MAURY USCG vessel records
← All vessels

PALMELA

Built
1999
Last inspected
28 July 2026
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 July 2026
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9207388
Flag
PANAMA
Maury page id
psix-2286

Documentation record

Tonnage as PSIX records it55926 - Convention (Subpart B), Gross Ton
16778 - Convention (Subpart B), Net Ton
34401 - Displacement, Ton
20581 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

28 July 2026 VRP Review
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8448450
12 May 2026 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8371762
8 May 2026 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8369196
4 May 2026 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8356483
15 March 2025 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8090367
21 November 2024 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8037989
13 September 2024 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7999893
1 November 2023 PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7815020
24 March 2022 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7415731
17 March 2022 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7413803
17 August 2021 Ballast Water Examination · PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7282779
7 March 2020 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6917231
2 November 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6843120
15 March 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6642651
14 March 2019 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6640798
30 December 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6063904
2 January 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5787053

Deficiency record · 6

10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 13 September 2024 Resolved
To assist in casualty investigation, cargo ships, when engaged on an international voyages, shall be fitted with a VDR which may be simplified voyage data recorder (S-VDR). PSCO identified the retro reflective tape on S-VDR is no longer visable and labled according to manufacture requirements. 74SOLAS(20) V/20.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2024
Resolved 21 November 2024
Resolution: RECEIVED CLASS REPORT ATTESTING TO ORANGE RETRO-REFLECTOR TAPE WITH THE MANUFACTURER LABEL ON VDR.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 September 2024 Resolved
A lifejacket complies with the requirements of paragraph 2.2.1 or 2.2.2 of the code shall... Be fitted with retro reflective material where it will assist in the detection and in the accordance with the recommendations of the organization. PSCO found 06 life jackets that had faded retro-reflective tape that was no longer effective. 74SOLAS(20) III/7.2.1 LSA 1.2.2.7
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 September 2024
Resolved 13 September 2024
Resolution: Ships crew Replaced SOLAS reflective tape
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 24 March 2022 Resolved
74SOLAS(2020ed) CH II-2 REG 10-3.2.4 Fire Extingushers shall be situated ready for use and in such a way that their servicability is not impaired by other external forces. Foam Portable Extinguisher in engine room was found with collapsed hose preventing porper operation of the extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 March 2022
Resolved 24 March 2022
Resolution: Agent was able to facilitate the purchase and installation of a new extinguisher for the 45lb extinguisher with a worn hose.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 17 August 2021 Resolved
10113 - Safety of Navigation - Ships fitted with AIS shall maintain AIS in operation at all times except where international agreements, rules or standards provide for the protection of navigational information. Vessel AIS was not in operation during transit into U.S. waters and while in port. - 74 SOLAS 20 con. V/19.2.4.5.7. - 10c
Action required: 10 - Deficiency Rectified
Resolved 17 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 15 March 2019 Resolved
11101 - All life-saving appliances and arrangements shall comply with applicable requirements of the LSA Code. Every totally enclosed lifeboat shall be provided with a rigid watertight enclosure. Port and starboard side grab rails on the starboard lifeboat were repaired improperly compromising the watertight integrity of the lifeboat. 74SOLAS (14) III/34; LSA Code 4.6.2; 50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 2 November 2019
Resolution: Visually inspected with no issues and received class report stating repairs were completed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 March 2019 Resolved
09209 - All electrical apparatus shall be so installed as not to cause injury when handled or touched in a normal manner. Observed improperly installed electrical supply power cables on port lifeboat davit connection and on light fixtures in the vicinity of starboard side embarkation and on starboard side in way of accommodation access area. 74SOLAS (04) II-1/45.1.3; 50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 2 November 2019
Resolution: Vessel submitted Class report attesting to the repairs. Visually inspected by USCG PSC team.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.