TOKYO BAY is a 1978 freight ship. The Coast Guard has recorded 15 inspections since 1989, most recently in September 2005, along with 26 deficiencies and 1 operational control.

Records from 1989 to 2005. Most recent: inspection, 29 September 2005.

Built
1978
Last inspected
29 September 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7714521 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228448
Flag
SAINT VINCENT AND THE GRENADINES
—
Maury page id
psix-228448

Inspections, by type

…with no type recorded10
Years with a record 10 calendar years (1989–2005)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it8078 - Dead Weight, Ton
3188 - Regulatory (Subpart C or D), Net Ton
7111 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

29 September 2005 ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2504090
13 July 2004 PII Safety Exam · ISPS II Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2132080
21 April 2003 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1776103
16 April 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1774918
15 April 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1774698
20 August 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 292830
16 October 2000 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 500791
14 March 2000 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 275801
17 July 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 418067
20 August 1996 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 394283
13 August 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 394313
4 November 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 683525
27 October 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 371850
4 December 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 347406
6 February 1989 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 328366

Deficiency record · 26

Construction/Loadline › Structures › Scuttle
Issued 29 September 2005 Resolved
Repair/Replace missing dog on steering gear room scuttle and repair hole in scuttle in accordance with international convention on loadlines REG 16. To the satisfaction of Class and Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 October 2005
Resolved 6 October 2005
Resolution: Received fax from class to assess to the proper repair to the missing dog and hole in scuttle closure in steering gear room.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 29 September 2005 Resolved
Repair/Replace sewage piping in engine room that has cement patch and multiple soft patches in accordance with SOLAS 60 Chap 1 REG 11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2005
Resolved 29 October 2006
Resolution: Corrected
Navigation › Collision/Grounding Avoidance › Radar
Issued 29 September 2005 Resolved
Provide servicing report that states that radar is functioning properly in accordance with SOLAS Chap. V REG 19.2.7.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 October 2005
Resolved 5 October 2005
Resolution: rcvd fax frm radio holland, rdr is fxd
Electrical › Electrical Distribution System (service)
Issued 16 April 2003 Resolved
Breaker box for #2 steering gear motor wasted / unable to close. SOLAS 60 I/11, II/27 LEGACY COMPONENT DESC: Junction Box
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 April 2003
Resolved 17 April 2003
Engineering › Steering Gear System
Issued 16 April 2003 Resolved
Pilot control valve for #1 steering gear pump failed to operate properly. SOLAS 60 II/29 LEGACY COMPONENT DESC: Valve, Control
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 April 2003
Resolved 17 April 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 April 2003 Resolved
Excessive jacket water leak noted on #8 cylinder of the main diesel engine. SOLAS 60 I/11 LEGACY COMPONENT DESC: Cylinder Head
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 April 2003
Resolved 22 April 2003
Resolution: RCVD CLAS REPORT (DNV) ATTESTING TO SAT REPAIRS.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 April 2003 Resolved
Lagging and framework missing from #2 turbocharger of main diesel engine. SOLAS 60 I/11 LEGACY COMPONENT DESC: Turbocharger
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2003
Resolved 17 April 2003
Navigation
Issued 20 August 2001 Resolved
NO# 1 STEERING GEAR PUMP MOTOR DOES NOT OPERATE. CLASS TO VERIFY PROPER OPERATION PRIOR TO DEPARTURE FROM GULFPORT, MS.
Condition: Unknown
Due 21 August 2001
Resolved 22 August 2001
Lifesaving
Issued 20 August 2001 Resolved
LIFEJACKETS, LIGHTS AND WHISTLES NOT SOLAS APPROVED. CLASS TO ADDRESS LIFEJACKETS, LIGHTS AND WHISTLES ACCEPTABLE TO ADMINISTRATION. CITE: SOLAS 74 (AMENDED) III/7.2.1
Condition: Unknown
Due 1 September 2001
Resolved 16 April 2003
Unknown
Issued 14 March 2000 Resolved
PROVIDE ATTESTATION THAT OILY WATER SEPARATOR MEETS ADMINISTRATION REQUIREMENTS (MISSING OIL CONTENT METER).
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Unknown
Issued 14 March 2000 Resolved
REPAIR TOILETS IN HOSPITAL AND 3RD OFFICERS CABIN.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Unknown
Issued 14 March 2000 Resolved
AFFIX BELT GUARD TO COMPRESSOR IN GALLEY REEFER MACHINERY SPACE.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Unknown
Issued 14 March 2000 Resolved
REPAIR LEAK IN OVERHEAD OF HOSPITAL SPACE.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Unknown
Issued 14 March 2000 Resolved
FIX HOT WATER IN SHOWER LOCATED IN HOSPITAL SPACE.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Unknown
Issued 14 March 2000 Resolved
REPLACE FLAME SCREENS AS NEEDED ON FUEL OIL VENTS.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Unknown
Issued 14 March 2000 Resolved
PROVIDE MISSING INFORMATION ON MANEUVERING FACT SHEET.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Unknown
Issued 14 March 2000 Resolved
REPAIR LUBE OIL PURIFIERS TO SATISFACTION OF CLASS.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Unknown
Issued 14 March 2000 Resolved
FIX FRESHWATER SUPPLY TO GALLEY.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Unknown
Issued 14 March 2000 Resolved
REMOVE CEMENT PATCH FROM #3 REEFER COOLING PUMP AND REPAIR PIPE.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Unknown
Issued 14 March 2000 Resolved
REPAIR MAIN ENGINE COOLING PUMP(OVERHEATS).
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Unknown
Issued 14 March 2000 Resolved
REPAIR MAIN ENGINE COOLING PIPE.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Unknown
Issued 14 March 2000 Resolved
REPAIR STBD LIFEBOAT ENGINE TO THE SATISFACTION OF CLASS.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Unknown
Issued 14 March 2000 Resolved
PLACE PROTECTIVE MATTING BEHIND MAIN SWITCH BOARD.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Unknown
Issued 14 March 2000 Resolved
REPAIR PORT LIFEBOAT WINCH TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Navigation
Issued 27 October 1994 Resolved
VESSEL ENTERED PORT WITHOUT CHART # 1081 OR ITS EQUIVALENT.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Navigation
Issued 27 October 1994 Resolved
VESSEL DID NOT HAVE A COPY OF THE INLAND NAVIGATIONAL RULES.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.