Records from 1988 to 2002. Most recent: inspection, 9 February 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 7
9 February 2002
In-Service Inspection · Administrative Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1485279
1 February 2002
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1483354
31 October 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 139420
17 October 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 283248
25 March 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 952607
15 April 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 479502
14 September 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 325667
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 1 February 2002
Resolved
FUEL PUMP NO.2 CYLINDER LEAKING ON GENERATOR NO.1 - PROVIDE CLASS REPORT ATTESTING TO REPAIR TO USCG. LEGACY COMPONENT DESC: Pump, High Pressure (fuel injection)
Condition: Unknown
Due 8 February 2002
Resolved 9 February 2002
Resolution: Received class report attesting to proper repair.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 1 February 2002
Resolved
PROVIDE CLASS REPORT ADDRESSING FIXED CO2 SYSTEM OPERATION PROTECTING SCAVENGING AIR MDE. NO SERVIVING REPORTS ARE AVAILABLE. LEGACY COMPONENT DESC: Operating Controls
Condition: Unknown
Due 8 February 2002
Resolved 9 February 2002
Resolution: Received class report attesting to proper repair and servicing.
Fire Fighting › Emergency Fire Pumps
Issued 1 February 2002
Resolved
EMERGENCY FIRE PUMP DIESEL ENGINE EXHAUST LAGGING IS WASTED - HEALTH HAZARD- ASBESTOS FIBERS VISABLE IN ENVIROMENT OF SPACE. CLASS TO ATTEST TO PROPER REPAIR. LEGACY COMPONENT DESC: Arrangement
Condition: Unknown
Due 8 February 2002
Resolved 9 February 2002
Resolution: Received class report attesting to proper repair.
Fire Fighting › Emergency Fire Pumps
Issued 1 February 2002
Resolved
PROVIDE MACHINERY GUARD ON EMERGENCY FIRE PUMP DIESEL ENGINE FLYWHEEL. PROVIDE CLASS REPORT ATTESTING TO PROPER REPAIR. LEGACY COMPONENT DESC: Arrangement
Condition: Unknown
Due 8 February 2002
Resolved 9 February 2002
Resolution: Received class report attesting to proper repair.
Electrical › Electrical Distribution System (service)
Issued 1 February 2002
Resolved
PROVIDE NON-CONDUCTIVE MATTING AT ALL ELECTRICAL PANELS IN ENGINE ROOM TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Unknown
Due 8 February 2002
Resolved 9 February 2002
Resolution: Received class report attesting to proper repair.
Operations/Management › Drills/Instruction
Issued 1 February 2002
Resolved
UPDATE FIRE CONTROL PLAN TO REFLECT PROPER CREW LIST. LEGACY COMPONENT DESC: Fire
Due 8 February 2002
Resolved 9 February 2002
Resolution: Received class report attesting to proper repair.
Electrical › Electrical Distribution System (service)
Issued 1 February 2002
Resolved
WINDLASS ELECTRICAL CONTROL RM. ELECTRICAL CONTROL PANELS ARE MISSING. PROVIDE PROPER HAZARD FREE COVERS. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Unknown
Due 8 February 2002
Resolved 9 February 2002
Resolution: Received class report attesting to proper repair.
Lifesaving › Lifebuoys
Issued 1 February 2002
Resolved
REPLACE AND OR PEPAIR LIFE BOUYS ONBOARD.
Condition: Unknown
Due 8 February 2002
Resolved 9 February 2002
Resolution: Received class report attesting to proper repair.
Stability › Watertight Integrity
Issued 1 February 2002
Resolved
CHECK ALL WATERTIGHT DOORS, THE GASKETS ARE WASTED AND DETERIORATED. LEGACY COMPONENT DESC: DOORS
Condition: Unknown
Due 8 February 2002
Resolved 9 February 2002
Resolution: Received class report attesting to proper repair.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 1 February 2002
No resolution recorded
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Fire Fighting › Nozzles
Issued 1 February 2002
Resolved
REMOVE ALL "SUICIDE" TYPE FIRE FIGHTING NOZZELS FROM HOSE LOCATIONS THROUGHOUT SHIP. PROVIDE CLASS REPORT ADDRESSING SAME, ATTESTING TO COMPLIANCE. LEGACY COMPONENT DESC: Type
Due 8 February 2002
Resolved 9 February 2002
Resolution: Received class report attesting to proper repair.
Lifesaving
Issued 17 October 2000
Resolved
REMOVE EXCESSIVE OIL IN BILGES
Condition: Unknown
Due 19 October 2000
Resolved 23 October 2000