

…with no type recorded27
Years with a record 17 calendar years (1985–2007)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it42424 - Dead Weight, Ton
12572 - Convention (Subpart B), Net Ton
19997 - Simplified, Net Ton
41905 - Convention (Subpart B), Gross Ton
41905 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 39

14 June 2007 ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2961375
15 April 2007 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2908217
20 October 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2804708
17 August 2006 PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2750803
18 June 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2683474
17 April 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2626723
1 May 2005 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2346745
4 March 2005 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2301413
13 January 2005 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2275211
11 January 2005 MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2271174
1 February 2003 Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1738295
30 November 1999 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 435193
1 February 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 425123
14 December 1998 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 423502
25 January 1998 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 412210
29 August 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 407283
24 August 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 407036
14 January 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 363777
8 July 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 438226
26 April 1993 Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1366825
22 April 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 667437
21 April 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 43672
21 April 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 123654
14 January 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 513311
7 October 1992 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 486314
20 June 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 344489
14 December 1990 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 482239
22 March 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 335991
3 May 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 440215
20 November 1988 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 326954
17 November 1988 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 326872
12 March 1988 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 520124
25 August 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 318087
15 December 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 476947
7 July 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 309959
21 May 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 449504
25 March 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 307734
6 February 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 491842
13 July 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 303115

Deficiency record · 22

Engineering › Lubricating Oil Service System › Tank
Issued 13 January 2005 Resolved
1799 - Make Permanent Arrangement for sludge tank overflow system (to incinerator) which is currently fabricated from used oil drum at lower and middle engineroom, port side of main engine, per DNV Condition of Class dated 13JAN05: Due date by Class of 12APR05.
Action required: 705 - Other - as specified
Due 12 April 2005
Resolved 4 March 2005
Resolution: System repaired to the satisfaction of class.
Fire Fighting › Fire Main › Condition
Issued 13 January 2005 Resolved
0700 - Permanently repair leaky fire main on bilge eductor near oily water separator per Condition of Class date 13JAN05.
Action required: 705 - Other - as specified
Due 13 February 2005
Resolved 4 March 2005
Resolution: System repaired to the satisfaction of class.
Documentation › Certificates/Documents › IOPP Certificate
Issued 11 January 2005 Resolved
Include all waste oil tanks (sludge) in block 3 of IOPP. MARPOL 73/78 I. 15a
Action required: 705 - Other - as specified
Resolved 13 January 2005
Resolution: Class DNV - The Incinerator Settl. Tank (0.4 cu. mtr.) and LO Purifier Sludge Tank (0.4 cu. mtr.) have been added in Item 3.1 of the IOPP Supplement. Other tanks recirculated back into the system and therefore are not required to be added.
Documentation › Logs/Records › Oil Record Book
Issued 11 January 2005 Resolved
Commence making entries into the oil record book as per the instructions found in appendix III of annex I of MARPOL 73/78 where the C-II-I & 2 entries have been mixed with the C-12-2 & 3 entries and the quantity of contents retained is missing. 60 b.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2005
Resolution: Per Class DNV Survey Report dated 13JAN05 - The Chief Engineer has been instructed of how to make proper entries. Also verified by USCG Inspectors.
Fire Fighting › Fire Pumps › Pressure
Issued 11 January 2005 Resolved
Repair as original the pressure gauge to the port fire pump. SOLAS 60/I-II. 70a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 January 2005
Resolution: Per Class DNV Survey Report dated 13JAN05 - The pressure gauge for the Port Fire Pump has been renewed. Tested the fire pump and found the pressure gauge functioning satisfactorily.
Engineering › Generator (propulsion-electric) › Equipment Grounding Circuitry
Issued 11 January 2005 Resolved
Repair fuel leak on all generator port aft corners of prime movers, remove wetted insulation and provide protection of oil system in required locations. SOLAS 74amd II-2 15.9-II. 15a
Action required: 15 - Rectify deficiencies by next port
Resolved 13 January 2005
Resolution: Per Class DNV Survey Report dated 13JAN05 - The wetted insulation on the fuel oil line has been removed and fitted with new insulation.
Deck/Cargo › Cargo Stowage › General
Issued 11 January 2005 Resolved
Remove pipes, plates, and extra gear from the low pressure CO2 room. SOLAS 60 I/II. 15a
Action required: 15 - Rectify deficiencies by next port
Resolved 13 January 2005
Resolution: Per Class DNV Survey Report dated 13JAN05 - All the pipes and plates have now been removed from the CO2 room.
Engineering › Lubricating Oil Service System › Tank
Issued 11 January 2005 Resolved
Provide class approval of the sludge tank overflow system that is fabricated from used oil drum at lower and middle engine room port side of main engine where tank is now filled with diesel type fuel vice sludge. MARPOL 73/78 I. 15a
Action required: 705 - Other - as specified
Due 12 April 2005
Resolved 13 January 2005
Resolution: DNV Condition of Class issued to make a permanent arrangement and remove the oil drum by 12APR05.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 January 2005 Resolved
Prove proper operation of oily water separating equipment where bypass pipe appears to be fitted. SOLAS 60 I/II and MARPOL 73/78 I. 15a
Action required: 15 - Rectify deficiencies by next port
Resolved 13 April 2005
Resolution: The Oily bilge water separator was tested and found functioning satisfactorily including the 15 ppm bilge alarm by DNV Surveyor. Improper bypass not in place (addressed in Special Note).
Navigation › Piloting/Steering
Issued 1 February 2003 Resolved
MAKE PERMANENT REPAIRS TO PORT BRIDGE WING RUDDER ANGLE INDICATOR. (OFF APPROX. 4 DEGREES). SOLAS 74(A)II-1/29.11 LEGACY COMPONENT DESC: Rudder Angle Indicator- Port Brigde Wing
Condition: Unknown
Due 1 March 2003
Resolved 19 February 2003
Resolution: RECEIVED FAX FROM MASTER, ITEM CORRECTED
Communications › Alarms/Indicators
Issued 1 February 2003 Resolved
MAKE PERMANENT REPAIRS TO INOPERATIVE GENERAL ALARM BELL ON AFT POOP DECK ABOVE WORKSHOP STORES. MASTER TO MODIFY FIRE PARTY PROCEDURES TO HAVE AN INVESTIGATOR NOTIFY PERSONNEL IN AFFECTED AREA UNTIL ALARM IS FIXED. SOLAS 74(A)II-2/13 LEGACY COMPONENT DESC: General Alarm
Condition: Unknown
Due 1 March 2003
Resolved 19 February 2003
Resolution: RECEIVED FAX FROM MASTER, ITEM ABOVE WAS NOT PART OF THE G/Q ALARM SYSTEM BUT PART OF THE TELEPHONE SYSTEM. TO IMPROVE THE SAFETY OF THE VESSEL AND CREW, MASTER WILL INSTALL AN EXTRA ALARM BELL AND INCOOPERATE IT INTO THE G/Q SYSTEM
Navigation
Issued 30 November 1999 Resolved
Make permanent repairs to rudder angle indicator on bridge. Unit now showserratic movement when wheel is hard to port. Rudder angle indicators on bridge and wings also inaccurate. Bridge indicators show 28.5 at 25 deg, and 34.5 at 30 deg actual. Provide class report of proper operation.
Condition: Unknown
Due 7 December 1999
Resolved 1 February 2003
Resolution: All rudder angle indicators working except port bridge wing. Cleared this def. Reissued new def. for port wing rudder angle indicator.
Accommodation/Occupational Safety
Issued 30 November 1999 Resolved
Make repairs to inoperative general alarm bell on aft poop deck above workshop stores.
Condition: Unknown
Due 7 December 1999
Resolved 1 February 2003
Resolution: Per crew, alarm was fixed post issue date. Def. cleared . Alarm found to be non-operational. Prior def. cleared due to age, reissued new def. to be corrected 01Mar03 (30 days).
Accommodation/Occupational Safety
Issued 14 December 1998 Resolved
Replace spool piece at inlet side of strainer for injector pump supply to evaparator._x001C_ Solas 74 (a) II-1/26.1
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Fire Fighting
Issued 14 December 1998 Resolved
Correct hydraulic leaks on emergency fire pump engine._x001C_ _x001C_ Solas 74(A) II-1/26.1
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Fire Fighting
Issued 14 December 1998 Resolved
Correct exaust leaks for emergency fire pump engine._x001C_ _x001C_ Solas 74(a) II-1/26.1
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Fire Fighting
Issued 14 December 1998 Resolved
Provide nonslip surface around emergency fire pump engine._x001C_ _x001C_ ILO 66
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Fire Fighting
Issued 14 December 1998 Resolved
Prove proper operation of emergency fire pump._x001C_ _x001C_ Solas 74(a) II-2/21
Condition: Unknown
Due 3 February 1999
Resolved 3 February 1999
Engineering
Issued 24 August 1997 Resolved
EXHAUST DUCT AND CONNECTING FLANGES LOCATED ON THE FIRST PLATFORM OF THE ENGINE ROOM, AFT OF THE SEWAGE TANK, HOLED AND DETERIORATING.
Condition: Unknown
Due 9 September 1997
Resolved 9 September 1997
Documentation
Issued 17 November 1988 Resolved
DANGEROUS CARGO MANIFEST NOT SIGNED BY PREPARER.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Navigation
Issued 25 August 1987 Resolved
VESSEL TRNASITED PUGET SOUND WITH ONE RADAR INOPERATING NORMALLY AS RE- QUIRED BY 33 CFR 164.37(A).
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Navigation
Issued 25 March 1986 Resolved
VESSELS'S 1985 U.S. COAST PILOT, VOL. 7, WAS NOT CURRENTLY CORRECTED. (CONTAINED ZERO CORRECTIONS)
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.