Records from 1983 to 1997. Most recent: inspection, 5 December 1997.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 40
5 December 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 44030
10 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1188624
15 June 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 752673
10 June 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 205109
18 November 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1171369
4 August 1994
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1177101
23 April 1994
Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1168005
8 February 1994
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 852728
20 December 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 662702
18 December 1993
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 849712
17 December 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 139439
18 July 1993
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 845422
25 June 1993
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 844061
21 May 1993
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 829115
26 March 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 831934
25 January 1993
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1133867
9 September 1992
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 936913
7 August 1992
Excursion Permit
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 951599
19 March 1992
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1009057
5 March 1992
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1011181
12 September 1991
Drydock Extension
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1252440
30 April 1991
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1210975
25 February 1991
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 931649
29 June 1990
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 912860
26 April 1990
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 897931
16 April 1990
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1212167
5 April 1990
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 906138
5 March 1990
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1211323
16 January 1990
Excursion Permit
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 927008
6 March 1989
COI Inspection · Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1208083
8 February 1989
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1348046
23 May 1988
Re-Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1044336
10 July 1987
Re-Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1318247
8 June 1987
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1318555
24 May 1986
COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1304047
16 July 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 978201
6 April 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1287222
2 February 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 972420
1 February 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 972418
5 November 1983
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1280113
Engineering
Issued 18 December 1993
Resolved
REPLACE HYDRAULIC HOSE FITTINGS ON STARBOARD SIDE, BETWEEN AFT BULKHEAD ANDPADDLE WHEEL MOTOR.
Condition: Unknown
Due 18 December 1993
Resolved 18 December 1993
Construction/Loadline
Issued 21 May 1993
Resolved
NO HOSES ATTACHED TO HAND BILGE/FIRE PUMP._x001C_
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Lifesaving
Issued 21 May 1993
Resolved
SIGNALING LIGHT ON RING BOUY FUNCTIONING IMPROPERLY.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Lifesaving
Issued 21 May 1993
Resolved
INSUFFICIENT AMOUNT OF ORANGE SMOKE FOR DISTRESS SIGNALING ON BOARD.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Accommodation/Occupational Safety
Issued 21 May 1993
Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF TOILET IN WOMEN'S RESTROOM.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Fire Fighting
Issued 21 May 1993
Resolved
MAIN FIRE PUMP FUNCTIONING IMPROPERLY.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Documentation
Issued 25 February 1991
Resolved
Either obtain a waiver from the Federal Communication Commission for, or, obtain and place on board the vessel an FCC Safety Radiotelephony Certificate and Radiotelephone. Route is restricted to operation not more 1,000 feet from shore until compliance is met.
Condition: Unknown
Due 25 February 1991
Resolved 25 February 1991
Engineering
Issued 16 April 1990
Resolved
CONDUCT TEST OF STARBOARD PADDLE WHEEL HYDRAULIC MOTOR TO THE SATISFACTION OF THE ATTENDING CG INSPECTOR PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990
Construction/Loadline
Issued 5 March 1990
Resolved
IF BALLASTING REQUIRED, PLANS FOR INSTALLATION OF FIXED BALLAST SHALL BE SUBMITTED TO THE COGNIZANT OCMI FOR APPROVAL AND A STABILITY TEST CONDUCTED
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Construction/Loadline
Issued 5 March 1990
Resolved
REMOVE WATER BALLAST FROM FORWARD COMPARTMENT.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Accommodation/Occupational Safety
Issued 6 March 1989
Resolved
REMOVE PAINT/PAINT LOCKER FROM VESSEL. ITEM 1 TO BE COMPLETED PRIOR TO CARRYING PASSENGERS FOR HIRE TO THE SATISFACTION OF THE ATTENDING CG MARINEINSPECTOR BUT NOT LATER THAN 16MAR89.
Condition: Unknown
Due 6 March 1989
Resolved 6 March 1989
Electrical
Issued 8 February 1989
Resolved
PROVIDE COVER FOR ISLE SIDE OF ELECTICAL CONNECTIONS ON ENGINES.
Condition: Unknown
Due 8 February 1989
Resolved 8 February 1989
Construction/Loadline
Issued 8 February 1989
Resolved
MAKE WATERTIGHT STUFFING TUBES IN AFT ENGINE ROOM BULKHEAD AT FORMER PENETRATION POINTS OF HYDRAULIC LINES.
Condition: Unknown
Due 8 February 1989
Resolved 8 February 1989
Electrical
Issued 8 February 1989
Resolved
REMOVE EXTENSION CORD TO SECURITY LIGHTS AND HARD WIRE TO JUNCTION BOX, OR REMOVE ALL LIGHTS.
Condition: Unknown
Due 8 February 1989
Resolved 8 February 1989
Accommodation/Occupational Safety
Issued 8 February 1989
Resolved
RENEW ALL WINDOWS IN HOUSE THAT ARE CRACKED.
Condition: Unknown
Due 8 February 1989
Resolved 8 February 1989
Engineering
Issued 1 February 1984
Resolved
HAVE BELT GUARDS INSTALLED ON ALL ENGINES.
Condition: Unknown
Due 7 February 1984
Resolved 1 February 1984
Engineering
Issued 1 February 1984
Resolved
HAVE EXHAUST SYSTEM INSULATION, LAGGING OF BOTH PROPULSION ENGINE REPAVED WITH PROPER MATERIALS.
Condition: Unknown
Due 7 February 1984
Resolved 1 February 1984