MAURY USCG vessel records Sign in
← All vessels

POLAR COSTA RICA

POLAR COSTA RICA is a 1979 freight ship. The Coast Guard has recorded 14 inspections since 1986, most recently in October 2003, along with 28 deficiencies and 2 operational controls.

Records from 1986 to 2003. Most recent: inspection, 21 October 2003.

Built
1979
Last inspected
21 October 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7728998 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228622
Flag
BAHAMAS, THE
—
Maury page id
psix-228622

Inspections, by type

…with no type recorded10
Years with a record 9 calendar years (1986–2003)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it10768 - Dead Weight, Ton
17443 - Displacement, Ton
3510 - Convention (Subpart B), Net Ton
10371 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 14

21 October 2003 Ballast Water Examination · Deficiency Check · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1933139
11 December 2002 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1717444
2 December 2002 Re-Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1712916
10 September 2002 Ballast Water Examination · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1673751
21 June 2002 Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1634254
6 September 1995 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 382169
16 March 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 349410
19 November 1990 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 340442
7 November 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 333524
19 July 1988 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 324471
15 June 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 317109
15 June 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 506900
18 February 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 482088
28 April 1986 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 308472

Deficiency record · 28

Documentation › Certificates/Documents
Issued 21 October 2003 Resolved
Provide report from class society attesting to rectification of the 04 Port state control deficiencies issued in Baltimore, MD on 02DEC02. LEGACY COMPONENT DESC: Class Document
Action required: 705 - Other - as specified
Due 23 October 2003
Resolved 23 October 2003
Resolution: Received satisfactory class report.
Navigation › Piloting/Steering
Issued 2 December 2002 Resolved
GYROCOMPASS SHALL BE REPAIRED PRIOR TO DEPARTING COTP BALMS. LEGACY COMPONENT DESC: Gyro Compass
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 6 December 2002
Resolution: RCVD TECH REPORT (UNITED RADIO SERVICE,INC.) GYROCOMPASS IS REPAIRED.
Engineering › Diesel Engine (auxiliary)
Issued 2 December 2002 Resolved
COOLING WATER PIPE ON #4 GENERATOR IS WASTED, REPAIR TO SATISFACTION OF CLASS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 21 October 2003
Resolution: Verified repairs during annual inspection.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 2 December 2002 Resolved
PIPE FOR PISTON COOLER IS WASTED, MAKE REPAIRS TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Piston
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 21 October 2003
Resolution: Verified repairs during annual exam.
Electrical › Electric Generation Source (emergency)
Issued 2 December 2002 Resolved
HERTZ AND VOLT GUAGES ARE OUT OF CALIBRATION. REPAIR/ REPLACE TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Panelboard
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 December 2002
Resolved 11 December 2002
Resolution: METERS HAVE BEEN FOUND TO BE IN CALIBRATION.
Deck/Cargo › Holds/Tanks
Issued 2 December 2002 Resolved
FRACTURED HATCH COAMING BRACKETS ON #3 AND #4 CARGO HOLDS, MAKE REPAIRS TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Coaming
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 21 October 2003
Resolution: Verified repairs during annual exam.
Construction/Loadline › Structures
Issued 2 December 2002 Resolved
GASKET ON BOSN STORES HATCH IS WASTED. LEGACY COMPONENT DESC: Scuttle
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 December 2002
Resolved 11 December 2002
Resolution: GASKET ON HATCH HAS BEEN RENEWED.
Deck/Cargo › Mooring/Anchoring
Issued 2 December 2002 Resolved
PORT AND STBD CHAIN WASH PIPES ARE WASTED, REPAIR TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Anchor Chain (general)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 21 October 2003
Resolution: Verified repairs during annual exam.
Deck/Cargo › Mooring/Anchoring
Issued 2 December 2002 Resolved
BOTH HAWSER PIPE COAMBINGS ARE TOARN AND CHAIN IS WEARING MAIN DECK, REPAIR TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Mooring Line/Hawser
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 December 2002
Resolved 11 December 2002
Resolution: WASTED MATERIAL HAS BEEN CROPPED AND RENEWED.
Deck/Cargo › Holds/Tanks
Issued 2 December 2002 Resolved
CARGO HOLD #1 STBD SIDE COVER IS BENT AND NO LONGER WATERTIGHT. MAKE REPAIRS TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Hatch Cover
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 December 2002
Resolved 11 December 2002
Resolution: COVER HAS BEEN REPAIRED AND A NEW GASKET INSTALLED.
Construction/Loadline › Structures
Issued 2 December 2002 Resolved
CLASS SOCIETY TO INSPECT AND MAKE RECOMENDATIONS FOR REPAIRS TO STBD SIDE BULWARK WHICH WAS TORN AND BENT IN HEAVY WEATHER. LEGACY COMPONENT DESC: Plowshare Breakwater
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 December 2002
Resolved 11 December 2002
Resolution: BULWARK HAS BEEN REPAIRED.
Construction/Loadline › Structures
Issued 2 December 2002 Resolved
CLASS SOCIETY TO INSPECT FRACTURES IWO MID SHIPS HOUSE, JUST BELOW THE LIFERAFTS. FRACTURES ARE ON BOTH SIDES OF SHIP. LEGACY COMPONENT DESC: Superstructure
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 December 2002
Resolved 11 December 2002
Resolution: FRACTURES HAVE BEEN DRILL STOPPED AND REWELDED.
Lifesaving › Embarkation Appliances/Stations
Issued 11 September 2002 Resolved
REPLACE WASTED EMBARKATION LADDER IWO PORT LIFEBOAT STATION PRIOR TO DEPARTURE LEGACY COMPONENT DESC: LADDER
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 11 September 2002
Resolved 12 September 2002
Resolution: LADDER RENEWED.
Construction/Loadline › Structures
Issued 11 September 2002 Resolved
REPAIR PLATFORM AT BASE OF PROVISIONS CRANE. PLATFORM WASTED AND HOLED LEGACY COMPONENT DESC: CRANE PLATFORM
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 October 2002
Resolved 4 December 2002
Resolution: REPAIRS HAVE BEEN MADE TO SATISFACTION OF CLASS.
Pollution Prevention/Response › Prevention Equipment
Issued 11 September 2002 Resolved
BASE OF OWS WASTED AND REPAIRD W/ TEMP MATERIAL. MAKE PERMANENT REPAIRS. CLAS TO APPROVE REPAIRS AND TEST AND PROVIDE TEST REPORT TO COGNISENT CAPT. OF THE PORT PRIOR TO OPERATION OF OWS IN US OR US TERRITORIAL WATERS LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 September 2002
Resolved 12 September 2002
Resolution: SECTION OF OWS OBSERVED WAS REMNANT FROM OLD 100PPM SYSTEM AND WAS REMOVED FROM VESSEL.
Engineering
Issued 11 September 2002 Resolved
EXCESSIVE OIL IN BILGES. MUST BE REMOVED PRIOR TO DEPARTURE. ONCE OIL IS REMOVED CONTACT COTP BALTIMORE FOR APPROVAL
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 11 September 2002
Resolved 12 September 2002
Deck/Cargo › Cargo Refrigeration
Issued 11 September 2002 Resolved
PIPE FOR COOLING SYSTEM FOR CARGO HOLD IS WASTED AND FOUND TO HAVE TEMP SOFT PATCH AND CEMENT PATCH. MAKE PERMANENT REPAIRS TO SATISFACTION OF CLASS LEGACY COMPONENT DESC: PIPING
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 October 2002
Resolved 4 December 2002
Resolution: REPAIRS HAVE BEEN MADE TO SATISFACTION OF CLASS.
Electrical › Electrical Distribution System (service)
Issued 11 September 2002 Resolved
MISSING MAT FOR NON-CONDUCTIVE FLOORING IN FRONT OF EMERGENCY GENERATOR ELECTRIDCAL PANNEL. MUST PROVIDE PRIOR TO DEPARTURE LEGACY COMPONENT DESC: NON-CONDUCTIVE FLOORING
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 September 2002
Resolved 12 September 2002
Engineering › Freshwater System (jacketwater cooling)
Issued 10 September 2002 Resolved
PIPE FOR SALT WATER COOLIONG FOR MAIN SERVICE GENERATORS HOLED AND SPRAYING WATER. PERMANENT REPAIRS TO BE MADE TO SATISFACTION OF CLASS PRIOR TO DEPARTURE LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 11 September 2002
Resolved 12 September 2002
Resolution: REPAIRS MADE TO SATISFACTION OF CLASS.
Lifesaving › Lifeboat Equipment
Issued 21 June 2002 Resolved
PROVIDE MISSING FOOD RATIONS FOR BOTH PORT AND STBD LIFEBOATS, 9 PORT, 9 STBD FOR TOTAL OF 18 FOOD RATIONS AT 10,000 KG'S EACH LEGACY COMPONENT DESC: Food Ration
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2002
Resolved 22 June 2002
Resolution: RECEIPT FOR FOOD RATIONS RECEIVED FROM AGENT.
Lifesaving › Launching Appliances
Issued 21 June 2002 Resolved
CLASS SOCIETY SURVEYOR TO ATTEST TO THE PROPER OPERATION OF THE LIMIT SWITCH SYSTEM ON BOTH PORT AND STBD LIFEBOAT DAVIT SYSTEMS LEGACY COMPONENT DESC: Davit
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 July 2002
Resolved 21 June 2002
Resolution: CLASS ATTESTED TO THE PROPER REPAIR AND OPERATION OF BOTH PORT AND STBD LIMIT SWITCH SYSTEMS.
Fire Fighting › Fire Main
Issued 21 June 2002 Resolved
REPLACE FIREMAIN PIPING STBD SIDE. NUMEROUS TEMP. REPAIRS/ DOUBLERS. SYSTEM TESTED SAT. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 July 2002
Resolved 12 September 2002
Resolution: CLASS REPORT ATTESTING TO THE PERMANENT REPAIRS AND TESTING.
Engineering › Sea-water System (primary cooling)
Issued 21 June 2002 Resolved
CLASS SOCIETYT SURVEYOR TO ATTEST TO TEMP REPAIR ON SALT WATER OVBD VALVE LOCATED IN LOWER ENGINE ROOM PORTSIDE. MAKE RECOMMENDATIONS FOR PERMINENT REPAIR LEGACY COMPONENT DESC: Valve
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 October 2002
Resolved 4 December 2002
Resolution: SALT WATER PIPE HAS BEEN RENEWED.
Pollution Prevention/Response › Prevention Equipment
Issued 21 June 2002 Resolved
SEWAGE TANK HOLED AND WASTED, SEWAGE PUMP MISSING GUARD. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 June 2002
Resolved 12 September 2002
Resolution: SEWAGE TANK REPAIRED TO SAT. OF CLASS.
Documentation
Issued 6 September 1995 Resolved
PROVIDE ON BOARD 3RD MATES LICENSE. (MISSING)
Condition: Unknown
Due 12 September 1995
Resolved 12 September 1995
Fire Fighting
Issued 6 September 1995 Resolved
PROVIDE DUAL PURPOSE FIRE NOZZLES FOR STATIONS #1 AND #3 IN ENGINE ROOM. (MISSING)
Condition: Unknown
Due 12 September 1995
Resolved 12 September 1995
Navigation
Issued 19 July 1988 Resolved
A VIO OF 33 CFR 164.30 IN THAT THE VSL DID NOT HAVE O/B U.S. CHART 12304 ORIT'S FOREIGN EQIUVALENT WHICH WAS REQUIRED FOR THE VSL'S ROUTE FROM CAPE HENLOPEN TO ARNOLD'S POINT.
Condition: Unknown
Due 19 July 1988
Resolved 19 July 1988
Documentation
Issued 28 April 1986 Resolved
VSL WAS MISSING OIL TRANSFER PROCEDURES, WHICH IS REQUIRED BY 33 CFR 155.720. THE CAPACITY FOR FUEL WAS GREATER THEN 2000 BBLS.
Condition: Unknown
Due 28 April 1986
Resolved 28 April 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.