← All vessels
LEVANTE
Freight Ship · General Dry Cargo Ship class · Built 1970s · USCG Heartland District (CGD-H) · Other hulls named LEVANTE
LEVANTE is a 1978 freight ship. The Coast Guard has recorded 15 inspections since 1984, most recently in July 2002, along with 34 deficiencies and 1 operational control.
Records from 1984 to 2002. Most recent: operational control imposed, 3 July 2002.
- Built
- 1978
- Last inspected
- 3 July 2002
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 34 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7720740 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
P3RB6
228531
Flag
SOUTH KOREA
—
Maury page id
psix-228531
Inspections, by type
The 15 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it19395 - Dead Weight, Ton
6870 - Regulatory (Subpart C or D), Net Ton
12318 - Regulatory (Subpart C or D), Gross Ton
6870 - Regulatory (Subpart C or D), Net Ton
12318 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 15
3 July 2002
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1640831
26 June 2002
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1636912
20 June 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1634160
9 May 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 289918
30 April 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 289624
20 July 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 430752
12 May 1999
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 428387
4 May 1999
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 427801
24 February 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 401013
31 July 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 324690
8 October 1986
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 311929
23 September 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 311585
9 July 1985
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 303019
26 June 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 302779
9 August 1984
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 297486
Deficiency record · 34
Navigation › Piloting/Steering
Issued 3 July 2002
Resolved
Vessel experienced an inoperable gyrocompass. LEGACY COMPONENT DESC: Gyro Compass
Fire Fighting › Fire Main
Issued 20 June 2002
Resolved
Fire Main piping running fwd on port side deck next to center cargo hold is leaking. Resulting in inadequate pressure. Repairs are to be made prior to vessel departure. Vessel detained. LEGACY COMPONENT DESC: Condition
Fire Fighting › Nozzles
Issued 20 June 2002
Resolved
Improper nozzle was installed on fire hose inside engine room lower level. Nozzle needs to be replaced with vari-type vice straight stream. LEGACY COMPONENT DESC: Type
Fire Fighting
Issued 20 June 2002
Resolved
Crew had great trouble conducting fire drill. No communication skills. Crew members unable to work together. Crew members need to practice ship's fire drill procedures.
Pollution Prevention/Response › Prevention Equipment
Issued 20 June 2002
Resolved
Type II MSD sewage tank cracked and leaking onto engine room deck. Make repair and ensure proper operation. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Pollution Prevention/Response › Prevention Equipment
Issued 20 June 2002
Resolved
OWS system will not properly operate. It's auto stopping device and monitoring sensors are disabled. Repairs must be made prior to vessel departure. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Pollution Prevention/Response › Prevention Equipment
Issued 20 June 2002
Resolved
Garbage onboard ship is not properly segregated as per ships' "Waste Management Plan". Garbage needs to be remove completely and then using management plan start separating all trash and garbage.
Lifesaving › Lifebuoys
Issued 20 June 2002
Resolved
05 life ring buoys are rotted and unfit for service. These need to be renewed and placed back in proper service. LEGACY COMPONENT DESC: Stowage
Lifesaving
Issued 20 June 2002
Resolved
Crew did not properly muster in a timely manner for abandon ship drill and are not familiar with their assigned duties. Crew members also were not able to communicate with each other to make drill run smoothly.
Accommodation/Occupational Safety
Issued 20 June 2002
Resolved
Water tight doors at the entrance to the galley, and both storage rooms on deck between cargo holds are warped and have damaged dogging devices. Doors also need new gaskets to ensure a weather tight closing.
Accommodation/Occupational Safety › Occupational Safety
Issued 20 June 2002
Resolved
Steel entrance and exit ladder inside #1 cargo hold has missing rungs at lower bottom level. Possible this would prevent quick escape from inside hold onto main deck. Replace missing rungs.
Deck/Cargo › Holds/Tanks
Issued 20 June 2002
Resolved
Unauthorized paints and other flammables stowed in engine room, various storage rooms throughout ship and in forward focsle space.
Fire Fighting
Issued 30 April 2001
Resolved
Repair exhaust leak at emergency fire pump IAW SOLAS 74amd II-2/21 to satisfaction of Certificate Issuing Authority.
Engineering
Issued 12 May 1999
Resolved
INSULATION WET AND BURNING ON EMERGENCY FIRE PUMP.
Electrical
Issued 12 May 1999
Resolved
NO COVER FOR BATTERIES FOR EMERGENCY FIRE PUMP.
Navigation
Issued 12 May 1999
Resolved
NO CURRENT COAST PILOT FOR 1999.
Navigation
Issued 12 May 1999
Resolved
LIGHT LIST NOT UPDATED.
Navigation
Issued 12 May 1999
Resolved
NO TIDAL CURRENT TABLES.
Fire Fighting
Issued 4 May 1999
Resolved
While conducting a test of the fire system, it was observed that the battery system for the emergency fire pump was shorted, which prevented thepump from starting. Chief engineer removed two batteries from battery roomto operate pump. Specific Cite: Solas 74 (amended) CH.II-2/Reg.21
Electrical
Issued 4 May 1999
Resolved
While conducting a walk through, it was observed that globes and protectivecages were missing in several areas. ie>bridge, alternator room on bridge, A/C room, STBD life boat deck, oiler A & B accommodations and hospital. Specific Cite: Solas 60 Ch.II/Reg.27(a).
Electrical
Issued 4 May 1999
Resolved
While inspecting the battery room and the room behind the engine control room, it was observed that rubber matting was missing to prevent electricalshock to crewmembers [name withheld]: Solas 60 CH.II/Reg.27(a).
Documentation
Issued 4 May 1999
Resolved
While conducting a test on the oily water seperator, it was observed that the oil discharge placard ws missing. Specific Cite: 33 CFR 155.450(a)
Lifesaving
Issued 4 May 1999
Resolved
while conducting the abandon ship drill, it was observed that the arrangement for the pennant and tiping line did not correspond with the instructions posted. The arrangement presented could pose a threat to the crew if used. Solas 74(amended) CH.III/Reg.13.
Electrical
Issued 4 May 1999
Resolved
While inspecting the vent closure device to the battery room, it was observed that the vent would not seal properly due to wastage. Proper sealing is required to inhibit oxygen to the room on case of fire. Specific Cite: Solas 60 Ch. II/Reg. 47(a).
Electrical
Issued 4 May 1999
Resolved
While conducting a vessel walk through, it was observed that in the Alternator room located on the bridge and the electrical locker, located onthe 02 deck, contained combustible material. Specific Cite: Solas 60 CH II/Reg 343.
Lifesaving
Issued 24 February 1997
Resolved
VESSEL'S STARBOARD MOTOR LIFEBOAT ENGINE DID NOT START. SOLAS 74 CH. III, REG 41. DEFICIENCY WAS CORRECTED WHILE BOARDING OFFICERS WERE ON BOARD. OPERATED AHEAD AND ASTERN SATISFACTORILY.
Navigation
Issued 23 September 1986
Resolved
1981 BRITISH ADMIRALTY LIGHT LIST VOLUME J ONBOARD NOT CORRECTED UP TO DATE. PUBLICATION REQUIRED TO BE CORRECTED UP TO DATE. NO OTHER LIGHT LIST OR EQUIVALENT ONBOARD.
Navigation
Issued 23 September 1986
Resolved
1986 U.S. COAST PILOT ONBOARD NOT CORRECTED UP TO DATE. PUBLICATION RE- QUIRED TO BE CORRECTED UP TO DATE. NO FOREIGN EQUIVALENT ONBOARD
Navigation
Issued 23 September 1986
Resolved
CHARTS 12326,12335,AND 12349 ONBOARD NOT CORRECTED UP TO DATE. CHARTS RE- QUIRED TO BE CORRECTED UP TO DATE THROUGH LATEST NOTICE TO MARINERS. NO FOREIGN EQUIVALENTS ONBOARD.
Navigation
Issued 9 July 1985
Resolved
EQUIPMENT TESTS AS REQUIRED BY 33 CFR 164.11 (Q) WERE NOT PERFORMED AND LOGGED PRIOR TO ENTERING PORT ON 09 JULY 1985. CAPTAIN OF THE M/V KOREAN ZIRCON HAS BEEN ADVISED OF THE INTERPRETATION OF REGULATIONS, AND WILL COMPLY.
Deck/Cargo
Issued 26 June 1985
Resolved
DISCHARGE OF OIL PROHIBITED PLACARD 33 CFR 155.450
Navigation
Issued 26 June 1985
Resolved
CHARTS NOT CURRENT OR CORRECTED 33 CFR 164.33 (A)(1)(II) COAST PILOT NOT CURRENT 33 CFR 164.33 (A)(2)(I) LIGHT LIST NOT CURRENT 33 CFR 164.33 (A)(2)(II)
Documentation
Issued 9 August 1984
Resolved
VESSEL DID NO HAVE A NEW OIL RECORD BOOK IAW MARPOL 73/78.
Navigation
Issued 9 August 1984
Resolved
VESSEL DID NOT HAVE A LIGHT LIST AS REQUIRED.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.