MAURY USCG vessel records Sign in
← All vessels

SKANDERBORG

SKANDERBORG is a 1979 freight ship. The Coast Guard has recorded 84 inspections since 1984, most recently in June 2014, along with 32 deficiencies and 19 operational controls.

Records from 1984 to 2014. Most recent: operational control imposed, 2 June 2014.

Built
1979
Last inspected
2 June 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7725154 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228582
Flag
PANAMA
—
Maury page id
psix-228582

Inspections, by type

…with no type recorded58
Years with a record 29 calendar years (1984–2014)
The 84 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it10470 - Dead Weight, Ton
4441 - Convention (Subpart B), Net Ton
4441 - Regulatory (Subpart C or D), Net Ton
14805 - Convention (Subpart B), Gross Ton
14805 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 84

2 June 2014 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4876977
2 June 2014 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4877356
2 June 2014 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4877616
26 May 2014 ISPS I Exam · PI Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4867096
25 May 2014 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4867951
23 June 2012 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4265965
22 June 2012 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4352548
25 December 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4213784
7 July 2011 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4072462
1 July 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4061320
21 January 2011 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3930500
20 January 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3928743
6 November 2010 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3886061
28 October 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3879522
27 February 2010 PII Safety Exam · Ballast Water Examination · ISPS II Exam · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3687120
23 February 2010 PI Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3685039
23 February 2010 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3685363
23 February 2010 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3685541
14 February 2010 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3679805
9 December 2009 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3646794
18 July 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3537109
2 May 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3465656
2 May 2009 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3465675
26 February 2009 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3424178
4 December 2008 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3374476
23 September 2008 MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3330320
21 July 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3270825
20 May 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3211504
20 May 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3318595
11 March 2008 MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3160341
4 March 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3158331
14 July 2007 Random ISPS/MTSA/PSC
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2994608
25 April 2007 Type not recorded
No type recorded · Station Mayport · USCG Southeast District (CGD-SE) · Activity 2915971
24 April 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2914447
23 May 2006 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2656850
22 February 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2590234
3 December 2005 ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2545477
26 November 2005 Type not recorded
No type recorded · Vessel Traffic Service Houston-Galveston · USCG Heartland District (CGD-H) · Activity 2562539
13 April 2005 NPV Safety Exam · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2333608
24 August 2004 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2175427
7 June 2004 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2091567
26 March 2004 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2040338
24 March 2004 Re-Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2030194
23 July 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1855172
25 March 2002 In-Service Inspection · Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1597355
9 January 2002 Administrative Inspection · In-Service Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1477052
15 November 2001 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1486595
15 November 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 434757
25 November 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 423128
22 September 1998 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 420611
9 October 1997 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 408653
8 October 1996 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 396137
16 September 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 395373
2 August 1996 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 393752
27 September 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 383107
27 May 1995 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 378789
20 March 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 376313
6 January 1995 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 373905
23 August 1994 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 643953
19 August 1994 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 369651
12 August 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 369568
29 March 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 532772
20 August 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 360301
25 May 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 479386
15 March 1993 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 357034
22 December 1992 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 355164
11 July 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 351809
4 September 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 462570
13 January 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 440043
8 January 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 341194
20 July 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 485943
18 December 1989 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 334347
8 October 1989 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 456715
1 May 1989 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 439493
9 November 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 326738
10 June 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 450785
22 March 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 468143
21 October 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 319144
27 May 1987 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 534609
12 December 1986 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 313389
23 June 1986 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 527617
11 December 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 305864
16 November 1984 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 483708
14 November 1984 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 298984

Deficiency record · 32

Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 2 June 2014 Resolved
COFR has been revoked since 12MAR14.
Action required: 705 - Other - as specified
Due 2 June 2014
Resolved 2 June 2014
Resolution: Vsl has received a valid COFR.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 6 November 2010 Resolved
The A class door between the main cargo deck and the forward machinery space is wasted preventing fire protection to both spaces. Rectify deficiencies within 30 days to Class.
Action required: 705 - Other - as specified
Due 7 December 2010
Resolved 21 January 2011
Resolution: verified via onsite check and class report
Engineering › Steering Gear System › Follow-up Assembly
Issued 6 November 2010 Resolved
On top of the emergency steering gear assembly, there was an excessive amount of oil.
Action required: 705 - Other - as specified
Due 7 December 2010
Resolved 21 January 2011
Resolution: verified via onsite check and class report.
Engineering › Diesel Engine (auxiliary) › Piping (air intake)
Issued 6 November 2010 Resolved
There is a soft patch located on the #3 diesel generator on the cooling water line. Rectify deficiencies within 30 days to Class.
Action required: 705 - Other - as specified
Due 7 December 2010
Resolved 21 January 2011
Resolution: verified via onsite check and class report.
Lifesaving › Inflatable Liferafts › Capacity
Issued 6 November 2010 Resolved
On the vessels liferafts the number of person are not listed.
Action required: 705 - Other - as specified
Due 7 December 2010
Resolved 21 January 2011
Resolution: verified via onsite check and class report.
Construction/Loadline › Markings › Load Line Mark
Issued 6 November 2010 Resolved
The load line on the ship is not painted due to the paint wearing away.
Action required: 705 - Other - as specified
Due 7 December 2010
Resolved 21 January 2011
Resolution: verified via onsite check and class report.
Documentation › Certificates/Documents › IOPP Certificate
Issued 6 November 2010 Resolved
The International Oil Pollution Prevention Certificate was missing the Oily Water Seperator throughput. RINA the classification society for the vessel was present to correct the deficiency.
Action required: 705 - Other - as specified
Resolved 7 November 2010
Resolution: Corrected on the spot.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 6 November 2010 Resolved
In the vessels galley the fire door is fitted with the means to be self closing type. The door does not operate correctly and will not self close causing a potential fire hazard.
Action required: 705 - Other - as specified
Due 7 December 2010
Resolved 21 January 2011
Resolution: Verified via onsite check and class report.
Engineering › Steering Gear System › Pump
Issued 1 March 2010 Resolved
SecBalt received notification from Sector Hamptons Roads that vessel suffered a loss of steerage as a result of a defect with the #1 steering pump. SecBalt issued a COTP 09-10 for a tug escort into Sector Baltimore zone. PSC inspectors will address issue when vessel is at berth w/ the assistance of a RINA class surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2010
Resolution: Received class report attesting to proper operation of steering gear.
Navigation › Piloting/Steering › Notices to Navigation
Issued 1 March 2010 Resolved
Vessel does not have a current IAMSAR publication on-board, Vessel shall place an up up-to-date copy of Vol. III IAMSAR manual on board prior to next US port after sailing foriegn (74 SOLAS 09 CONS, CH V Reg. 21 & Reg. 33.1).
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 May 2010
Resolution: Vessel submitted proper documentation stating that a current IAMSAR publication is on board.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 1 March 2010 Resolved
Vessel is currently missing 08 food ration for starboard life boat and 02 food ration for port side lifeboat , vessel to place 10 total food ration in lifesaving appliance prior to departure (60 SOLAS CH III, Reg11 (a) (xii)).
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2010
Resolution: Received receipt for delivery of 12 food rations.
Engineering › Steering Gear System › Pump
Issued 23 February 2010 Resolved
While in transit, the ship's steering gear system indicated a failure of the system pumps resulting in a lost of steering for approximately 30 seconds. At this time, it appears that the steering gear is working properly, but it is unclear why failure occurred. Solas 04 Con. Chp II-1 Reg 29.2.1- To the satisfaction of Class Society
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 February 2010
Resolution: Received Class Surveyor report stating deficiency was rectified.
Electrical › Electric Generation Source (emergency) › Generator
Issued 9 December 2009 Resolved
Terminations and joints in all conductors shall be made as to retain the original electrical, mechanical, flame-retarding and fire-resisting properties. temporary connections were found on all main generator of electrical cables, causing potential short circuit and fire hazard. SOLAS 74 (2004 CONS) Ch. II-I 45.5.6 70 (A)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 February 2010
Resolution: Sector Houston received a class report attesting to the proper conditions for the electrical connections on the main generator cables.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 9 December 2009 Resolved
Main inlets and outlets of all ventilation systems shall be capable of being closed from outside the space in the event of a fire. An electrical cable was found running through the emergency generator room vent to cleaning filter pumps for crane winches. Instillation creates fire spread hazard. SOLAS 60 Ch 2 Reg 47(a) 70 (a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 February 2010
Resolution: Sector Houston received a class report attesting to the rectifying of electrical cable running through the emergency generator room.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 2 May 2009 Resolved
0611 - Vessels STBD Lifeboat is short 06 and the Port lifeboat is short 09 of the required 40 each. Vessel shall have the required rations onboard prior to departure from port. SOLAS '60 CH III/REG 11.a,xii
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2009
Resolution: Received receipt from vessel''s Master indicating that the missing 15 rations are now onboard the vessel.
Construction/Loadline › Markings › Load Line Mark
Issued 23 September 2008 Resolved
Vessels Loadline on the starboard side are damaged to the point that they are no longer permanently attached to the vessel. Repair and verify they are correct, to classification society
Action required: 705 - Other - as specified
Due 24 October 2008
Resolved 4 December 2008
Resolution: Recieved class report stating repairs were made to the sat of class
Engineering › Diesel Engine (propulsion-direct drive) › Valve, Check (air start)
Issued 20 May 2008 Resolved
The vessel had a loss of propulsion. The vessel is required to submit documentation from the certificate issuing authority attesting to the proper operation of the vessel's propulsion system.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2008
Resolution: The vessel submitted documentation attesting to the proper operation of the propulsion system.
Communications › Radio Communications › VHF Radiotelephone
Issued 4 March 2008 Resolved
VHF Loud Speaker remains silent.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 March 2008
Resolution: 07MAR2008-Received tech report attesting to the proper repairs and operation of the vessels VHF radio loud speaker system.
Engineering › Freshwater System (jacketwater cooling)
Issued 24 March 2004 Resolved
MAIN SALT WATER COOLING PIPE LOCATED STBD LOWER ENGINE ROOM HAS A DOUBLER. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 24 April 2004
Resolved 7 June 2004
Resolution: Item cleared by class
Pollution Prevention/Response › Prevention Equipment
Issued 24 March 2004 Resolved
INLET PIPING FOR MSD HAS NUMEROUS WASTED SECTIONS. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Action required: 705 - Other - as specified
Due 24 April 2004
Resolved 7 June 2004
Resolution: Item cleared by class
Accommodation/Occupational Safety › Occupational Safety
Issued 24 March 2004 Resolved
NON-CONDUCTIVE MATTING MISSING IN EMERGENCY GENERATOR ROOM.
Action required: 705 - Other - as specified
Due 24 April 2004
Resolved 7 June 2004
Resolution: Item cleared by class
Construction/Loadline › Markings
Issued 24 March 2004 Resolved
PLIMSOL MARK BOTH PORT AND STBD SIDE DOES NOT REFLECT LOAD LINE CERTIFICATE. LEGACY COMPONENT DESC: Load Line Mark
Action required: 705 - Other - as specified
Due 24 April 2004
Resolved 7 June 2004
Resolution: Item cleared by class
Fire Fighting
Issued 24 March 2004 Resolved
CLASS SOCIETY SURVEYOR TO ATTEST TO LOCATION, SYMBOLOGY AND APPROVAL OF THE FIRE CONTROL PLAN.
Action required: 705 - Other - as specified
Due 24 April 2004
Resolved 7 June 2004
Resolution: Item cleared by class
Navigation › Piloting/Steering
Issued 9 January 2002 Resolved
Inoperative gyro compass IAW 33 CFR 164.35. Repair and provide tech. report prior to departure. LEGACY COMPONENT DESC: Gyro Compass
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 9 January 2002
Resolved 16 January 2002
Resolution: Allowed vessel to sail after receiving tech repair report.
Navigation
Issued 22 September 1998 Resolved
INOPERABLE ECHO DEPTH SOUNDER._x001C_ 33 CFR 164.35(h)
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Navigation
Issued 2 August 1996 Resolved
SOLAS II-I/26 & II/13.2: EXCESSIVE OIL ON DECK OF STEERING GEAR ROOM. NO NON SLIP SURFACE. CLEAN AND REMOVE OIL FROM DECK. PROVIDE NON SLIP SURFACE AS PER SOLAS REQUIREMENTS, ie ELEVATED WOOD DECKING, NON SKID. CORRECT NOT LATER THAN 02SEP96.
Condition: Unknown
Due 24 September 1996
Resolved 24 September 1996
Accommodation/Occupational Safety
Issued 2 August 1996 Resolved
ILO 147: TOP DOOR HINGE FOR BATTERY ROOM BROKEN. CORRECT NOT LATER THAN 02SEP96.
Condition: Unknown
Due 24 September 1996
Resolved 24 September 1996
Lifesaving
Issued 2 August 1996 Resolved
SOLAS III/27.2.2.2: 4 LIFE JACKETS LIGHTS AT STERN LIFE JACKET STORAGE AREA EXPIRED. CORRECT NOT LATER THAN 02SEP96.
Condition: Unknown
Due 24 September 1996
Resolved 24 September 1996
Documentation
Issued 19 August 1994 Resolved
The completed pages of the oil record book were not signed by the master.
Condition: Unknown
Due 22 August 1994
Resolved 22 August 1994
Deck/Cargo
Issued 19 August 1994 Resolved
Three pallets of class 3 hazardous materials were not secured in hold._x001C_
Condition: Unknown
Due 22 August 1994
Resolved 22 August 1994
Documentation
Issued 21 October 1987 Resolved
33CFR156.150(B) THE VESSEL CONDUCTED OIL TRANSFER WITHOUT A PROPERLY COMPLETED (INITIALED) DECLARATION OF INSPECTION.
Condition: Unknown
Due 21 October 1987
Resolved 21 October 1987
Documentation
Issued 21 October 1987 Resolved
33CFR155.720 THE OIL TRANSFER PROCEDURES FOR BUNKER OPERATIONS WERE IN- COMPLETE.
Condition: Unknown
Due 22 March 1988
Resolved 21 October 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.