Records from 1986 to 2006. Most recent: inspection, 24 October 2006.
Inspection history · 35
24 October 2006
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2807038
12 April 2004
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2044507
11 April 2004
Examination of Repairs · Administrative Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2041928
9 April 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2041246
27 July 2003
Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 1871307
24 July 2003
Ballast Water Examination · Security Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1855305
25 April 2002
Deficiency Check · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1607412
27 February 2002
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1489619
28 November 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 295872
15 November 2001
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 772138
13 August 2000
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 281065
8 August 2000
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 280702
13 January 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 424389
17 July 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 418226
11 April 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 413440
1 March 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 413122
28 February 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 495806
18 September 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 408036
6 August 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 406508
15 May 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 403591
3 March 1995
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 375682
28 February 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 375534
24 February 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 375513
13 September 1994
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 370332
5 July 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 368211
2 February 1994
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 535552
18 June 1993
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 359236
18 June 1992
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 441582
1 November 1991
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 346826
10 May 1991
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 540798
27 September 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 339569
11 September 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 332550
22 June 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 504078
5 August 1987
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 317716
12 July 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 310340
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 24 October 2006
No resolution recorded
Manuerving Fact sheet needs to be updated with new vessel name. 33 CFR 164.35. Action taken code: 70A
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Electrical › Lighting (emergency) › Lighting Fixture
Issued 24 October 2006
Resolved
Emergency Lighting light bulb not working properly on starboard side at lifeboat station. SOLAS 1974, Chapt III, Reg 19.A.ii. Action taken code: 10C
Due 24 October 2006
Resolved 24 October 2006
Resolution: Corrected during inspection.
Electrical › Electrical Distribution System (service) › Cable
Issued 24 October 2006
No resolution recorded
Electrical Cable run junction box very corroded presents possible shock hazard. SOLAS 1974, CHAPT II-1, REG 27. Action taken code: 70A
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Accommodation/Occupational Safety › Washroom/Toilet
Issued 27 February 2002
Resolved
Low water pressure and leaking pipes in toilets (crew and main deck). LEGACY COMPONENT DESC: Toilet
Condition: Unknown
Due 26 March 2002
Resolved 25 April 2002
Resolution: CLEARED BY MSO SAN JUAN
Construction/Loadline › Structures
Issued 27 February 2002
Resolved
Main deck aft, vertical trash bin supports badly rusted.
Condition: Improper/Lack of Maintenance
Due 26 March 2002
Resolved 25 April 2002
Resolution: CLEARED BY MSO SAN JUAN
Lifesaving
Issued 28 November 2001
Resolved
Replace 18 food rations in port and starboard lifeboats, prior to sailing.
Condition: Unknown
Due 28 November 2001
Resolved 3 December 2001
Lifesaving
Issued 28 November 2001
Resolved
Limit switches on lifeboat davits not operational, correct prior to departure.
Condition: Unknown
Due 28 December 2001
Resolved 3 December 2001
Construction/Loadline
Issued 28 November 2001
Resolved
Main deck aft, near trash storage area. lower rail course broken at roller chock. Make permanent repairs prior to 28Dec01.
Condition: Unknown
Due 28 December 2001
Resolved 25 April 2002
Resolution: CLEARED BY MSO SAN JUAN
Accommodation/Occupational Safety
Issued 28 November 2001
Resolved
Water closets not provides with ample flush of water, available at all times and independently controlled. Toilets do not flush as designed, as required by ilo 147, correct prior to 28Dec01.
Condition: Unknown
Due 28 December 2001
Resolved 25 April 2002
Resolution: CLEARED BY MSO SAN JUAN
Engineering
Issued 28 November 2001
Resolved
Oil containment for bunkering vents, on main deck, port #1 and #2 are wasted, holed. Make permanent repairs prior to 28Dec01
Condition: Unknown
Due 28 December 2001
Resolved 25 April 2002
Resolution: CLEARED BY MSO SAN JUAN
Accommodation/Occupational Safety
Issued 8 August 2000
Resolved
REPAIR REFRIGERATION SYSTEM SO THAT THE COLD STORE PROVISIONS (MEAT, FISH, AND VEGETABLES) CAN BE MAINTAINED AT THE APPROPRIATE TEMPERATURE._x001C_ _x001C_ REPAIRS TO BE MADE PRIOR TO DEPARTURE FROM NEXT U.S. PORT (PORT HUENEME).
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Lifesaving
Issued 8 August 2000
Resolved
REMOVE ALL OIL FROM BENEATH #1 & #2 MAIN DIESEL GENERATORS._x001C_ _x001C_ THIS IS TO BE COMPLETED PRIOR TO NEXT U.S. PORT (PORT HUENEME).
Condition: Unknown
Due 12 August 2000
Resolved 12 August 2000
Documentation
Issued 13 January 1999
Resolved
Provide approved vessel familiarization checklist for each crewmember priorto entry into next U.S. Port after sailing foreign. STCW 78 amd, REG. VI/1.
Condition: Unknown
Due 8 August 2000
Resolved 8 August 2000
Accommodation/Occupational Safety
Issued 11 April 1998
Resolved
Officers' / crews' heads do not flush. Repair and demonstrate proper operation at next U.S. port after sailing foreign.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Fire Fighting
Issued 1 March 1998
Resolved
EMERGENCY FIRE PUMP PRIMING BELT MISSING PROTECTIVE GUARD AS REQUIRED IN SOLAS 74 REG II-1 26.1
Condition: Unknown
Due 11 April 1998
Resolved 11 April 1998
Navigation
Issued 1 March 1998
Resolved
MISSING UP TO DATE NOTICE TO MARINERS AS REQUIRED BY 33CFR164.33C
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Fire Fighting
Issued 1 March 1998
Resolved
EMERGENCY FIRE PUMP NOT CAPABLE OF SUPPLYING A SUFFICIENT JET OF WATER FROM2 NOZZLES AS REQUIRED IN SOLAS 60 REG II 65(B)ii
Condition: Unknown
Due 1 March 1998
Resolved 12 March 1998
Construction/Loadline
Issued 18 September 1997
Resolved
Have class provide survey report on temporary cement patch of port, main sea chest and make recommendation on permanent repair. Complete prior to entry into next U.S. port. SOLAS 60 II/14.
Condition: Unknown
Due 17 October 1997
Resolved 28 October 1997
Lifesaving
Issued 15 May 1997
Resolved
THE QUICK RELEASE RING BUOYS LOCATED PORT & STARBOARD PILOTHOUSE NOT HAVINGA MASS SUFFICIENT TO OPERATE QUICK RELEASE ARRANGEMENT OR 4 KG AS PER SOLASCHAPTER III REG 31.1.7, ALL SHIPS.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Documentation
Issued 15 May 1997
Resolved
UPDATE EXISTING SHIPBOARD OIL POLLUTION EMERGENCY PLAN AND SUBMIT TO THE SATISFACTION OF THE CLASS SOCIETY.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Engineering
Issued 24 February 1995
Resolved
OIL TRANSFER PROCEDURES MISSING MEANS OF COMMUNICATION, EMPTYING CONTAINMENT AND PRODUCTS TRANSFERED.
Condition: Unknown
Due 28 February 1995
Resolved 28 February 1995
Engineering
Issued 24 February 1995
Resolved
NO MECHANICAL MEANS OF CLOSURE ON SMALL FO/LO CONTAINMENT.
Condition: Unknown
Due 28 February 1995
Resolved 28 February 1995
Navigation
Issued 24 February 1995
Resolved
HARBOR CHART NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Documentation
Issued 18 June 1993
Resolved
DANGEROUS CARGO MANIFEST NOT KEPT ON BRIDGE IN DESIGNATED HOLDER AS REQUIRED.
Condition: Unknown
Due 3 March 1994
Resolved 3 March 1994
Navigation
Issued 18 June 1993
Resolved
COAST PILOT FOR AREA TRANSITED NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 15 September 1994
Resolved 15 September 1994
Navigation
Issued 18 June 1993
Resolved
CHART FOR AREA TRANSITED NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 15 September 1994
Resolved 15 September 1994
Documentation
Issued 18 June 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 15 September 1994
Resolved 15 September 1994
Documentation
Issued 18 June 1993
Resolved
DANGEROUS CARGO MANIFEST DOES NOT HAVE AN EMERGENC RESPONSE TELEPHONE NUMBER AS REQUIRED.
Condition: Unknown
Due 3 March 1994
Resolved 3 March 1994
Documentation
Issued 1 November 1991
Resolved
The vessel's oil transfer procedures did not contain a description of and procedures for emptying the discharge containment system as required by 33CFR155.750(a)(2)(iii).
Condition: Unknown
Due 4 November 1991
Resolved 4 November 1991
Navigation
Issued 1 November 1991
Resolved
NOAA chart #18725, 22nd edition was missing Notice to Mariners corrections from Dec. 5, 1987 through Dec. 31, 1990. The vessel had no foreign equivalents on board.
Condition: Unknown
Due 4 November 1991
Resolved 4 November 1991
Documentation
Issued 5 August 1987
Resolved
CAPT OF VESSEL FAILED TO SIGN THE DCM.
Condition: Unknown
Due 5 August 1987
Resolved 5 August 1987
Navigation
Issued 12 July 1986
Resolved
VESSEL FAILED TO CONDUCT AN EMERGENCY STEERING DRILL ON A REGULAR BASIS AT LEAST ONCE EVERY 3 MONTHS OR WITHIN 48 HOURS PRIOT TO ENTRY IN U.S. WATERS.
Condition: Unknown
Due 22 June 1988
Resolved 12 July 1986
Navigation
Issued 12 July 1986
Resolved
VESSEL HAD THE FOLLOWING CHART DEFICIENCIES: #18521 ED.55 CORRECTED ONLY FROM NOTICE TO MARINER 1-23/86, #18523 ED.42 CORRECTED ONLY FROM NTM 1-23/86, #18524 ED.22 CORRECTED ONLY FROM NTM 50/85-23/86, #18526 ED.43 CORRECTED ONLY FROM NTM 23/86.
Condition: Unknown
Due 12 July 1986
Resolved 12 July 1986