MAURY USCG vessel records Sign in
← All vessels

CAPE HENRY

CAPE HENRY is a 1979 freight ship. The Coast Guard has recorded 160 inspections since 1984, most recently in November 2025, along with 151 deficiencies, 2 operational controls and 7 casualty investigations between 2003 and 2025.

Records from 1984 to 2025. Most recent: inspection, 17 November 2025.

Built
1979
Last inspected
17 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7724083 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228566
Flag
UNITED STATES
303943000 (licence lapsed)
Maury page id
psix-228566

Inspections, by type

…with no type recorded63
Years with a record 37 calendar years (1984–2025)
The 160 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Registered dimensions (L × B × D)693.9 ft × 105.8 ft × 66.3 ft
Registered tonnagegross 39,889 / net 13,505
ITC dimensions (L × B × D)693.9 ft × 105.8 ft × 66.3 ft
ITC tonnagegross 39,889 / net 13,505
BuilderMITSUBISHI HEAVY INDUSTRY · NAGASAKI, JAPAN · built 1979
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNORFOLK, VA
Trade endorsementsRegistry
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it36836 - Dead Weight, Ton
51836 - Displacement, Ton
13505 - Convention (Subpart B), Net Ton
39889 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

KMJHMMSI 303943000 · expired · compulsorily equipped · granted 10 September 1998, cancelled 7 February 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GEMINI II Passenger (Inspected) · MISLE 407045 · 20 August 1994 · activity 148374

Inspection history · 160

17 November 2025 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8270074
18 July 2025 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8188559
28 May 2025 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8145886
25 May 2025 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8144653
5 February 2025 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8074861
2 February 2025 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8074194
27 January 2025 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8070497
30 December 2024 Annual Inspection · ACP Annual Oversight · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8043361
4 December 2024 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8043166
15 February 2024 ACP Drydock Oversight · Re-Inspection · ACP COI Oversight · MTSA/ISPS Verification
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7865078
5 November 2023 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7836047
26 July 2023 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7753919
14 July 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7742229
14 July 2023 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7742499
3 July 2023 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7745115
7 May 2023 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7684180
1 May 2023 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7685728
20 April 2023 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7674718
20 April 2023 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7685327
15 March 2023 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7653347
3 January 2023 ACP Annual Oversight · In-Service Inspection · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7615873
15 March 2022 Deficiency Check · Periodic Inspection · Administrative Inspection · ACP Periodic Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7412059
16 November 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7352037
13 April 2021 Annual Inspection · ACP Annual Oversight · In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7174535
2 September 2020 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7047733
28 May 2020 In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6968896
14 April 2020 ACP Annual Oversight · Examination of Repairs · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6948836
12 August 2019 Examination of Repairs · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6781464
22 January 2019 Administrative Inspection · COI Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6611983
17 August 2018 Drydock Exam · ACP Drydock Oversight
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6514848
27 July 2018 In-Service Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6491762
15 May 2018 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6385037
25 April 2018 ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6416453
20 September 2017 Annual Inspection · ACP Annual Oversight · Administrative Inspection · Periodic Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6270696
24 April 2017 MTSA/ISPS Verification · Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6131326
19 April 2016 ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5857507
22 May 2012 ACP Annual Oversight · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4421072
8 July 2011 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4074483
31 January 2011 MTSA/ISPS Verification · Periodic Inspection · ACP Annual Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3936295
28 January 2009 MTSA Verification · ACP COI Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3396867
31 July 2008 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3285091
7 May 2008 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3200814
27 February 2008 ACP Annual Oversight
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3131410
2 May 2007 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2924162
1 May 2007 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2919775
12 March 2007 ACP Periodic Oversight · MTSA/ISPS Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2887890
7 March 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2597767
6 February 2006 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2560919
6 February 2006 MTSA/ISPS Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2574711
26 October 2005 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2522847
1 August 2005 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2555421
12 May 2005 MTSA/ISPS Verification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2337197
18 January 2005 Construction Oversight
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2277566
22 December 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2263620
13 December 2004 Annual Inspection · Construction Oversight
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2250084
19 August 2004 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2170150
9 July 2004 In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2127557
3 June 2004 MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2087461
31 May 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2084417
29 May 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2082287
23 April 2004 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2622141
3 February 2004 COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1990159
28 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1995616
2 July 2003 Administrative Inspection
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1833155
6 March 2003 Type not recorded
No type recorded · Activities Europe · Activity 1759922
27 January 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1736123
4 December 2002 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1714015
5 November 2002 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1711372
7 October 2002 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1685790
8 August 2002 Internal Structural Exam · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1658644
17 January 2002 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1479743
20 November 2001 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1076848
15 November 2001 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1401602
31 August 2000 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 823866
4 August 2000 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1467686
4 April 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1047383
20 December 1999 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1047789
2 December 1999 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1397302
1 March 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 809812
22 February 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 795818
24 November 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1471541
14 November 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 167002
23 July 1998 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 798049
2 July 1998 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1130583
5 June 1998 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1129733
20 May 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 171820
27 April 1998 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 790430
16 April 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 789333
11 February 1998 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 775384
31 December 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 786319
29 December 1997 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 790434
19 December 1997 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1424505
2 October 1997 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 785120
4 September 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1368393
8 August 1997 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1437282
25 July 1997 Administrative
Administrative · Activities Europe · Activity 1116686
17 May 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 139977
9 May 1997 Administrative
Administrative · Activities Europe · Activity 1102086
21 April 1997 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 63379
27 March 1997 Deficiency Check
Physical examination · Activities Europe · Activity 1097829
17 March 1997 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 449305
16 March 1997 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1099431
24 November 1996 Drydock Extension · Re-Inspection
Physical examination · Activities Europe · Activity 1424299
16 November 1996 Type not recorded
No type recorded · Activities Europe · Activity 136338
27 October 1996 Type not recorded
No type recorded · Activities Europe · Activity 142420
19 September 1996 Administrative
Administrative · Activities Europe · Activity 827316
1 August 1996 Type not recorded
No type recorded · Activities Europe · Activity 127941
31 July 1996 Deficiency Check
Physical examination · Activities Europe · Activity 1087818
26 July 1996 Type not recorded
No type recorded · Activities Europe · Activity 167498
5 February 1996 COI Inspection
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1193678
1 December 1995 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 115835
11 November 1995 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 155418
5 May 1995 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6760
4 April 1995 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 76709
15 February 1995 Re-Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1167796
20 September 1994 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 178654
20 August 1994 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 148374
22 July 1994 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 56655
17 July 1994 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 154192
13 July 1994 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 71780
29 May 1994 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 121704
11 March 1994 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1167889
2 February 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 221221
6 January 1994 Deficiency Check · COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1398011
8 May 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 226302
27 February 1993 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 216638
26 February 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 223852
26 February 1993 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 229186
13 February 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 459449
6 January 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 54526
24 December 1992 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1139305
23 December 1992 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 826520
4 December 1992 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 960694
18 November 1992 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1136845
28 August 1992 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 20632
23 June 1992 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1134180
9 December 1991 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1258042
15 November 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 932705
7 October 1991 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 936070
2 July 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 488855
2 July 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1246822
21 March 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 899364
16 January 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 920713
3 October 1990 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 508100
14 August 1990 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1214239
16 January 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1233273
6 September 1989 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1198693
2 September 1989 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 889783
29 September 1988 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1045284
3 November 1987 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1310680
1 October 1987 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1319643
10 July 1987 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 536826
4 July 1987 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1312741
3 March 1987 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1008300
3 November 1986 Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1018254
8 October 1986 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1325868
29 September 1986 Hull Examination · Initial Certification
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1012303
13 January 1986 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 306400
4 September 1984 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 297815
2 June 1984 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 459697

Deficiency record · 151

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 July 2025 Resolved
In a cargo ship, the required fire pump, other than the emergency pump (if any), shall be capable of delivering for firefighting purposes a quantity of water, at the appropriate pressure prescribed…Master reported that both fire pumps are inoperable due to wasted piping in the common manifold between the pumps. Make repairs to the satisfaction of the attending class surveyor prior to movement. 60 SOLAS II/56(a)(ii)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 July 2025
Resolution: Cleared with ABS oversight of repair.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 January 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported approximate 1"x6" gash in starboard ballast tank number 3 above 03 deck due to impact from forklift tynes. Provide risk assessment, class report of damage, and make permanent repairs to satisfaction of RO by next port. 74 SOLAS (20) I/11
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 1 January 2025
Resolved 1 January 2025
Resolution: Puncture to be repaired to the satisfaction of surveyor.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 30 December 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Vessels port lifeboat motor was intermittently failing to start and/or remain operational.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 December 2024
Resolved 30 December 2024
Resolution: It was found by the vessel crew that there was a small amount of water in the bottom of the fuel tank. Water was subsequently removed from the tank and the fuel system reprimed. Satisfactory operational test of the PORT lifeboat was witnessed by attendi
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 December 2024 Resolved
The machinery and associated piping systems and fittings shall be adequate for the service for which they are intended and shall be so installed as to reduce to a minimum any danger to persons onboard. MI discovered f/o leak on EDG high pressure fuel pump near injector #6.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 December 2024
Resolved 30 December 2024
Resolution: The vessel crew replaced the O-ring for EDG fuel injector #6. Operational test of the EDG was witnessed by the attending surveyor and no leaks were observed.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 30 December 2024 Resolved
The machinery and associated piping systems and fittings shall be adequate for the service for which they are intended and shall be so installed as to reduce to a minimum any danger to persons onboard. MI discovered oil soaked lagging on the M/E HFO pump #1.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 6 January 2025
Resolved 30 December 2024
Resolution: Oil soaked lagging to be replaced and subsequently re-inspected to the satisfaction of the attending surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 30 December 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Accumulation of oils found on the deck of fan room 28 creating a personnel hazard.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 6 January 2025
Resolved 30 December 2024
Resolution: Source of oils accumulation found on the deck of fan room 28, to be determined, corrected and area completely cleaned up for subsequent reinspection to the satisfaction of the attending surveyor.
02 - Structural Conditions › N/A - No Subsystem › Spaces in cargo areas
Issued 30 December 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Catwalk between fans 18-20 found significantly wasted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2025
Resolved 30 December 2024
Resolution: Catwalk between fans 18-20 to be cropped and renewed for subsequent re-inspection to the satisfaction of the attending surveyor.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 30 December 2024 Resolved
The means of securing and maintaining weather tightness shall be to the satisfaction of the administration. MI discovered both doors leading to deck 5 lifeboats on P/S sides to not be fully closing and securing. MI discovered interior deck IWO doors to be severely wasted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2025
Resolved 30 December 2024
Resolution: Identified doors leading to deck 5 lifeboats on P/S sides to not be repaired/adjusted accordingly. Interior deck IWO doors to be repaired and re-inspected to the satisfaction of the attending surveyor.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 30 December 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform to the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. MI discovered cracked weld on a deck bracket on a 400L L/O storage tank in engine room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2025
Resolved 30 December 2024
Resolution: Identified crack to be repaired and re-inspected to the satisfaction of the attending surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 July 2023 Resolved
While underway the vessels service generators secured due to lack of fuel which intern secured the propulsion plant.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 July 2023
Resolved 9 September 2024
Resolution: Vessel replaced the valve stem and the fuel system continued to operate as designed.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 9 January 2023 Resolved
The International Load Line Certificate (!966) shall not be delivered to the ship until the officer or surveyor acting under the provisions of article 13 of the present Convention has certified that the marks are correctly and permanently indicated on the ship's sides. The ship was found with load line marks inconsistent with the on board Load Line Certificate.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 23 May 2023
Resolution: Accepted by ABS.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 January 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on-board. Self-closing fire door leading from the galley found with inoperable closing device.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 January 2023
Resolution: Crew replaced the closing mechanism in kind with new.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 3 January 2023 Resolved
Every crew member shall participate in at least one abandon ship drill and one fire drill every month. [...] when a new crew is engaged, these drills shall be held before sailing. USCG to witness drills during next US port of call. 74 SOLAS (14) III/19.3.3.2
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 January 2023
Resolved 9 January 2023
Resolution: Drills witnessed and determined satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 March 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Chart room has electric box missing cover with exposed hazards, radio room has bundle of cable coming from junction box that are tightly bound with zip ties at sharp bends as well as two dead end wires. 74 SOLAS I/11
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 1 April 2022
Resolution: Accepted by TPO.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 March 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Two cargo hold smoke detection panels on bridge are showing error codes for DK3 Aft Zone B and INCIN ROOM. Crew stated errors regularly reappear after clearing. Determine cause for reocurring errors and repair. 74 SOLAS I/11
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 1 April 2022
Resolution: Accepted by TPO.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 15 March 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Corroded area of single ventilation trunk on 06 weatherdeck serving Hospital Head, Repairman HDS, S/S HDS 5DK, and S/S Ladder was probed with inspection hammer and found holed below ventilation closure. 74 SOLAS I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 1 April 2022
Resolution: Accepted by TPO.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 August 2019 Resolved
A survey shall be made every time an accident occurs which affects the safety of the vessel. Fire was reported on the #3 SSDG, and the main space CO2 was discharged. Vessel shall make affected area available for inspection once it has been declared safe for entry by a marine chemist.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 August 2019
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 January 2019 Resolved
Maintenance, testing and inspections shall be carried out in a manner having due regard to ensuring the reliability of fire fighting systems and appliances. Emergency Generator CO2 discharge horn does not have 2 in. clean out pipe.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 January 2019
Resolved 24 January 2019
Resolution: Verified installation of 2 in. clean out pipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 July 2018 Resolved
Prove proper operation of ship service electrical system to the satisfaction of Class and Coast Guard following loss of electrical power casualty.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 July 2018 Resolved
Prove proper operation of steering system prior to departure from San Francisco Bay.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2018
Resolution: Steering system repaired and tested.
Construction/Loadline › Structures › Scuttle
Issued 25 April 2018 Resolved
The bulkhead deck or a deck above it shall be weathertight in the sense that in ordinary sea conditions water will not penetrate in a downward direction. All openings in the exposed weather deck shall have coamings of ample height and strength and shall be provided will efficient means for expeditiously closing them weathertight. Stbd forward most emergency hatch cover has a hole in way of the gasket, compromising weathertight integrity. The emergency fire pump room vent (to fwd port forecastle) cover does not properly secure, leaving the gasket loose and compromising weathertight integrity. 60 SOLAS II/17(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 26 July 2018
Resolution: See ABS report SF3506818 dated 07JUN18.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 April 2018 Resolved
Wiring shall be supported in such a manner as to avoid chafing or other injury. The electrical conduit on the forecastle deck IVO fan room 6 is unsupported as the attachments have corroded away.60 SOLAS II/27(a)(vi)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 26 July 2018
Resolution: See ABS report SF3506818 dated 07JUN18.
Construction/Loadline › Structures › Ventilators
Issued 25 April 2018 Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the space in the event of a fire. Determine proper procedures for use of the cargo deck ventilation damper local shut down / hydraulic bypass valves.60 SOLAS II/47(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 26 July 2018
Resolution: See ABS report SF3506818 dated 07JUN18.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 25 April 2018 Resolved
Structural fire protection shall be kept in good working order. The following discrepancies with SFP were identified and are in need of repair/resolution; Fire Screen Door (FSD) from the Galley to crew scullery not closing properly, FSD from the galley to stores stairwell deteriorated along the lower sill, unsealed wire penetrations on #5 generator space adjacent to 4 deck.74 SOLAS(14)ChII-2 Reg. 14.2.1.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 19 July 2018
Resolution: See ABS report SF3506818 dated 07JUN18.
Construction/Loadline › Structures › Door
Issued 25 April 2018 Resolved
The bulkhead deck or a deck above it shall be weathertight in the sense that in ordinary sea conditions water will not penetrate in a downward direction. All openings in the exposed weather deck shall have coamings of ample height and strength and shall be provided will efficient means for expeditiously closing them weathertight. The following discrepancies in weathertight boundaries were identified: exterior door adjacent to the reefers found with large gaps at the upper and lower middle seam, the aft ramp was found with a 6-8" gap in the gasket on the port side 12' above the deck level, the exterior door from the #5 generator space to the 4 deck found with large gaps at the upper and lower middle seam.60 SOLAS II/17(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 26 July 2018
Resolution: See ABS report SF3506818 dated 07JUN18.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 25 April 2018 Resolved
The condition of the ship and its equipment are to be maintained to ensure it will remain fit to proceed to sea. Vessel found with re-fractured weld repairs on deck 1 in section 14 where the port center longitudinal bulkhead meets the overhead deck and with suspected fractures on the 2 deck where the center pillars meet the overhead. Vessel shall ensure area is inspected by NDT and all fractures found are recorded and repaired. 74SOLAS(14)Ch.I,Reg 11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 26 July 2018
Resolution: See ABS report SF3506818 dated 07JUN18.
Engineering › Steam Boiler (auxiliary/waste heat) › Fuel Oil Burner
Issued 25 April 2018 Resolved
Boiler fuel supply piping shall have spray shields around all bolted flanges. Aux boiler fuel supply lines found without shielding. Provide shields at required flanges. 74SOLAS(14)Ch.I,Reg 11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 26 July 2018
Resolution: See ABS report SF3506818 dated 07JUN18.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (air motor)
Issued 1 May 2007 Resolved
Vsls pilot house control for the MDE is inoperable. Vsl is to have the following engineering manning until the vsl's pilothouse control of the MDE is repaired & all the vsl's automation is tested to the satisfaction of ABS & attending USCG Marine Inspector: 1 Chief Engineer, 1 1st Asst Engineer/2nd Engr, 1 2nd Asst Engineer/3rd Engr, 1 3rd Asst Engr, 3 oilers, and 3 additional engineering mbrs
Action required: 705 - Other - as specified
Resolved 31 July 2008
Resolution: Received ABS report attesting to the repair and testing of the ships automation system.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 13 December 2004 Resolved
Properly seal new stuffing tube for fire detection wiring in way of bulkhead penetration at entrance to emergency fire pump deisel prime mover compartment.
Action required: 705 - Other - as specified
Due 14 January 2005
Resolved 2 February 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 December 2004 Resolved
Install proper wire supports for new wiring installed in forepeak area.
Action required: 705 - Other - as specified
Due 14 January 2005
Resolved 2 February 2006
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 13 December 2004 Resolved
Install new shut down solenoid to the number 1 ships service generator. Vessel shall not operate this generator until satisfactory repairs completed.
Action required: 705 - Other - as specified
Due 14 January 2005
Resolved 2 February 2006
Fire Fighting › Means of Escape › Emergency Lighting
Issued 13 December 2004 Resolved
Repair the lighting at following escape trunks: Dk 2 stbd at F/S 59; Dk 2 stbd at F/S 55; Dk 2 stbd at F/S 61; Dk 2 port at F/S 62; Dk 1 stbd at F/S 73; Dk 1 port at F/S 72; Dk 1 stbd at F/S 69; Dk 1 stbd at F/S 71; and Dk 3 at F/S 38.
Action required: 705 - Other - as specified
Due 14 January 2005
Resolved 2 February 2006
Electrical › Electrical Distribution System (service) › Conductor
Issued 13 December 2004 Resolved
Properly dead end cable located emergency escape trunk at deck 3 aft starboard.
Action required: 705 - Other - as specified
Due 14 January 2005
Resolved 2 February 2006
Electrical › Electrical Distribution System (service) › Conductor
Issued 13 December 2004 Resolved
Properly dead end cable located in emergency escape trunk deck 1, starboard in way of welder switch box.
Action required: 705 - Other - as specified
Due 14 January 2005
Resolved 2 February 2006
Electrical › Electrical Distribution System (emergency) › Conductor
Issued 13 December 2004 Resolved
Remove or properly dead end cable from emergency battery supplying power to abandoned fire detection panel.
Action required: 705 - Other - as specified
Due 14 January 2005
Resolved 2 February 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 13 December 2004 Resolved
Conduct proper fire and boat drill prior to getting underway upon activation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 December 2006
Navigation › Piloting/Steering › Marine Charts
Issued 13 December 2004 Resolved
Update all navigation publications and charts for operating area for the San Francisco Bay area prior to getting underway upon activation. All other pubs must be updated before transiting those areas.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2006
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 13 December 2004 Resolved
Repair or replace the faulty transducer and prove proper operation of the echo depth sounder.
Action required: 705 - Other - as specified
Due 14 January 2005
Resolved 2 February 2006
Lifesaving › Lifeboat Equipment › Food Ration
Issued 13 December 2004 Resolved
Replace 7 failed food rations from the starboard lifeboat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2006
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 13 December 2004 Resolved
Update the fire control plan and submit for approval to reflect the changes made to the fire detection system.
Due 14 January 2005
Resolved 2 February 2006
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 13 December 2004 Resolved
Properly mark the starboard gangway fire control plan location.
Action required: 705 - Other - as specified
Due 14 January 2005
Resolved 2 February 2006
Stability › Watertight Integrity › General
Issued 13 December 2004 Resolved
Properly cap the #1 ballast water tank port sounding tube on the main deck.
Action required: 705 - Other - as specified
Due 14 January 2005
Resolved 2 February 2006
Fire Fighting › Miscellaneous Items › B Class Division Penetrations
Issued 13 December 2004 Resolved
Make starboard midship resistor house vapor tight. Include all stuffing tubes and vent closures.
Action required: 705 - Other - as specified
Due 14 January 2005
Resolved 2 February 2006
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 13 December 2004 Resolved
Remove all door holdbacks on fire screen doors in engineroom and house. Any holdbacks must be capable of remote release.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 13 December 2004 Resolved
Properly mount portable CO2 fire extinguisher #56 in the starboard midship resistor house.
Action required: 705 - Other - as specified
Due 14 January 2005
Resolved 2 February 2006
Fire Fighting › Fire Hoses › Material
Issued 13 December 2004 Resolved
Provide proof that all fire hoses on the vessel meet UL regulation 19 or federal spec ZZ-H-45IE
Action required: 705 - Other - as specified
Due 14 January 2005
Resolved 2 February 2006
Stability › Weathertight Integrity
Issued 27 January 2003 Resolved
Repair as new or replace weathertight door located on deck 8, starboard side at frame 46.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 3 February 2004
Engineering
Issued 4 December 2002 Resolved
Renew hot water pressure temperature relief valve on vessel's domestic hot water heater with a valve that does not exceed 100 psi.
Due 6 January 2003
Resolved 14 January 2003
Resolution: New Hot water tank installed w/proper set points of 100 psi.
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 4 December 2002 Resolved
Repair as new exhaust leak on auxiliary boiler.
Due 6 January 2003
Resolved 14 January 2003
Resolution: Crack in boiler located. Crack was welded sat. No further exhaust leakage.
Operations/Management › Drills/Instruction
Issued 4 December 2002 Resolved
Conduct abandon ship and fire drills prior to getting underway and /or being activated. LEGACY COMPONENT DESC: Abandon Ship
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2003
Resolved 27 January 2003
Resolution: Visited Vessel and witnessed satisfactory Abandon Ship and Fire drill.
Fire Fighting › Fire Hoses › Condition
Issued 4 December 2002 Resolved
Renew ruptured fire hose (ruptured during hydro test).
Due 4 December 2002
Resolved 4 December 2002
Resolution: Fire hose replaced with new hose.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 4 December 2002 Resolved
Renew all food rations which have lost their airtight seal.
Due 4 December 2002
Resolved 4 December 2002
Resolution: Food rations were provided.
Operations/Management › Drills/Instruction
Issued 7 October 2002 Resolved
Conduct Satisfactory Fire and Boat Drill prior to activation. LEGACY COMPONENT DESC: Fire and Abandon Ship Drill
Due 7 October 2002
Resolved 7 October 2002
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 15 November 2001 Resolved
Repair as new the steam safety valve in way of auxiliary boiler. LEGACY COMPONENT DESC: Valve, Relief
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 March 2002
Resolved 7 October 2002
Resolution: Viewed new steam safety valve.
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 15 November 2001 Resolved
Renew low water cut-out lower valve and clean low water bottom sediment blowdown. LEGACY COMPONENT DESC: Blowdown System
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 March 2002
Resolved 17 January 2002
Resolution: Tested low water cut out - sat
Unknown
Issued 2 December 1999 Resolved
REPAIR/REPLACE AND TEST PRESSURE RELIEF VALVE ON THE DECK AIR RECEIVER PRESSURE VESSEL.
Condition: Unknown
Due 15 December 1999
Resolved 9 December 1999
Fire Fighting
Issued 2 December 1999 Resolved
UPDATE FIRE CONTROL PLAN TO INCLUDE ADDITIONAL FIRE STATION(S). POST NEW PLANS AS NEEDED.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Documentation
Issued 2 December 1999 Resolved
PROVIDE THE COGNIZANT OCMI WITH APPROVED PLANS FOR THE AIR COMPRESSOR AND PRESSURE VESSEL LOCATED ON PORT SIDE #4 DECK.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Engineering
Issued 2 December 1999 Resolved
WHILE UNDERWAY, TEST AND RECORD RESULTS OF MDE AUTOMATION ALARMS AND SHUTDOWNS, I.A.W. APPROVED AUTOMATION TEST PROCEDURES. PROVIDE COGNIZANT OCMI A COPY OF THE MDE AUTOMATION TEST RESULTS.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Construction/Loadline
Issued 2 December 1999 Resolved
MAKE EITHER OF THE FWD DEEP FUEL OIL (PORT OR STBD) TANKS AVAILABLE FOR INTERNAL INSPECTION, AND MAKE EITHER OF THE #1 DB FUEL OIL (PORT OR STBD) TANKS AVAILABLE FOR INTERNAL INSPECTION. (2 TANKS TOTAL)
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Lifesaving
Issued 2 December 1999 Resolved
CONDUCT FIRE AND ABANDON SHIP DRILLS PRIOR TO ACTIVATION.
Condition: Unknown
Due 31 December 2000
Resolved 9 December 1999
Engineering
Issued 2 December 1999 Resolved
WHILE UNDERWAY, TEST AND RECORD RESULTS OF STEAM SEPERATOR AND EXHAUST GAS ECONIMIZER STEAM SAFETY RELIEF VALVES. PROVIDE COGNIZANT [name withheld].
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Construction/Loadline
Issued 24 November 1998 Resolved
SUBMIT REPAIR PROPOSAL TO REPAIR 3" FRACTURE ON PORT SIDE AT FRAME 179.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Fire Fighting
Issued 24 November 1998 Resolved
REPAIR LOWER PORTIONS OF VENT CLOSURES FOR EMERGENCY GENERATOR SPACE.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Lifesaving
Issued 24 November 1998 Resolved
CONDUCT FIRE AND ABANDON SHIP DRILLS PRIOR TO NEXT ACTIVATION.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Fire Fighting
Issued 24 November 1998 Resolved
PROVE PROPER OPERATION OF FIXED SMOKE DETECTION SYSTEM FOR CARGO HOLDS PRIOR TO NEXT ACTIVATION.
Condition: Unknown
Due 19 December 1999
Resolved 11 January 1999
Lifesaving
Issued 27 April 1998 Resolved
CONDUCT FULL LOAD WEIGHT TESTS ON BOTH PORT AND STBD LIFEBOATS.
Condition: Unknown
Due 13 May 1998
Resolved 13 May 1998
Engineering
Issued 31 December 1997 Resolved
SUBMIT PLANS FOR APPROVAL TO [name withheld] OF NEWLY CONSTRUCTED DIESEL FUEL TANK FOR GENERATOR ON 04 DECK.
Condition: Unknown
Due 31 December 1997
Resolved 31 December 1997
Construction/Loadline
Issued 19 December 1997 Resolved
REWELD AROUND PIPE PASSAGE IN WAY OF ENTRANCE TO CO2 ROOM.
Condition: Unknown
Due 19 January 1998
Resolved 6 May 1998
Deck/Cargo
Issued 19 December 1997 Resolved
PROVE PROPER OPERATION OF PORT ANCHOR UPON COMPLETION OF REPAIRS.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Electrical
Issued 19 December 1997 Resolved
PROVE PROPER OPERATION AND INSTALLATION OF #5 GENERATOR.
Condition: Unknown
Due 19 January 1998
Resolved 11 May 1998
Accommodation/Occupational Safety
Issued 19 December 1997 Resolved
PROVIDE HAND RELIEVING GEAR FOR MAIN START AIR TANKS' RELIEFS (2).
Condition: Unknown
Due 19 January 1998
Resolved 6 May 1998
Engineering
Issued 19 December 1997 Resolved
REPLACE SEAL AND PROVE PROPER OPERATION OF #4 GENERATOR FUEL PUMP.
Condition: Unknown
Due 19 January 1998
Resolved 6 May 1998
Construction/Loadline
Issued 19 December 1997 Resolved
COMPLETE REPAIRS TO THREE PORT MOST COLLISION BLKD (FRAME #237) STIFFENERS IN UPPERMOST AREA OF FORE-PEAK TANK IN ACCORDANCE WITH SUBMITTED REPAIR PROPOSAL.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Construction/Loadline
Issued 19 December 1997 Resolved
COMPLETE REPAIRS TO BUCKLED DECK AND HULL IN WAY OF STEVEDORES HEAD ON PORTSIDE BETWEEN FRAMES #26 AND #27 OVER AFT PEAK COFFERDAM IN ACCORDANCE WITH SUBMITTED REPAIR PROPOSAL.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Construction/Loadline
Issued 19 December 1997 Resolved
COMPLETE REPAIRS TO WASTED AREAS IN #1 PORT UPPER WING BALLAST TANK IN ACCORDANCE WITH SUBMITTED REPAIR PROPOSAL.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Construction/Loadline
Issued 19 December 1997 Resolved
COMPLETE REPAIRS TO CRACKED PORTMOST AFT BLKD STIFFENER, CRACK IN BOTTOM OFVERTICAL STIFFENER IN FWD MOST CENTER BAY, HOLED RUDDER VOID VENT PIPING, AND KNIFE-EDGED OVERHEAD BRACKETS, BEAMS, AND STIFFENERS IN PORT AFT PEAK TANK IN ACCORDANCE WITH SUBMITTED REPAIR PROPOSAL.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Construction/Loadline
Issued 19 December 1997 Resolved
COMPLETE REPAIRS TO BROKEN WELDS BTWN VERTICAL STIFFENERS AND OVERHEAD HORIZONTAL BAFFLE BEAMS IN STBD SIDE BAYS, KNIFE-EDGED LIGHTENING HOLES ANDOVERHEAD BRACKETS, AND RENEW MISSING BOTTOM 6 FEET OF SOUNDING TUBE IN STBDAFT PEAK BALLAST TANK IN ACCORDANCE WITH SUBMITTED REPAIR PROPOSAL.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Fire Fighting
Issued 19 December 1997 Resolved
PERFORM HYDROTEST ON SCBA BOTTLES IN CONTROL ROOM FOUND OUT OF DATE.
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Construction/Loadline
Issued 19 December 1997 Resolved
RENEW VENT ON ESCAPE HATCH COAMING ON STBD SIDE BY FIRE STATION #17.
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Fire Fighting
Issued 19 December 1997 Resolved
ADJUST FIRE SCREEN DOORS IN STAIRTOWER ON DECK #7 TO CLOSE TIGHT WITH DOOR CLOSURE DEVICE.
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Fire Fighting
Issued 19 December 1997 Resolved
PROVIDE THE FOLLOWING FOR THE LP CO2 SYSTEM: (1) TOP-UP LIQUID CO2 TANK. _x001C_ (2) CALIBRATE ELECTRONIC LIQUID LEVEL GAUGE. (3) ADJUST DISCHARGE CYLINDERSFOR CARGO SPACES IAW SYSTEM PLAN. (4) VERIFY LOW LEVEL ALARM. (5) PROVE OPERATION OF PNEUMATIC SIRENS FOR DECK 1,2,2B AFT CARGO SPACE.
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Lifesaving
Issued 19 December 1997 Resolved
PROVIDE PLACARDS FOR DOORS ON PAINT LOCKER AND EMERGENCY GENERATOR ROOM "SPACE PROTECTED BY CO2 - KEEP DOORS LOCKED OPEN WHILE OCCUPIED".
Condition: Unknown
Due 19 January 1998
Resolved 6 May 1998
Lifesaving
Issued 19 December 1997 Resolved
CONDUCT FIRE AND ABANDON SHIP DRILLS PRIOR TO ACTIVATION.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Lifesaving
Issued 19 December 1997 Resolved
REINSTALL EPIRB
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Accommodation/Occupational Safety
Issued 19 December 1997 Resolved
CLEAN GREASE FROM STOVE TRAPS AND HOOD SCREENS IN GALLEY.
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Engineering
Issued 19 December 1997 Resolved
RE-CONNECT ALL LINES FOR STEAM ECONOMIZER CIRC. PUMPS TO STEAM SEPARATOR.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Fire Fighting
Issued 19 December 1997 Resolved
PROVE PROPER OPERATION OF CO2 SIRENS FOR DECKS 1,2, & 2B AFT CARGO SPACES.
Condition: Unknown
Due 31 December 1997
Resolved 31 December 1997
Lifesaving
Issued 19 December 1997 Resolved
CONDUCT FULL LOAD WEIGHT TEST ON PORT AND STARBOARD LIFEBOATS.
Condition: Unknown
Due 28 April 1998
Resolved 28 April 1998
Engineering
Issued 19 December 1997 Resolved
PROVIDE HANGARS FOR #5 GENERATOR J/W LINE IN BOILER ROOM.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Construction/Loadline
Issued 19 December 1997 Resolved
COMPLETE REPAIRS TO PORT AND STBD AFT PEAK BALLAST TANKS IAW SUBMITTED REPAIR PROPOSAL.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Construction/Loadline
Issued 19 December 1997 Resolved
COMPLETE REPAIRS TO WASTED OVERHEAD HORIZONTAL BAFFLE SUPPORT BEAM IN #4 PORT UPPER WING BALLAST TANK AT FRAME #76, THREE BAYS AFT OF THE AFT MOST ACCESS ON THE BOTTOM LEVEL OF THE TANK IN ACCORDANCE WITH SUBMITTED REPAIR PROPOSAL.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Construction/Loadline
Issued 19 December 1997 Resolved
PERMANENTLY PLUG HOLE IN FORWARD SUPERSTRUCTURE OF BOILER ROOM.
Condition: Unknown
Due 19 January 1998
Resolved 6 May 1998
Fire Fighting
Issued 4 September 1997 Resolved
Provide approved plans for the modifications to the low pressure CO2 pipingsystem manifold for the tank level indicator.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Construction/Loadline
Issued 8 August 1997 Resolved
PROVIDE REPAIR PROPOSALS TO REPAIR/RENEW AREAS WASTED OVER 25% IN PIPE TUNNEL AND ENGINE ROOM VENTILATION SUPPLY SPACE AS SHOWN IN GAUGING REPORTS.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
PROVIDE REPAIR PROPOSAL FOR BROKEN WELDS BETWEEN VERTICAL STIFFENERS AND OVERHEAD HORIZONTAL BAFFLE BEAMS IN STBD SIDE BAYS AND KNIFE-EDGED LIGHTENING HOLES AND OVERHEAD BRACKETS IN STBD AFT PEAK BALLAST TANK. ALSORENEW MISSING BOTTOM 6 FEET OF SOUNDING TUBE.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
PROVIDE REPAIR PROPOSAL FOR AREAS IDENTIFIED WITH WASTAGE OVER 25% (AS PER GAUGING REPORT) IN BOTH AFT PEAK BALLAST TANKS.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
PROVIDE REPAIR PROPOSAL FOR WASTED OVERHEAD HORIZONTAL BAFFLE SUPPORT BEAM IN #4 PORT UPPER WING BALLAST TANK AT FRAME #76, THREE BAYS AFT OF THE AFT MOST ACCESS ON THE BOTTOM LEVEL OF THE TANK.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
PROVIDE REPAIR PROPOSAL FOR THREE PORTMOST COLLISION BULKHEAD (FRAME #237) STIFFENERS IN UPPERMOST AREA OF FORE-PEAK TANK. BOTTOM 2 INCHES OF EACH_x001C_ ARE WASTED AWAY.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Accommodation/Occupational Safety
Issued 8 August 1997 Resolved
REPAIR LOOSE DOGS ON WATER-TIGHT DOORS THROUGHOUT CARGO AREA.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 8 August 1997 Resolved
PROVIDE APPROVED PLANS/LETTER FOR HIGH TEMPERATURE COOLING INSTALLATION IN ENGINE ROOM.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
PROVE PROPER OPERATION OF CHAIN LOCKER EDUCTOR USING VESSEL'S FIREMAIN.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
PROVIDE REPAIR PROPOSAL FOR BUCKLED DECK AND HULL AS WELL AS RIPPED WELD FOR DECK BRACKET IN STEVEDORE'S HEAD ON PORT SIDE, BETWEEN FRAMES #26 AND #27 OVER AFT PEAK COFFERDAM.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
PROVIDE REPAIR PROPOSAL FOR WASTED AREAS IN #1 PORT UPPER WING BALLAST TANK BETWEEN FRAMES #327 AND #236.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
PROVIDE REPAIR PROPOSAL FOR CRACKED PORTMOST AFT BULKHEAD STIFFENER, CRACK IN BOTTOM OF VERTICAL STIFFENER IN FORWARD MOST CENTER BAY, HOLED RUDDER VOID VENT PIPING, AND KNIFE-EDGED OVERHEAD BRACKETS, BEAMS, AND STIFFENERS IN PORT AFT PEAK TANK.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
PROVIDE FINALIZED HULL MARKING PLAN AND FORMAL REQUEST FOR ENTRANCE INTO UNDERWATER IN LIEU OF DRYDOCK PROGRAM.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Accommodation/Occupational Safety
Issued 8 August 1997 Resolved
PROVE PROPER OPERATION AND WATER-TIGHT INTEGRITY OF WATER-TIGHT DOOR FOR ENGINE ROOM VENTILATION SUPPLY SPACE.
Condition: Unknown
Due 15 February 2002
Resolved 15 February 2002
Electrical
Issued 8 August 1997 Resolved
PROVE PROPER INSTALLATION AND TEST NEW SHORE POWER BREAKER ACCORDING TO APPROVED PLANS.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 8 August 1997 Resolved
PROVIDE APPROVED PLANS/LETTER FOR NEW SEACHEST ANODE INSTALLATION OR PLANS FOR APPROVAL.
Condition: Unknown
Due 7 September 1997
Resolved 8 August 1997
Fire Fighting
Issued 27 March 1997 Resolved
MAKE LP CO2 ELECTRONIC GAUGING SYSTEM OPERATIONAL OR SUBMIT PLANS & MODIFY AS APPROVED. CHECK & RECORD THE TANK LEVEL, AS READ BY FROST LINE, EACH WEK AND DOCUMENT IN OFFICIAL LOG.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Fire Fighting
Issued 5 February 1996 Resolved
MAKE LP CO2 ELECTRONIC GAGING SYSTEM OPERATIONAL OR SUBMIT PLANS & MODIFY AS APPROVED. CHECK & RECORD THE TANK LEVEL, AS READ BY FROST LINE, EACH WEEK AND DOCUMENT IN OFFICIAL LOGBOOK.
Condition: Unknown
Due 5 February 1996
Resolved 5 February 1996
Lifesaving
Issued 5 February 1996 Resolved
REPLACE FWD LIFERAFT WITH A SOLAS TYPE (160.151 APPROVAL SERIES) RAFT.
Condition: Unknown
Due 5 February 1996
Resolved 5 February 1996
Lifesaving
Issued 15 February 1995 Resolved
PROVIDE THE FOLLOWING ITEMS FOR THE LIFEBOATS: 4 RESCUE QUOITS W/ LINES, 2RADAR RELECTORS, 10 THERMAL PROTECTIVE AIDS, ALL AS POER REGULATION 41, CHAPTER III, SOLAS
Condition: Unknown
Due 16 April 1995
Resolved 6 March 1995
Fire Fighting
Issued 11 March 1994 Resolved
REPLACE 1 CO2 HOSE ON #1 DEHUMIDIFICATION UNIT, 2 ON #2 DEHUMIDIFICATION UNIT AND ADJUST WEATHER COVERS OVER CO2 BOTTLES ON UNITS !,2 AND 4 SO THAT THE SHARP EDGES ARE WELL CLEAR OF THE CO2 HOSES. CORRECT PRIOR TO DEPARTINGCHARLESTON, SOUTH CAROLINA.
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Documentation
Issued 6 January 1994 Resolved
UPDATE VESSELS OPERATION MANUAL TO INCLUDE ALL SAFETY ITEMS AND PROCEDURES FOR CARGO HOLD ENTRY AND MAINTENANCE DURING DEHUMIDIFICATION AS DEFINED IN MARAD LETTERS DATED 04NOV93 AND 02DEC93. AND USCG LETTERS 28SEP93 AND 02DEC93.
Condition: Unknown
Due 6 January 1994
Resolved 6 January 1994
Lifesaving
Issued 6 January 1994 Resolved
PROVIDE AND INSTALL SIGNS FOR ALL CARGO HOLD DOORS AND THROUGHOUT THE CARGOHOLDS TO COMPLY WITH MARAD LETTER DATED 04NOV93.
Condition: Unknown
Due 6 January 1994
Resolved 6 January 1994
Documentation
Issued 6 January 1994 Resolved
PROVIDE DOCUMINTATION THAT THE INCINERATOR MEETS THE REQUIREMENTS IN USCG LETTER 16710/MITH 1840 DATED 21DEC93.
Condition: Unknown
Due 6 January 1994
Resolved 6 January 1994
Electrical
Issued 6 January 1994 Resolved
INSTALL AND PROVE SATISFACTORY OPERATION OF THE HIGH TEMPERATURE DEVICES REQUIRED FOR THE INCINERATOR AS DEFINED IN 46CFR63.25-9(b).
Condition: Unknown
Due 6 January 1994
Resolved 6 January 1994
Engineering
Issued 6 January 1994 Resolved
THE PORTABLE FUELING STATION LOCATED ON DECK IS NOT TO BE USED UNTIL SUCH TIME AS IT IS APPROVED AND PROPERLY TESTED. REQUIRED FIREFIGHTING EQUIPMENTAS DEFINED IN 46CFR98.30-37(e) IS PROVIDED.
Condition: Unknown
Due 6 January 1994
Resolved 6 January 1994
Unknown
Issued 6 January 1994 Resolved
PRIOR TO DEPARTING THE AREA OF HAMPTON ROADS, AND AFTER SEA TRIALS ON 06 AND 07JAN94 ALL, 27 WORK LIST ITEMS ARE TO BE COMPLETED.
Condition: Unknown
Due 15 January 1994
Resolved 20 January 1994
Accommodation/Occupational Safety
Issued 6 January 1994 Resolved
PROVE SATISFACTORY OPERATION OF THE NEWLY INSTALLED DEHUMIDIFICATION SYSTEM.
Condition: Unknown
Due 6 January 1994
Resolved 6 January 1994
Electrical
Issued 6 January 1994 Resolved
A QUALIFIED ENGINEER IS TO STAND WATCH AT THE TEMPORARY EMERGENCY GENERATORDURING SEA TRIALS. VESSEL IS TO RETURN TO HAMPTON ROADS TO MAKE PERMANENT REPAIRS TO THE VESSELS EMERGENCY GENERATOR AFTER SEA TRIALS.
Condition: Unknown
Due 7 January 1994
Resolved 20 January 1994
Electrical
Issued 6 January 1994 Resolved
NORMAL LIGHTING CIRCUIT BREAKERS FOR CARGO HOLD LIGHTING ARE TO BE LABELED TO PREVENT BEING ENERGIZED DURING DEHUMIDIFICATION OF THE CARGO HOLDS.
Condition: Unknown
Due 6 January 1994
Resolved 6 January 1994
Accommodation/Occupational Safety
Issued 18 November 1992 Resolved
UPDATE ALL EXPIRED HOSPITAL ROOM MEDICATION PRIOR TO PLACING VESSEL ON_x001C_ OPERATIONAL STATUS.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Lifesaving
Issued 18 November 1992 Resolved
CONDUCT FIRE AND BOAT DRILLS IN THE PRESENCE OF THE COAST GUARD INSPECTOR_x001C_ PRIOR TO PLACING VESSEL ON OPERATIONAL STATUS.
Condition: Unknown
Due 18 November 1992
Resolved 18 November 1992
Documentation
Issued 18 November 1992 Resolved
RENEW FCC CERTIFICATE PRIOR TO PLACING VESSEL ON OPERATIONAL STATUS.
Condition: Unknown
Due 18 November 1992
Resolved 18 November 1992
Engineering
Issued 18 November 1992 Resolved
OVERSPEED MAIN PROPULSION ENGINE AT NEXT UNDERWAY OPERATION, RECORD RESULTSAND SUBMIT STATEMENT TO [name withheld].
Condition: Unknown
Due 18 November 1992
Resolved 18 November 1992
Documentation
Issued 18 November 1992 Resolved
UPDATE ALL EXPIRED CHARTS AND PUBLICATIONS PRIOR TO PLACING VESSEL ON _x001C_ OPERATIONAL STATUS.
Condition: Unknown
Due 18 November 1992
Resolved 18 November 1992
Engineering
Issued 18 November 1992 Resolved
RENEW THE AUX. BOILER STEAM GAUGE.
Condition: Unknown
Due 18 November 1992
Resolved 18 November 1992
Electrical
Issued 18 November 1992 Resolved
EFFECT PERMANENT REPAIRS AND MAKE OPERATIONAL THE EMERGENCY GENERATOR.
Condition: Unknown
Due 18 November 1992
Resolved 18 November 1992
Lifesaving
Issued 7 October 1991 Resolved
MAKE PERMANENT REPAIRS TO THE CO2 DETECTOR SYSTEM. UTILIZE HAND OPERATED DETECTORS AS NECESSARY._x001C_
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Engineering
Issued 7 October 1991 Resolved
MAKE PROPERLY OPERABLE THE ALARM CIRCUIT BOARD FOR THE #3 S/S GENERATOR PRIME MOVER L.O. INLET TEMPERATURE HIGH._x001C_ _x001C_
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Engineering
Issued 7 October 1991 Resolved
SET AND LOG THE RELIEF AND SET PRESSURES FOR THE EXHAUST GAS ECONOMIZER SAFETY VALVES AT 142PSIG OR LOWER. NOTIFY THE COGNIZANT OCMI AT THE NEXT U.S. PORT._x001C_
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Engineering
Issued 14 August 1990 Resolved
OPEN THE MAIN STARTING AIR RECEIVER #HRV86-005 AND THE EMERGENCY AIR RECEIVER #HRV86-006 FOR INTERNAL EXAM.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Fire Fighting
Issued 14 August 1990 Resolved
PROPERLY LABLE FIRE DAMPERS TO SHOW LOCATION AND THE OPEN AND CLOSE POSITION IN THE GALLEY AND THE ACCOMMODATION SPACES.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Construction/Loadline
Issued 14 August 1990 Resolved
MAKE VESSEL AVAILABLE FOR INTERNAL STRUCTURAL EXAM BY COGNIZANT OCMI.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Engineering
Issued 14 August 1990 Resolved
SET THE STEAM SEPERATOR RELIEF VALVE 99 PSI OR BELOW AND THE EXHAUST GAS ECONOMIZER 142 PSI OR BELOW AT SEA AND LOG IN THE OFFICAL LOG.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Engineering
Issued 14 August 1990 Resolved
REPAIR TWO BROKEN SIGHT GLASSES ON THE OILY WATER SEPERATOR FILTER STAGING UNITS.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Fire Fighting
Issued 14 August 1990 Resolved
CLEARLY MARK ENGINE ROOM, GENERATOR ROOM AND PURIFIER ROOM EMERGENCY ESCAPEROUTE.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Deck/Cargo
Issued 14 August 1990 Resolved
PROVE PROPER OPERATION OF THE THREE INCINERATOR UNITS USING THE APPROVED INSTRUCTION MANUAL.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Fire Fighting
Issued 2 September 1989 Resolved
PROVIDE AN INTERNATIONAL SHORE CONNECTION NOT LATER THAN 02OCT89 OR PRIOR TO SAILING FROM NEXT US PORT(SAVANNAH), WHICHEVER COMES FIRST.
Condition: Unknown
Due 2 September 1989
Resolved 2 September 1989
Lifesaving
Issued 2 September 1989 Resolved
END-FOR-END BOTH SETS OF LIFEBOAT FALLS.
Condition: Unknown
Due 2 September 1989
Resolved 2 September 1989
Fire Fighting
Issued 2 September 1989 Resolved
PROVE THAT THE FIXED CO2 SYSTEM SENDS CO2 TO THE PAINT LOCKER FOR THE APPROVED AMOUNT OF TIEM(TWO MINUTES). ITEM TO BE COMPLETED TO THE SATIS- FACTION OF THE COGNIZANT OCMI NOT LATER THAN 02OCT89 OR PRIOR TO SAILING FROM NEXT US PORT(SAVANNAH), WHICHEVER COMES FIRST.
Condition: Unknown
Due 2 September 1989
Resolved 2 September 1989
Engineering
Issued 2 September 1989 Resolved
TEST SAFETY RELIEF VALVES ON THE STEAM SEPARATOR AND THE EXHAUST GAS ECONO-MIZER AND LOG RESULTS. PROVIDE [name withheld] WITH A COPY OF THE LOG ENTRY ANDTHE COGNIZANT OCMI IS TO BE NOTIFIED TO SEAL SAFETIES. THIS ITEM TO BE COMPLETED NO LATER THAN 02OCT89 OR PRIOR TO DEPARTURE NEXT US PORT(SAV.,GA)
Condition: Unknown
Due 2 September 1989
Resolved 2 September 1989
Engineering
Issued 2 September 1989 Resolved
TEST THE MAIN ENGINE OVERSPEED TRIP AND LOW LUBE OIL TRIP UNDERWAY AND LOG RESULTS. PROVIDE [name withheld] WITH A COPY OF THE LOG ENTRY. ITEM TO BE COM-PLETED NO LATER THAN 02OCT89 OR PRIOR TO DEPARTURE FROM NEXT US PORT(SAVANNAH), WHICHEVER COMES FIRST.
Condition: Unknown
Due 2 September 1989
Resolved 2 September 1989
Electrical
Issued 2 September 1989 Resolved
DEMONSTRATE PROPER OPERATION OF REVERSE POWER RELAY ON THE #5 AUX GENER- ATOR. ITEM TO BE COMPLETED TO SATISFACTION OF COGNIZANT OCMI AND NOT LATERTHAN 02OCT89 OR PRIOR TO DEPARTURE NEXT US PORT(SAVANNAH), WHICHEVER COMES FIRST.
Condition: Unknown
Due 2 September 1989
Resolved 2 September 1989
Engineering
Issued 2 September 1989 Resolved
DEMONSTRATE PROPER OPERATION OF THE OILY WATRE SEPARATOR. ITEM TO BE COM- PLETED TO SATISFACTION OF THE COGNIZANT OCMI NOT LATER THAN 02OCT89 OR PRIOR TO DEPARTURE NEXT US PORT(SAVANNAH), WHICHEVER COMES FIRST.
Condition: Unknown
Due 2 September 1989
Resolved 2 September 1989
Engineering
Issued 2 September 1989 Resolved
DEMONSTRATE PROPER OPERATION OF THE WRONG DIRECTION ALARM AND ENGINE ORDER TELEGRAPH BELL LOCATED AT ENGINEROOM CONSOLE. ITEM TO BE COMPLETE TO THE SATISFACTION OF COGNIZANT OCMI NOT LATER THAN 02OCT89 OR PRIOR TO DEPARTURENEXT US PORT(SAVANNAH), WHICHEVER COMES FIRST.
Condition: Unknown
Due 2 September 1989
Resolved 2 September 1989
Fire Fighting
Issued 2 September 1989 Resolved
STENCIL ALL FIRE EXTINGUISHERS AND STATIONS IAW THE CURRENT APPROVED FIRE CONTROL PLAN. ITEM TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI NOT LATER THAN 02OCT89 OR PRIOR TO SAILING FROM NEXT US PORT(SAVANNAH)WHICHEVER COMES FIRST.
Condition: Unknown
Due 2 September 1989
Resolved 2 September 1989
Fire Fighting
Issued 2 September 1989 Resolved
PROVE THE SMOKE DETECTION SYSTEM OPERATIONAL. ITEM TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI NOT LATER THAN 02OCT89 OR PRIOR TO SAILING FROM THE NEXT US PORT(SAVANNAH), WHICHEVER COMES FIRST.
Condition: Unknown
Due 2 September 1989
Resolved 2 September 1989
Unknown
Issued 29 September 1986 Resolved
IN ACCORDANCE WITH BARBER STEAMSHIP LINES (SHIP MANAGEMENT) INC LETTER OF 29 SEPTEMBER 1986, RESOLVE ALL TECHNICAL PLAN REVIEW COOMENTS ON PRESENT & FUTURE SUBMITTALS. RESOLUTION TO INCLUDE ALL ADMIN AND RESULTING SHIPBOARD MODIFICATIONS AND TO BE SATISFACTORY TO THE COGNIZANT OCMI.
Condition: Unknown
Due 29 September 1986
Resolved 29 September 1986

Casualty record · 7

6 March 2003Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 1759922
19 December 2013Routine · role: Involved in a Marine Casualty · activity 4772373
15 March 2023Routine · role: Involved in a Marine Casualty · activity 7653347
1 May 2023Routine · role: Involved in a Marine Casualty · activity 7685728
14 July 2023Routine · role: Involved in a Marine Casualty · activity 7742499
2 February 2025Routine · role: Involved in a Marine Casualty · activity 8074194
25 May 2025Routine · role: Involved in a Marine Casualty · activity 8144653
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.