Records from 2016 to 2025. Most recent: inspection, 26 December 2025.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 December 2025
Resolved
On a vessel of at least 7.9 meters in length, a visual and audivle alarm must be provided at the operating station to indicate a high water level in each of the following unmanned spaces. (1) A space with a through-hull fitting below the deepest load waterline, such as a lazarete; (2) A machinery space bilge, bilge well, shaft alley bilge or other spaces subject to flooding from sea water piping within the space; and (3) A space with a non-watertigtclosure, such as a space with a non-water-tight hatch on the main deck. MI observed that all high water alarms shared one common visual indicator.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 February 2026
Resolution: Tested newly installed visual/auditory alarms for each separate space. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2025
Resolved
All machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Vessel has through hull fittings and water piping going through the engine battery storage compartment.
46CFR 182.01-5
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 25 February 2025
Resolution: Vessel provided photographic evidence of repairs.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 24 February 2025
Resolved
Machinery and fuel tank spaces shall be separated from accommodation spaces by watertight and/or vapor tight bulkheads of double diagonal wood, marine plywood, steel plate or equivalent construction. Vessel had multiple bulkhead penetrations that were not vapor/water tight.
46 CFR 182.35-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 25 February 2025
Resolution: Vessel provided photograhic evidence of repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 December 2021
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Wet exhaust system has pinhole and is leaking water and exhaust fumes. Repair exhaust system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2022
Resolution: Exhaust system fully replaced, verified while underway. No more leaks.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 2 December 2021
Resolved
The master shall conduct sufficient drills to make sure all crew members are familiar with their duties. CG Inspectors must witness underway drills in accordance with a COI Inspection. Coordinate with Marine Inspector to witness drills.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2022
Resolution: Conducted satisfactory drills.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 2 November 2021
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. Delamination is occurring on forward starboard main deck. Repair deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2021
Resolution: Repaired.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 2 November 2021
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. There are four loose overhead beams (two port, two starboard) in the engine compartment. Provide proof of all beams sufficiently anchored.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2021
Resolution: Repaired.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 2 November 2021
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. Delamination is occurring in the berthing compartment on the port forward bulkhead. Repair delamination.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2021
Resolution: Repaired
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 2 November 2021
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. The starboard rudder post is leaking. Repair leak.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2021
Resolution: Repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 2 November 2021
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs.
Strut backing plate in the fuel tank space is leaking. Repair leak.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2021
Resolution: Repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 2 November 2021
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices must be corrected. Broken glass was found in the child lifejacket storage area. Remove all broken glass.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2021
Resolution: Broken glass cleaned up.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 November 2021
Resolved
Each ring life buoy must marked with Type II retroreflective material approved in 36 CFR 164.018. The arrangement of the retroreflective material must be as specified by IMO Resolution A.658(16). Ring life buoy retroreflective material was not sufficient. Add retroreflective material to ring life buoy.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2021
Resolution: Retro replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 2 November 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 164.041 or a kit with equivalent contents and instructions. Eye wash in first-aid kit is expired. Replace eye wash.
46 CFR 184.710
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2021
Resolution: eye wash replaced.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 2 November 2021
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in applicable unmanned spaces. Visual indicators for all spaces were inoperable and unlabeled. Repair visual alarm and label each alarm.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2021
Resolution: Alarms labeled.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 2 November 2021
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radio-beacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR Part 80. Vessel Radio Station and Radio Telephony Certificates showed different call signs. Obtain a new Radiotelephony Certificate with the correct call sign. Vessel FCC Certificates display a different MMSI number than what is entered into the VHF radio. Obtain a new FCC inspection to issue new Radio Telephony and Radio Station certificates and update emergency calling placards. A Coast Guard Marine Inspector must be present during the inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2021
Resolution: Documents were reissued.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 2 November 2021
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radio-beacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR Part 80. Operator did not have FCC Marine Radio Operator Permit onboard. Permit must be with the operator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2021
Resolution: FCC Marine Radio Operator permit was onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 November 2021
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Retroreflective material and general condition of 04 excess child life jackets were significantly deteriorated. Remove or replace life jackets.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2021
Resolution: Life jackets removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 November 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2021
Resolution: EAP sticker displayed.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 2 November 2021
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radio-beacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR Part 80. Vessel 15-character beacon ID is not identical to the manufacturer installed UIN. Provide proof that NOAA was contacted to resolve the discrepancy.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2021
Resolution: EPIRB replaced and FCC certs matched EPIRB/registration.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 November 2021
Resolved
The fuel shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. Reach rod is held in place with zip ties. Replace with a reliable form of holding the reach rod in place.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2021
Resolution: Zip tie replaced with wire.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 March 2021
Resolved
Vessel has lapsed on its dry dock dates. Vessel shall not operate according to its COI until a satisfactory dry dock exam is conducted.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2021
Resolution: Drydock items all complete, credit given.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 May 2020
Resolved
Found support stringer in fwd anchor line storage to be split, not capable of supporting deck as it was designed, and its where passengers walk. Repair or replace with support board to meet initial strength and support for deck above.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2020
Resolved 1 June 2020
Resolution: Received pictures, all sat
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 May 2020
Resolved
Vessel COI expired on 14MAY2020. Vessel operator notified they cannot operate vessel until a COI examination is completed.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: Underwent a COI examination, All sat
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 22 May 2019
Resolved
Nautical publications: Coast Pilot [name withheld], Tide Tables, and Current Tables for the vessel are not up-to-date. Provide vessel with updated publications.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2019
Resolved 20 June 2019
Resolution: Implemented proper use of electronic publications
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 May 2019
Resolved
Charts not current. Update or replace charts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 31 May 2019
Resolution: Replaced with updated Chart
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 May 2019
Resolved
Life buoy waterlight battery inoperable. Replace battery.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 20 June 2019
Resolution: Battery replaced. Waterlight now illuminates.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 21 May 2019
Resolved
Overboard sewage valve not secured. Secure valve with locking mechanism.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 20 June 2019
Resolution: A lock has been installed on the access hatch to space containing sewage valve.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2019
Resolved
Insufficient retro tape on 01 adult life vest. Replace retro tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 20 June 2019
Resolution: Replaced retro tape
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 February 2019
Resolved
Bilge in berthing compartment needs to be smoothed out so water does not build up under the resin within that space.
Condition: Design Flaw
Due 5 March 2019
Resolved 26 February 2019
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 June 2017
Resolved
Update charts and pubs of area you work. IAW 46 CFR 184.420
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 20 June 2017
Resolution: Current charts and pubs were provided for inspection.
Communications › Alarms/Indicators › High Water Alarm
Issued 7 June 2017
Resolved
Label bilge and high water lights to tell which space. Also FWD compartment and tank room needs bilge pump light to work. IAW 46 CFR 182.530
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 20 June 2017
Resolution: Appropriate labels were added and lights were working.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 7 June 2017
Resolved
SOLAS tape and label PFD’s that were left out during inspection. IAW 46 CFR 180.75
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 20 June 2017
Resolution: Lifejackets were replaced with new and labeled with vessel name.
Documentation › Logs/Records › Logbook (official)
Issued 7 June 2017
Resolved
Catch up EPIRB log. IAW 46 CFR 185.702
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 20 June 2017
Resolution: EPRIB log was current.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 7 June 2017
Resolved
Shore power line has insulation pulled back at boat plug. IAW 46 CFR 176.800
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 20 June 2017
Resolution: Shore power line connected to the vessel was in satisfactory condition.
Engineering › Bilge Water Management System › Hose
Issued 7 June 2017
Resolved
Add hose to hand pump so it can reach all spaces and go out of cabin to go overboard. IAW 46 CFR 182.520
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 20 September 2017
Resolution: Inspected.
Engineering › Bilge Water Management System › Valve
Issued 7 June 2017
Resolved
Thru hull valve needs plug in FWD space starboard side. IAW 46 CFR 179.212
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 20 June 2017
Resolution: Plug was added to the valve.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 7 June 2017
Resolved
Double clamp and single clamps need added in engine room. Check all hoses to verify. IAW 46 CFR 176.800
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 20 June 2017
Resolution: Clamp was added to the hoses.
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 7 June 2017
Resolved
Port engine exhaust cooling needs new hose out board side, and weld area still leaks, make repairs as needed. IAW 46 CFR 182.430
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 20 June 2017
Resolution: Appropriate hoses were installed and leak was fixed.
Communications › Radio Communications › VHF Radiotelephone
Issued 7 June 2017
Resolved
Put proper MMSI number on black face radio. IAW 47 CFR 80
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 20 September 2017
Resolution: Inspected.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 14 July 2016
Resolved
Provide maintenance to all life jackets. Re-label and replace retro tape. Separate all child and adult life jackets label with correct number.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: Life jackets were labeled, maintained, and stowed correctly/separated.
Engineering › Bilge Water Management System › Pump
Issued 14 July 2016
Resolved
Provide high water alarm with audible and visual indicator to fwd compartment. Automatic bilge pump should discharge overboard. A check valve need be installed on discharge line. The ball valve should be located close to through hull fitting.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: High water alarm was provided to fwd compartment. All found sat.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 14 July 2016
Resolved
Pre-engineered system discharge indication panel needs to be at operating station.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: Pre-engineered system indication was placed at operating station.
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 July 2016
Resolved
Make bilge indication light in center compartment operable.
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: Bilge indication light was made operable.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 July 2016
Resolved
Add chaffing gear to sea water suction supply line on port and stbd side.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: Chaffing gear was added to sea water suction supply line on both sides.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 July 2016
Resolved
Replace/ repair lagging on stbd outboard exhaust and re-clamp. Re-clamp port inboard exhaust lagging.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: Lagging was replaced and reclamped.
Engineering › Generator (propulsion-electric) › Cable
Issued 14 July 2016
Resolved
Alternator belt on generator is loose needs to be tightened. Adjust rotating guard that covers alternator.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: Alternator belt was tightened and rotating guard adjusted.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 14 July 2016
Resolved
Water leak on port engine exhaust pipe repair as needed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: Water leak on port engine was repaired.
Electrical › Electric Generation Source (service) › Generator
Issued 14 July 2016
Resolved
Replace generator sea water discharge line at muffler.
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: Generator sea water discharge line at muffler was replaced.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 14 July 2016
Resolved
Add proper cover to receptacle outlet in eng room on fwd bulkhead
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: Receptacle was covered.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 14 July 2016
Resolved
Wiring above generator needs to be cleaned off.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: Wiring above generator was cleaned.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 14 July 2016
Resolved
Collision bulkhead port and stbd side main deck needs to be strengthened deck is weak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: Main deck was strengthened.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 July 2016
Resolved
Check all clamps and add new clamps on drain line for sink and water supply lines for generator.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: New clamps were added and tightened.
Deck/Cargo › Mooring/Anchoring › Anchor Shackle
Issued 14 July 2016
Resolved
Add mousing to anchor shackle.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: Mousing was added to anchor shackle.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 14 July 2016
Resolved
Add sign to aft ladder going topside. Sign should say CREW ONLY.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: CREW ONLY sign was added to aft ladder going topside.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 14 July 2016
Resolved
STBD aft bulkhead top, port side in engine room needs to be sealed. Small 1/2" hole.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: STBD aft bulkhead top, port side in engine room sealed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 July 2016
Resolved
All around anchor light being blocked and is not visible . Move to a different location.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: All around anchor light made visible.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 14 July 2016
Resolved
Post Emergency and radio broadcast instructions at operating station. Add fuel shut off to emergency instructions.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: Emergency instructions and radio broadcast placard placed at operating station.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 14 July 2016
Resolved
Provide update copy of navigation rules.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: Updated copy of navigation rules.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 14 July 2016
Resolved
Provide supervisory training for master.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: Provided supervisory training for master.
Stability › Incline Test › General
Issued 16 March 2016
Resolved
Vessel made structural alterations without the approval of the CG OCMI. Vessel is prohibited from operating with passengers onboard until a new simplified stability test is satisfactorily conducted for the vessel and drawings, sketches, and/or written specifications describing the details (electrical, structural, mechanical, etc.) of the alterations are submitted to the CG OCMI for approval.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2016
Resolved 24 March 2016
Resolution: Performed satisfactory SST