MAURY USCG vessel records Sign in
← All vessels

HOUSTON

HOUSTON is a 1979 freight ship. The Coast Guard has recorded 45 inspections since 1984, most recently in April 2004, along with 12 deficiencies and 5 operational controls.

Records from 1984 to 2004. Most recent: operational control imposed, 19 April 2004.

Built
1979
Last inspected
19 April 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7729203 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228626
Flag
PANAMA
—
Maury page id
psix-228626

Inspections, by type

…with no type recorded38
Years with a record 18 calendar years (1984–2004)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it31555 - Dead Weight, Ton
43075 - Displacement, Ton
11562 - Convention (Subpart B), Net Ton
23239 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 45

19 April 2004 Deficiency Check · Re-Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2047877
7 April 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2038992
22 December 2002 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1476908
27 April 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1610231
22 December 2001 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1476916
21 December 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1475804
20 December 2001 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1474503
11 January 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 4419
11 January 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 285656
9 August 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 154389
9 August 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 281028
15 February 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 274764
9 October 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 408684
1 August 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 393783
20 March 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 389119
29 June 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 380270
28 January 1995 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 374571
19 September 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 370587
4 May 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 442669
24 August 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 73217
16 August 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 360217
22 March 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 517649
9 July 1992 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 351800
25 November 1991 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 347319
15 November 1991 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1243943
5 November 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 346937
5 June 1991 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 344200
25 September 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 439023
15 May 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 337116
26 April 1990 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 336783
2 January 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 445074
11 March 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 328999
4 November 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 326636
15 October 1988 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 498380
13 October 1988 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 496416
12 January 1988 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 320710
3 September 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 501661
8 January 1987 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 313695
10 December 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 532429
28 August 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 444467
10 August 1986 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 443964
21 November 1985 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 305611
11 July 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 504904
8 November 1984 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 298904
21 June 1984 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 296740

Deficiency record · 12

Engineering › Gasoline Engine (propulsion)
Issued 19 April 2004 Resolved
The main engine has a major cooling water leak on the #3 cylinder that is draining to a 55-gallon drum on the mid level deck, which is full and overflowing. LEGACY COMPONENT DESC: #3 Cylinder
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2004
Resolved 21 April 2004
Resolution: Received satisfactory class report clearing deficiency.
Engineering › Gasoline Engine (propulsion)
Issued 19 April 2004 Resolved
The main engine is covered in oil because of numerous minor leaks, numerous drain lines not draining and overflowing, and maintenance. Several electrical boxes/connections and gauges are covered with oil and unreadable. Repair leaks and clean engine and the surrounding area of all oil.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2004
Resolved 21 April 2004
Resolution: Received satisfactory class report clearing deficiency.
Engineering › Gasoline Engine (propulsion)
Issued 19 April 2004 Resolved
The engine room and steering compartment are extremely dirty. All of the fuel and oil containments under machinery are filled with oil. The decks and ladder ways are slippery. Remove all fuel and oil from containments and wipe down machinery, decks and ladder ways. LEGACY COMPONENT DESC: Engine room and steering compartment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2004
Resolved 21 April 2004
Resolution: Received satisfactory class report clearing deficiency.
Engineering › Steering Gear System
Issued 19 April 2004 Resolved
The steering gear has numerous hydraulic leaks at the control rod to tilt plate seals and the installed catch buckets are full and overflowing. LEGACY COMPONENT DESC: Control rod
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2004
Resolved 21 April 2004
Resolution: Received satisfactory class report clearing deficiency.
Engineering › Gasoline Engine (propulsion)
Issued 19 April 2004 Resolved
The pipe lagging located on the starboard side mid level of the main engine is completely soaked with oil. LEGACY COMPONENT DESC: Pipe lagging
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 21 April 2004
Resolution: Received satisfactory class report clearing deficiency.
Engineering › Steam Boiler (propulsion)
Issued 19 April 2004 Resolved
The boiler is inoperable because of a crack in the casing at the water sight glass. LEGACY COMPONENT DESC: Inoperable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 21 April 2004
Resolution: Received satisfactory class report clearing deficiency.
Pollution Prevention/Response › Prevention Equipment
Issued 7 April 2004 Resolved
Required containment around Port and Sarboard fill pipes and vents for lubes, cylinder oil, and sludge was missing. As required by 33 CFR 155.320 (a)(2). Correct prior to next bunkering in U.S. port or within 30 days. LEGACY COMPONENT DESC: Fixed Containment
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Due 7 May 2004
Resolved 19 April 2004
Resolution: Verified containment installed during re-exam.
Accommodation/Occupational Safety › Occupational Safety
Issued 7 April 2004 Resolved
Catwalk for #4 Cargo hatch was found to be broken, thusly making it a personnel safety hazard. As required by ILO 147. Repair (renew) within 30 days. LEGACY COMPONENT DESC: Catwalk
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2004
Resolved 19 April 2004
Resolution: Verified repairs to catwalk completed during re-exam.
Navigation › Collision/Grounding Avoidance
Issued 20 December 2001 Resolved
Inoperable radar. Vessel required to make repairs to satisfaction of the certificate issuing authority. LEGACY COMPONENT DESC: Radar
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 December 2001
Resolved 27 April 2002
Resolution: cleared. radar functions.
Engineering
Issued 11 January 2001 Resolved
MAIN ENGINE CONTROL SYSTEM MALFUNCTIONED. AFTER STOP BELL, ENGINE WOULD NOTRESTART BECAUSE AN ELECTRICAL RELAY FAILED CLOSED, CAUSING A CONTINUOUS ELECTRICAL SIGNAL TO THE SOLENOID VALVE. THE CIRCUIT IS NORMALLY OPEN UNLESS "ENGINE STOP" HAS BEEN SELECTED.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 12 January 2001
Resolved 21 December 2001
Resolution: Cleared by class.
Engineering
Issued 11 January 2001 Resolved
REPAIR START AIR SYSTEM TO THE SATISFACTION OF CLASS SOCIETY SURVEYOR
Condition: Unknown
Due 12 January 2001
Resolved 5 July 2001
Documentation
Issued 12 January 1988 Resolved
DANGEROUS CARGO MANIFEST HAD IMPROPER SHIPPING NAME AND UN# NUMBER.
Condition: Unknown
Due 12 January 1988
Resolved 12 January 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.