MAURY USCG vessel records Sign in
← All vessels

SAPPHIRE I

SAPPHIRE I is a 1980 freight ship. The Coast Guard has recorded 29 inspections since 1985, most recently in April 2009, along with 36 deficiencies and 7 operational controls.

Records from 1985 to 2009. Most recent: inspection, 13 April 2009.

Built
1980
Last inspected
13 April 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7722152 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228550
Flag
PANAMA
—
Maury page id
psix-228550

Inspections, by type

…with no type recorded20
Years with a record 19 calendar years (1985–2009)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it21579 - Displacement, Ton
17168 - Dead Weight, Ton
5657 - Regulatory (Subpart C or D), Net Ton
5657 - Convention (Subpart B), Net Ton
10322 - Regulatory (Subpart C or D), Gross Ton
10322 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 29

13 April 2009 Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3448422
9 April 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3448340
7 April 2009 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3448235
18 February 2009 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3419926
22 November 2008 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3367689
4 September 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3317816
1 May 2008 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3196437
11 September 2007 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3054932
22 February 2006 PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2589127
19 September 2005 Deficiency Check · PI Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2493220
1 February 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1743569
14 January 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1729109
10 August 2001 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 292695
4 March 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 400760
18 October 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 396477
10 May 1996 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 391040
16 August 1995 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 382431
1 May 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 377717
28 December 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 373678
28 December 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 851566
18 May 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 358306
13 May 1993 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 358238
23 February 1992 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 348969
5 June 1991 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 504668
30 November 1990 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 340625
6 November 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 333711
25 April 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 322867
12 March 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 314784
10 May 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 301904

Deficiency record · 36

Lifesaving › Launching Appliances › Release Mechanism
Issued 4 September 2008 Resolved
0636- The gravity break for the Starboard and Port Side life boats are inoperable. During the lifeboat drill on the port side the gravity break did not engage. The port side gravity break could not be tested due to the accommodation ladder hanging under the life boat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2008
Resolved 6 September 2008
Resolution: Houston Port State Control Officers witness retest of portside & starboard side gravity breaks. The deficiency has been rectified.
Construction/Loadline › Markings › Load Line Assigning Authority Mark
Issued 11 September 2007 Resolved
The mark of assigning authority was "AB" instead of "PR" (which is what's on their ILLC). Repairs to be made to the satisfaction of class (ILLC 66 I/7).
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 May 2008
Resolution: 01MAY08: recieved a letter for Panama [name withheld] stating that "the load lines assigned have been marked in accordance with the international convention on load lines, 1966" "Furthermore I confirm that the letters P and R have been marked in agm
Documentation › Logs/Records › Ballast Water Reporting Form
Issued 11 September 2007 Resolved
Vessel failed to comply with ballast water reporting requirements (33CFR 151.2041).
Due 11 September 2007
Resolved 11 September 2007
Resolution: Master was educated on requirements, and report was sent to NBIC.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 11 September 2007 Resolved
Vessel had exposed metal filament from the forth lighting assembly. All other light bulbs were energized in the circuit which created a live electrical hazard (60 SOLAS II/27).
Due 11 September 2007
Resolved 11 September 2007
Resolution: Vessel electrician removed hazard, replaced light bulb, and installed new lens and lens guard.
Construction/Loadline › Structures › Ventilators
Issued 11 September 2007 Resolved
The overhead in provision stores shows signs of wastage and corrosion. Specifically on the underside of the ventilator. Repairs to be made to the satisfaction of class (60 SOLAS II/17b).
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 May 2008
Resolution: Recived class report attesting the necessary repair of vent trunk in dry goods storage as well as the vent tunk closing on deck has been carried out and found in order.
Engineering › Bilge Water Management System › Not Operational
Issued 19 September 2005 Resolved
OILY WATER SEPERATOR IS INOPERATIVE
Action required: 15 - Rectify deficiencies by next port
Due 3 October 2005
Resolved 22 February 2006
Resolution: Oily Water Separator has been replaced and found in working condition.
Navigation › Piloting/Steering
Issued 14 January 2003 Resolved
U.S. Coast Pilot or foreign equivalent (B.A. Vol. 69), not currently corrected to latest Notice of Mariners. 33 CFR 164.33(2)(i)(b). Correct prior to departure from port. LEGACY COMPONENT DESC: US Coast Pilot
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 January 2003
Resolution: Conducted deficiency check. Observed latest updates to B.A. Vol. 69 had been properly made in accordance with latest Notice to Mariners.
Navigation › Piloting/Steering
Issued 14 January 2003 Resolved
Vessel missing 2003 Tide/Tidal Current Tables. 33 CFR 164.33 (a)(3)(i)(b). Correct prior to departure from port. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 January 2003
Resolution: Received a faxed copy of a receipt confirming purchase of 2003 Tide/ Tidal Current Tables by ship''s agent, with ship''s stamp and Captian''s signature attesting to delivery.
Construction/Loadline › Hull › Hull Plating
Issued 14 January 2003 Resolved
Hull upper transom at stern of vessel is wasted through, at (04) small areas, just above the stern anchore housing chamber. ICLL 66 Annex 1/1. Correct at next drydock. LEGACY COMPONENT DESC: Side Shell
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 February 2004
Resolved 19 September 2005
Personnel › Certificates/Documents/Licenses
Issued 14 January 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 January 2003
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving › Lifeboat Equipment
Issued 14 January 2003 Resolved
Starboard lifeboat missing 01 jack-knife. Solas 60, Ch. III, Reg. II (a) (xx). Correct prior to departure from port. LEGACY COMPONENT DESC: Knife/Jack-knife
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 January 2003
Resolution: Received a faxed copy of a receipt for 01 multi-purpose tool/jack-knife for starboard lifeboat from ship''s agent.
Lifesaving › Launching Appliances
Issued 14 January 2003 Resolved
Starboard lifeboat lowering handle is inoperable. Solas 60, CH. III, Reg. 36 (c). Correct prior to departure from port. LEGACY COMPONENT DESC: Release Mechanism
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 January 2003
Resolution: Conducted deficiency check. Observed proper operation of lowering arm and lowering/raising of starboard lifeboat.
Deck/Cargo
Issued 18 October 1996 Resolved
Repair the leaking deck hydraulic systems on the bow & stern. Clean oil from the decks to prevent entry into the water. Complete prior to return to a U. S. port. _x001C_ 33 CFR 151.10.b
Condition: Unknown
Due 5 March 1997
Resolved 5 March 1997
Construction/Loadline
Issued 18 October 1996 Resolved
Repair the wasted & leaking ballast vent pipes in the tunnels. Note in particular, the vent line aft of FM 116 on the port side. Complete prior to return to a U. S. port. _x001C_ SOLAS 60 I/10
Condition: Unknown
Due 28 October 1996
Resolved 28 October 1996
Fire Fighting
Issued 18 October 1996 Resolved
Remove the hold back hook on the fire door to the steering gear space from the engineroom. Complete prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/42
Condition: Unknown
Due 28 October 1996
Resolved 28 October 1996
Fire Fighting
Issued 18 October 1996 Resolved
Make permanent repairs to the wasted & holed firemain about the emergency fire pump. The line has two patches on the discharge and at the penetration through the overhead. Complete prior to departure. _x001C_ SOLAS 60 II/56.c
Condition: Unknown
Due 5 March 1997
Resolved 5 March 1997
Fire Fighting
Issued 18 October 1996 Resolved
Make permanent repairs to the holed CO2 piping in the CO2 room. The pipe to #3 cargo hold is wasted below the valve. Have class assure entire length of pipe to the hold is in satisfactory condition. Complete prior toreturn to a U. S. port. SOLAS 60 II/58.b
Condition: Unknown
Due 28 October 1996
Resolved 28 October 1996
Engineering
Issued 18 October 1996 Resolved
Repair the wasted piping about the heat exchanger to the emergency generator engine. There are numerous leaks and patches (welded, glass wrap). Complete prior to return to a U. S. port. _x001C_ SOLAS 60 II/26.a
Condition: Unknown
Due 5 March 1997
Resolved 5 March 1997
Engineering
Issued 18 October 1996 Resolved
Determine if repairs to expansion joint on emergency generator engine heat exchanger are acceptable. Repair / replace if necessary prior to return toa U. S. port. _x001C_ SOLAS 60 II/26.a
Condition: Unknown
Due 31 October 1996
Resolved 28 October 1996
Engineering
Issued 18 October 1996 Resolved
Repair the wasted line on the last stage of the O.W.S. prior to return to aU. S. port. _x001C_ _x001C_ MARPOL 73/78 I/16
Condition: Unknown
Due 28 October 1996
Resolved 28 October 1996
Deck/Cargo
Issued 18 October 1996 Resolved
Repair the wasted cooling piping in the stbd pipe tunnel. Investigate areas about frames 64 and aft of 146. Complete prior to return to a U. S. port. _x001C_ SOLAS 60 I/10
Condition: Unknown
Due 5 March 1997
Resolved 5 March 1997
Electrical
Issued 10 May 1996 Resolved
INSTALL PROTECTIVE COVERS ON LIGHTS THROUGHOUT ENGINEERING SPACES IN _x001C_ ACCORDANCE WITH SOLAS CHAPTER II-1 REGULATION 40.1.3.
Condition: Unknown
Due 28 October 1996
Resolved 28 October 1996
Navigation
Issued 10 May 1996 Resolved
PROVIDE NON-SLIP SURFACE IN AFTER STEERING SPACE IN ACCORDANCE WITH SOLAS_x001C_ CHAPTER II-1 REGULATION 29.13.2.
Condition: Unknown
Due 28 October 1996
Resolved 28 October 1996
Electrical
Issued 10 May 1996 Resolved
INSTALL PROTECTIVE COVER ON BARE LIGHT BULB IN ACCOMMODATION FAN ROOM IN_x001C_ ACCORDANCE WITH SOLAS CHAPTER II-1 REGULATION 40.1.3.
Condition: Unknown
Due 10 May 1996
Resolved 10 May 1996
Lifesaving
Issued 1 May 1995 Resolved
REPLACE WASTED BILGE PUMP HOSE OF PORT LIFEBOAT.
Condition: Unknown
Due 1 May 1995
Resolved 1 May 1995
Navigation
Issued 1 May 1995 Resolved
OBTAIN CHARTS #12248 AND #12251.
Condition: Unknown
Due 1 May 1995
Resolved 1 May 1995
Engineering
Issued 1 May 1995 Resolved
REPLACE WASTED/DIRTY FLAME SCREENS ON FUEL OIL VENTS LOCATED ON FORCASTLE PORT AND STARBOARD SIDES AND BETWEEN CARGO HOLDS #4 AND #5 ON THE CENTER LINE.
Condition: Unknown
Due 28 October 1996
Resolved 28 October 1996
Lifesaving
Issued 1 May 1995 Resolved
PLACE PROTECTIVE LIGHT COVERS ON TWO LIGHTS IN THE PIPE TUNNEL STARBOARD SIDE._x001C_ SOLAS 60 II/27
Condition: Unknown
Due 28 October 1996
Resolved 28 October 1996
Documentation
Issued 28 December 1994 Resolved
The vessel was in violation of SOLAS chapter V, regulation 13 when the Vessel was not manned IAW the Safe Manning Certificate. The chief mate hadno license onboard.
Condition: Unknown
Due 29 December 1994
Resolved 29 December 1994
Navigation
Issued 6 November 1989 Resolved
CHART 18523, EDITION 43 / DATED 29APR89, NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 30 December 1994
Resolved 30 December 1994
Navigation
Issued 6 November 1989 Resolved
CHART 18524, EDITION 23 / DATED 09JUL88, NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 30 December 1994
Resolved 30 December 1994
Navigation
Issued 6 November 1989 Resolved
U.S. COAST PILOT VOLUME 7, 1988 EDITION, NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 30 December 1994
Resolved 30 December 1994
Navigation
Issued 6 November 1989 Resolved
COAST GUARD LIGHT LIST VOLUME VI, 1989 EDITION, NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 30 December 1994
Resolved 30 December 1994
Navigation
Issued 6 November 1989 Resolved
CHART 18521, EDITION 56 / DATED 19SEP87, NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 30 December 1994
Resolved 30 December 1994
Navigation
Issued 6 November 1989 Resolved
INLAND NAVIGATION RULES NOT ON BOARD.
Condition: Unknown
Due 19 May 1993
Resolved 19 May 1993
Documentation
Issued 6 November 1989 Resolved
OIL TRANSFER PROCEDURES INCOMPLETE.
Condition: Unknown
Due 19 May 1993
Resolved 19 May 1993

Ownership record