Records from 1985 to 2009. Most recent: operational control imposed, 4 April 2009.
Inspection history · 9
4 April 2009
ISPS II Exam · PI Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3446057
2 April 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3445076
22 June 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 429844
5 September 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 407512
29 August 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 407252
1 July 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 392866
9 May 1994
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 498964
27 December 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 363512
26 August 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 303898
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 4 April 2009
Resolved
The self closing fire doors that lead to the steering gear and engine room do not self close. Vessel shall remove all tie backs on self closing fire doors and verify that all self closing fire doors self close.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2009
Resolution: Received satisfactory class report.
Fire Fighting › Grease Extraction Hood › General
Issued 4 April 2009
Resolved
The hood located above the stove in the galley is missing both filters. The vessel shall clean the ducts in the overhead and install filters.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2009
Resolution: Received satisfactory class report.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 4 April 2009
Resolved
The Galley is infested with bugs. The vessel shall provide proof of extermination.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2009
Resolution: Received fumigation certificate.
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 4 April 2009
Resolved
The vessel's sludge discharge system does not match the vessel's approved drawing, additional connections on both the suction and discharge side of the pump are not reflected on the drawing. The vessel must either update the drawing or return the system to its original approved design.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2009
Resolution: Received satisfactory class report.
Engineering › Diesel Engine (auxiliary) › Waste Heat Recovery
Issued 4 April 2009
Resolved
The vessel's #1 generator has a cooling water leak. The vessel must repair leak.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2009
Resolution: Received satisfactory class report.
Engineering › Diesel Engine (auxiliary) › Governor
Issued 4 April 2009
Resolved
The vessel's #2 generator has multiple fuel oil leaks on broken fuel return lines. Vessel must repair broken return lines.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2009
Resolution: Received satisfactory class report.
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (electric)
Issued 4 April 2009
Resolved
The vessel's #2 generator's starter solenoid is housed in a bucket on top of the engine. Vessel shall install a bracket or a means to properly secure the electrical solenoid to prevent shock hazard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2009
Resolution: Received satisfactory class report.
Documentation
Issued 22 June 1999
No resolution recorded
PROVIDE ONBOARD CARGO SECURING MANUAL APPROVED BY CLASS OR ALGERIAN GOVERNMENT._x001C_ SOLAS 74 AMMENDED VI/5.6
Condition: Unknown
Due 22 July 1999 — due date passed with no resolution recorded
Documentation
Issued 22 June 1999
No resolution recorded
PROVIDE ON BOARD VESSEL UPDATED SAFETY EQUIPMENT CERTIFICATE SHOWING ALL PERTINENT LIFESAVING APPLIANCES._x001C_ SOLAS 74 (AMENDED) ANNEX 3.3
Condition: Unknown
Due 23 June 1999 — due date passed with no resolution recorded
Fire Fighting
Issued 22 June 1999
Resolved
PROVIDE ONBOARD ONE COMPLETE FIREFIGHTING, SOLAS APPROVED, SUIT. _x001C_ SOLAS74 (AMENDED) II-2/17.3_x001C_
Condition: Unknown
Due 23 June 1999
Resolved 23 June 1999
Fire Fighting
Issued 29 August 1997
Resolved
A VIO OF SOLAS IN THAT THE VSL DID NOT HAVE ON BOARD A SECOND FIREMAN'S OUTFIT.
Condition: Unknown
Due 8 September 1997
Resolved 8 September 1997
Navigation
Issued 29 August 1997
Resolved
A VIO OF 33 CFR 164.33 IN THAT THE VSL WAS MISSING THE SUPPLEMENT TO THE BACOAST PILOT VOL69._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 August 1998
Resolved 2 September 1997
Lifesaving
Issued 29 August 1997
Resolved
A VIO OF SOLAS IN THAT THE VSL WAS MISSING TWO WATER LIGHTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 September 1997
Resolved 2 September 1997
Documentation
Issued 1 July 1996
Resolved
VESSEL DID NOT HAVE THE FIREMANS OUTFITS MARKED ON THE FIRE CONTROL PLAN ASREQUIRED BY SOLAS CHAP. II-2 REG 20.
Condition: Unknown
Due 5 July 1996
Resolved 2 July 1996
Navigation
Issued 1 July 1996
Resolved
VESSELS MARINE RADAR DID NOT FUNCTION PROPERLY AS REQUIRED BY 33 CFR 164.53.
Condition: Unknown
Due 5 July 1996
Resolved 2 July 1996
Navigation
Issued 1 July 1996
Resolved
VESSEL DID NOT HAVE CURRENTLY CORRECTED CHARTS FOR BOTH GALVESTON AND HOUSTON AREAS TO BE TRANSITED AS REQUIRED BY 33 CFR 164.35.
Condition: Unknown
Due 5 July 1996
Resolved 2 July 1996
Documentation
Issued 1 July 1996
Resolved
VESSELS OIL TRANSFER PROCEDURES NEED TO BE UPDATED AS REQUIRED BY 33 CFR 155.740.
Condition: Unknown
Due 5 July 1996
Resolved 2 July 1996
Accommodation/Occupational Safety
Issued 1 July 1996
Resolved
CREWMEMBER USING THE HOSPITAL SPACE AS LIVING QUARTERS. PROHIBITED BY ILO 147.
Condition: Unknown
Due 5 July 1996
Resolved 2 July 1996
Navigation
Issued 27 December 1993
Resolved
MANEUVERING FACT SHEET WAS MISSING THE INFORMATION FOR 90 DEGREE TURNING CIRCLE DIAGRAM.
Condition: Unknown
Due 9 May 1994
Resolved 9 May 1994
Navigation
Issued 27 December 1993
Resolved
maneuvering fact sheet was missing the information for time and distance tostop.
Condition: Unknown
Due 9 May 1994
Resolved 9 May 1994
Documentation
Issued 26 August 1985
Resolved
33 CFR 155.720 NO OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 26 August 1985
Resolved 26 August 1985
Deck/Cargo
Issued 26 August 1985
Resolved
33 CFR 151.25 OIL RECORD BOOK WAS NOT MAINTAINED PROPERLY AS REQUIRED BY THIS REGULATION.
Condition: Unknown
Due 26 August 1985
Resolved 26 August 1985