Records from 1985 to 1999. Most recent: inspection, 6 November 1999.
Inspection history · 27
6 November 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 112320
22 October 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 434623
2 June 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 429225
26 March 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 203046
26 March 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 757643
17 June 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 147431
11 June 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 416886
24 April 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 414588
22 April 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 29759
1 August 1996
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 393804
3 April 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 695013
26 March 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 389320
15 February 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 695014
14 February 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 387942
14 February 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 695015
24 August 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 382074
11 June 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 379301
7 June 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 379067
7 May 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 377807
31 December 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 931987
30 December 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 341076
9 December 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 537697
21 November 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 326958
8 March 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 436833
26 February 1986
Type not recorded
No type recorded · COTP NEW LONDON · USCG Northeast District (CGD-NE) · Activity 530300
3 December 1985
Type not recorded
No type recorded · COTP NEW HAVEN · USCG Northeast District (CGD-NE) · Activity 523033
1 July 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 302921
Fire Fighting › Combustible Materials › Ceilings
Issued 2 June 1999
Resolved
Repair holed firemain stbd side in way of #3 & #4 holds; stbd side in way of #1 hold and port & stbd aft deck house in way of lifeboats
Condition: Unknown
Due 1 July 1999
Resolved 13 November 2006
Documentation › Certificates/Documents › Annex VI Statement of Voluntary Compliance
Issued 2 June 1999
Resolved
Provide approved cargo securing manual. SOLAS 74/VI/5.6
Condition: Unknown
Due 1 July 1999
Resolved 13 November 2006
Lifesaving › Buoyant Apparatus › Approval
Issued 2 June 1999
Resolved
Replace unserviceable life boat food. (47 packs) SOLAS 60/III/11.a.xii
Condition: Unknown
Due 1 July 1999
Resolved 13 November 2006
Unknown
Issued 2 June 1999
Resolved
.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Lifesaving
Issued 24 April 1998
Resolved
PORT LIFEBOAT DAVIT LIMIT SWITCH INOPERABLE/INEFFECTIVE._x001C_ SOLAS 60 REG III/36K
Condition: Unknown
Due 23 June 1998
Resolved 23 June 1998
Construction/Loadline
Issued 24 April 1998
Resolved
PROVIDE CONTAINMENT FOR WASTE OIL TANK VENTS PRIOR TO CONDUCTING ANY TRANSFERS UTILIZING WASTE OIL TANKS._x001C_ MARPOL 73/78 ANNEX II
Condition: Unknown
Due 23 June 1998
Resolved 23 June 1998
Electrical
Issued 24 April 1998
Resolved
EXPLOSION PROOF LIGHTING FIXTURE IN PAINT ROOM MISSING COVER.
Condition: Unknown
Due 24 April 1998
Resolved 26 May 1998
Fire Fighting
Issued 24 April 1998
Resolved
SCBA FACEPIECE/REGULATOR INOPERABLE.
Condition: Unknown
Due 25 April 1998
Resolved 26 May 1998
Fire Fighting
Issued 24 April 1998
Resolved
EMERGENCY FIRE PUMP WATER/EXHAUST LEAKS._x001C_ SOLAS 60 REG I/11.
Condition: Unknown
Due 23 June 1998
Resolved 23 June 1998
Electrical
Issued 24 April 1998
Resolved
EMERGENCY GENERATOR 1.EXHAUST/RADIATOR LEAKS. _x001C_ 2.MISSING SAFETY GUARDS _x001C_ SOLAS 60 REGF I/11
Condition: Unknown
Due 23 June 1998
Resolved 23 June 1998
Accommodation/Occupational Safety
Issued 24 April 1998
Resolved
EXCESSIVE OIL ON ENGINEROOM DECKS._x001C_ ILO 147
Condition: Unknown
Due 23 June 1998
Resolved 23 June 1998
Engineering
Issued 24 April 1998
Resolved
REPLACE LUBE OIL COOLING VALVE AND PROVIDE CLASS APPROVAL FOR JACKET WATER TANK._x001C_ SOLAS 60 REG I/11
Condition: Unknown
Due 23 June 1998
Resolved 23 June 1998
Construction/Loadline
Issued 26 March 1996
Resolved
VESSEL'S CARGO HOLDS WERE MISSING TWO, HAND-HELD, PORTABLE, DRY CHEMICAL FIRE EXTINGUISHERS FOR EACH COMPARTMENT THAT CONTAINED A MOTOR VEHICLE AS REQUIRED BY 49 CFR 176.905(g).
Condition: Unknown
Due 12 April 1996
Resolved 13 April 1996
Construction/Loadline
Issued 26 March 1996
Resolved
BATTERY CABLES WERE NOT DISCONNECTED IN VEHICLES BEING STOWED IN CARGO HOLDS AS REQUIRED BY 49 CFR 176.905(c).
Condition: Unknown
Due 12 April 1996
Resolved 13 April 1996
Documentation
Issued 26 March 1996
Resolved
VESSEL DID NOT HAVE A DANGEROUS CARGO MANIFEST PREPARED FOR THE CARGO BEINGCARRIED AS REQUIRED BY 49 CFR 176.30(a).
Condition: Unknown
Due 12 April 1996
Resolved 13 April 1996
Construction/Loadline
Issued 26 March 1996
Resolved
VEHICLES BEING STOWED IN CARGO HOLDS WERE NOT LEAK FREE AS REQUIRED BY 49 CFR 176.905(b).
Condition: Unknown
Due 12 April 1996
Resolved 13 April 1996
Navigation
Issued 26 March 1996
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITH CHARTS 12326, 12327, 12333, AND 12334 NOT CORRECTED UP TO DATE AS REQUIRED BY 33 CFR 164.33(a)(1)(ii).
Condition: Unknown
Due 27 April 1996
Resolved 5 April 1996
Documentation
Issued 26 March 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 April 1996
Resolved 5 April 1996
Navigation
Issued 26 March 1996
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITHOUT A COPY OF THE TIDAL CURRENT TABLE AS REQUIRED BY 33 CFR 164.33(a)(3)(ii).
Condition: Unknown
Due 27 April 1996
Resolved 3 April 1996
Navigation
Issued 26 March 1996
Resolved
VESSEL'S ARPA UNIT DID NOT HAVE THE PERMANENTLY AFFIXED LABEL AS REQUIRED BY 33 CFR 164.38(d).
Condition: Unknown
Due 27 April 1996
Resolved 3 April 1996
Construction/Loadline
Issued 26 March 1996
Resolved
VEHICLES BEING STOWED IN CARGO HOLDS DID NOT MEET THE REQUIREMENTS OF 49 CFR 176.905(d) IN THAT EACH VEHICLE POSSESSED FUEL TANKS THAT WERE MORE THAN ONE-FOURTH FULL.
Condition: Unknown
Due 12 April 1996
Resolved 13 April 1996
Documentation
Issued 14 February 1996
Resolved
VSL'S OIL TRANSFER PROCEDURES WERE INCOMPLETE IN THAT THEY WERE MISSING THELIST OF PRODUCT'S TRANSFERRED BY GENERIC OR CHEMICAL NAME, EMERGENCY SHUTDOWN PROCEDURES AND TANK TOPPING OFF PROCEDURES.MSO LA/LB BOARDING OFFICERS ADVISED MASTER OF REQUIREMENTS AND DEFICIENCY WAS CORRECTED O/B.
Condition: Unknown
Due 14 February 1996
Resolved 14 February 1996
Accommodation/Occupational Safety
Issued 7 June 1995
Resolved
broken handrail port side AFT.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Fire Fighting
Issued 7 June 1995
Resolved
Leaking couplings on Firemain FWD STBD side.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Accommodation/Occupational Safety
Issued 7 June 1995
Resolved
Wasted Vent louvers for Engine room, at boat deck STBD side.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Fire Fighting
Issued 7 June 1995
Resolved
CO2 for Engine room fix fire fighting system, (36) bottles were empty.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Electrical
Issued 7 June 1995
Resolved
Emergency lighting in emergency escape trunk.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Construction/Loadline
Issued 7 May 1995
Resolved
Forward paint locker: properly stow all paint and solvents, repair and prove operation of the lighting, crop and renew wasted and holed aft bulkhead, 5 FT stbd of paint locker door is a eight tear in the bulkhead one foot below the overhead; prior to entry into next U.S. port.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Construction/Loadline
Issued 7 May 1995
Resolved
Install all dogs for main deck hatch leading to lower forepeak stores located inside the focsle; prior to entry into the next U.S. port.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Lifesaving
Issued 7 May 1995
Resolved
Install retro-reflective tape around the perimeter of the upper edge of thegunwale on #1 and #2 Lifeboats; prior to entry into the next U.S. port.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Lifesaving
Issued 7 May 1995
Resolved
Renew the broken bilge pump and properly connect it's suction and dischargehoses in #2 Lifeboat; prior to entry into the next U.S. port.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Fire Fighting
Issued 7 May 1995
Resolved
Conduct two year servicing of the fixed CO2 system and all portable fire extinguishers; prior to entry into the next U.S. port.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Accommodation/Occupational Safety
Issued 7 May 1995
Resolved
Permanently repair water supply to the hospital head; prior to entry into the next U.S. port.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Construction/Loadline
Issued 7 May 1995
Resolved
Prove proper operation of all dogs on the watertight door in the steering gear room; prior to entry into the next U.S. port.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Engineering
Issued 7 May 1995
Resolved
Permanently repair exhaust leak and properly insulate the exhaust piping with noncombustible insulation for the emergency fire pump engine; prior toentry into the next U.S. port.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Electrical
Issued 7 May 1995
Resolved
Permanently repair and prove auto start of the emergency generator; prior to entry into the next U.S. port.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Fire Fighting
Issued 7 May 1995
Resolved
Renew or repair fire main valve, the second valve located aft of the focslestbd side; prior to entry into the next U.S. port.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Engineering
Issued 7 May 1995
Resolved
Install corrosion resistant wire mesh flame screens in all fuel and lube oil tank vents insuring 100% fit; prior to entry into the next U.S. port.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Navigation
Issued 7 May 1995
Resolved
Fathometer readout was in question. Have checked at next dock side port call.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Navigation
Issued 7 May 1995
Resolved
Centerline RPM gage works correctly when engines are engaged however has +10 RPMs at all stop?. Have calibrated at next dock side port call.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Lifesaving
Issued 7 May 1995
Resolved
Class society (Lloyds) to examine and prove that the buoyancy chambers are not water saturated, take corrective action as required, permanently repairfractures in all buoyancy chambers in #1 and #2 Lifeboats; prior to entry into the next U.S. port.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Lifesaving
Issued 7 May 1995
Resolved
Install all required and current provisions and equipment in #1 and #2 Lifeboats; prior to entry into the next U.S. port.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995