← All vessels
ALEXIA M
ALEXIA M is a 1979 freight ship. The Coast Guard has recorded 10 inspections since 1987, most recently in October 2000, along with 56 deficiencies and 2 operational controls.
Records from 1987 to 2000. Most recent: operational control imposed, 27 October 2000.
- Built
- 1979
- Last inspected
- 27 October 2000
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 56 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7729746 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
P3QV8
228637
Flag
TURKEY
—
Maury page id
psix-228637
Inspections, by type
…with no type recorded10
Years with a record
5 calendar years (1987–2000)
The 10 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it25400 - Dead Weight, Ton
9275 - Regulatory (Subpart C or D), Net Ton
16241 - Regulatory (Subpart C or D), Gross Ton
9275 - Regulatory (Subpart C or D), Net Ton
16241 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 10
27 October 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 283443
30 August 2000
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 281441
27 August 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 281453
20 July 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 418292
30 April 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 415297
12 January 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 708758
11 January 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 374204
6 January 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 373841
25 July 1990
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 338617
28 August 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 318337
Deficiency record · 56
Construction/Loadline
Issued 27 October 2000
Resolved
Remove standing oil in engine room bilges to sludge tank if capacity permits. Otherwise must discharge to an approved shoreside facility. SOLAS 74/CH I/II.
Documentation
Issued 27 October 2000
Resolved
Provide copy of valid Safety Management Certificate. SOLAS 74/CH IX
Navigation
Issued 27 October 2000
Resolved
Provide technician report attesting to proper operation of ARPA. SOLAS 74/V12
Engineering
Issued 30 August 2000
Resolved
Transfer pump piping for cylinder oil has temp repair, affect permanent repairs to the satisfaction of Class and attending CG Marine Inspector.
Engineering
Issued 30 August 2000
Resolved
Main engine cooler pipe holed in way of outlet valve. Affect permanent repairs to the satisfaction of Class and attending CG Marine Inspector.
Engineering
Issued 30 August 2000
Resolved
Emergency crossover line for generator cooling holed, affect permanent repairs to the satisfaction of Class and attending CG Marine Inspector.
Fire Fighting
Issued 30 August 2000
Resolved
Missing fire nozzles and various fire valves broke off at the stem. Prove proper operation of all firestations inside the superstrucure to the satisfaction of class and attending CG Marine Inspector.
Lifesaving
Issued 30 August 2000
Resolved
Davit arm trackway wasted in way of roller assembly, located stbd side, fwdchannel. Vessel's Class to recommend repairs.
Lifesaving
Issued 30 August 2000
Resolved
Vessel's class to attest to the condition of lifeboat lifting gear through hull bolts and aft mount pin located on the port lifeboat.
Navigation
Issued 30 August 2000
Resolved
Prove proper operation of the port side clear port.
Engineering
Issued 27 August 2000
Resolved
MACHINERY GUARDS ON PUMP SHAFTS NOT IN PLACE.
Electrical
Issued 27 August 2000
Resolved
EMERGENCY SHUTDOWN VALVE NEED TO BE REPLACED.
Fire Fighting
Issued 27 August 2000
Resolved
FIREMAIN WASTED BETWEEN #4 & #5 HOLD
Engineering
Issued 27 August 2000
Resolved
SHELL PLATING IN FUEL VALVE CONTAINMENT WASTED AWAY.
Deck/Cargo
Issued 27 August 2000
Resolved
HYDROLIC HOSES FOR CARGO HATCH COVERS #5,#2,#6,, HOSES LEAKING AND DETERIORATED.
Deck/Cargo
Issued 27 August 2000
Resolved
NUMEROUS DOGS MISING OR BROKEN ON CARGO HATCH COVERS.
Deck/Cargo
Issued 27 August 2000
Resolved
DECK CRANE SUPPORT AT BASE CRACKED AND WASTED.
Deck/Cargo
Issued 27 August 2000
Resolved
SUPPORTING STRUCTURE AT CORNNERS OF CARGO HOLDS #6 NEED REPLACING OR REPAIRED.
Construction/Loadline
Issued 27 August 2000
Resolved
WASTED SEWAGE OVERBOARD SPOOL PIECE LOCATED ON PORT SIDE ENGINE ROOM
Fire Fighting
Issued 27 August 2000
Resolved
MACHINERY GUARD ON EMERGENCY FIRE PUMP SHAFT NOT IN PLACE.
Engineering
Issued 27 August 2000
Resolved
FUEL OIL TRIP VALVE FOR MIXING TANK IN ENGINE ROOM NEEDS REPAIRING OR REPLACE.
Accommodation/Occupational Safety
Issued 27 August 2000
Resolved
DECK IN GALLY UNDER TILE FLOORNEAR DUMB WAITER WASTED AWAY.
Engineering
Issued 30 April 1998
Resolved
FUEL OIL CONTAINMENT STARBOARD BUNKER STATION._x001C_ MARPOL 73/78 ANNEX 1
Construction/Loadline
Issued 30 April 1998
Resolved
WASTED HULL PLATING STBD SIDE ENGINE ROOM LOWER LEVEL_x001C_ SOLAS 60 REG I/11
Lifesaving
Issued 30 April 1998
Resolved
PORT LIFEBOAT DAVIT LIMIT SWITCH INOP/INEFFECTIVE_x001C_ SOLAS 60 REG III/36K
Navigation
Issued 30 April 1998
Resolved
PERMANENTLY INSTALL RUDDER ANGLE INDICATOR WIRE IN STEERING ROOM_x001C_ SOLAS 60 REG II/27
Lifesaving
Issued 30 April 1998
Resolved
PORT LIFEBOAT LOWER RUDDER SUPPORT WASTED._x001C_ SOLAS 74 AMND REG III/19.2
Navigation
Issued 30 April 1998
Resolved
EMERGENCY STEERING INSTRUCTIONS NOT POSTED IN STEERING ROOM/ NOT LEGIBLE ONTHE BRIDGE_x001C_ 33 CFR 164.35K
Navigation
Issued 30 April 1998
Resolved
PROVIDE KNOBS ON STEERING GEAR CONTROLS IN STEERING ROOM_x001C_ SOLAS 60 REG II/27A
Deck/Cargo
Issued 30 April 1998
Resolved
HYDRAULIC LEAK STBD SIDE HATCH #5_x001C_ SOLAS 60 REG I/11
Engineering
Issued 30 April 1998
Resolved
GUARDS FOR INGESTION PUMP _x001C_ ILO 147
Fire Fighting
Issued 30 April 1998
Resolved
#2 FIRE PUMP EXCESSIVE WATER LEAK._x001C_ SOLAS 60 REG II/56E
Engineering
Issued 30 April 1998
Resolved
MAKE PERMANENT REPAIRS TO SALT WATER PIPING/ AIR ASPIRATOR LINE._x001C_ SOLAS 60 REG I/11
Accommodation/Occupational Safety
Issued 30 April 1998
Resolved
EXCESSIVE OIL IN OWS ROOM_x001C_ SOLAS 60 REG II/34
Accommodation/Occupational Safety
Issued 30 April 1998
Resolved
EXCESSIVE OIL ON DECK ON GENERATOR FLAT_x001C_ SOLAS 60 REG II/34
Accommodation/Occupational Safety
Issued 30 April 1998
Resolved
POTABLE WATER PUMP INOP_x001C_ SOLAS 60 REG I/11
Documentation
Issued 6 January 1995
Resolved
Vessels Oil Transfer Procedures list of each product transferred are not listed IAW 33 CFR 154.310(a)(5)(ii).
Documentation
Issued 6 January 1995
Resolved
Vessel's Oil Transfer Procedures does not list procedures/duties for tending the vessels moorings.
Construction/Loadline
Issued 6 January 1995
Resolved
Hull markings, including the Name of the vessel, and the Bulbous bow insignia are not painted in a color contrasting to the hull._x001C_
Navigation
Issued 6 January 1995
Resolved
Vessel greater than 1600 GT, did not have onboard a copy of the Tidal Current Tables 1995 for the Atlantic Coast of North America, required for the transit of the St. Johns River to Jacksonville.
Documentation
Issued 6 January 1995
Resolved
Vessel Cargo Safety [name withheld] states that the vessel has equipment for 30 persons, no more. The vessel arrived with a crew of 29, 02 passengers (wife and son 17 months old) of a crew member, and 02 stowaways, total of 33 people.
Fire Fighting
Issued 6 January 1995
Resolved
Vessel did not have 02 operable Self-Contained Breathing Apparatus (SCBA's)for the fire fighting outfits as required by SOLAS 74 Chapter II Req.17.
Documentation
Issued 6 January 1995
Resolved
Vessel containment did not have mechanical means of closure as required by 33 C.F.R. 155.310(a)(3)
Documentation
Issued 6 January 1995
Resolved
Vessel Oil Transfer Procedures do not contain procedures for operating emergency shutdown, transfer comms, topping off tanks, closing all valves used during transfer operations, reporting fuel cargo spills, and closing/opening vessels openings.
Navigation
Issued 6 January 1995
Resolved
Vessel greater than 1600 GT, did not have onboard the current 1995 Tide Tables High and Low Water Predictions for the East Coast of North and SouthAmerica, or foreign equivalent, required for the transit of the St. Johns River to Jacksonville.
Navigation
Issued 6 January 1995
Resolved
Vessel greater than 1600 GT, did not have onboard a currently corrected U.S. Coast Pilot Vol.4, or foreign equivalent, required for the transit of the St. Johns River to Jacksonville.
Navigation
Issued 6 January 1995
Resolved
Vessel greater than 1600 GT, did not have a onboard a currently corrected U.S. Coast Guard Light List Vol. 3, or foreign equivalent, required for thetransit of the St. Johns River to Jacksonville.
Accommodation/Occupational Safety
Issued 6 January 1995
Resolved
Port railing and a catwalk between the cargo holds was damaged due to heavyweather.
Documentation
Issued 25 July 1990
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Navigation
Issued 25 July 1990
Resolved
A VIOLATION OF 33 CFR 88.05 IN THAT THE VESSEL FAILED TO PRODUCE A COPY OF THE INLAND NAVIGATION RULES. AGENT PROCURED A COPY PRIOR TO DEPARTURE._x001C_ _x001C_ _x001C_
Documentation
Issued 25 July 1990
Resolved
A VIOLATION OF 33 CFR 164.33 (a)(l) IN THAT THE VESSELS CHARTS ARE OUTDATEDAND NOT CORRECTED USING THE NOTICE TO MARINERS, NEW CHARTS WERE PROCURED _x001C_ BY AGENT PRIOR TO DEPARTURE._x001C_ _x001C_
Navigation
Issued 25 July 1990
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Navigation
Issued 25 July 1990
Resolved
A VIOLATION OF 33 CFR 164.30 IN THAT THE VESSEL HAS AN OUTDATED LIGHT LIST.AGENT PROCURED NEW LIGHT LIST PRIOR TO DEPARTURE._x001C_ _x001C_ _x001C_
Navigation
Issued 28 August 1987
Resolved
VESSEL DID NOT HAVE A LARGE SCALE CHART OF SAN JUAN HARBOR A VIOLATION OF 33 CFR 164.33
Documentation
Issued 28 August 1987
Resolved
VESSEL DID NOT HAVE COPIES OF ANY DOCUMENTS OR CERTIFICATES THAT WAS NEED BY THE BOARDING OFFICER A VIOLATION OF 46 CFR 91.60
Navigation
Issued 28 August 1987
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.