Records from 1985 to 2004. Most recent: inspection, 2 March 2004.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 32
2 March 2004
Ballast Water Examination · Certificate of Compliance
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2016805
9 December 2002
Special Interest Vessel
Type not classified · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1718445
2 December 2002
Ballast Water Examination · Periodic Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1712479
18 March 2002
Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1494303
9 March 2002
Tank Vessel Examination · Certificate of Compliance
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1492643
21 November 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 295710
23 June 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 291313
19 January 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 286187
19 January 2001
Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1061162
8 January 2000
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 273483
24 June 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 430056
8 April 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 427364
15 December 1998
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 423530
7 November 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 422412
12 October 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 6463
10 August 1998
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 69926
10 July 1998
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 418072
24 October 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 409429
26 April 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 402931
24 September 1996
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 455961
9 June 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 392138
6 June 1996
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1186660
5 April 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 699357
24 March 1994
Tank Vessel Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1459085
17 March 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 699351
10 December 1991
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 347666
10 December 1991
Deficiency Check · MARPOL Annex II Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1256018
24 October 1991
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 937110
12 December 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 528043
31 May 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 303091
26 May 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 302283
26 May 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 982323
Electrical › Electrical Distribution System (service)
Issued 2 March 2004
Resolved
The vessel's 440V A/C electrical distribution system has a dead ground. LEGACY COMPONENT DESC: Ground Detection
Action required: 705 - Other - as specified
Due 9 March 2004
Resolved 9 March 2004
Resolution: Received report stating that the ground had been isolated, repaired and tested to the satisfaction of class.
Lifesaving
Issued 7 November 1998
Resolved
EMERGENCY LIGHTERING EQUIPMENT NOT ON BOARD AS PER 33 CFR 157.410. PROVIDEON BOARD PRIOR TO 1 DEC 98.
Condition: Unknown
Due 8 November 1998
Resolved 8 November 1998
Documentation
Issued 7 November 1998
Resolved
THIRD OFFICER'S LICENSE ENDORSED FOR "SHORT VOYAGE NAVIGATION". PROVIDE LETTER OF ACCEPTANCE FROM THE FLAG STATE TO SHOW SUITABILITY OF SERVICE FORINTERNATIONAL VOYAGES. SOLAS 74 REG V/13A
Condition: Unknown
Due 8 November 1998
Resolved 8 November 1998
Construction/Loadline
Issued 6 June 1996
Resolved
DEFICIENCY BRO2 (CASE# MI91042821) DATED 10DEC91 CONCERNING INSTALLATION OF15PPM ALARM AS PER INTERIM IOPP CERTIFICATE WAS OPERATIONALLY TESTED AND FOUND SATISFACTORY DURING THE TANK VESSEL EXAMINATION.
Condition: Unknown
Due 9 June 1996
Resolved 12 June 1996
Construction/Loadline
Issued 6 June 1996
Resolved
DEFICIENCY 1 DATED 24OCT91 (CASE# MI91036639) CONCERNING VESSEL'S OILY WATER SEPARATOR 15 PPM ALARM WAS OPERATIONALLY TESTED AND FOUND SATISFACTORY DURING TANK VESSEL EXAMINATION.
Condition: Unknown
Due 9 June 1996
Resolved 12 June 1996
Construction/Loadline
Issued 6 June 1996
Resolved
DEFICIENCY HR01 (CASE# PS94028228) DATED 24MAR94 CONCERNING OWS DID NOT HAVE 15PPM ALARM AS REQUIRED BY VESSEL'S IOPP CERTIFICATE WAS OPERATIONALLYTESTED AND FOUND SATISFACTORY DURING TANK VESSEL EXAMINATION.
Condition: Unknown
Due 9 June 1996
Resolved 12 June 1996
Construction/Loadline
Issued 10 December 1991
Resolved
INSTALL A 15PPM OILY WATER SEPARATOR ALARM AS PER INTERIM IOPP CERTIFICATE.
Condition: Unknown
Due 10 December 1991
Resolved 10 December 1991
Documentation
Issued 10 December 1991
Resolved
HAVE ANNUAL SURVEYS CONDUCTED FOR LOADLINE AND MARPOL (IOPP) CERTIFICATES PRIOR TO DEPARTING PORT.
Condition: Unknown
Due 20 December 1991
Resolved 16 December 1991
Engineering
Issued 24 October 1991
Resolved
DEMONSTRATE OPERATION OF OILY WATER SEPARATOR 15 PPM ALARM TO PRIOR TO RETURNING TO U.S.
Condition: Unknown
Due 24 October 1991
Resolved 24 October 1991
Engineering
Issued 24 October 1991
Resolved
RENEW FLAME SCREEN FOR FUEL MIXTURE TANK VENT (HEAVY AND LIGHT FUEL) LOCATED PORTSIDE FRONT OF ACCOMMODATION HOUSE ON 01 DECK PRIOR TO RETURNINGTO U.S.
Condition: Unknown
Due 24 October 1991
Resolved 24 October 1991
Fire Fighting
Issued 24 October 1991
Resolved
PROVIDE FOUR PROPER LIFELINES FOR FIREMAN OUTFITS AS PER SOLAS REGS PRIOR TO RETURNING TO U.S.
Condition: Unknown
Due 24 October 1991
Resolved 24 October 1991
Navigation
Issued 26 May 1985
Resolved
33 CFR 164.33 VESSEL DID NOT HAVE A RECENT EDITION OF THE TIDAL CURRENT TABLES ON BOARD.THE AGENT ORDERED THE PUBLICATION FROM HOUSTON AT 1430 BUT THE SHIPPING COMPANY FAILED TO DELIVER IT BEFORE THE VESSEL SAILED AT 2300.
Condition: Unknown
Due 26 May 1985
Resolved 26 May 1985